Home / Financial Firm (Unknown - Insurer) / Determination 482169

Determination 482169

Roof and garage damage claim declined under exclusions

FirmFinancial Firm (Unknown - Insurer)
Decided2018-04-26
ProductGeneral Insurance · Business / commercial
OutcomeFor the complainant
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant's claim for roof and garage damage was declined under wear, tear and workmanship exclusions. AFCA found the FSP had not established the exclusions and ordered it to indemnify the claim with interest.

The insurer bears the onus of proving policy exclusions on the balance of probabilities, and its engineer's evidence did not establish them.

Issues

Subjects and remedies

home or building damagenatural disasterpay claimpay interest

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 482169 Determination Page 1 of 7 Case number: 482169 24 April 2018 1 Overview 1.1 Dispute The financial services provider (FSP) denied the applicant‟s claim for replacing his roofs on the property and garage on the basis it falls within a number of policy exclusions. This includes exclusions for wear and tear or faulty workmanship. The applicant disputes this as he says the damage was due to the Black Saturday fires. 1.2 Issues and key findings Can the FSP deny the claim? The FSP cannot deny the claim because the evidence does not show the roof damage was caused by wear and tear or faulty workmanship. 1.3 Determination This determination is in favour of the applicant. The FSP is required to indemnify the applicant for this claim and pay interest on any amount paid to the applicant. Case No: 482169 Determination Page 2 of 7 2 Reasons for determination 2.1 Can the FSP deny the claim? FSP is relying upon a number of policy exclusions These relevant facts are not in dispute:  the property was built around 1976 and the garage around 2001  the property was in good condition prior to the fire  the applicant cleaned the roof in 2008 in preparation of his daughter‟s wedding  the property was affected by the Black Saturday fire in 2009 The FSP relies on the following policy exclusions to deny liability for the applicant‟s claim: “… we will not pay for loss of or damage to your Farm Property caused by: … 4. faulty materials, faulty workmanship, wrong or incorrect design, plan or specification or failure of design; 5. wear, tear, rust, corrosion, depreciation, gradual deterioration, mildew, mould, dampness of atmosphere or variations in temperature .” The FSP has the onus of proof in establishing the exclusions. The standard of proof is the balance of probabilities. FSP’s position is not substant iated In support of its position, the FSP is relying upon engineer DC. The applicant has provided two opinions from roofers AB and BM in support of his position. Their evidence is set out in sections 3.1 and 3.2. Having carefully reviewed the available ev idence, I am not satisfied DC‟s evidence is sufficient to establish the exclusions the FSP is relying upon for the following reasons. First, if the roofs and screws were affected by wear, tear or gradual deterioration, it does not explain why similar deterioration was evident to the garage which is much younger. Second, DC has not addressed the possibility of retardant and chemicals affecting the roof. AB and BM accepted the damage can, or is, associated with this. The FSP notes the applicant‟s reference t o retardants and chemicals are new matters. However, I note these factors surround the context of the extensive fire and events in 2009. Therefore, I accept they are associated with the claimed event. Third, DC‟s recent position that the roof could have b een affected by soot and smoke by the applicant‟s fireplace is inconsistent with its pre -existing condition. Both the applicant and the FSP‟s agent accepted the roof was in excellent condition prior to the fire. Further, the FSP‟s agent confirmed the prope rty was covered in ash and very dirty shortly after the fire. Case No: 482169 Determination Page 3 of 7 In addition, if the fireplace had the ability to affect the roof in this manner, it is reasonable to presume its effects would have been evident shortly after its construction. There is nothing to indicate that is the case. Fourth, the reference to faulty workmanship is not established for the property given it was constructed prior to the Australia standards referred to by DC. Regarding the garage, I accept the screws appear to be faulty based on the applicable standards. However, I am not satisfied the evidence shows this workmanship was the cause of the damage. Predominantly because:  DC did not take into consideration the effect of retardant or chemicals  the roof exhibits similar issues as the property  it is unclear why the screws rusted at a similar rate to the property when they were installed 25 years later FSP required to indemnify the applicant The FSP is liable to indemnify the applicant for the roof damage to his property and garage. In the event any aspect is cash settled, the FSP is to pay interest on that amount pursuant to section 57 of the Insurance Contracts Act 1984 (the Act). Interest is payable from 29 August 2011, being the date it denied liability, until the date of payment. Case No: 482169 Determination Page 4 of 7 3 Supporting information 3.1 Engineers comments Engineers report dated 16 August 2011 SITUATION OF DAMAGE: … The roof over the lnsured's residence, including the attached small building, covers an area of approximately 550m2. … The roof and walls of the garage/workshop is clad with metal sheets. The L -shaped garage/workshop has a plan area of approximately 450m2. The age of the residence is approximately 35 years old and the L-shaped garage/workshop is approximately 10 years old. The Insured advised us that they have occupied the residence for approximately 18 years. BACKGROUND INFORMATION: We were advised by the Insured that a layer of soot and ash blanketed the residence and his vehicles during the bushfire event in 2009. He advised that the strong winds had blown the soot and ash onto his property. The Insured also advised us that rainwater from the roof is collected and stored in a water storage tank. As they were consuming water from the water storage tank, he had to disconnect all the downpipes and flush away the soot and ash from the roof to prevent it from entering the water tank. The Insured informed us that he had removed and replaced with new, the eaves gutters and downpipes surrounding the residence at his own expense. The Insured also informed us that the Plumber from [MP] only included the removal and replacement of metal roofing sheets over the residence but did not include the metal roofing sheets over the garage/workshop. We have received from the Loss Adjuster, a copy of the quotation for the sum of $17,800 (excluding GST) from [MP]. The work covered in this quotation includes the removal and replacement of the metal roofing sheets with new. OBSERVATIONS: We carried a detailed inspection of the roof above the lnsured's residence and the garage/workshop and observed the following: Residence  We were advised by the Insured that there were no known leaks within the residence from the roof.  The metal roofing sheets over the lnsured's residence have evidence of oxidis ation. The metal roofing sheets have lost the shine and had a dull appearance. The Insured also advised us that the roof sheets had lost their colour.  Most of the tek screws used to secure the metal roofing sheets to the lnsured's residence have evidence of rust.  Some of the rust from the tek screws had transferred on to the metal roofing sheets in some areas.  The flashing along the bottom edge of the skylight located at the south -west corner of the lnsured's residence has evidence of rust.  There was evidence of soot at the east side of the lnsured's residence in the vicinity of the flue for the fire place in the lnsured's residence. Case No: 482169 Determination Page 5 of 7  There was evidence of soot along the hip of the roof located at the south-east corner of the lnsured's residence.  Using our finger, we were able to rub some of the soot away from the surface of the roof sheets. Garage/Workshop  As the roof covering of the garage/workshop was newer than the roof sheets covering the lnsured's residence, it still has a glossy and shiny appearance.  There was evidence of rust to the tek screws used to secure the roof sheets to the garage/workshop.  We observed that a few of the tek screws had exposed shanks that were not rusted. The rust was localised only to the head of the tek screws.  There was evidence of soot along the apex of the roof.  There was evidence of soot at the top of the centrifugal rotating extractor fan above the garage/workshop. CONCLUSIONS: There were several locations surrounding the lnsured's property that were affected by the Bushfire. Some of these areas included Drouin, Longwarry, Churchill, Callignee and Jeeralang etc. The closest town that was affected by the Bushfire was located approximately 20km away from the lnsured's property. It is therefore possible that soot and ash from the bushfire had been blown onto the lnsured's property by strong winds. We note that the lnsured's residence is within 12km of … P ower Station. This is closer than the areas of the bushfires. The prolonged discharge from the power station is more likel y to have affected the roof than the once off effect of the bushfires. Fasteners used to fix roofing products must give long, trouble free service when exposed to the atmosphere in environments ranging from benign to severe in terms of corrosive effect. All fasteners for the roof sheets must have a coating system to meet AS 3566 -Self Drilling Screws for the Building: Class 3 or Class 4 -Corrosion resistance requirements. AS 3566 specifies the requirements for four levels of the corrosion resistance of self-drilling screws for the building and construction industries. Therefore, the minimum requirement for fasteners used to secure roofing sheets is Class 3. Class 1 and 2 fasteners are not suitable to be used for roofing sheets. It is our opinion that the fasteners, or tek screws, used to secure the lnsured's roof sheets did not comply with AS 3566 -Class 3 or Class 4. The tek screws that were used were therefore not appropriate for use on the lnsured's metal roofing sheets. It is our opinion that the tek screws would have corroded under normal circumstances and not specifically due to the soot and ashes from the bushfire. Following our inspection to the lnsured's residence, it is our opinion that the cause of damage to the lnsured's roofing sheets was due oxidization over an extended period of time. The metal roofing sheets covering the lnsured's residence consist of galvanised steel. Galvanised steel roofing sheets are prone to rust after its zinc coating wears away from the surface. The typical life span of galvanised steel roofing sheets is 20-30 years before re- coating of the sheets are required. The lnsured's roof sheets covering the residence are approximately 35 years old, had a dull appearance and had evidence of oxidisation throughout the roof. We n oted that the newer roof sheets covering the lnsured's garage/workshop still had a glossy and shiny appearance. It is therefore our opinion that the roof sheets covering the residence were nearing the end of their lifespan and a re-coating or replacement of the roof sheets is now required to rejuvenate the life of the roof. Although the Insured had washed and flushed the soot and ashes off the roof after the bushfire event, we noted there were still some evidence of soot at the south and south -east sides of the lnsured's residence. There was also evidence of soot along the apex of the roof and on top of the centrifugal rotating extractor fan above the garage/workshop. Given the above, we are of the opinion that the soot from the bushfire in 2009 had not caused the damage to the lnsured's metal roof sheets and the tek screws used to secure the roof sheets. It is our opinion that the soot had merely stained some parts of the lnsured's roof sheets but the soot did not cause the roof or the tek screws to corrod e and Case No: 482169 Determination Page 6 of 7 rust. It is our opinion that the lnsured's roof would have deteriorated to the same extent, even if it had not been covered in soot from the bushfires. RECOMMENDATIONS: If liability is accepted in this instance and reinstatement works are to be und ertaken we expect the reinstatement works to mainly consist of:  Remove and replace with new, the soot stained roof sheets to the lnsured's residence and garage/workshop,  Remove and replace with new, the corroded tek screws to reattach the new roof sheets to the lnsured's residence and garage/workshop. The new tek screws are to comply with AS 3566 - Self Drilling Screws for the Building: Class 3 or Class 4.  Remove and replace with new, all flashings as required. Email from Engineer dated 15 November 2011 “No other roofs in the area have been damaged by proximity of … Power Station.” BlueScope Steel produce specialist grade of metal roofing sheets that are “ suited to more demanding environments, like those by the sea or in areas prone to industrial or chemica l fumes and fallout ”. The other roofing sheets in the insured‟s neighbourhood could be of a different grade to the insured‟s. „Roof is Colour Bond, not Galvanised Steel as noted in the report.” ColorBond is a brand. They make both galvanised steel roofing sheets and zincalume steel steel roofing sheets. The main difference between the two types of roofing sheets are the coating. Galvanised steel roofing sheets are mainly coated with zinc and zincalume steel roofing sheets are coated with a zinc/aluminium alloy. Both are susceptible to oxidation and corrosion. “The screws have rusted significantly in the last 2 years.” As mentioned in our report, all fasteners for the roofs sheets must have a coating system to meet AS 3566 – Self Drilling Screw for the Building: Class 3 or Class 4 – corrosion resistance requirements. It is our opinion that the fasteners used on the Insured‟s roof did not meet this requirement and has subsequently corroded. Email from engineer Date 16 November 2017 From: DC Sent: Thursday, 16 November 2017 9:30 AM To: SP Subject: Re: FW: URGENT: FOS Case 482169, [applicant] and [FSP] Hi SP, … I bring your attention back to my previous email and within my report that the Insured's fireplace would also have produced soot and smoke. Smoke and soot from the Insured's fireplace would be the primary cause of staining to the roof sheets. Soot and smoke from the bushfire would have contributed to the existing staining of the roof sheets. Case No: 482169 Determination Page 7 of 7 3.2 Applicant’s Reports Record Key points AB Rep ort Undated “We completed an inspection last week (26/07/2017), we‟ve come to the conclusion that the roof and screws have deteriorated and need to be replaced due to the ash and soot. The retardant & chemicals used fighting the fires is also still present on the roof.” B M Report 11 August 2017 “The fires of 2009 would have definitely contributed to the accelerat ed deterioration of this roof being the rusting of the tek screws and the staining of the sheets. The ferocity of the fires of 2009 left soot and ash as well as the chemical retardants which have attributed to severity of the staining and rust. The residue is like coating that causes these problems. I note the roofing on the shed was only approx. 10 years old and it has the same discolouration, stai ning and rusting of the main house.”

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.