Storm claim for pool and paver damage declined under hydrostatic pressure and gradual deterioration exclusions
Text of the determination
Determination
Case No: 475424 Determination Page 1 of 4
Case number: 475424 13 February 2018
1 Overview
1.1 Dispute
The applicants lodged a claim under their home insurance policy with the financial
services provider (FSP) for damage to their in-ground swimming pool and
surrounding pavers. The applicants consider the damage was caused by a storm on
20 March 2016.
The FSP denied the claim on the basis that the damage was not caused by the storm
but by factors which are excluded under the policy such as hydrostatic pressure and
gradual deterioration.
The FOS case manager provided the parties with a recommendation on the issues in
dispute. The recommendation was in favour of the FSP. A copy of the
recommendation is attached to this determination.
1.2 Issues and key findings
Were the findings of the recommendation correct?
The findings contained in the recommendation were correct and are adopted in this
determination. Further submissions provided after the recommendation have been
considered but do not warrant changing the outcome of the recommendation.
Is the FSP liable for the damage to the pool and pavers?
The FSP is not liable for the damage to the pool and pavers because the damage
was not caused by the storm on 20 March 2016 (or by any other event insured
against under the policy). The damage was caused by factors which are excluded
from cover.
1.3 Determination
This determination is in favour of the FSP.
I agree with the case manager‟s reasons for the recommendation and the
recommended outcome.
The FSP is not re quired to accept the applicants‟ claim.
Case No: 475424 Determination Page 2 of 4
2 Reasons for determination
2.1 Were the findings in the recommendation correct?
I have decided this dispute based on what is fair in all the circumstances. I have had
regard to the relevant law, good industry practice, codes of practice and previous
FOS decisions.
In reaching my decision, I have taken into account all the material submitted by the
parties, both before and after the recommendation. I am satisfied that the
documentation I have relied on has been provided to both parties.
I am satisfied that the case manager‟s recommendation contains an accurate
summary of the dispute, the issues to be determined, any applicable paragraphs of
the Terms of Reference and any relevant law.
2.2 Is the FSP liable for the damage to the pool and pavers ?
FSP’s liability depends on proximate cause of damage
The applicants‟ po licy provides cover for damage to their property caused by a storm
(including the sudden, excessive run-off of water as the direct result of a storm in the
local area).
However, the policy contains general exclusions for damage caused by:
hydrostatic pressure (including damage to swimming pools)
faulty design or workmanship
the applicants‟ failure to maintain the property in good condition
gradual deterioration or wear and tear.
The applicants say that their in ground fibreglass pool „popped out‟ of the g round and
the pavers adjacent to the pool subsided as a result of the rainfall run-off which
affected their rear yard during the storm in March 2016 . The applicant says there was
no damage to the pool or pavers prior to the storm.
The FSP disputes that the damage to the applicants‟ pool and pavers was caused by
the storm. The FSP says the pool and pavers had not been properly maintained over
a number of years and deteriorated gradually over time.
Damage caused in this manner is not covered under the policy.
Accordingly, in order to determine the FSP‟s liability for the claimed damage, it is
necessary to identify the proximate cause of the damage.
It is well established at law that the proximate cause of a loss is not necessarily the
first (or the last) or the sole cause of the loss. It is the effective or dominant or
operative cause.
In any particular case, the proximate cause of the loss is a question of fact to be
determined based on the surrounding circumstances. Where there are several
causes operating, each must be examined for the qualities of predominance and
efficacy in relation to the resultant damage.
Case No: 475424 Determination Page 3 of 4
Damage to pool was caused by excluded factors
Having carefully reviewed the available information (including the various reports
provided by the parties), I am satisfied that the proximate cause of the damage to the
applicants‟ pool and pavers was not the storm in March 2016, but factors which are
excluded from cover under the policy.
Both of the engineers (EB and MP) engaged by the parties concluded that the pool
had been damaged due to the effects of hydrostatic forces as a result of water
entering the sand-filled area surrounding the pool.
Both EB and MP noted that the likelihood of this kind of damage occurring is
increased where the pool is not kept full and where a reinforced concrete base is not
installed around the pool (which MP advised was a requirement of the manufacturer).
The FSP‟s engineer (MP) considered that the entry of water which caused the pool
shell to buckle occurred over an extended period of time prior to the storm in March
2016. MP referred to photographs of the pool taken in the several years prior to the
storm which appear to show it partially empty and/or filled with discoloured water.
In contrast, the applicants‟ engineer (EB) advised that the pool had been damaged
due to the effects of surface run-off following heavy rainfall experienced during a
severe storm in June 2016.
The available information indicates that there was approximately 57.8 millimetres of
rainfall in th e vicinity of the applicants‟ property during the storm on or around 20
March 2016.
The FSP‟s engineer (MP) advised that this amount of rain fall was not indicative of an
extraordinary storm event. The applicants‟ engineer did not consider the likely effec ts
of the rainfall experienced during the March 2016 storm, as he mistakenly concluded
that the damage had been caused by a storm in June 2016.
Based on the available information, I am satisfied that the proximate cause of the
damage to the pool was hydrostatic pressure and not the storm in March 2016.
In reaching this conclusion, I have had particular regard to:
the volume of rainfall experienced during the storm (taking into account the
applicants‟ comments that the bulk of this rainfall was concentrated in their rear
yard over a period of several hours only)
the evidence that water had been entering the area around the pool over an
extended period of time (as shown by the corrosion to the metal fixings around
the perimeter of the pool)
the absence of a reinforced concrete rim around the pool, which would have
reduced the potential risk of damage due to hydrostatic forces
the comments made in several of the expert reports that the pool was partially
empty at the time of the storm in March 2016, which exacerbated the risk of
damage due to hydrostatic pressure.
Case No: 475424 Determination Page 4 of 4
Damage to pavers was caused by gradual deterioration
Based on the available information, I consider the subsidence of the pavers on the
north side of the pool was caused by gradual deterioration due to water entering the
fill material under the pavers over an extended period of time.
The FSP‟s engineer (MP) advised that water entry would have occurred due to the
effects of groundwater and surface run-off during regular rainfall events (as well as in
the ordinary course of use of usage of the pool). As outlined above, the corrosion
evident to the metal fixings supports MP‟s conclusion.
Further, the photographs taken by the FSP‟s builder (AJ) shortly after the storm in
March 2016 clearly show grass growing in between the subsided pavers. This further
supports MP‟s conclusion that the damage to the pavers occurred prior to the storm
on 20 March 2016.
FSP is not liable for applicants’ claim
For the reasons outlined above, I am satisfied that the damage to the pool and
pavers was caused by factors which are excluded from cover under the policy.
Accordingly, the FSP is not liable for the applicants‟ claim.
Recommendation
Case No: 475424 Recommendation Page 1 of 6
Case number: 475424 7 July 2017
3 Overview
3.1 Dispute
The applicants lodged a home building and contents claim, stating their swimming
pool and surrounding pavers were damaged by severe storms in March 2016.
The FSP assessed the damage and subsequently declined the claim. In doing so,
the FSP experts say the damage was caused by hydrostatic pressure and gradual
deterioration, which are factors the policy expressly excludes.
The applicants dispute the FSP‟s denial of their c laim. They say the damage
occurred overnight during heavy rains and there was no movement of the pavers
before this storm. Additionally the applicant says they carried out normal
maintenance on the pool. They want the FSP to accept the claim.
3.2 Issues and key findings
Is the FSP entitled to decline the applicants’ claim ?
The available information establishes that:
on the balance of probabilities, the pool was damaged by hydrostatic pressure
that arose due to moisture in and gradual subsidence of the surrounding sand
the pavers were also damaged by gradual subsidence
damage caused by hydrostatic pressure and/or gradual subsidence is expressly
excluded from cover.
Accordingly, the FSP is entitled to decline the applicant‟s claim.
3.3 Recommendation
This recommendation is in favour of the FSP.
The FSP is not required to accept the applicants‟ claim.
Case No: 475424 Recommendation Page 2 of 6
4 Reasons for recommendation
4.1 Is the FSP entitled to decline the applicants’ claim?
Policy provides cover for storm damage subject to exclusions
The applicants ‟ home building and contents insurance policy provides cover for listed
events subject to certain terms, conditions and exclusions. One the listed events is
damage caused by storms, including „sudden, excessive run -off water as a direct
result of a storm i n [the applicants‟] local area‟ .
The FSP‟s product disclosure s tatement (PDS) details the policy‟s terms, conditions
and exclusions. It excludes payment for damage that occurs in the following
circumstances:
What we don’t cover
Loss, damage, injury or death arising from:
- subsidence or landslide unless it happens immediately as a result of an earthquake or
explosion
- hydrostatic pressure including loss or damage to swimming pools or similar structures.
Maintaining and occupying your home
We don’t cover loss, damage, injury or death arising from:
- faulty design or workmanship
- you not maintaining your home in good condition. This means your home must be
watertight, structurally sound, secure and well maintained any person who is acting with
your express or implied consent.
Applicants have established a prima facie claim
The applicants have the responsibility of establishing, on the balance of probabilities,
they have suffered a loss caused by an event insured under the policy. Only once the
applicants have established that does the onus shift to the FSP to establish an
exclusion applies to defeat the claim.
The applicants say they have resided in the property since January 2001 and
regularly maintain the pool. The applicants also say they did not identify any damage
to the pool and/or the pavers before the March 2016 storm event. Additionally it is not
in dispute that a storm event occurred on 20 March 2016.
In such circumstances, I am satisfied the applicants have established a prima facie
claim.
Given this, it falls to the FSP to show on the balance of probabilities that it is entitled
to rely on an exclusion under the policy, or is otherwise entitled to deny the claim.
Pool and pavers were damaged by hydrostatic pressure and subsidence
The applicants lodged a claim stating the damage occurred when their home
experienced severe storms on 20 March 2016. They strongly believe the damage
Case No: 475424 Recommendation Page 3 of 6
occurred overnight during the storm and the stormwater run-off caused the paving
concourse to collapse, resulting in the movement o f the pool.
The FSP received the claim and initially arranged for a builder (AJ) to establish the
cause of loss. The FSP subsequently engaged an engineer (MP) and both experts
state the pool was damaged by hydrostatic pressure causing the shell to move and
pop, due to:
the pool being empty
subsidence of the surrounding sand and pavers over time.
Relevantly, MP stated subsidence occurred gradually, when:
groundwater and runoff have likely contributed to moisture seeping through to the backed sand
behind the pool’s northern wall, causing the sand to become saturated and settle, causing the pool’s
pavers to subside.
The FSP notes there is grass growing through and across cracked pavers in
photographs taken in March 2016. It argues this much grass could not have grown if
the pavers were first cracked during the storm on 20 March 2016. Additionally the
FSP says the rainfall during the storm event was, while “relatively heavy rain” is not
an unusual amount of rain or an extraordinary rain storm event”.
The FSP‟ s reports, being from separate experts, were consistent in their
observations and conclusions. I am satisfied that the pool was, on the balance of
probabilities, damaged when the shell was popped by hydrostatic pressure that arose
due to moisture in and gradual subsidence of the surrounding sand. I am also
satisfied this subsidence has damaged the pavers over time.
This means the FSP has established exclusions that defeat the applicants‟ claim.
Applicants’ expert reports support FSP’s position
In forming the above view, I have considered the two expert reports (ST and EB)
provided by the applicants. These state that the damage was from a single storm,
due to:
Expert Damage causation
ST extra heavy flooding rain while the pool was empty for cleaning purpos es
the pool being only partially full at the time of the storm event
sudden pressure changes around the pool shell, occurring with storm atmosphere and
run - off, even though the hydrostatic valve was working
EB storm events on 5 - 6 June 2016
run - off which undermined and collapsed the pavers, lifted the pool shell and moved the
surrounding sand, so that when the pool shell settled again it buckled
ST is managing director of a pool and spa specialist consultancy, who has seen the
pool pre and post damage. However, his report states that pool was empty, which
supports the FSP‟s argument that hydrostatic pressure , namely the pressure
imbalance inside compared with outside a pool‟s shell , caused the damage.
While noting EB is an engineer, I have given his report little weight. This is
predominately because it:
Case No: 475424 Recommendation Page 4 of 6
incorrectly suggests the damage occurred due to a storm event in June 2016 (as
opposed to March 2016)
is heavily reliant upon advice/observations provided by the applicants
relies upon a site inspection in October 2016, some eight months after the storm
event.
In any event, in my view, EB‟s report also supports the FSP‟s experts‟ conclusions. It
identifies storm run-off, pressure from the surrounding sand and the pool being
empty as the causes of damage.
For the reasons set above, I find the applicants‟ submissions support the FSP‟s
position.
FSP is entitled to decline the applicants’ claim
On the balance of probabilities I consider the damage to the pool and pavers were
caused by hydrostatic pressure and gradual subsidence. Given damage caused by
these factors are excluded from cover, it follows the FSP is entitled to deny the claim.
The FSP also alleges a lack of maintenance caused the damage. However given I
find the FSP is entitled to deny the claim (for the above reasons), it is not necessary
for me to consider whether a lack of maintenance caused or contributed to the
damage.
Case No: 475424 Recommendation Page 5 of 6
5 Supporting information
5.1 Expert reports
Reports on cause of damage
Date Action
FSP’s report
31 - 06 - 2016
Damage report, AJ, engineer
damage to the swimming pool had caused by hydrostatic
pressure due to being empty and due to subsidence of the
surrounding soil and pavers over time
single storm event had not caused the damage being claimed
Applicants’ report
0 7 - 07 - 2016
Cons ultant‟s report, ST, managing
director, pool and spa specialist
consultancy
failure of the nort h side of the pool is due to extra heavy
flooding rain while the pool was empty for cleaning purposes
FSP’s report
04 - 05 - 2016
Report, MP, engineer
damage l ikely gradual and not related to a one off storm event
around 21 March 2016 and predates this storm event
no evidence to suggest that damage caused by a single wind
and rain storm event
c ause of pool paver subsidence cannot be attributed to any
one factor, but rat her to a combination of factors
g roundwater and runoff likely contribut ed to moisture seeping
through to backed sand behind northern wall, causing sand to
become saturated and settle, causin g pool‟s pavers to
subside
r usting of metal fixing support ing northern pool wall suggests
there long standing issues with groundwater, runoff and
moisture beside northern pool wall, where the pool pavers
subsided
Applicants’ report
29 - 10 - 2016
Engineer‟s report, EB, engineer
pool was only partially full
recent East Coast Low storm events on the 5 - 6 June 2016
caused localised overland flooding to swimming pool shell
this event caused overland flows to undermine and collapse
the paving concourse
ground water level rose around the pool to a height great er
than the partly emptied shell
this caused buoy ancy force to uplift the shell
sand washed into the spaces and gaps which ultimately
caused the damage
hydrostati c valve worked but could not prevent damage
FSP’s report
11 - 11 - 2016
Engineer‟s report, HM, engineer
pool damaged due to hydrostatic forces following an entry of
water into the excavation
likelihood of fibreglass pool failing due to hydrostatic pressure
is significantly increased if the pool is not maintained full of
Case No: 475424 Recommendation Page 6 of 6
water
fibreglass pool manufacturers ro utinely advise against
emptying pools without bracing across pool, due to increased
risks of hydrostatic failures
pool installation has omitted the installation of a concrete ring
beam despite the shell containing metal fixing points that
were intended to connect it to a ring beam
such a beam was required by the pool‟s manufacturer
because there are now corroded steel wire ties that
connected integrally into the rim of the fibreglass pools shell
at the time of its fabrication
peripheral ring beams reduc e ri sk of water runoff being able
to flow directly into the gaps around pool, if installed, could
have reduced the risk of the type of failure that has damaged
the pool
aerial photos indicate that in summer months from 2010
onwards , the pool was empty or close to
aerial photos indicate pool has not contained well filtered
clear water or been maintained in a „swimmable‟ condition for
several years
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.