Home / Financial Firm (Unknown - Insurer) / Determination 475578

Determination 475578

Denial of cracking damage claim under tree root and off-site leak exclusions

FirmFinancial Firm (Unknown - Insurer)
Decided2018-05-09
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant's home developed foundation cracking and the FSP denied the claim under tree root and off-site stormwater exclusions. AFCA found the leaks were on site and tree roots were not shown to cause the blockage, and ordered the claim accepted and repaired, with interest if cash settled.

Once the insured shows a covered loss, the insurer must prove the proximate cause falls within an exclusion, which it failed to do.

Issues

Subjects and remedies

home or building damagepay claimpay interestrepair or rectify

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 475578 Determination Page 1 of 6 Case number: 475578 8 May 2018 1 Overview 1.1 Dispute The applicant lodged a claim with the financial services provider (FSP) after her home started to experience cracking damage. The FSP investigated the cause for the cracking. It found a blockage in the stormwater pipe near the footpath of the home was causing pressure to build up in the storm water line, which in turn caused water to leak into the footings. Its engineer considered the cause of the blockage to be tree root intrusion or debris collection. The FSP subsequently denied the claim on the basis the proximate cause of the damage was the actions of tree roots, which was expressly excluded from cover. It also noted water leaking from pipes not on the property was also excluded from cover. The applicant disagrees with the FSP‟s decision noting she has insured the property with it since 1971 and has only lodged two small claims for water damage to the kitchen before now. 1.2 Issues and key findings Is the FSP entitled to deny the applicant’s claim? The FSP is not entitled to deny the applicant‟s claim because:  the proximate cause of the damage was water leaking or escaping from pipes into the soils surrounding the foundations leading to movement  it has not established the application of the exclusions it is relying upon. 1.3 Determination This determination is in favour of the Applicant. The FSP is required to accept the applicant‟s claim and undertake the required repairs to reinstate the property (unless the applicant would prefer a cash settlement based on current repair costs). If the applicant elects to cash settle, interest is to be paid from 27 April 2017 until the date payment is made in accordance with section 57 of the Insurance Contracts Act 1984 . Case No: 475578 Determination Page 2 of 6 2 Reasons for determination 2.1 Was the FSP entitled to deny the applicant’s claim ? Application of policy depends on the cause of damage The applicant is required to show, on the balance of probabilities, she has suffered a loss caused by a risk insured against under the policy. If the applicant is able to establish a loss caused by a risk insured against under the policy, then the onus shifts to the FSP to show, on the balance of probabilities, it is entitled to rely on an exclusion under the policy to deny the claim. The policy provides cover for loss or damage caused by the events listed in the policy (including water leaking or escaping from pipes), subject to a number of exclusions (including loss or damage arising from tree roots). The applicant started to notice cracking damage within the property over a period of 18 months. She engaged a structural engineer, who considered the cause to be water issues due to the actions of trees. Following the structural engineer‟s advice, the applicant arranged for the trees to be removed. She also asked her local Council to remove adjacent street trees but it refused on the basis those trees had not contributed to the damage. The applicant lodged a claim for the damage with the FSP. The FSP arranged for the damage to be assessed by its panel builder (DW), who in turn appointed a structural engineer (GC). GC considered the probable cause of the damage to the applicant‟s home to be leakage of the rainwater pipes into the foundations as a result of increased pressure due to a blockage to the stormwater pipe outside the home. GC thought the blockage in the stormwater pipe might be due to root intrusion or debris. GC believed the leaks from the rainwater pipes caused the soils to swell, which in turn moved the walls beyond the limits of the brick work (generating cracks). Given GC found the cracking damage to be due to water leaking from rainwater pipes at the property causing the soils to swell, the panel is satisfied the applicant has established a loss caused by a risk insured against under the policy. Accordingly, the FSP bears the onus of establishing that, on the balance of probabilities, it is entitled to rely on a policy exclusion to deny the a pplicant‟s claim. The FSP says it is not liable for the applicant‟s claim because the proximate cause of the leaking pipes was a blockage in the storm water pipe on the outside of the property caused by tree roots. The FSP says the policy excludes leaking from a stormwater pipe off the site and also excludes loss or damage arising from tree roots. In order to establish an exclusion applies, the FSP must show that the proximate cause of the damage to the Applicant ‟s property (that is, the real, effective or dominant cause) was one or more of these excluded factors. Case No: 475578 Determination Page 3 of 6 Evidence indicates leaks occurred on the site Part of the FSP‟s argument is that it is not liable for the claimed damage because the policy excludes loss or damage caused by water leaking or escaping from a stormwater pipe “off your site”. In this case, whilst the blockage in the stormwater pipe responsible for the increased pressure in the plumbing system was off site, the available evidence suggests the water responsible for the damage came from leaks in the pipes adjacent to the foundations of the home. As the leaking pipes were adjacent to the foundations, they were clearly situated on the site and not off it. Furthermore, there is nothing to suggest any leaking from the pipe off site caused or contributed to the damage. Accordingly, the FSP is not entitled to rely on the quoted exclusion as the water responsible for the damage escaped or leaked from pipes situated on the site. Evidence does not confirm blockage due to tree roots Following receipt of GC‟s report, the FSP arranged for the plumbing at the property to be inspected by EP. EP noted a 90mm PVC stormwater pipe was “ crushed from a tree at the footpath ” . EP was unable to identify any other significant issues with the plumbing system at the property that might be responsible for the loss. The FSP says it is not liable for the applicant‟s loss as the blockage that caused the increased pressure in the plumbing system (which in turn caused the leaks), was the result of tree roots. The FSP relies on the policy exclusion relating to loss or damage arising from tree roots. The Panel has reviewed the reports of GC and EP. Whilst GC indicates the probable cause of the damage is the blockage, he does not confirm the actual cause of the blockage and instead suggests it “may be root intrusion, or debris collection”. EP says the pipe has been “crushed at the tree area” and “crushed from a tree” , but there is no specific reference to the blockage being due to „tree roots‟ . The only reference to „tree roots‟ relates to the pipe needing to be replaced “where the tree root has crushed the pipe”. Although the applicant ‟s engineer (CC) says the plumber put a camera down the pipe and found it was blocked by tree roots, this comment came from the applicant rather than the plumber direct. The Panel notes despite the use of a CCTV camera there is no photographic or other evidence showing tree roots blocking the pipe. Whilst it might have been tree roots that crushed the pipe (although the evidence in this regard is not conclusive), there is nothing to confirm tree roots caused the blockage. In the absence of this evidence, it is possible the blockage was due to other debris (as opined by GC), particularly as EP has not specifically commented on the blockage and instead refers to the pipe being crushed. Case No: 475578 Determination Page 4 of 6 In order to rely on the policy exclusion for loss or damage arising from tree roots, the FSP must demonstrate tree roots were the proximate cause of the damage. Although the Panel is satisfied there was a blockage within the pipes, the evidence does not confirm tree roots to be the cause of the blockage. Accordingly, the FSP is not entitled to rely on the tree roots exclusion to deny the ap plicant‟s claim . Case No: 475578 Determination Page 5 of 6 3 Supporting information 3.1 Key documents Record Key points FSP’s engineer (GC) Report 17 August 2016  The house has numerous severe cracks in the internal and external walls.  Turned off all the taps in the house and observed the water meter stopped which suggests there are not existing leaks in the plumbing supply pipes.  Ran garden hose int o downpipe at western corner of house for 10 mins. After 5 mins water leaked out of the pipe at the entry point to the ground indicating some positive pressure in the pipe.  Ran hose into the downpipe on the Eastern corner, after 5 mins a slow trickle of water started flowing from the exit point on the street. After 10 mins, water appeared on the footpath over the path of the stormwater pipe.  Believe the existing storm water pipe is substantially blocked downstream of the footpath bet ween the footpath and the street.  Whenever a house stands for this many years with relatively little trouble a nd then begins cracking, it is a sign that a significant change has occurred.  Damage is consistent with differential foundation movements. Since there has been no change to the loadings in the house, changes to the moisture content of the soils below the foundations is highly likely.  Believe the storm water system is leaking wat er into the foundation zone of the house and has substantially changed the moisture profile under the foundations.  Believe pipes are most likely broken or badly leaking in a numbe r of locations across the front.  The very small volume of water flowing from the stormwater exit to the street indicates the storm water pipe is substantially blocked, allowing hydrostatic pressure to build up in the lower parts of the storm water pipes. This pressure would greatly increase the volume of water which will leak from the storm water pipes under the foundations.  The cause and location of the original leak is not known – common suspects are tree roots, corrosion and soil movement.  The blockage of the pipe near the footpath did place additional pressure on the pipe underground which then caused leaks, in a pipe possibly already weakened by corrosion or perhaps never properly installed.  Tree removed by the applicant was too small to do more than just localised damage to the nearest wall. It would have had little if any effect on the house. Case No: 475578 Determination Page 6 of 6  Probable cause of the damage is blockage to the stormwater pipe in the vicinity of the footpath outside her home, causing pressure to build up in the storm water line and subsequent leakage of the rainwater pipes to a location near the footings of the house, resulting in a change to the soil profile resulting in swelling and differential movement beyond the limits of the brickworks resulting in subs tantial cracks.  The cause of the blockage may be tree roots or debris collection. FSP’s plumber ( EP ) Report 16 November 2016  Pipe in footpath will need to be replaced where the tree root has crushed the pipe.  Storm water 90mm PV C was crushed from a tree in the footpath. The camera was unable to pass.  Stormwater line need to be sealed LHS downpipe to be replaced in footpath area. Pipe crushed at the tree area camera unable to pass.  CCTV footage shows camera in line from street ker b towards house – 2.5m from kerb pipe crushed from tree in foot path. Camera unable to pass.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.