Home / Financial Firm (Unknown - Insurer) / Determination 471920

Determination 471920

Claim for foundation and subfloor damage declined under earth movement exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2017-10-31
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant claimed for home damage he attributed to a leaking sewer pipe, and the FSP declined under the earth movement exclusion. AFCA preferred expert evidence that the damage resulted from long-term drainage issues, so the FSP was entitled to deny the claim.

The FSP met the onus of proving the earth movement exclusion on the balance of probabilities, and the more detailed expert reports supported long-term drainage as the cause.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 471920 Determination Page 1 of 7 Case number: 471920 31 October 2017 1 Overview 1.1 Dispute The applicant lodged a claim with his insurer, the financial services provider (FSP), for damage to his home. The applicant says this was caused by a leaking sewer pipe. The FSP denied the claim on the basis the loss falls within a number of policy exclusions. This includes wear and tear, faulty workmanship and earth movement 1.2 Issues and key findings Can the FSP deny the claim? The FSP can deny the claim because the evidence shows the damage resulted from foundation movement due to long term drainage issues. This falls within a policy exclusion for earth movement. 1.3 Determination This determination is in favour of the FSP. The FSP is entitled to deny liability for the claim. Case No: 471920 Determination Page 2 of 7 2 Reasons for determination 2.1 Can the FSP deny the claim? FSP relying upon a policy exclusion The FSP has relied on numerous policy exclusions. This includes the following: You are not covered under any section of this policy for damage, loss or liability caused by, arising from or involving any of the following. … Earth movement, including settling, shrinkage or expansion.” The FSP has the onus of proving a policy exclusion applies. The standard of proof is the balance of probabilities. M and K’s evidence is preferred Numerous reports have been provided, including four from engineers. One of the engineers is a geotechnical engineer (HG) that was engaged by a second engineer (HCE). All of the relevant reports have been summarised in section 3.1 of this Determination. The engineers have provided conflicting opinions about the cause of damage. Two of the engineers (HG and HCE) were satisfied the damage was due to a leaking pipe. Two others (M & K) concluded the damage was consistent with long term drainage issues around the property. I have carefully reviewed all of the reports. I prefer the conclusions from M and K for the following reasons. First, their reports were more detailed and considered. Both identified and catalogued all of the damage within the home. This identified a number of factors inconsistent with damage from a leaking pipe at the rear of the property. For instance:  most of the hairline cracks were identified at the eastern and south-eastern parts of the home whereas the leak was towards the north-western part (M)  no significant cracks at all in the laundry or the adjoining toilet which are closest to the point of fracture (M)  minor cracking throughout the home consistent with a long term movement issue (P) HCE‟s report did not account for all this damage. HG‟s evidence was limited to their analysis of the bore samples taken and the evidence of moisture. Second, both M and K were consistent in identifying long term drainage issues causing minor distress. In particular, they both agreed the concrete paving along the northern side of the house would cause water ingress into the subfloor. M identified other factors. Neither of them were satisfied the sewer pipe could cause or contribute to the damage identified. Case No: 471920 Determination Page 3 of 7 In contrast, neither HCE nor HG accounted for other possible sources of ingress and explained why this would not have been the cause of damage. Therefore, their evidence was limited in comparison. FSP entitled to deny liability for the claim The applicant has said the house has not suffered such damage during his ownership. He says the drainage is sufficient and that it is unlikely water would enter the foundation. I do not accept this. There is no expert evidence supporting the applicant‟s contention. M and K‟ s inspection of the property identified areas of distress that were mainly minor. Their analysis and conclusions as to the cause are plausible given the areas of damage and their nature. Further, they are appropriately qualified to provide an expert opinion on issues such as drainage. In addition, I do not accept HG and HCE‟s reports are necessarily contradictory as they are less comprehensive and have simply not addressed all relevant points. As stated previously, it is unclear if they turned their mind to other possible causes of the water ingress or the extent of damage throughout the property. Accordingly, after careful consideration of all the evidence and arguments, I am satisfied the damage is consistent with foundation movement due to long term drainage issues surrounding the property. This falls within the policy exclusion of earth movement. Therefore, the FSP is entitled to deny liability for the applicant‟s claim. Case No: 471920 Determination Page 4 of 7 3 Supporting information 3.1 Expert reports Record Key points FSP’s assessor (CC) Report and SOW Undated  Insured reported a gas leak. A plumber attended to turn off the gas and observed a corroded copper gas pipe under the house.  Static water tests show no evidence of other leaks though testing of the stormwat er and sewerage lines were restricted.  Claim damage is corrosion of galvanised gas pipe caused by an escape of liquid, though no leaks found in any wat er lines.  Inspection of sub floor soils near driveway manhole did not indicate saturated soils.  Corrosion of the gas pipe would have occurred over many years due to moisture in the soils.  Brick paving is not falling away from the dwelling, drainage is not sufficient, rainwater likely entering the sub floor causing wet soils and erosion.  No evidence of stormwater or sewer leaks.  Hallway cracks not significant enough to suggest anything other than general movement.  Rust and corrosion in the garage is due to long term deterioration and exposure to the elements. No adequat e drainage around building.  Dete rioration and subsidenc e of the rear brick paving is wear and tear, likely due to poor site drainage.  Leaking gas pipe sits on the sub floor soil which makes it susceptible to corrosion. FSP’s plumber (IPI) Inspection Report 10.06. 16  No evidence of any leaks in hot and cold water system.  CCTV of stormwater drain (at front of property) identified mud and debris in drain, including tennis ball blocking the drain.  CCTV of sewer from overflow relief gully would not go around the trap – legal point of dischar ge is unknown.  Paving is uneven in the back yard and around the shed.  Shed‟s metal cladding is rusting at the base near the paving .  CCTV of sewer upstream showed no visible breaks or cracks. Full inspection of the sewer system not possible due to limited a ccess. Applicant’s plumber (HPS ) Quote 30 .0 6 . 16  Water pipes (green and blue in colour) are badly corroded and have minor fractures which are resulting in dampness. FSP’s geotechnical consultant (HG) Site Investigation Report 19.09. 16  Site classified as „ Class P‟ due to abnormal moisture conditions and proximity of trees.  Soil classification: H2 (slightly reactive clay soil).  More moisture observed towards rear of the site.  Up to a 9% moisture variance observed across the site at a depth of 500mm, indicati ng a leaking service at the rear right hand side of Case No: 471920 Determination Page 5 of 7 the house.  Clay soils at the rear of the house have heaved. FSP’s engineer (HCE) Report 04.10. 16  Hous e restumped eight years previously when rear extension constructed.  Cracking and movement occurring at northern side of residence, allegedly due to water escaping from leaking sewer pipe located below timber decking at north - west corner of residence.  Plumbing investigation of sewer pipes were not able to be carried out by IPI.  Excessive dampness present be low the centre of the residence and towards the rear extension – an inspection of the subfloor space on the nort hern side was unable to be carried out .  HG‟s analysis show high moisture readings at the borehole where the sewer leak is occurring and also bel ow the kitchen floor.  It is our opinion the damp foundation material resulted from the escape of water from the cracked sewer pipe.  “It is our opinion that the cracking and movement that has occurred … is a result of differential movement of the stumps due to the escape of water from the cracked sewer pipe saturating the foundation material. ” Applicant’s plumber (PWS) Report 05.10. 16  Attended the property to investigat e a blocked toilet.  Machine used to inspect disconnector gully on blind side of the house ; machine could not get past 30 feet downstream from this point and ret urned covered in clay – suggests the drain had collapsed.  Camera survey then confirmed drain collapsed or has not been connected to the new sewer lines .  Basin left running in the proper ty, with no signs of water entering the existing drain line. This suggests the original line was never reconnected.  Excavation confirmed the drain was never reconnected; soil very damp around this location.  Existing drain never reconnected to the new section of drain installed at the time of the extension – all water from basin draining directly into the soil beneath the extension. FSP’s technical consultant (M) Report 24.10. 16  Property suffered a fractured sewerage pipe, said to have caused damage to the property.  Location of the fracture was reported to be under rear deck outside of the laundry and near the outside tub, at the northwest corner of the building.  Most internal cracking and alignment issues ide ntified at the eastern and south - eastern parts of the building, though there are some issues in the vicinity of the fractured sewer pipe.  This is an anomaly as most movement should occur in the vicinity of the fractured sewer pipe.  Flaking weather boards n ot related to moisture under the house.  Only minor movement of rear porch (proximat e to leaking sewer pipe) observed.  Four significant external construction issues were identified which Case No: 471920 Determination Page 6 of 7 would contribute directly to the increase of moisture under the house every time it rains:  1. Perimeter of house fitted with concrete apron, trapping water beneath the property when it rains. Liquid trapped has no way of escaping. This is a likely cause of the sewer pipe fracturing.  2. The path surrounding the house sits hi gher than the subfloor void, causing water to accumulate with no way of escaping.  3. Rear garden path slopes away but not sufficiently to drain water away from the house. The single stormwater drain inlet is located at the highest point in the yard and so does not actually capture any stormwater.  4. Flower beds installed at the eastern face of the property are directly against the house, preventing any natural flow of water through this space, whic h is critical given other observed drainage issues.  Any one of these issues would have been sufficient to cause the hairlines cracks in the house.  The corroded gas pipes should have been suspended above the ground.  Construction of the deck was the most likely cause of the sewer pipe breaking.  “I am therefore unable to attribute any of the damage to any leaking sewer drain pipe.”  “I consider the non - compliant construction to have been the cause of wetted soils which in turn damaged the sewer pipe and led to the corroding of the gas pipe which drew attention to the moist conditions.”  Non - compliant and ineffective storm water management led to increased ground moisture under the dwelling. FSP’s engineer (M ) Report 30 . 1 2. 1 6  The defective workmanship was unlikely to have had much effect on the structure of the house  At most, it would have led to the cupping of the floor planks at the end of the extension  However, there are several additional factors whic h, in and of themselves, would have been sufficient to cause the moisture related damage to the floor planks.  The only possible impact of a disconnected drain pipe might have been contributory, minimal if anything at all. FSP’s engineer (K) Report 08.02. 17  Property falls from the rear boundary to the street – floor level 150mm above paving at the rear compared to 400mm n ear the front house entrance door.  Minor cracking was observed throughout whole residence, in walls and at cornice level, as well as out of square door arc hitraves and cupboard doors indicating a long term movement issue.  Negative fall exists in the brick pavers and possibly pooling of water next to northwest corner of rear timber deck.  Side concret e path discharges at gate onto the brick paving and ground at subfloor space.  In our experience, when sewer lines are cracked or leak at pipe joins, the escaping waters are not in great volume and water tracks Case No: 471920 Determination Page 7 of 7 in the excavation along the pipe run – this is away from the house.  In our opinion, as the external brick paving is undrained (formally) and open jointed, the variation in soil moisture content change is a m uch more influencing effect than a leaking sewer line that drains away from the property.  The amount of water escaping from a cracked sewer pipe would not cause the movement and cracking observed throughout the entirety of the house.  The distress is minor and is the influence of seasonal moisture changes in the highly reactive soils.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.