Home / Financial Firm (Unknown - Insurer) / Determination 464125

Determination 464125

Internal storm damage to bedroom 2 declined due to defective roof installation

FirmFinancial Firm (Unknown - Insurer)
Decided2017-08-07
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicants claimed for internal storm damage to bedroom 2 after the FSP accepted external eaves damage. The FSP declined the internal damage and AFCA agreed.

The internal water damage was caused by defective roof installation and design, including an insufficient pitch and incorrect flashing, which the policy exclusions cover.

Issues

Subjects and remedies

home or building damagenatural disasterno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 464125 Determination Page 1 of 3 Case number: 464125 7 August 2017 1 Overview 1.1 Dispute The applicants held a building and contents insurance policy (the policy) with the financial services provider (FSP). A claim was lodged on 12 November 2016 for damage to the insured property caused during a storm event the previous day. The FSP accepted the claim, however has limited its liability to the damaged eaves whilst excluding the internal damage in bedroom 2 of the insured property. The applicants remain dissatisfied with the FSP’s decision to decline this internal damage. 1.2 Issues and key findings Is the FSP obliged to cover the applicants for the internal damage? The available information establishes the internal damage to the ceiling, ensuite, vanity, carpet and cabinet in bedroom 2 is due to the defective installation of its corrugated iron roof sheeting (roof sheets). Accordingly, in line with the policy terms and conditions, the FSP is entitled to decline cover for the internal damage in bedroom 2. 1.3 Determination This Determination is in favour of FSP. The FSP is not obliged to cover the internal damage in bedroom 2 in line with the exclusions specified in the product disclosure statement (PDS). Case No: 464125 Determination Page 2 of 3 2 Reasons for Determination 2.1 Is the applicant obliged to cover the internal damage? The installation of bedroom 2’s roof is defective for the purpose of the policy I have considered the available i nformation and am satisfied on balance it establishes the following:  the insured property suffered both internal and external damage due to a heavy storm experienced in the area of the insured property on 11 November 2016  the external damage to the eaves is the result of an overflowing of the roof gutters and has been accepted under the claim  the internal damage referred to above was declined by the FSP on the basis it is the result of the defective installation of the roof sheeting  the applicants arranged for the replacement of the roof sheeting in question approximately 18 months prior to the damage occurring  an assessment of the roof shows it has a pitch of approximately 1.9 degrees  the replacement of the roof was completed with the use of corrugated iron roof sheeting  the eaves in the area of bedroom 2 remained undamaged with no evidence of an overflow of the roof gutters in this area of the insured property  the incorrect flashing has been used to section off the roofing adjoining the main roof of the insured property  sealant had been applied between the roofing ribs to prevent water back flowing under the flashing by wind driven rain I acknowledge the applicants’ view that the insured home was constructed many years prior and would have met the building standards in place at its time of construction. However, it is not disputed the roof area subject of the claim was actually removed and replaced around 18 months prior to the date of loss. Accordingly, I am satisfied it is the building code and standards in place at the time of the roof replacement that are relevant to the construction/installation of the roof sheeting now present. I accept the available information establishes on balance the internal water damage to bedroom 2 is not the result of wind driven rain. The FSP’s appointed consultants’ ‘C’ after having assessed the roof over bedroom 2 formed the view the water ingress and resultant damage arises from defective installation and design of the roof. The FSP has made available evidence in the form of the relevant building code i.e. BCA Code 3.5.1.5 NCC2015 Volume 2. This information establishes the roof installed over bedroom 2 required a minimum pitch of 5 degrees whilst the current pitch sits at 1.9 degrees in line with C’s as sessment report. I am satisfied C’s assessment and related opinion confirms that the drainage channels of corrugated roof sheeting, restricts the release of water unless elevated to the correct pitch to allow for water flow. Further, that in the absence of the correct Case No: 464125 Determination Page 3 of 3 pitch the shallow scallop design of corrugated roof sheeting overlaps, allows pooling of water and which due to this on balance penetrates sheet joints. Further, as noted above, the available information on balance establishes incorrect flashing had been used. In the case of a low pitch roof the use or installation of the flashing used should be that recommended by the manufacturer of the roof sheeting or should scribe to the profile of the roof sheeting. Without evidence to the contrary, I am satisfied the FSP has on balance established the proximate cause for the internal damage subject of the claim is the defective installation and design of the roof above bedroom 2. I acknowledge the applicants’ view that they have maintained their home in good condition and this is their first claim in the many years they have held insurance. However, I am not in a position to require the FSP to accept the claim for these reasons and such a decision rests with the FSP alone. Accordingly, in line with the exclusions specified in the PDS, the FSP is entitled to decline the applicants’ claim for the internal damage in bedroom 2.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.