Text of the determination
Determination
Case No: 475520 Determination Page 1 of 10
Case number: 475520 19 April 2018
1 Overview
1.1 Dispute
The applicant held a home and contents insurance policy with the financial services
provider (FSP). On 21 March 2016 he lodged a claim for damage sustained to his
home as a result of a burst pipe underneath the home.
The FSP subsequently declined the applicant’s claim and says the damage to the
home was caused by:
settling, shrinkage and any movement of earth
faulty workmanship or design.
Insofar as there may have been damage sustained by the leaking pipe, the FSP says
given the ‘ Wayne T ank principle’ the relevant exclusions apply.
1.2 Issues and key findings
Is the FSP entitled to decline the applicant’s claim ?
There is no dispute that the damage sustained to the applicant’s property was
accidental damage that falls within the terms of the policy.
The panel is satisfied that the damage to the east side of the house was proximately
caused by the leaking pipe. The panel is satisfied that the FSP is liable to meet the
applicant’s claim for damage to the east side of the house.
Otherwise the balance of the damage sustained to the applicant’s property was due
to a combination of ground movement and faulty workmanship, which is excluded
from cover.
1.3 Determination
This determination is partially in favour of the applicant.
The FSP is to settle the applicant’s claim for damage to the east side of the house in
the sum of $10,000. No interest is payable on the cash settlement.
Further, the FSP is to cont ribute up to $2,000 towards the cost of the applicant’s
engineering expert report subject to the applicant providing relevant invoices.
The FSP is otherwise entitled to decline the applicant’s claim in accordance with the
terms and conditions of the policy.
Case No: 475520 Determination Page 2 of 10
2 Reasons for determination
There has been a full exchange of material between the parties and each party has
had the opportunity of addressing the issues that arise from the information
exchanged.
Due to the complexities of the issues involved in this dispute, the matter has been
referred to a panel for determination. In reaching this determination the panel has
taken into account all relevant information including all expert reports provided by the
parties.
The determination is based on what is fair in all the circumstances, having regard to
the relevant legal principles, terms of the policy, good industry practice including
codes of practice and prior determinations where applicable.
2.1 Was the FSP entitled to decline the applicant’s claim ?
Policy covers accidental damage
The applicant’s policy is an accidental damage policy which provides cover for
unforeseen and unintended damage. The onus is therefore on the applicant to
establish the loss or damage to his property was accidental damage.
Circumstances of loss
The applicant says that the damage was sustained to his property over the summer
of 2015/16 when a water pipe broke under his property.
An invoice from D Plumbing dated 4 April 2016 covering the cost of repair of the
burst pipe notes that there was a considerable amount of water that had been leaking
under the house on the east side. A copy of the applicant’s water bill shows a
significant spike in water usage in the January and April quarters of 2016.
There is no dispute that a burst pipe leaked a significant amount of water under the
applicant’s property over a period of time in early 2016. The applicant says he
noticed cracks and damage appearing to the property after the leak was discovered
and that the building movement and damage continued after the pipe was repaired.
There is no suggestion the applicant knowingly caused or contributed to the property
damage. The panel is satisfied the damage is accidental.
In these circumstances, the FSP bears the onus of establishing, on the balance of
probabilities, it is entitled to rely on an exclusion under the policy, or is otherwise
entitled to deny the claim.
FSP is required to demonstrate loss was excluded
The FSP, in its Notice of Response has relied on policy exclusions relating to:
loss or damage as a result of, or caused by settling, or any movement of earth
loss or damage as a result of, or caused by faulty workmanship or design.
Whilst it does not dispute that the leak from the burst pipe located underneath the
east side of the house has exacerbated the damage to this area, the FSP says this
Case No: 475520 Determination Page 3 of 10
did not cause the entire damage. It relies upon the Wayne Tank principle to argue
that since ground movement and faulty workmanship or design were excluded from
cover, it is entitled to deny payment of the claim in full.
The onus is on the FSP to establish the application of the exclusions and the Wayne
Tank principle.
Property suffered damage in 2010/2011
There is no dispute that the applicant’s property was damaged during heavy rain in
2010/2011 at the end of a long drought. A claim was accepted by the FSP and cash
settled.
The FSP’s engineering report provided by HCE noted at that time that t here was
significant cracking throughout the house, the floors were out of level and that an
inspection of the concrete stumps identified gaps between the top of the stumps and
the timber bearers, especially along the east side of the property.
HCE concluded at that time that the damage and movement was typical of problems
that occur due to differential settlement of the stumps associated with problems with
the storm water drains.
The panel notes HCE recommended at that time that when re-levelling is carried out,
new stumps should be provided where there are out of level stumps, particularly with
the rear north-east corner of the house.
The applicant does not dispute the findings from 2011, nor does the applicant dispute
that that claim was cash settled.
The FSP provided a report from BP. BP identified substantial foundation movement
on the north-east side causing cracking to the internal plaster. BP also identified that
the previous relevelling of the property following the 2011 event was not compliant
with relevant Australian Building Standards.
HCE considered that the leaking pipe would have contributed to the damage to the
east side of the house where the pipe was located but otherwise the house was
subject to movement due to seasonal change as evidence by the repacking of the
stumps. The panel notes HCE’s concern regarding the height of the timber packers
used to pack the stumps following the 2011 claim.
The applicant’s engineer, DCE considers that the movement of the applicant’s
property is associated with the residual effects of the 2011 inundation, the abnormally
moist soil as a result of the leaking pipes and the impact of tree roots.
DCE also noted exceptionally large chocks had been used in relevelling the stumps
in 2011 and some of the stumps were leaning.
The panel has viewed the photographs provided of the sub-floor area and in
particular, of the stumps. The panel notes that there are considerable gaps between
some of the stumps, the chocks used to re-level some areas of the house appear
oversized and some of the stumps are leaning.
Case No: 475520 Determination Page 4 of 10
The panel accepts the comments by HCE that the use of large chocks or packers is
not good practice. The panel also notes HCE’s comments that the previous
restumping of the house did not appear to replace any of the leaning stumps.
The panel accepts that, to the extent that any damage is associated with the re-
levelling work carried out in 2011 or between 2011 and 2016, such damage would be
excluded from cover due to faulty or defective workmanship.
East side of the property damaged as a result of leaking pipe
Whilst the reports from HCE and DCE differ, both engineers agree that the
inundation caused by the leaking pipe under the east side of the property has
affected the foundation material on the east side of the property at the very least.
HCE in its supplementary report considered that the leak had affected the ensuite,
walk in robe, main bedroom and bedroom 2 located on the east side of the house.
Expert reports differ as to cause of the balance of the damage
HCE and DCE differ however as to the cause of the balance of the damage.
HCE, whilst acknowledging that it had not conducted any soil testing , considered the
2016 leaking pipe had not caused soil swelling to the affected west side of the house,
but that soil shrinkage had occurred due to seasonal change.
DCE on the other hand considered there were three influences affecting the floor
movement, namely:
the bearing failure along the northern half of the eastern side of the building,
caused by the leaking pipes and around the north-western and south-western
corners of the house, likely due to the residual effects of the 2011 claim
soil swelling affecting the western side of the house likely due to residual effects
of the 2011 claim
soil shrinkage, caused by the drying effect of tree roots.
It is not necessary for the purpose of this dispute to determine which experts’ opinion
is correct as both experts appear to agree that the impact affecting the north-western
and south-western corners of the house and the western side of the house was not
caused solely by the leaking pipe in 2016 but due to other causes which are
excluded under the terms of the policy.
Wayne Tank principle
The Wayne Tank principle applies where there are two or more concurrent and
equally proximate causes of damage, one of which may be an insured event and the
others which may be excluded. In these circumstances, where the causes are of
equal proximity, that is, are of equal effect, then the exclusion will apply to defeat the
claim.
Insofar as there are differing opinions from the engineers, the panel accepts that
there are likely to be multiple proximate causes of damage to the western side of the
house.
Case No: 475520 Determination Page 5 of 10
The panel accepts that the Wayne Tank principle would apply to this damage as it is
satisfied that most likely this damage was caused by a combination of factors,
including faulty design and or workmanship and or ground movement, both of which
are excluded from cover under the terms of the policy.
The panel however is not satisfied that the Wayne Tank principle should apply to
defeat the applicant’s claim with respect to damage to the eastern side of the
property.
The panel accepts that there may have been faulty design and workmanship involved
in the re-levelling of that side of the house following the 2011 event. However, the
panel is satisfied that the proximate, that is, the dominant or effective cause of the
damage to the eastern side of the property was the saturation of the soil caused by
the burst pipe on the eastern side of the property. The panel is satisfied that the
reports from both HCE and DCE support such a finding.
FSP to cash settle applicant’s claim for costs to repair eastern side of house
The FSP has provided a quotation for the cost of repairs to the eastern side of the
house from BP, totalling $7,300.
The scope of works includes:
Re-level floor area by packing over the top of existing stumps .
Plaster repair and paint ceilings and walls affected by relevelling.
Remove and replace two SQM to the ensuite vanity units/back tiles .
Ensure doors are operational.
The scope of works is designed to cover damage to the ensuite, walk in robe, main
bedroom and front bedroom, in accordance with the findings of HCE.
The panel is concerned as to the proposed method of packing over the top of the
existing stumps given the comments made by both engineers with respect to the
previous re- levelling of the property. In the panel’s view, it would be more appropriate
that the existing stumps be replaced.
The panel considers that a further allowance should be made to cover the potential
costs of replacing the existing stumps on the eastern side of the property, to allow for
the floor area to be re-levelled.
The panel determines it would be fair in the circumstances for the FSP to pay the
total sum of $10,000 to settle the applicant’s claim for damage to the eastern side of
the property. No interest is payable on this amount.
Applicant entitled to contribution towards costs of obtaining engineering
report
Under paragraph 9.4 of the Terms of Reference, FOS can determine that an FSP
contribute up to $3,000 to professional costs incurred by an applicant in bringing a
matter before FOS.
Case No: 475520 Determination Page 6 of 10
The panel accepts that in the current dispute the applicant reasonably needed the
assistance of the engineer. The report from DCE has been of assistance in resolving
the issues in dispute and allowing the applicant to establish his case.
In determining the extent of any contribution, FOS needs to determine what is fair in
all the circumstances. Given the nature of this dispute, the panel is satisfied that it is
fair that the FSP contribute up to $2,000 to the applicant’s costs of o btaining the
engineering report from DCE, subject to the applicant providing copies of the relevant
invoices.
Case No: 475520 Determination Page 7 of 10
3 Supporting information
3.1 Expert reports
Record Key points
FSP’s expert ( H )
Report
7 - 04 - 2011
Floor levels suggested western side of house up to 20mm out of
level
Levels suggested eastern side of house up to 80mm out
Subfloor area damp on eastern side
Inspection of concret e stumps showed gaps between top of stumps
and timber bearers on eastern side
Out of level stumps to north - eastern side of property
‘ CONCLUSIONS
The cracking and movement of the house, particularly along the e ast
side, is typical of problems that occur due to differential settlement of
the stumps. Differe ntial settlement can occur of the stumps due to
changes in moisture content of the foundation material.
[…]
Gaps were evident between the stumps and the bearers in several
locations which would indicate that movement has been occurring of
the stumps in these areas.
Out - of - level was also evident of several of the stumps, however, in our
opinion, this problem would be related to the method of construction
an d installation of the stumps and not related to the water going
underneat h the house.
Therefore, in our opinion, the movement and problems occurring,
particularly along the east side of the house, has resulted due to the
problems with the stormwater drain at the front of the property.
RECOMMENDATIONS
[…]
Re - levelling can be carried out of the existing stumps along the east
side of the house. This re - levelling should be to only feather the
levels into adjoining areas and should not be to re - level the house
b ack to a zero datum.
Once re - levelling has been carried out then repairs can be carried
out to the cracking and movement in the house prior to the effected
[sic] areas being re - painted.
We would also recommend that while re - levelling is being carried out o f
the stumps new stumps should be provided where out - of - level is
occurring in stumps, particularly to the rear north east corner of the
house. […]’
FSP’s expert (B)
Report
18 - 04 - 2016
‘ Resultant Damage
Upon inspection we found the North and eastern sides o f the house
have substantial foundation movement causing cracking to the internal
plaster linings and wall tiles dislodging in the ensuite.
Case No: 475520 Determination Page 8 of 10
Cause of Damage
The cause of the damage is believed to be from the water inundating
the subfloor from these leaking pipes however we noticed that when
the house was re - levelled during previous Insurance repairs oversized
packing of the stumps has occurred which is larger than what is
required under Australian Building Standards. Re - levelling of the home
is not an option due to the already existing large packing. We are
uncertain that the water has been the main contributor to this resultant
damage and recommend a specialist be engaged to determine the
cause of damage.’ [sic]
FSP’s expert (H)
Report
11 - 07 - 2016
‘During ou r site inspection floor levels were taken on the house using
the floor level at the chimney midway along the west wall. This showed
that up to 30mm to 50mm out of level was occurring in the family
room/meals area particularly at the north end. Out of level of up to
90mm was measured along the east side of the house. The greatest
movement was occurring in the ensuite and walk - in robe as well as to
the front bedroom in the south - east corner.
Generally the remaining areas of the house showed levels between
20m m and 30mm.
[…]
Several amount of timber packers have been used to re - level the
stumps. In some cases gaps occur between the timber packers and
timber bearers.
In a large number of cases leaning and out of level was evident of the
stumps and in some cases the lean was so great that the stumps were
not supporting the bearers. Movement had also occurred of the timber
packers.
[…]
Previous problems have been occurring with movement in the house
and it was indicated that re levelling was carried out of the hou se
following our initial site inspection in 2011. It is not clear how level the
house was made during this re - levelling. Our office is concerned
regarding the height of the timber packers used to pack the stumps.
Normally packing of stumps is between 30mm and 40mm. In this case
most of the packers are around up to 120mm. In our opinion this is not
good practice to have large packers.
[…]
Considerable amount of out of level is also occurring of the timber
stumps. This problem was obs erved during our initial site inspection
and it would appear that the previous re - stumping of the house did not
replace any of the leaning stumps.
[…]
It should be noted that considerable amount of movement is occurring
in the north - west corner and in our opinion this problem would be
related to the dry summer and would not be related to the leaking
water pipe as the water would not extend up to this area of the house
as it is up hill from where the leak occurred.
Therefore, in our opinion, the movement in the ensuite, walk - in robe,
Case No: 475520 Determination Page 9 of 10
main bedroom and front bedroom in the south east corner has resulted
due to the following factors.
The last summer being a very dry summer with long periods without
rain.
The leaking water pipe on the east side of the house.
Inappropriat e re - levelling of the house since our initial site
inspection.
In our opinion the cracking to ot her areas of the house are not related
to the recent leaking water pipe.’
Applicant’s expert (D)
Report
4 - 07 - 2017
three types of influences affecting floor movem ent and damage to
the building, being:
i. Bearing failure along the northern half of the eastern side of the
building caused by the leaking pipe and around the north
western and south western corners of the house, likely residual
effect of the 2011 claim.
ii. Soil swelling affecting the western side of the hous e, also likely
residual effect of the 2011 claim.
iii. Soil shrinkage caused by the drying effect of tree roots from the
large deciduous tree to the south east of the building.
Suggests H reports had wrong int erpretations and contradictions as
a result of not preparing contour maps and soil tests
H report suggests dry climatic conditions caused floor movement
around the north - west corner of the building whereas D’s soil testing
showed the soil conditions to be very damp
H report did not identify a large tree to the sout h - east which D
considered responsible for some footing movement
H’s report provides contradictory information
H states poor re - levelling practices caused building problems ,
whereas D suggests bear ing failure from the leaking pipe cause d
floor movement and damage to the northern half of the eastern side
of the building
H recommended the floor should be mainly re - levelled even though
it had been identified that there were floor level differences of u p to
80 mm and the settlement offer given by the insurers was only
sufficient for that purpose
H incorrectly classifi ed soil at the site
H failed to inform additional floor movement could be expected in
the Highly Reactive soils
There is no indication dry seasonal conditions affected the site
A part from a corner affected by a tree, the site is moist to abnormal
depth due to pipe leak and the residual effects of the 2011 claim
The applicant use d large chocks based on rec ommendations in the
H report
H’s report was not supplied to the applicant at that time
The FSP’s settlement was issued with no instructions on what it was
intended for, and was not sufficient to do re - stumping
Packing is not the cause of footing movement
The cause of footing movement is from the leaking pipe, residual
effect s of the 2011 claim and a tree to the south east corner of the
Case No: 475520 Determination Page 10 of 10
building
FSP’s expert (H)
Report
9 - 0 8 - 2017
Soil testing not undertak en, based on geological maps of area
Both D and H reports confirm large amount of sit e movement can
occur in foundation material
No significant localised settlement obs erved at the property from
tree during H’s inspections, and no reference to tree roots in D bore
hole examination
Difference in levels bet ween 2011 and 2016 inspections diff ered by
between 10mm to 15mm
Significant amount of out of level in 2011 and no significant change
to 2016 except in robe and ensuite areas
Most large chocks were in place during 2011 inspection and no
significant change to 2016
Uncertain what re - leveling w orks conducted as the sub - floor
condition was similar from 2011 to 2016 inspections
D findings only based on inspection from June 2017, does not
consider or explain influences from 2011
Soil testing was undertaken in winter when conditions can be
damper
Damage is not due to bearing failure as no significant movement
occurred bet ween 2011 to 2016, evidenced by a la ck of continuing
movement in the footings .
3.2 Relevant policy wording
Accidental Damage cover
If you have chos en Accidental Damage Home Ins urance, we will cover your buildings or
contents for accident al loss or damage.
[…]
Exclusions to your cover
Any cover we provide is subject to the following exclusions.
[…]
We will NOT cover any loss or damage as a result of, or caused by
• settling, shrinkage o r any movement of eart h
[…]
• a defect in an item, structural defects, or faulty workmanship or design
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.