Storm water damage claim declined for defective building work and poor maintenance; carpet removal

FirmFinancial Firm (Unknown - Insurer)
Decided2018-03-13
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss$100
Amount claimed—
SourceAFCA PDF

Summary

The applicants claimed storm damage to their home and contents, which the FSP declined as caused by defective building work and poor maintenance. AFCA upheld the decline but ordered $100 compensation for the FSP's handling of the carpet removal.

The proximate cause of the water damage was defective workmanship, structure and maintenance, which are excluded causes under the policy.

Issues

Subjects and remedies

home or building damagepay non financial loss

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 477158 Determination Page 1 of 8 Case number: 477158 5 February 2018 1 Overview 1.1 Dispute The applicants lodged a claim under their home and contents insurance policy held with the financial services provider (FSP) for damage to their property. They say they noticed water leaks in the property after a storm in September 2016. The FSP declined the claim because it says the damage was not caused by the storm, but instead by poor maintenance and defective building work, which are excluded causes of damage under the policy. The applicants dispute the FSP’s decision and say they have never had any leaks or issues with the property until this storm event. They also say the FSP cut away some sections of the carpet when reviewing the damage, and so should be responsible for replacing the carpet. The case manager issued a recommendation on the matters in dispute. The recommendation was in favour of the FSP. The applicant did not accept the recommendation and the dispute has been referred to me for determination. 1.2 Issues and key findings Is the FSP entitled to decline the claim? The FSP is entitled to decline the claim. This is because the proximate cause of the damage was defective building work and poor maintenance, rather than the action of the storm itself. The cause of the damage is excluded from cover. Is the FSP required to rectify the applicant’s carpet ? The FSP is not required to rectify damage it caused to the applicant’s carpet , as this was reasonably required in the circumstances. Although the specific authorisation for that work was not clear or complete, the damage to the underlay and flooring beneath the carpet (as well as the carpet itself) meant it is more likely than not that repairs/replacement would need to have been carried out in any case. 1.3 Determination This determination is substantially in favour of the FSP. The FSP is entitled to decline the claim. However it is required to pay the applicants $100 compensation for its handling of the issue with the carpet. Case No: 477158 Determination Page 2 of 8 2 Reasons for determination 2.1 Is the FSP entitled to decline the claim? The policy provides for insured events subject to exclusions The applicants are required to show, on the balance of probabilities, they have suffered a loss caused by a risk insured against under the policy. This is known as a valid (or prima facie ) claim. If the applicant is able to establish a prima facie claim, then the onus shifts to the FSP to show, on the balance of probabilities, it is entitled to rely on an exclusion under the policy or is otherwise entitled to deny the claim. The applicant’s policy provides cover for damage caused by any of the insu red events listed in the policy (including the insured event of ‘ storm ’ ), subject to certain conditions and exclusions. Amongst other things, the policy states the FSP will not pay for any loss or damage which is caused by or arises from:  gradual deterioration from rain  defects in design, structure, materials, workmanship or construction  wear and tear, gradual deterioration or fading. Applicants have established a prima facie claim The applicants say they noticed their ceiling leaking and floors wet following a storm event throughout the night of 12 September 2016 and the following day. The reports prepared by the various contractors who inspected the applicants ’ property confirm there was water damage to certain sections of the ceilings, walls and floors. I am satisfied, on the available evidence, that the applicants have established a prima facie claim for storm damage to their home and contents. The information shows the property had defects and poorly maintained roof The FSP does not dispute the property was affected by water entry. However, the FSP says it is not liable for the applicant’s claim because the damage was caused by defective workmanship, defective structure and a poorly maintained roof. The FSP’s assessor (C) organised for a roofing consultant (B) and a restoration service (SR) to attend the property, assess the cause of the damage and ensure the property was safe. The roofing consultant concluded that the water ingress points and damage appeared to be construction and maintenance issues rather than caused by a recent storm event. The roofing consultant reported the following:  previous waterproofing attempts visibly noticeable  box gutter found to be undersized and constructed too shallow Case No: 477158 Determination Page 3 of 8  box gutter appears to have more recent works carr ied out…works have been completed poorly  screw fixings low in box gutter are incorrect type and potential water leak point  roof above kitchen has also allowed water ingress due to undersized box gutter  back balcony roof has sheeting laid incorrectly, some roof sheets are not to Australian Standards  roof pitch is under five degrees and corrugated iron has been used which does not meet Australian standards. The restoration service stated the colouring from the water leak indicated the leak was much older than the storm event and had been leaking for longer than a month. The applicants expressed their dissatisfaction with those reports, so the FSP agreed to appoint another service to provide a further opinion on the cause of the water ingress. The additional service appointed was a building consultant (S) who advised the following:  the extent of the damage to the ceilings, floors and walls indicates that water has entered at the locations on multiple occasions  the box gutter has been painted in isolated sections which indicate an attempt to repair or prolong the life of the gutter  the box gutter measured approximately 40 mm in depth, which is not sufficient depth for a box gutter, the minimum recommendation depth is 70mm in accordance with the relevant Australian Standards  the guttering system was not designed with any provision for overflow as per the recommendations contained in the relevant Australian Standards  the water ingress is the result of defective building work, it is not the result of the storm. It is evident, from the available evidence, that there are a number of building, repair and workmanship defects present in the property, and especially with the guttering. The indication by the applicants that they had not previously experienced any problems does not, in itself, mean the defects did not already exist or were not the underlying reason for the damage. The FSP has established an exclusion applies and can decline the claim It is well-established law that a ‘ proximate ’ cause is the effective, dominant or operative cause. The courts have said that if one cause would not have resulted in the harm/damage in the absence of the other cause, then the other cause is the proximate cause of the damage. I am satisfied the evidence is clear that there are structural defects and faulty workmanship on the roof in the location of the damage. While the rain may have caused the water entry, I do not accept the storm alone would have caused the damage if it was not for those pre-existing issues. As well, the expert reports identify previous waterproofing attempts , which reasonably indicates wear and tear and gradual deterioration. I am satisfied, on the available evidence, the proximate cause of the damage was defective workmanship, Case No: 477158 Determination Page 4 of 8 defective structure and a poorly maintained roof. That means the damage is excluded from cover and the FSP is entitled to decline the applicants’ claim. 2.2 Is the FSP required to rectify the applicant’s carpet ? Not unreasonable for sections of carpet to be cut out It is not in dispute the FSP removed sections of the applicants’ carpet in the course of the investigation and dealing with the claim. The FSP says the restoration service advised parts of the carpet were decaying and contaminated with black water and therefore urgent removal was required. The applicants say there was no need to remove the sections of the carpet, because there was no visible damage and it could not have been ‘black water’ contamination given the source of the water leak was not from sewerage or waste. The applicants say they were effectively forced to allow the sections to be cut out for the claim to be assessed. ‘ Black water ’ is any waste from toilets or urinals. It is different from ‘ grey water ’ which is water from sinks, showers, washing machines and dishwashers. I agree that there is nothing to show it could have been black water contamination in the carpets, given there is no evidence to suggest the water ingress was from sewerage or urinals; nor was it from sources of grey water. So I am not satisfied, on the available evidence, that the carpet was contaminated from an inherently unhealthy and dangerous source (black water) and needed urgent removal for that reason. However, regardless of the type of water involved, the information provided refers to the already ‘rotten smooth edge’ of carpet, and presents clear evidence of on-going water ingress and ‘decay of affected wet areas’, including the sub -floor beneath the removed carpet. Black mould growth was also found on the flooring in 3 of the water - affected rooms, and it is reasonable to assume that growth is most likely to have worsened and expanded if the extent of the water damage to the carpet and beneath it had not been identified by having the sections removed in the first place. The state of the flooring under the removed carpet, including what was identified as some long-term damage, also reasonably suggests that other action (such as attempts to dry the areas without actual removal of the carpet) would not have allowed for all damage and any possible associated health risks to be properly identified and rectified. So although the applicants say there was no visible damage and there was no black water contamination justifying the removal of carpet, I do not consider the applicants have suffered a loss for which the FSP is reasonably responsible. That is because it is more likely than not that thorough and effective repairs to the property, and mitigation of health risks, would have involved removal of the carpet in any case. The signed authorisation was incomplete The applicants say they were told the carpet had to be removed to progress their claim and that is why the authorisation was signed for the FSP’s contractor s to proceed. Case No: 477158 Determination Page 5 of 8 The document has a tick next to the statement: I / we, (as insured / owners) authorise the attending representatives of [restoration service] to remove and dispose from the above mentioned property, the floor covering(s) deemed by them to be non-salvageable. However the document also has the below check box which has not been ticked by the applicants: I / we also accept full responsibility for any costs associated with the replacement of the removed floor covering(s), in the event the insurance claim is not covered under the policy. That means it is not clear that the applicants agreed to waive any right they might have to require the FSP to take responsibility for costs associated with the replacement of the removed carpet. I accept, on balance, that it was not unreasonable for the carpet to have been removed in order to properly investigate the claim and deal with any damage. However, I am not satisfied that the applicants were made fully or appropriately aware of the reasons and the implications of that. I consider the FSP’s actions caused the applicants unnecessary concern and loss of expectation, and that it is fair in the particular circumstances that compensation of $100 be paid. Case No: 477158 Determination Page 6 of 8 3 Supporting information 3.1 Relevant policy wording Pages Key points 20 Storm Covered Loss or damage caused by storm, including cyclone, hail, wind, snow or rain. Not covered Loss or damage caused by or resulting from: gradual deterioration from rain 12 General Exclusions Of course, insurance can’t cover absolutely everything. Here are the general exclusions that apply to all cover described in this PDS. Your policy does not cover any loss or damage that is caused by or arises from: … Maintenance and building defects in design, structure, materials, workmans hip or construction Wear and tear, and environmental conditions •wear and tear, gradual deterioration, or fading 3.2 Expert Reports Record Key points FSP’s Claim’s Assessor Report (C) 30 - 09 - 2016  Poorly maint ained roof has allowed wat er damage to areas throughout home.  Bedroom 2: Inspection of the roof above this area has confirmed the resultant damage is consistent with overflow of the undersized box gutter installed above. Inspection of this damage does not appear consistent with a single defined storm event.  Front Entry/Upstairs Landing: Resultant damage has been caused by poor condition of fr ont canopy roof tray which was found to be loose and lifting in the wind. Whilst onsite our roof specialist silicone the area and weighted down with bricks to temporarily secure the area. Inspection of the Front Entry damage found previous repair attempts revealing the area has suffered water damage previously.  Open Plan living area/Kitchen area: Inspection of the roof above the kitchen area revealed water ingress is consistent with overflow of the undersized box gutter.  Ensuite: Investigation of the roof a bove the ens uite revealed the box gutter to be undersized and constructed too shallow and not wide enough to cope with roof water volumes. We found the sisalation paper was damaged and cracked under the roof tiles which reveals previous issues with the are a holding water. We found evidence of Case No: 477158 Determination Page 7 of 8 poor repairs carried out to this area, screw fixings have been installed low in the box gutter which are points of water ingress. Poorly installed flashing over the existing box gutter has not been installed to Austral ian standards.  Back Balcony Roof: We inspected the renovations currently being undertaken to the back balcony roof.  We found the following issues with this area. - Screw fixings have been incorrectly installed low in the quad gutter which are points of wat er ingress. - Roof sheeting has been laid incorrectly with sheet lap the wrong way. - Some roof sheets are too long into guttering whic h is not built to Australian standards. - We found the roof pitch under 5 degrees which does not comply with Australian s tandards. - Garage box gutter is rusted and pitted and require replacement.  Other roof issues: - We found general roof issues that included loose nail fixings in parapet cement sheet wall cladding. - Cracking in cement sheet joints. - Cement sheet cladding is loose and requires re - fixing to prevent future water ingress. - Deteriorated TV aerial attachment.  We engaged (S R ) to attend to the water affected carpet. Upon their inspection they found based on the colouring of the water damage that the water leaks have been ongoing contrary to the Insured’s claim. They have removed non - salvageable areas of carpet as these are black water contaminated and require replacement, a signed waiver was obtained from the Insured prior to removal of the carpet.  They found the subfloor in areas the carpet was removed very dark and has started to decay, and therefore not the result of a single defined storm event. Our restoration team applied antimicrobial to mitigate further loss. FSP’s Roof Specialist (B) Roof Report 28 - 09 - 2016  Inspection to wat er ingress points and damages appear to be construction and maintenance issues rather than a rec ent storm event.  No recent storm damages to roof detected. FSP’s Restoration Report (SR) 17 - 09 - 2016  The technician attended site d uring aft er - hours to inspect the affected areas after it was advised gutter flow caused ingress into the property.  The insured stated that he had only noticed the leak a week prior to the technician’s attendance. The technician not ed, based on the colourin g from the leak to the ceiling and water marking that it was obvious that it is a much older leak and seemed as though it has been leaking for longer than a month.  Due to the source of water originating from outside (guttering overflowed and entered throug h the ceiling cavity) the technician has deemed the carpeted areas to be non - salvageable due to black water contamination and also decaying of affected wet areas.  It was also noted that the yellow tongue subfloor has started to decay and is very dark in co lour. The skirting boards in the affected areas Case No: 477158 Determination Page 8 of 8 were swollen and the paint has flaked off.  The technician cut and removed small sections of the wet carpet in the affected areas, and removed the rotten smoot h edge and underlay for disposal.  The debris was v acuumed and anti - mic robial was applied to the affected areas for the prevention of further damages. FSP’s Building Consultant (S) Licenced Builder Report 14 - 02 - 2017  I am of the opinion that rainwater has overflowed the vertical upstand of the box gutter at the perimeter of the building because the depth of the box gutter has not been designed in accordance with the recommendations contained in Australian Standard 2180 – 1986 Metal Rainwater Goods – Selection and Installation.  I am of the opinion that rain water has overflowed the vertical upstand of the box gutter at the perimeter of the building because the guttering system was not designed with any provision for overflow, as per the recommendations contained in Australian Standard 2180 – 1986 Metal Rainwa ter Goods – Selection and Installation.  I am of the opinion that the brick veneer walls and flas hings surrounding the openings in the external walls have not protected the internal floor and floor frame from the weather in accordance with the requirements of Australian Standard 1684 – 1979 SAA Timber Framing Code.  I consider this to be the res ult of defective building work. It is not the result of storm activity.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.