Home / Financial Firm (Unknown - Insurer) / Determination 461892
Determination 461892
Declined storm claim for collapsed cellar earth wall
Summary
The applicants' cellar earth wall collapsed after a violent storm in October 2014 and the FSP denied the claim, citing erosion, subsidence and faulty design. AFCA found the storm was the proximate cause, no exclusion was established, and ordered payment of $57,200 repair costs plus interest.
The storm was the dominant effective cause of the collapse and the FSP did not establish that an excluded cause was a concurrent proximate cause.
Issues
- Claim denial primary · upheld
“The panel is not satisfied that the FSP has established the application of an exclusion to defeat the applicants' claim.”
- Claim amount dispute secondary · upheld
“The panel accepts that the applicants have acted reasonably and that it is fair they be compensated for the $57,200 repair cost.”
Subjects and remedies
home or building damagenatural disasterpay claimpay interest
Text of the determination
Determination
Case No: 461892 Determination Page 1 of 8
Case number: 461892 27 February 2018
1 Overview
1.1 Dispute
The applicants lodged a claim on their building insurance policy after an earth wall in
their cellar collapsed due to water ingress from a violent storm on 15 October 2014.
The FSP denied the applicants’ claim on the basis the policy did not respond . The
FSP says the collapse of the wall was due to erosion over time leading to subsidence
or landslide and/ or due to faulty design and workmanship.
The applicants dispute the FSP’s findings.
1.2 Issues and key findings
Has the applicant established a claimable loss?
The policy provides cover for damage caused by a storm. The panel is satisfied that
the water ingress resulting in the collapse of the earth wall was caused by a storm.
The panel is satisfied in the circumstances the applicants have established a claim
that falls within the terms of the policy.
Has the FSP established an exclusion applies?
The panel is not satisfied that the FSP has established the application of an
exclusion to defeat the applicants’ claim. The panel is not satisfied the loss or
damage was caused by erosion over time, subsidence or landslide or faulty design
and workmanship.
1.3 Determination
This determination is in favour of the applicants.
The FSP is to meet the applicants claim in accordance with the terms and conditions
of the policy and pay the applicants $57,200 being the cost of the repairs in the repair
process. Further interest is payable in accordance with Section 57 of the Insurance
Contracts Act 1984 (the Act) from the 15 February 2015 as set out under paragraph
2.2.
Case No: 461892 Determination Page 2 of 8
2 Reasons for determination
There has been a full exchange of material between the parties and each party has
had the opportunity to address the issues that arise from the information exchanged.
In view of the complexities involved in this dispute, it has been referred to a panel for
determination. This determination follows consideration of all of the information
available and is based on what is fair in all the circumstances having regard to the
relevant legal principles, terms of the policy, good industry practice including codes of
practice and prior determinations where applicable.
2.1 Have the applicants established claimable loss?
The applicants have the onus to establish a claim within the terms of the policy
The applicants have the onus to establish on the balance of probabilities a claim that
falls within the terms of the policy.
The applicants’ policy , a Home Building and Contents Policy, provided cover for a
series of defined events including storm subject to a number of exclusions.
The applicants believe the damage to the earth wall arose as a result of a storm. In
the circumstances, the onus is on the applicants to show, on the balance of
probabilities that the damage resulted from a storm.
The applicants have established an insured event
An extreme weather event occurred on 15 October 2014, with the Bureau of
Meteorology reporting rainfall of 82.4mm that day – which is 22.4mm over the
threshold for a storm to be considered violent.
On 28 November 2014, the applicants discovered the earth wall in their cellar had
collapsed and water had entered the property. They lodged a claim and advised the
FSP that they believed the collapse to be the result of the October storm event.
The applicants obtained an engineering report from MLE who attended the property
on 10 December 2014. MLE concluded that the violent storm was responsible for the
failure/erosion of the earth wall.
A second engineering report was obtained from RR. RR also concluded that due to
the low permeability of the soil that formed the earth wall only events similar to that of
15 October 2014 would cause the erosion.
The panel is satisfied on the basis of the reports provided that the applicants have
established a claim for the damage to the earth wall arising from the insured event of
storm.
2.2 Has the FSP established an exclusion applies?
The FSP has argued that the collapse of the wall was as a result of:
Erosion
Subsidence
Case No: 461892 Determination Page 3 of 8
Faulty design or workmanship.
Each of these causes is excluded under the terms of the policy and the onus is on
the FSP if it wishes to establish the application of any of these exclusions.
DWK report not persuasive
The FSP has relied upon a report from an engineer DWK.
DWK concluded that the erosion of the earth wall was due to faulty design as a result
of a localised failure of the unrestrained excavation face of the wall and natural
seepage.
DWK noted the following issues arose with the construction of the earth wall:
Excavation of the natural soil within the subfloor area consisted of a vertical cut
face and steep battering. The natural material consists of extremely weathered
shale with no formal retaining system.
Water would naturally flow through the block from north to south via natural
seepage wetting the unrestrained vertical cut face of the original excavation.
Permanent soil batters require a minimum permanent batter of 1V:2H - 30° to
horizontal to remain stable.
In the absence of additional i nformation, the localized failure of the unrestrained
excavation face was consistent with moisture infiltration over a significant period
of time from a number of storm events.
The damage arose due to a faulty design, construction resulting in erosion and
failure of the wall.
Pre Purchase report indicates no evidence of water seepage
The pre purchase report from CBR following an inspection of the earth wall on 19
February 2014 notes there was no visible seepage and no evidence of previous
seepage.
The pre purchase report findings are inconsistent with the comments by DWK that
the wall had weakened over the years as a result of repeated moisture ingress.
In the panel’s view, previous water seepage would have been evident as at 19
February 2014 if it had occurred. The panel accepts there was no evidence of water
seepage prior to 14 February 2014.
Proximate cause of the collapse was the extreme storm event
The pre purchase report from CBR identifies there were no visible signs of seepage
or evidence of previous seepage. The panel is satisfied that the damage or signs of
damage did not exist prior to 19 February 2014.
There is no information to show any erosion or subsidence or seepage impacting on
the wall prior to the storm on 15 October 2014.
MLE noted that substantial seepage had occurred as a result of the storm on 15
October 2014. According to MLE the substantial seepage led to a significant increase
in the applied pressure which caused the failure of the wall.
In the report dated 20 January 2015 MLE described the earth wall as follows:
Case No: 461892 Determination Page 4 of 8
‘ behind the rear garage there is localised excavated material of approximately 1m high
battered at an angle of 45m also and then dropping approximately 2m vertically. Partial
erosion of the excavated material occurred between 16 October 2014 and
21 November 2014. ’
MLE considered the storm and not a building defect caused the failure of the wall.
RR in a report dated 3 March 2017 notes:
the earth wall was an angled earth batter wall;
there was no previous erosion evident and
the ground water seepage due to the violent high intensity storm was the cause
of the movement.
According to RR, the storm had compromised the integrity of the wall and the repairs
were required for that reason. RR considered the DWK report did not adequately
consider the soil characteristics when stating the earth batter wall was inadequate.
The proximate cause of a loss is the effective or operative cause. It is not necessarily
the first or last cause in a chai n of events but is the dominant or effective cause of the
loss. The panel is not persuaded by the report from DWK. The panel accepts the
findings in the pre purchase report, and of MLE and RR that the proximate cause,
that is, the dominant or effective cause of the loss was the storm of 15 October 2014.
FSP has not established the application of the exclusions
The FSP says that in the event the Service does consider an insured event has
occurred, it is still protected by the Wayne Tank principle on the basis that the
construction of the wall itself is also fundamental to the loss.
The Wayne Tank principle applies that where the proximate cause of damage is both
an insured event and an excluded event. If both, then the excluded event applies to
defeat the claim. The panel acknowledges that if the FSP could establish that an
excluded event was a concurrent proximate cause of the loss, then it would be
entitled to refuse payment of the claim.
The panel is not satisfied however that a design defect, erosion or la ndslide was a
concurrent proximate cause of the loss.
As indicated earlier, the panel notes that the re is insufficient information to support
the finding by DWK that the surface had weakened and was unstable as a result of
repeated moisture ingress. There is no information that there had been any moisture
ingress at any time prior to the storm on 15 October 2014. The panel prefers the
findings of MLE and RR that the movement was caused as a result of the ground
water seepage due to the high intensity storm.
In the circumstances, the panel is not satisfied the FSP has established the
application of an exclusion such that the Wayne tank principle is engaged. The panel
is satisfied that the FSP is liable to meet the applicant’s claim.
FSP is liable to meet the costs incurred by the applicant
The FSP says that the policy only requires it to effect repairs or rebuild that part of
the home that was damaged. It says that to build a retaining wall would be an
Case No: 461892 Determination Page 5 of 8
upgrade. The panel notes that both parties’ experts have identified that it is
necessary to rectify the collapsed wall. Both experts identify that it is necessary for a
new structure, a retaining wall, to be built.
DWK considers that whilst the stability of the dwelling had not been compromised,
any further loss of soil carried the risk of causing distress to the structures above.
The panel accepts that such damage falls within the terms of the policy.
The applicants say they have followed the instructions contained in the FSP’s letter
of 6 January 2015. That le tter advised that the FSP’s expert had recommended a
retaining wall be built ‘to prevent any further damage’. The letter indicated it was the
applicants’ responsibility to ensure this was completed to mitigate any further
damage to the home.
Even though t he applicants were contesting the FSP’s decision at this time, they
complied with the FSP’s instructions in good faith and in accordance with the policy
terms which are to maintain their home in good repair and condition. They had the
repairs completed by 15 February 2015.
There is no suggestion in any report that the earth wall can be repaired. Rather the
suggestions from DWK is that either a retaining wall is built or a conventional
cantilever reinforce block work system is put in place . The FSP’s enginee r RR
confirmed that the earth batter wall cannot be repaired and considers that a retaining
wall would be the optimum solution.
The FSP is liable to meet the cost incurred by the applicants
The panel has considered the options put forward by the FSP and th e applicants’
experts and notes that the applicants have undertaken to build the retaining wall
based on the information provided by the FSP.
The panel accepts that the applicants have acted reasonably and consistent with the
terms of the policy. It is fair in the circumstances that the applicants be compensated
for their loss.
The applicants obtained a quote from AA for the completion of the repairs and
construction of the retaining wall for $57,200. The applicants had the repairs
completed based on this quotation by 15 February 2015.
Accordingly the panel determines that the FSP pay the applicants in accordance with
the terms of the policy the cost of repairs of $57,200. Interest calculated in
accordance with section 57 of the Act should be paid on the $57,200 from the date
on which the applicants paid for the repairs to date of payment of the claim. The
applicants will need to provide a copy of the relevant invoice to the FSP to confirm
the date of payment.
Case No: 461892 Determination Page 6 of 8
3 Supporting information
3.1 Terms of the policy
Subject Terms
Section 2
Buildings and contents we
insure
Under buildings insurance, we insure certain types of buildings,
Your home
Your home includes:
domestic residential buildings at your site that can be locked up
home improvements at your site – for example garage, carport, in -
ground pool
fixtures or items permanently atta ched or fixed to your home – for
example, light fixtures, built in wardrobes, kitchen cupboards and
floating floorboards
The events we cover
Storm
Page 23
Covered
violent wind, cyclone or tornado
thunderstorm, hail, rain or snow
sudden excessive run off water as a direct result of a storm in your
local area
Exclusions for all cover
These exclusions apply to
all cover under your policy
Page 53
What we don’t cover
Loss, damage, injury of death arising from:
erosion
subsidence or landslide
Maintaining and occupying your home
We don’t cover loss, damage, injury or death arising from:
faulty design or workmanship
you not maint aining your home in good repair and condition. This
means your home must be watertight, structurally sound, secure
and well maintained
3.2 Relevant documentation
Document Key Points
CBR (APP’ s expert)
Pre - purc hase inspection
report
19 February 2014
At the rear of the garage is a storage area with the natural
excavated ground in the background. There was no visible
seepage this date, or e vidence of previous seepage.
DWK (FSP’ s expert)
Engineering report
23 December 2014
Building was originally constructed in 2006. The Insured has
owned the property since February 2014
Insured has advised that following an intense rain period on
15.10. 14, the excavation cut face behind the rear basement garage
door has collaps ed
Case No: 461892 Determination Page 7 of 8
We have viewed the pre - purchase building inspection report
The rear subsurface drainage and surface drainage above the
subject area have been tested and are understood to be
functioning adequately
On the day in question BOM has recorded rainfall at 82.4mm and
this would be considered violent (>50 mm is violent)
The localised failure of the unrestrained excavation face is
consistent with moisture infiltration over a significant period of time
from a number of storm events
It is possible that the failure of the cut face occurred as claimed,
due to the weakened and unstable face that had developed over
the years as a result of repeated moisture ingress
Consider the erosion/ failure of the excavation face to be an
inherent original design/construction issue
The stability of the dwelling does not appear to have been
compromised at th is stage however the piers and strip f ootings are
unreinforced and therefore not designed to wit hstand lateral
loading from being exposed on one side.
Further loss of soil carries the risk of causing local footing
movement and distress to the structure above
Recommendations: either a formal re t aining system or a
conventional cantilever reinforced block - work system
MLE (APP’ s expert)
E ngineering report
20 January 2015
Attended property on 10 December 2014
Visible inspection of the excavated materials reveals that approx. 2
metres of the materi al has a straight vertical line which indicates
that such failure/erosion has not happened before
I would consider that the violent storm is responsible for the
failure/erosion of the excavated materials
RR (APP’ s expert)
Engineering report
18 January 2015
Erosion rates are dependent on seepage rates which accelerate
erosion
Seepage is dependent on the permeability of the soil whic h relat es
to the soil characteristics
The soil is clay which is reputably a very slow seeping soil due to
its fine nature an d small voids, limiting the velocity of ground water
through it
Therefore, due to the low permeability of the soil only events
similar to that of 15 October 2014 may cause erosion
(FSP) may wish to obtain their own report from other than DWK
who do not app ear to be a qualified specialist geotechnical
engineer, based on the opinions made
FSP decline letter
Correspondence
6 January 2015
A recommendation has been made by DWK that a formal retaining
system is required to prevent further damage from occurring
It is your responsibility to ensure this is completed to mitigate the
risk of any further damage to your home
Report included for your review and action
RR (APP’ s expert)
Correspondence
3 March 2017
The wall in question was an angled earth batter wall
The earth batter wall is not regarded as a retaining wall
Erosion was not evident in the pre - purchase report
The earth batter wall had a drainage system as witnessed by MLE
Case No: 461892 Determination Page 8 of 8
The ground movement caused from ground water seepage due to
the violent high intensity storm in November 2014 is not deemed
erosion by any means
Also refutes that it can be considered subsidence
The storm event had compromised the int egrity of the wall and
therefore repairs were required for this reason
DWK report does not take into account the soil characteristics
when stating the earth batter wall was inadequate. 1V:2H and
1V:1H is adequate given the soil conditions.
Rectification to reinstate the earth batter wall in its original form
was not recommended and cannot be achieved, and theref ore
required a wall system as recommended by both parties’ experts.
(APP) received a letter from the FSP dated 2 Dec ember 2014
stating ‘it is your responsibility to ensure this is completed to
mitigate the risk of any further damage to your home’, and
cons idered it to be a direction pursuant to page 53 of the
supplementary PDS and thus commissioned a builder to follow
through with the rec ommendations, despite the claim not being
fully closed
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.