Internal storm damage to bedroom 2 declined due to defective roof installation
Summary
The applicants claimed for internal storm damage to bedroom 2 after the FSP accepted external eaves damage. The FSP declined the internal damage and AFCA agreed.
The internal water damage was caused by defective roof installation and design, including an insufficient pitch and incorrect flashing, which the policy exclusions cover.
Issues
- Claim denial primary · not upheld“the FSP is entitled to decline cover for the internal damage in bedroom 2”
Subjects and remedies
home or building damagenatural disasterno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
Case No: 464125 Determination Page 1 of 3
Case number: 464125 7 August 2017
1 Overview
1.1 Dispute
The applicants held a building and contents insurance policy (the policy) with the
financial services provider (FSP). A claim was lodged on 12 November 2016 for
damage to the insured property caused during a storm event the previous day.
The FSP accepted the claim, however has limited its liability to the damaged eaves
whilst excluding the internal damage in bedroom 2 of the insured property. The
applicants remain dissatisfied with the FSP’s decision to decline this internal
damage.
1.2 Issues and key findings
Is the FSP obliged to cover the applicants for the internal damage?
The available information establishes the internal damage to the ceiling, ensuite,
vanity, carpet and cabinet in bedroom 2 is due to the defective installation of its
corrugated iron roof sheeting (roof sheets).
Accordingly, in line with the policy terms and conditions, the FSP is entitled to decline
cover for the internal damage in bedroom 2.
1.3 Determination
This Determination is in favour of FSP.
The FSP is not obliged to cover the internal damage in bedroom 2 in line with the
exclusions specified in the product disclosure statement (PDS).
Case No: 464125 Determination Page 2 of 3
2 Reasons for Determination
2.1 Is the applicant obliged to cover the internal damage?
The installation of bedroom 2’s roof is defective for the purpose of the policy
I have considered the available i nformation and am satisfied on balance it
establishes the following:
the insured property suffered both internal and external damage due to a heavy
storm experienced in the area of the insured property on 11 November 2016
the external damage to the eaves is the result of an overflowing of the roof
gutters and has been accepted under the claim
the internal damage referred to above was declined by the FSP on the basis it
is the result of the defective installation of the roof sheeting
the applicants arranged for the replacement of the roof sheeting in question
approximately 18 months prior to the damage occurring
an assessment of the roof shows it has a pitch of approximately 1.9 degrees
the replacement of the roof was completed with the use of corrugated iron roof
sheeting
the eaves in the area of bedroom 2 remained undamaged with no evidence of
an overflow of the roof gutters in this area of the insured property
the incorrect flashing has been used to section off the roofing adjoining the main
roof of the insured property
sealant had been applied between the roofing ribs to prevent water back flowing
under the flashing by wind driven rain
I acknowledge the applicants’ view that the insured home was constructed many
years prior and would have met the building standards in place at its time of
construction. However, it is not disputed the roof area subject of the claim was
actually removed and replaced around 18 months prior to the date of loss.
Accordingly, I am satisfied it is the building code and standards in place at the time of
the roof replacement that are relevant to the construction/installation of the roof
sheeting now present.
I accept the available information establishes on balance the internal water damage
to bedroom 2 is not the result of wind driven rain.
The FSP’s appointed consultants’ ‘C’ after having assessed the roof over bedroom 2
formed the view the water ingress and resultant damage arises from defective
installation and design of the roof.
The FSP has made available evidence in the form of the relevant building code i.e.
BCA Code 3.5.1.5 NCC2015 Volume 2. This information establishes the roof
installed over bedroom 2 required a minimum pitch of 5 degrees whilst the current
pitch sits at 1.9 degrees in line with C’s as sessment report.
I am satisfied C’s assessment and related opinion confirms that the drainage
channels of corrugated roof sheeting, restricts the release of water unless elevated to
the correct pitch to allow for water flow. Further, that in the absence of the correct
Case No: 464125 Determination Page 3 of 3
pitch the shallow scallop design of corrugated roof sheeting overlaps, allows pooling
of water and which due to this on balance penetrates sheet joints.
Further, as noted above, the available information on balance establishes incorrect
flashing had been used. In the case of a low pitch roof the use or installation of the
flashing used should be that recommended by the manufacturer of the roof sheeting
or should scribe to the profile of the roof sheeting.
Without evidence to the contrary, I am satisfied the FSP has on balance established
the proximate cause for the internal damage subject of the claim is the defective
installation and design of the roof above bedroom 2.
I acknowledge the applicants’ view that they have maintained their home in good
condition and this is their first claim in the many years they have held insurance.
However, I am not in a position to require the FSP to accept the claim for these
reasons and such a decision rests with the FSP alone.
Accordingly, in line with the exclusions specified in the PDS, the FSP is entitled to
decline the applicants’ claim for the internal damage in bedroom 2.