Home / Financial Firm (Unknown - Insurer) / Determination 470561

Determination 470561

claim_denial

FirmFinancial Firm (Unknown - Insurer)
Decided2017-12-28
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicants' claim for cracking damage to their investment property was denied because the evidence did not show an insured event. AFCA found the insurer had no right to cancel the policy and ordered the cancellation removed from their insurance history.

The insurer's denial stands because proximate cause was not shown to be an insured event, but the cancellation under section 60 was not supported by evidence and is void under section 63.

Issues

Subjects and remedies

correct records

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 470561 Determination Page 1 of 8 Case number: 470561 28 December 2017 1 Overview 1.1 Dispute The financial services provider (FSP) denied the applicants‟ claim for damage to their investment property on the basis it was not caused by an insured event. The applicants dispute this as they say the damage was caused by a leaking pipe. This is an insured event. The applicants also dispute the FSP‟s decision to cancel their policy. 1.2 Issues and key findings Can the FSP deny the claim? The FSP can deny the claim because the evidence does not show the damage was caused by an insured event. Was the FSP entitled to cancel the applicants’ policy? The FSP was not entitled to cancel the policy. This is because the evidence does not show the FSP had a right to do so. 1.3 Determination This determination is substantially in favour of the FSP. The FSP is entitled to deny liability for the applicants‟ claim. The FSP was not entitled to cancel the applicants‟ policy. This should therefore be removed f rom the applicants‟ insurance history. Case No: 470561 Determination Page 2 of 8 2 Reasons for determination 2.1 Can the FSP deny the claim? Applicants must establish a prima facie claim The applicants are required to show that, on the balance of probabilities, they suffered a loss caused by an event insured for under the policy (insured event). This is known as a prima facie claim. The applicants‟ policy covers them for loss or damage to their home if it is caused by a number of insured events. This includes damage from a leaking pipe. It is generally accepted the term “caused by” within an insurance policy means proximate cause. Proximate cause is the dominant, efficient or operative ca use of the loss. Therefore, in order for the applicants to establish a prima facie claim, the evidence must show the proximate cause of damage was an insured event. Parties are relying on engineers’ opinions The damage being claimed includes fairly extensive cracking to the property. The applicants say the damage is either due to vibration from construction works or a leaking sewer system. The applicants are relying upon an engineer‟s opinion (ICE) in support of their position. ICE concludes the damage is mainly caused by plumbing faults and the effects of trees. ICE does not attribute any of the damage to vibration. The FSP has provided a number of reports from engineer RDE. RDE was not satisfied the damage is consistent with a leak. Instead, RDE believes the damage is long term. Given RDE‟s evidence, the FSP says the damage was not caused by an insured event. These reports, as well as other relevant opinions and correspondence, are summarised in section 3.1 of this Determination. Evidence does not show damage caused by an insured event Damage caused by vibration is not covered by the policy. Neither does any expert support the applicants‟ submission that this was a cause of damage. Therefore, this argument is not accepted. Regarding the applicants‟ submi ssion that the damage was caused by leaking pipes, I am not persuaded by this for the following reasons. First, ICE‟s opinion was clearly based on an assumption that the major distress in the building only occurred in the last nine months. Case No: 470561 Determination Page 3 of 8 The FSP has provided substantive evidence refuting this assumption. RDE in particular highlighted a number of active cracks that the applicants previously claimed for with the FSP in 2015. The FSP provided photographs and information of the two claims lodged in 2015 to s upport RDE‟s conclusions. This contradicts ICE‟s assumption that the distress is recent. RDE also identified numerous cracks that had been previously repaired. This supported RDE‟s conclusion that the cracking to the property has been ongoing for longer than the nine months assumed by ICE. It is not apparent that ICE was aware of this history. Given this, I do not accept ICE‟s conclusion is persuasive as it was based on an assumption that is not substantiated on the available evidence. Second, the evidence does not show there is a leak which could cause the soil moisture to increase to such an extent that it would result in the damage being claimed. Plumbing investigations show there were multiple breaks located in the sewer system near the southern wall. However, RDE was not satisfied this would have been sufficient enough to cause the distress to the southern wall. ICE‟s language regarding this substantive point is equivocal. For instance ICE says: “The plumbing faults may have caused the soil moisture c ontent to increase locally … … indicate that the issue may have been occurring for a long period of time and a substantial amount of moisture could potentially have leaked …” (my emphasis) This shows ICE was only prepared to say it is possible these leaks could have caused the damage. Not that they did. Therefore, none of the available experts are prepared to conclude the damage was caused by a leaking pipe. FSP is entitled to deny liability Given all this, I am not persuaded the evidence shows the proximate cause of damage to the property was a leaking pipe. Neither does the evidence show the damage was caused by another insured event. Accordingly, the FSP is entitled to deny liability for the applicants‟ claim. 2.2 Was the FSP entitled to cancel the applican ts’ policy? Evidence does not show FSP had a right to cancel the policy Section 60 of the Insurance Contracts Act (the Act) provides an insurer with the right to cancel a contract of general insurance in certain circumstances. The FSP sent a letter dated 25 August 2016 cancelling the policy. The reason provided was because the property no longer met the following condition: Case No: 470561 Determination Page 4 of 8 “We may refuse a claim, cancel your Policy or do both, if you do not maintain your home in good repair and condition. This means your home must be watertight, structurally sound, secure and well maintained.” This appears to relate to section 60(2)(b) of the Act which says: “Where … the effect of the contract is to authorize the insurer to refuse to pay a claim, either in whole or in part, by reason of an act or omission of the insured or of some other person … and, after the contract was entered into, such an act or omission has occurred, the insurer may cancel the contract.” The evidence did not show the FSP was entitled to deny the claim based on this provision. Further, the FSP‟s builder (JBPF) said the home was “maintained as could be expected”. This refutes the FSP‟s assertion that the property was not maintained. Given this, I do not accept the evidence shows this provision was engaged. The FSP also referred to the applicants failing to inform it of the state of the property before the policy renewed. Such a submission appears to refer to a failure to comply with the duty of disclosure or making a misrepresentation. The FSP has not provided submissions or evidence to establish these grounds. Therefore, I am not persuaded they are applicable. Given all this, I do not accept the FSP has shown it had a right to cancel the policy. As such, any cancellation of the policy is void pursuant to section 63 of the Act and should be removed from the applicants‟ insurance record. Case No: 470561 Determination Page 5 of 8 3 Supporting information 3.1 Expert reports Expert Key points FSP’s builder (JPFB ) Report 19 - 05 - 2016  There are signs of general building movement throughout the property.  The property is maintained as could be expected – as a general comment, much of the home could be considered as at the end of its service life.  Significant movement is evident specifically to the area in the vicinity of the internal staircase, including di stortion of the external double brick two storey wall – this appears to be close to becoming dangerously disengaged from the floor structure which might normally be considered as a structural/ bracing element.  The stormwater system is above ground and funct ioning as designed.  The insured and the neighbour have both recorded an action against the sewerage authority, as there had been a blocked pit nearby which caused damage to the road and an isolated overflow in the vicinity of the reported damage.  The neig hbour‟s description of an above ground overflow is not consistent with an event that may contribut e to the type of damage noted in this claim.  There is minor cracking to the sewer lines (terracotta pipework) – this defect is underneath part of the building not obviously affected, or being claimed – suspect these are unrelated to the damage sighted.  This area is built on a dark clay with high elasticity and building movement is not uncommon.  Did not identify any damage directly attributable to an insurable incident existing within the property. FSP’s plumber (PBP) CCTV Investigation Report 19 - 05 - 2016  Pressure testing held for approximately 15 minutes – this indicates no current leakage concerns.  During our CCTV inspections we found majority of the drainage system was in a good condition, although 2 minor fractures were sighted.  Information gathered found major blockages affecting the neighbouring property in the direct area of downpipe at laundry. Major amounts of overflowing sewerage were sighted. FSP’s e ngineer (RDE) Report 01 - 07 - 2016  The dwelling foundations are subsiding on the south eastern end  There are many active cracks throughout the internal walls of the dwelling, particularly around the south west wall.  The cause of foundation movement is current ly unclear.  Recommend a thorough inspection be conducted in the neighbouring easement for leaking pipes.  In its current condition the dwelling may be structurally unsafe for the occupants. If the south eastern wall continues to move it will Case No: 470561 Determination Page 6 of 8 inevit ably caus e the collapse of the dwelling.  Overall the dwelling is in poor condition and is showing significant signs of aging, however this is to be expected of a building of this age. The dwelling is considered to be at the end of its service life.  The dwelling is showing significant signs of foundation movement – particularly around the south easternmost wall – this wall is leaning away from the remaining part of the dwelling.  Multiple cracks were evident and a number have been aesthetically repaired.  The easement directly adjacent to the south eastern wall was saturated – a slow leak was seen on the overflow of the hot water unit attached to the neighbour‟s outhouse – this leak is unlikely to have affected the foundation  The construction site located at number 1, a pproximat ely 50m away, was also suspected to be contributed to the cracking. However the construction site is located outside the normal influence radius that would be expected from such mid - size construction. Ty pically the immediately adjacent buildings w ould show signs of influence first and construction methods would be updated to limit these effects stopping the damage to properties located further away.  The sewage leak described by JPFB that came from the overflow relief grate on the neighbouring prope rty may have contributed to the overall soil adjacent to the south eastern wall. However the quantity of water discharged is unlikely to be the major cause of the foundation movement. This discharge would have had a minimal effect. From the saturation of t he soil it is more likely that a slow leak of the constant wet weather conditions have affected the foundations. FSP’s plumber (IP) Report of neighbouring property 17 - 06 - 2016  Conducted a meter reading and static pressure test of the hot and cold water pipe and there was no evidence of a leak in the water pipes at this time.  The downpipe on the laundry outside the building is not connected to the stormwat er drain  There is a crack in the earthenware clay stormwater drain  A full inspection of the sewer dra in was not possible at this time due to breaks and cracks in the trap of the overflow Gully outside the bathroom and a blockage in the drain at the laundry and toilet outbuilding. The exact location of the boundary trap was not found at this inspection.  A full inspection of the stormwater drain was not possible at this time due to poor access and blockages in the drain. The exact condition of the sewer and stormwater is unknown.  A water jet drain clean is required of the sewer and stormwat er drainage and re moval of the concrete around the base of the downpipes so a full inspection of the drain can be achieved. FSP’s engineer (RDE) Letter 1 1 - 07 - 2016  Separation of the first floor from the south east wall is more likely a result of ground movement.  The crackin g is not only isolated to the south eastern side. The building as a whole, including the neighbouring property at number Case No: 470561 Determination Page 7 of 8 4, has subsided on both sides.  The neighbouring property was inspected and showed signs of significant ground movement in not only the direction of the easement – it included the south western front ent ranc e and exterior walls in multiple locations.  Inspection of the cracks that had been patched showed they were active.  The information suggests there is a past history of foundation moveme nt in the structure. App’s engineer (ICE ) Report 09 - 12 - 2016  A geotechnic al investigation conducted in the near vicinity shows highly reactive soils.  Floor level survey revealed a differential of about 103mm across the dwelling.  It is our opinion that the most likely cause of distress to the residence can be attribut ed to Differential Movement due to abnormal moisture conditions.  Primary Contributing Factors - The plumbing faults in the neighbouring property along the edge of the Southern wall may have cause d the soil moisture content to increase locally, causing the soil to swell and lift the building in return. The severity of the plumbing breaks reported to the local water aut hority indicate that the issue may have been occurring for a long period of time and a substantial amount of moisture could potentially have leaked into the soil in the area. - The large trees at the front of the property will have a drying effect on the soil across the front of the dwelling due to no tree root barrier being installed to prevent tree roots penetrating under the dwelling. This in combination with the plumbing faults appears to have caus ed differential movement across the dwelling as the trees dry out and „shrink‟ the soil across the front of the dwelling and the plumbing f aults along the Southern edge of the dwelling causing the soil moisture content to increase and the soil to „swell‟. - As the dwelling is approximately 100+ years old and the major distress to the building has only occurred in the past 9 months, this indicat es that an external sourc e has caused the distress to the dwelling and it is not the result of natural variations in soil moisture content around the property and the neighbouring property.  The damage witnessed during our investigation does not pose any ri sk to the structural integrity of the building. App’s engineer (ICE ) Email 23 - 08 - 2017  The date of distress is an approximate based on the information gathered and discussions with the tenants and ins ured at that time. FSP’s engineer (RDE) Email 29 - 08 - 201 7  The quantity and duration of the sewage discharge was not enough to cause the damage.  Moisture was noted along the sout h eastern wall, however the exact source was not identified. Wet weather conditions (seasonal Case No: 470561 Determination Page 8 of 8 moisture) was presented as a cause of the damage. Anot her potential cause of the damage is the dwelling does not have any effective civil drainage to stop water ponding next to the south eastern footings. This can result in foundation movement.  The damages present are unlikely to have occurred ov er such a short period as nine months. The photos are evidence the dwelling had a previous history of movement and cracking. Some of the cracking had been attempted to be repaired. Thes e repairs appeared to have significant age, assumed to be older than ni ne months. Significant cracking like this would slowly became evident over a period of 3 - 5 years if exacerbated by an external force such as a slow leak. This type of damage could also be caused by seasonal foundation movement over the life of the structur e.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.