Home / Financial Firm (Unknown - Insurer) / Determination 463425
Determination 463425
Claim for collapsed garage ceiling denied under gradual deterioration exclusion
Summary
A unit owner's claim for a collapsed garage ceiling, said to be caused by a storm and water ingress, was denied under the gradual deterioration exclusion. AFCA accepted expert evidence that the ceiling collapsed from its installation and long-term water leaks, and found the FSP was entitled to decline.
The FSP bore the onus on the exclusion and met the balance of probabilities by showing the collapse resulted from a long-running process consistent with gradual deterioration rather than a one-off event.
Subjects and remedies
home or building damageno remedy
Text of the determination
Determination
Case No: 463425 Determination Page 1 of 3
Case number: 463425 30 June 2017
1 Overview
1.1 Dispute
The applicant’s claim for a collapsed garage ceiling was denied by the residential
strata insurer, the financial services provider (FSP), on the basis it was due to
gradual deterioration or wear and tear.
The applicant has disputed this as she says the damage was due to water ingress
following a storm.
1.2 Issues and key findings
Can the FSP deny the claim?
The FSP can deny the claim because:
the evidence shows the ceiling collapsed due to its manner of installation and
continual water leaks
this is consistent with gradual deterioration
the policy excludes loss or damage caused by gradual deterioration
1.3 Determination
This determination is in favour of the FSP.
The FSP is entitled to deny liability for the applicant’s claim.
Case No: 463425 Determination Page 2 of 3
2 Reasons for determination
2.1 Can the FSP deny the claim?
FSP relying on a policy exclusion
These relevant facts are not in dispute:
a claim was lodged on 25 July 2016 for the collapsed garage ceiling
there were two previous instances of water ingress – one in 2011 and another
in early 2015
the applicant addressed both instances by changing the old gutters (2011) and
sealing the entry point with silicone (2015)
The policy responds in the following circumstances:
“ This Policy covers accidental loss or damage to your insured property (building and common
area contents) that occurs during the period of insurance . ”
There is no dispute this has been satisfied. However, the FSP is relying upon the
following exclusion:
“1. We will not pay for loss or damage:
c. caused by … gradual deterioration …”
The FSP has the onus of proof in establishing the exclusion. The standard of proof is
the balance of probabilities.
Four expert opinions have been provided
An opinion was provided by JL which says:
“Regarding your request about the reason how the whole ceiling collapse in you garage? From
the building technical view, there are 4 reasons:
1. The existing ceiling used 16mm fire resistant plasterboa rd, it is heavier than normal 10mm
plasterboard;
2. The ceiling joists spacing is 1 metre wide whic h is bigger than normal 450mm or 600mm;
provide the less support to the battens;
3. The battens spacing is 700mm which is also to bigger than 450mm; serious part i s the
battens had been used one nail to fix on the junction to each joists;
4. Such as garage motor directly fix to the battens, which is add more gravity to the battens;
This is why the whole ceiling collapses with battens.” [sic]
Another report was completed by SR which said:
“The damage has been caused by a consistent water leak which is prevalent on the back of the
plaster now on the ground. It has been breaking down over the years and in the end has lead to
the fixings in the battens to give way collapsing the ceiling wit h the timber battens also coming
down.”
A brief opinion was provided by MC that said:
“Appears damaged by long time water leak (TBC)”
The FSP had a loss adjuster (DB) review the damage. DB provided a report dated 29
September 2016 that says:
“Our enquiries with [applicant] advised that upon purc hasing the unit approximately 5 years ago,
she found isolated areas of water damage to the garage ceiling, which became progressively
wors e leading up to the collaps e. Furthermore, approximately 12 months ago, she found the
plasterboard had split following a heavy rain storm.
At the owners own admission, she failed to engage any contractors to inspect the roof, identify
causation and/or to repair the garage ceiling.
…
Our inspection and subsequent enquiries suggest faulty workmanship, inadequate fixings and
long term water damage are all contributing factors that have caused Unit 3’s garage ceiling to
collapse.
Case No: 463425 Determination Page 3 of 3
The owner confirmed sighting evidence of long-term water leaks which have progressively
wors ened in the absence of carrying out necessary roof maintenance repairs.”
JL and SR opinions preferred
I am not persuaded by MC’s or DB’s opinion for the following reasons.
MC’s opinion has been offered with no reasoning or analysis in support.
DB’s op inion followed a number of assumptions that are inconsistent with the
evidence. For instance:
DB said the applicant failed to identify roof leaks or maintain the property – the
applicant has refuted this by providing evidence showing she engaged
contractors to address the potential water ingress sources promptly
DB said there were isolated areas of water damage that were progressively
worse – the applicant’s unrefuted evidence is that there were only two instances
of water ingress which she addressed.
Ther efore, I do not accept DB’s conclusion as to the likely cause of damage.
I do consider JL’s and SR’s opinions to be the most persuasive. JL’s reasoning about
why the ceiling collapsed is plausible. Whilst SR appears to have arrived at a
different conclusion, I consider the two can be reconciled.
JL’s opinion is the ceiling would have inevitably collapsed due to the weight attached
to the battens and the manner of installation. SR said the collapse was due to a
consistent water leak. It is clear water ingress to the ceiling would exacerbate the
weight on the plaster and accelerate its collapse.
Therefore, I consider the two opinions are relatively consistent and provide a
plausible and logical explanation behind the garage ceiling collapse.
FSP can deny the claim
Given the above, I accept the evidence shows the garage ceiling collapsed due to its
manner of installation and consistent water leaks.
I also accept this process would have occurred over a long period of time. This is
consistent with gradual deterioration rather than a one off water ingress event.
Therefore, I accept the FSP has shown the damage was due to gradual deterioration.
As this falls within a policy exclusion, the FSP is entitled to deny liability for the
applicant’s claim.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.