Home / Financial Firm (Unknown - Insurer) / Determination 482166
Determination 482166
Water damage to en suite denied under shower base and recess exclusion
Summary
The applicants claimed under their home policy for water damage to their en suite after leaking pipework was suspected. The FSP denied the claim as caused by water escaping from the shower base, which is excluded, and AFCA agreed and ordered nothing.
The weight of the plumbing and moisture evidence showed the damage was caused by gradual escape of water from the shower base, which the policy expressly excludes.
Subjects and remedies
no remedy
Text of the determination
Determination
Case No: 482166 Determination Page 1 of 5
Case number: 482166 23 March 2018
1 Overview
1.1 Dispute
The applicants lodged a claim under their home insurance policy with the financial
services provider (FSP) for water damage to their en suite bathroom (and
surrounding areas) in October 2016.
After appointing its contractors to assess the damage, the FSP denied liability for the
claim on the basis that the damage was caused by water leaking from a shower base
or shower walls. The policy excludes cover for damage caused in this manner.
The applicants disputed the FSP’s decision. Based on the findings of their
contractors, the applicants say the damage was caused by a leak from the
combination pipework in the wall ca vity behind the shower. Accordingly, they
consider the FSP is liable for the costs of repairing the damage.
1.2 Issues and key findings
Is the FSP liable for the water damage to the applicants’ property ?
The available information establishes that the damage was caused by the gradual
escape of water from a shower base or recess. The policy excludes cover for
damage caused in this manner. Accordingly, the FSP is not liable for the damage.
1.3 Determination
This determination is in favour of the FSP.
The FSP is entitl ed to deny the applicants’ claim .
Case No: 482166 Determination Page 2 of 5
2 Reasons for determination
2.1 Is the FSP liable for the water damage to the applicants’ property ?
Policy provides cover for escape of water subject to exclusions
The applicants’ policy provides cover for damage caused by the insured events listed
in the policy, subject to the conditions and exclusions set out in the policy.
The insured event of ‘water or other liquid damage’ covers damage which results
directly from the leaking of fixed apparatus or fixed pipes.
However, there is a specific exclusion for damage caused as a result of the gradual
escape of liquid over time from a shower base, shower recess, shower alcove or the
walls surrounding the shower.
The applicants say the damage to the bathroom flooring and surrounding areas was
caused by water leaking from broken combination pipework in the wall cavity.
However, the FSP says the damage was caused by water leaking through a gap
between the base of the shower and the wall panel.
Accordingly, the FSP ’s liability for the claim depends on the source of the leaking
water.
FSP relies on findings of its contractors in October 2016
After the applicants lodged their claim, the FSP appointed a loss adjuster (CL) to
inspect the damage.
The loss adjuster (CL) advised that the damage appeared to have been ongoing for
some time but would not have been apparent to the applicants due to its location. CL
appointed a plumber (AL) to determine the cause of the damage.
The FSP’s plumber (AL) attended the property on 31 Octo ber 2016. He reported that:
a section of the plaster wall in the master bedroom walk-in wardrobe had been
removed prior to his inspection and the timber wall frame in this area was
rotten. However, moisture tests revealed low levels of moisture in the wall
the cold water pipe to the shower had been re-plumbed before the applicants
purchased the property (indicating that a prior leak may have contributed to the
damage in this area)
pressure tests of the hot and cold water pipes to the shower and the
combination pipework did not identify any current leaks
a spray test to the shower wall tiles identified that water was leaking between
the wall panel and the base of the shower, contributing to the damage
observed.
While there was evidence of past repairs to the cold water pipe, given the mouldy
odour in the applicants’ daughter’s bedroom, CL was satisfied that there was also a
current leak (being the leak through the shower base identified by AL).
Case No: 482166 Determination Page 3 of 5
Based on the CL and AL’s findings, the FSP says it is not liab le for the water damage
to the property because the policy excludes cover for the gradual escape of water
from a shower recess, walls or base.
Applicants ’ contractors advised damage was caused by leaking pipework
The applicants dispute the findings of the FSP’ s contractors. They have provided a
report from their plumber (LT) who attended the property in March 2017.
LT reported that:
a hydraulic test of the shower combination revealed a slight loss of pressure
a pneumatic pressure test of the shower combination revealed a loss of
pressure of approximately 50kPa per minute
a flood test of the shower base identified that small amounts of water were
being released from the base.
Based on his test results, LT concluded that the water damage to the areas around
the shower had been caused by the leak in the combination pipework, together with
the small amount of water escaping through the shower base.
The applicants have provided letters from several plumbing and building consultants
which refer to LT’s report and s tate that the leaking combination pipework caused the
damage to the areas surrounding the shower.
The applicants have also provided a report from the builder (SC) who they appointed
to repair the damage in late 2017. SC provided a number of photographs taken
during the repair process.
In his report, SC stated that, based on his observations, the damage to the flooring
was caused by water leaking from the broken shower combination. SC reported that:
the damage to the flooring was concentrated at the base of the pipe
water had travelled down the pipes from the combination join before pooling at
the base of the pipe and causing the flooring to rot
any leaks from the shower base had occurred due to water from the leaking
combination damaging the bottom plate, causing it to move.
Damage was caused by water escaping from shower base
Having carefully reviewed the reports provided by the various contractors, I consider
that the damage which is the subject of the applicants’ claim was caused by water
leaking through the shower base (and not by a leak from the combination pipework).
The FSP’s plumber (AL) tested the shower combination under hydraulic pressure in
October 2016 and did not identify any leaks. Moisture tests conducted by AL
revealed low levels of moisture in the wall and he did not observe any water in the
wall cavity.
T he applicants’ plumber (LT) identified a leak from the combination pipework, using
both hydraulic and pneumatic pressure. Howev er, LT’s tests were not conducted until
approximately four months later and therefore are not necessarily reflective of the
condition of the pipes at the time the damage occurred.
Case No: 482166 Determination Page 4 of 5
I acknowledge that the applicants consider that the methods used by AL were
outdated and inaccurate. However, I am not satisfied that the information provided
justifies discounting AL’s test results.
Both AL and LT identified a leak of water from the shower base. The gap between
the shower base and the wall panel is clearly visible in the photographs.
Further, I consider that the nature and extent of the damage is more consistent with it
having been caused by the leaking shower base than leaking combination pipework.
In considering the nature of the damage, I have carefully reviewed the photographs
taken by SC during the course of the repairs, as well as the photographs taken by the
FSP’s contractors in October 2016.
The reports and photographs provided confirm that there was extensive rot to the
timber bottom plate and particle board flooring in the shower area.
However, there was no sign of long term damage to the stud wall to which the
combination pipework was attached (although there was damage in the area near the
previously re-plumbed cold water pipe).
FSP is not liable for claim
For the reasons outlined above, I am satisfied that the FSP is entitled to deny the
claim on the basis that the damage was caused by the gradual escape of water from
a shower base or shower recess.
To the extent that there is pre-existing damage caused by a prior leak from the cold
water pipe, the FSP is not liable for this damage as it occurred prior to the
commencement of cover.
Case No: 482166 Determination Page 5 of 5
3 Supporting information
3.1 FOS approach to this dispute
This dispute was the subject of a recommendation issued on behalf of the Financial
Ombudsman Service (FOS) on 30 October 2017. The recommendation was rejected
by the applicants.
This dispute has been determined based on what is fair in all the circumstances,
having regard to the relevant law, good industry practice, codes of practice and
previous FOS decisions (which are not binding).
There has been a full exchange of all material information relied on for the purposes
of this determination and each party has had the opportunity to address any issues
raised by the other. All of the material provided by the parties has been reviewed and
considered (whether or not it is expressly referenced in this determination).