Home / Financial Firm (Unknown - Insurer) / Determination 467232
Determination 467232
Retaining wall collapse claim declined
Summary
The applicants' front retaining wall collapsed and the FSP refused the claim under structural fault and wear and tear exclusions. AFCA found the collapse was accidental and ordered the FSP to pay the $56,702.27 repair cost plus interest.
The FSP did not establish that the applicants knew or ought to have known of a structural fault, or that gradual deterioration was the proximate cause of the collapse.
Issues
- Claim denial primary · upheld“I am satisfied the applicants have established a valid claim ... the FSP has not established the application of a policy exclusion”
- Inadequate claim investigation secondary · unclear“The FSP's engineer FM did not examine the wall but instead relied upon photographs provided”
Subjects and remedies
home or building damagepay claimpay interest
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
Case No: 467232 Determination Page 1 of 11
Case number: 467232 9 February 2018
1 Overview
1.1 Dispute
The applicants lodged a claim on their Classic Home Policy held with the financial
services provider (FSP), after the retaining wall at the front of their property collapsed
on or about 1 September 2016. The FSP declined the claim on the grounds that:
the applicants have not established that the damage was caused by an
accident within the meaning of the policy
the damage was directly or indirectly caused by or arising out of a structural
fault, faulty design or faulty workmanship of which the applicants were aware or
ought to have been aware or
the damage was caused by wear, tear, rust, corrosion or gradual deterioration.
The applicants dis pute the FSP‟s position and maintain the damage was accidental
damage covered under the terms of the policy.
1.2 Issues and key findings
Have the applicants established a valid claim under the terms of the policy?
I am satisfied the applicants have established a valid claim within the terms of the
policy. The collapse of the retaining wall was sudden, unexpected and an unintended
event which neither the applicants nor a reasonable person in their position would
have expected.
Has the FSP established the application of a policy exclusion?
The FSP has not established that an exclusion applies to defeat the claim because:
the available information does not establish that the damage arose directly or
indirectly out of a structural fault, faulty design or faulty workmanship that the
applicants knew or ought to have known
the available evidence does not establish that the damage was caused as a
result of wear, tear, rust, corrosion or gradual deterioration.
1.3 Determination
This determination is in favour of the applicants.
As the applicants have completed the repairs to the retaining wall at a cost of
$56,702.27 the FSP is to cash settle the claim for $56,702.27 plus interest under
section 57 of the Insurance Contracts Act 1984 (the Act) from 24 April 2017 to date of
payment of the claim.
Case No: 467232 Determination Page 2 of 11
2 Reasons for determination
There has been a full exchange of material between the parties and each party has
had the opportunity of addressing the issues that arise from the information
exchanged.
Following rejection of the recommendation, the applicants supplied additional
material including statutory declarations from the Project Manager for the repair of
the retaining wall and from their gardener of the last five years.
The applicants also provided further details of her water use d uring the relevant time.
Most recently the applicants provided a copy of the invoices and receipts relating to
the repairs to the retaining wall that they have paid.
The additional information has been supplied to the FSP. The FSP has not
addressed the comments made in the statutory declarations but relies upon its
previous submissions in relation to the claim.
This determination follows consideration of all of the information exchanged. It is
based on what is fair in all the circumstances, having regard to the relevant legal
principles, terms of the policy, good industry practice including codes of practice and
prior determinations where applicable.
2.1 Have the applicants established a valid claim under the terms of the
policy?
Policy provides cover for accidental damage
The applicants‟ policy a Classic Home Policy provides cover for accidental damage.
Accidental damage is defined under the terms of the policy to be:
„sudden, unexpected and unintended event which:
you did not intend or expect: and
a reasonable person in Your position and with Your knowledge and experience
would not have expected.‟
The FSP maintains that the applicants have not established that the event was an
accident as defined under the policy. The FSP maintains that a reasonable person in
th e applicants‟ position would have been aware that the wall had structural issues as
the rotation was clearly visible.
I do not accept the FSP‟s position. Whilst I accept a photograph provided from a
Google map indicates some slight movement in one corner of the wall, there is no
other information provided to suggest that the applicants would have been aware that
the retaining wall was in danger of collapsing.
To the contrary, photographs provided from November 2014 suggests that the wall
was in a relatively sound and stable condition. I acknowledge that the photographs
are not detailed but there is nothing within the photographs to suggest that the
applicants would expect the wall to collapse.
The applicants have provided a statutory declaration from their gardener GG. GG
had been familiar with the applicants for 15 years and had worked as their gardener
Case No: 467232 Determination Page 3 of 11
for the last five years. GG denies that the wall was in a state of disrepair and denied
that there was any fear of the wall collapsing. The FSP has offered no response to
this statutory declaration.
The FSP‟s builder „J‟ noted the applicants had said they had noticed the wall
developed a lean but they did not thought it to be a problem.
The FSP‟s engineer FM did not examine the wall but instead relied upon
photographs provided. His report was based on historical Google street views and
contractor photos taken before the wall had been removed. FM refers only to rain
before June 2016.
The applicants‟ information is that the garden had undergone extensive waterin g
after new turf had been laid in March 2016 and that there had been heavy rainfall
throughout the winter of 2016 up to 1 September 2016. I accept that this is the case.
In the circumstances, I am satisfied that the applicants and a reasonable person in
th e applicants‟ position with the applicants‟ knowledge and experience would not
have expected the collapse of the retaining wall. I am satisfied that the applicants
have established a valid claim under the terms of the policy.
The onus is therefore on the FSP to prove the application of one of the exclusions
relied upon if it is to deny liability for the claim.
2.2 Has the FSP established the application of a policy exclusion?
The FSP relies essentially on two exclusions to deny liability for the claim
The FSP says the damage arose directly or indirectly out of a structural fault, faulty
design or faulty workmanship that the applicants knew of or ought to have known.
The FSP says the applicants failed to fix or arrange to have fixed , the retaining wall
prior to it collapsing in 2016.
Alternatively, the FSP maintains that the proximate cause of the damage that is the
dominant or effective cause of the damage, to the wall was wear, tear, rust, corrosion
or gradual deterioration. The FSP relies upon reports provided by its builder J, and
engineer FM to establish the application of the relevant exclusions.
Information does not establish the applicants knew or ought to have known of
any structural fault, faulty design or faulty workmanship
The initial report from J confirms:
retaining wall was built approximately 50 years ago
the applicants had noted the wall had developed a lean which had worsened
recently
an increase in the amount of vegetation would have increased the pressure on
the brick/retaining wall over time
the existing footings are unlikely to be adequate for the new brick/retaining wall
it appears the existing brick/retaining wall has reached the end of its service life.
It is unclear how J formed this view.
Case No: 467232 Determination Page 4 of 11
The applicants deny that they said they had noticed the wall had developed a lean.
According to the applicants whilst they were aware of some movement in one corner
of the wall, the wall otherwise appeared sound. The applicants admit noticing shortly
prior to the collapse of the wall that it appeared to have developed a lean. That was
very close to the time that the wall had actually collapsed.
The applicants deny that there had been any increase in vegetation in the area.
Looking at the photographs provided, it appears that the vegetation that was behind
the retaining wall is largely shrubs and whilst these may have grown over the years, it
does not appear to be a heavy vegetation area.
The report from the FM is dated 19 December 2016. It is based not on an inspection
of the applicants‟ property or the wa ll but based on images provided from Google and
photos obtained from the contractors prior to the wall being removed.
The FSP has not referred the statutory declarations provided by the applicants to the
engineer for further comment.
FM considered however that photographs of the property reveal:
tree roots were at the length of the retaining wall
the inner skin of the wall at the western end of the retaining wall
The applicants dispute that there were tree roots the length of the retaining wall.
I accept that there are some roots identified in the photographs. It is unclear whether
these are tree roots or plant roots. I cannot identify that these roots were throughout
the length of the retaining wall.
FM refers to evidence of notable outward rotation of the retaining wall relative to the
neighbouring brick pier wall at the western end of the wall. The Google photographs
reveal some minor rotation at that end of the wall.
FM concluded that the damage to the brick wall was not recent and it is evident the
movement and damage to the wall had been occurring gradually for many years prior
to the eventual failure. FM also commented that it is likely the absence of proper
drainage behind the wall would have allowed development of additional pore water
pressure. There is no evidence that the wall was not properly drained. The wall had
been standing for almost 50 years. Photographs from 2014 do not show any
significant deterioration.
FM made reference to large trees and shrubs. The applicants have pointed out these
trees were conifers which are shallow rooted.
FM, without making reference to the relevant design standards in 50 years ago has
commented that the brick retaining wall and that the failure or collapse of the
retaining wall was due to its adequate design and/or construction resulting on long
terms outward rotation/movement of the wall leading to its eventual collapse. As I
have noted the wall had stood for 50 years with no sign of significant deterioration. I
do not accept that there is evidence of inadequate design or construction.
Whilst the FSP has provided supplementary reports from engineer FM, I am not
persuaded that these reports establish that there was structural faults, faulty design
or faulty workmanship of which the applicants knew or would have known. FM has
Case No: 467232 Determination Page 5 of 11
not addressed the fact that the wall had stood for 50 years. As at November 2014,
only minor movement was to one edge of the wall which I note did not collapse when
the rest of the wall collapsed.
I note from some Google photographs provided from November 2014 that the wall
appeared to be in relatively good condition. I also note from the statutory declaration
provided by GG who attended the applicants‟ garden for five years that she had
never seen the retaining wall in any state of disrepair or in fear of collapse.
JM, the project manager for the construction of the new retaining wall confirms that
he removed the debris on 2 September 2016. He maintains that he removed
vegetation which had not contributed to the failure of the wall as it was still intact with
no roots exposed. The large trees referred to by F M were conifer trees which JM
notes were 1.5m back from the wall and shallow rooted.
According to JM, the ground was all hard rock clay which root systems of any shrubs
or trees could not penetrate. He did not consider the roots could have caused the
retaining wall to collapse.
The FSP has not referred the statutory declarations provided by the applicants to the
engineer for further comment.
Even if the retaining wall may have been built in a manner which could not resist the
retaining pressure, I am not satisfied that there is any evidence to establish that the
applicants knew or ought to have known about such fa ult.
In the circumstances, I am not satisfied the FSP has established the application of
the exclusion relating to structural fault, faulty design or faulty workmanship.
The FSP has not established the damage is due to wear, tear, rust, corrosion or
gradual deterioration.
The FSP says that although a storm or rainwater runoff may have been the final
event to affect the wall, the wall had been deteriorating for a long length of time which
is consistent with gradual deterioration.
In a further response on 10 March 2017, the FSP notes that engineer FM would not
expect any affects resulting from excessive watering of the front lawn up to 11 April
2016 to have contributed to the collapse of the wall. The FSP says there was clearly
a fault with the wall, the applicants had failed to take any action to repair that and the
wall had continued to deteriorate over a prolonged length of time.
The applicants‟ advice is that the y continued to water the lawn although not as
heavily after April 2016. This is supported by the history of their water bills. They also
note that in the following months there was also heavy rainfall. FM does not believe
the rainfall would have contributed to the collapse.
The opinion of the FSP and its engineer FM appears to relate largely to the Google
photograph from August 2014 showing a slight rotation of the western end of the
retaining wall. Photographs taken in November 2014 reveal a reasonably stable wall
and do not suggest that the wall was at that time suffering any significant wear and
tear or deterioration.
Case No: 467232 Determination Page 6 of 11
Again, the independent evidence from the applicants‟ gardener GG is that she had
not observed any deterioration in the wall nor was she concerned that it might
collapse.
I accept that the wall did collapse because of the increased pressure. The increased
pressure was a result of the changes the applicants had made to the garden. Whilst I
accept that there may have been a structural fault in the design, I do not believe this
was the proximate cause of the collapse nor do I belie ve the FSP has established
that the gradual deterioration of the wall is the proximate cause of the collapse.
The structural characteristics and gradual deterioration may have contributed to the
collapse of the wall. However, in my view, based on the available information, the
FSP has not established that the proximate cause , that is, the dominant or effective
cause leading to the collapse of the wall on 1 September 2016 was either a structural
fault, faulty design or faulty workmanship or wear, tear or gradual deterioration.
In my view, it is more likely that the proximate cause was the work that had been
performed leading to increased pressure on the wall. I am satisfied in the
circumstances that such damage is accidental damage within the terms of the policy
and the FSP is liable to meet the applicants‟ claim.
Settlement of the claim
The applicants have advised that the wall was repaired at a cost of $56,702.27. The
applicants have provided receipts to support this.
Two quotations were provided by the applicants. The first for $44,614.80, the second
for $55,891.40. I acknowledge from the information exchanged that it is likely that the
excavation of the wall in order to replace the retaining wall took longer than what was
anticipated and therefore this would have led to an increase in costs.
It is fair in the circumstances that the FSP pay the applicants the cost incurred of
$56,702.27. The repairs were completed in late March 2017. It is fair in the
circumstances that the FSP pay interest under section 57 of the Act from 24 April
2017 being approximately one month after the completion of the repairs, to date of
payment of the claim.
Case No: 467232 Determination Page 7 of 11
3 Supporting information
3.1 Policy provisions
Certificate of insurance
Location: [applicant‟s home address]
Ri sk 001/001 Classic Home Effective 16/03016
…
Policy wording
General definitions applying to words we use in this Plan
WORDS OR TERM DEFINITION
Accident means a sudden, unexpected and unintended event which:
You did not intend or expect; and
a reasonable person in Your position and with Your knowledge and experience would
not have expected.
„Accidental‟ and „Accidentally‟ have corresponding meanings.
…
Storm means violent wind or thunderstorm (including a tornado or cyclone), hail, rain or snow.
…
Classic home policy
…
What You are insured against
This policy insures You against Accidental damage, burglary and theft occurring during the
Period of Insurance.
…
What is not insured
This policy does not insure You against:
…
2 damage directly or indirectly caused by or arising out of:
…
mildew or mould or wet or dry rot.
a structural fault, faulty design or faulty workmanship if You knew or ought to have
known about the structural fault, faulty design or faulty workmanship and failed to fix it
or arrange to have it fixed before the damage occurred or commenced to occur
…
11 wear, tear, rust, corrosion or gradual deterioration.
Case No: 467232 Determination Page 8 of 11
3.2 Reports considered
Record Key points
FSP’s builder (J)
Site report
Inspection
9 September 2016
Applicant unable to identify defined/single event.
Applicant confirmed they had noted the fence /retaining wall has developed
a lean, however, they had not thought it to be a problem or were conc erned
by it. Recently, they noticed it had worsened.
Applicant confirmed fence was built approximately 50 years ago.
On inspection, J noticed a large amount of soil and vegetation is retained
by brick retaining wall. Increase in amount of vegetation would have
increased pressure on wall over time.
J also not ed a large amount of rock behind wall. We also note existing
footings are unlikely to be adequat e for the new brick/ retaining wall
structure.
It would appear that the existing brick retaining wall has reached the end of
its service life and most likely cause of wall is general wear and tear.
(Photos attach ed)
FSP’s expert ( F )
Report
19 December 2016
Applicant advised that hous e and retaining was were constructed
approximately 51 years ago. Applicant is of view that wall has been
properly maintained throughout its life.
Applicant‟s brick retaining wall was entirely removed and d isposed of prior
to F ‟s inspection
N eighbouring brick pier located directly adjacent to the western end of the
removed wall is relatively plumb/upright.
Photos provided by FSP‟s contractor show tree roots throughout the length
of re taining wall, and retaining wall‟s inner skin at western end.
Google Street View shows height of wall is approximately 1m, as is the
height of retained material; also shows notable outward rotation of retaining
wall relative to neighbouring brick pier at w estern end of wall
Applicant engaged builder to remove and dispose of collapsed brick wall –
strata rocks behind the wall were very hard – took builder 3 weeks to
excavate the rocks and remove wall.
Applicant engaged R (structural and civil engineers ) to design reinforced
concrete retaining wall to replace collapsed brick wall.
In opinion of F, damage to retaining wall is not recent and it is evident that
movement and damage to wall has been occurring for many years prior to
its eventual collapse.
Outward leaning of wall is typical of damage caus ed by long term earth
retaining and/or hydrostatic pressures behind wall.
Likely that absence of proper drainage behind the wall would have allowed
development of additional pore water pressure to build up, increasi ng
lateral load on already under - designed wall.
Relatively large trees and shrubs observed along sout hern side of wall,
within retain soil. In opinion of F, physical root growth of trees and shrubs is
also exerting mechanical lateral pressure behind wall.
In summary, it is F‟s opinion observed damage to brick retaining wall along
northern boundary has not been caused by any particular event.
F is also of the opinion that failure/collapse of brick retaining wall is due to
inadequate design and/or constructio n, res ulting in long term outward
rotation/movement of wall leading to its eventual collapse.
Case No: 467232 Determination Page 9 of 11
Commonly adopted design life of such retaining wall structures is 25 - 50
years.
(Photos attached)
Applicant “Google ”Photos of wall = August & November 2014
Bur eau of Meteorology – rainfall statistics a “V” rain station – showing
rainfall for Winter 2016 was 190.6mm, compared to winter average of
161.5mm.
Diagram showing rotation required for wall to collapse
Water usage account showing:
o Total usage for 11/4 – 8/7/2016 (88 days) = 44kL
o Average daily usage for current (July) period – 44kL/88days = 500L
o Average daily usage for previous (April) period – approx. 800L
FSP’s engineer (F)
Report
3 February 2017
Response to comments from applicant with respect to F‟s 19 Dec 2016
report.
Rainfall summary provided by applicant shows total accumulated rainfall
during entire winter season (3 mont h from June – August) at “V” station.
o Average monthly rainfall for month of June was 71.8mm, June was
highest recorded during th is period and relevant to reported failure of
wall
o Recorded rainfall is less than long - term average recorded at V station
for equivalent 1 month or 3 month periods – several considerably
higher rainfall seasons (including 2013 wint er season, during which
2 28mm of rain was recorded at V station, but no resultant wall
collapse). This indicates rainfall was not the proximat e cause of
collapse of wall.
F again notes that Google Street View image from August 2014, showing
the subject wall, provides evidence that outward rotation/movement of wall
has been occurring over an on - going, long term period – as a result of
other factors unrelated to rainfall.
o F confirms that it does not suggest that wall failed at the time the
Google Street View image was taken. Conditi on and magnitude of
outward rotation/movement of wall immediately prior to its collapse (1
September 2016) is unknown.
If subject wall had an adequate and functional drainage system, as claimed
by applicant, then rainfall of winter 2016 season would not be expected to
have affected or contributed to collapse.
Re: applicant‟s statement that there are no large trees on southern side of
wall (2 medium sized conifers – known to have shallow roots - 2m back
from wall, and small shrubs 1m back from wall; neither of which would
have exerted mechanical lat eral pressure behind wall)
o Referenc e on 19 Dec 2016 report to medium and large trees is a
subjective opinion. The 2 x 2m trees on southern side of wall are more
than twice the height of the wall structure and are less than 1m away.
F considers these trees are located well within theoretical “zone of
influence” to wall.
o Relevant Australian Standard advises tree roots systems can
adversely affect footings/structures if they are within 0.75x their mat ure
height.
Re: a pplicant‟s comments that tree roots (appearing in photographs
attached to J‟s 9 Sept 2016 report) only appear in small section of wall, and
Case No: 467232 Determination Page 10 of 11
are fragile, broke off easily and could not have exerted any pressure on
wall – and that there are no tree roots sho wing through the lengt h of wall.
o F refers to photo attached to this (3 Feb) report, showing roots
throughout length of collapsed section of wall.
o F believes there must have been tree roots behind western section of
wall where the inner layer of wall stayed intact (due to the presence of
numerous trees and shrubs).
o F is of opinion that tree roots is not the only contributing factor in wall
collapse. F believes the most significant factor is inadequate
design/construction of wall structure.
Applicant’s
neig hbour (NM)
Statement
12 February 2017
For a number of months prior to collapse of applicant‟s front retaining wall.
I had noticed there was often a large amount of water on the footpath
coming from under the retaining wall.
Shortly after the applicant‟s re taining wall collapsed, I spoke to applicant
and advis ed her of the above.
FSP’s engineer (F)
Report
9 March 2017
Response to applicant‟s submission with referenc e to water usage
accounts, and 12 Feb 2017 letter from neighbour (NM)
o Applicant‟s says turf was laid in front yard late March 2016, and
required watering.
o Review of applicant‟s water usage accounts indicates spike in water
usage for 3 mont h period up to 11 April 2016 – ie: January - April
quarter, not the April - July quart er as asserted by applicant .
o Water usage for April - July quarter is only 10% more than same period
in 2015 (500l/day vs 453l/day).
o Excessive water usage ended by 11 April - approximately 4.5 months
prior to collapse of wall.
o Based on structural engineering analysis, F‟s opinion is th at wall,
which comprises unreinforced double brick construction, is grossly
deficient in capacity to resist lateral ret aining pressures from
approximately 1m of earth/soil, and approximately 1 in 6 batter
surcharge
o Earth/soil pressures contributing to wall collapse take many years
(decades) to develop and ultimately cause failure of wall. Max
acceptable height for unreinforced double brick retaining wall is
typically 450mm – significantly less that 1m height of applicant‟s wall.
o F restates that proximat e ca use of wall collapse is inadequate design
and/or construction, which has resulted over a prolonged period of
time.
Statutory
Declaration - GG
Applicants‟ gardener five years and had known and been involved in
garden maintenance of the property for 15 years.
Never seen the retaining wall to be in any state of disrepair or in fear of
collapse
New turf was laid in mid - March 2016 and laying the new turf the ground
was rotary hoed and new soil used to lay the grass.
A drip line was installed around the fron t and side garden bed resulting in
increased watering and subsequent saturation of the garden bed.
Applicants could never have foreseen improving their property would res ult
in destabilization of and collapse of the front wall.
Case No: 467232 Determination Page 11 of 11
Statutory
declaration - JM
Project Manager for construction of new retaining wall removed the debris
from the old retaining wall on 2 September 2016.
Debris contained mostly bricks, some soil and geraniums.
Remove vegetation which had not contributed to the fall as it was still inta ct
with no roots exposed.
Cut down two conifer trees which were situated approximately 1.5m back
from where the wall had been.
Conifer trees root system extended horizontally about 600mm and was
intact.
Excavator took three weeks to dig out the rock clay f or the footings for the
news wall.
The ground was all hard and rock clay and the root systems of any shrub
or trees could not penet rate more than 600mm of soil. It had been placed
on the top of the rock.
Roots could not have caused retaining wall to collap se.
Increase in water retained by soil behind the wall whic h extended only
300mm to the hard clay rock and 1. 2m vertically put pressure on the wall
and caus ed it to collapse.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.