Home / Financial Firm (Unknown - Insurer) / Determination 460533
Determination 460533
Claim for damaged milk vat denied under wear and gradual deterioration exclusion
Summary
The applicant's milk vat suffered a sudden crack at a weld and she claimed under machinery breakdown cover. AFCA found the failure was caused by gradual thermal fatigue from ordinary cleaning and cooling use, so the wear exclusion applied and the FSP could deny the claim.
The wear and gradual deterioration exclusion applies where a sudden failure results from a gradual process of ordinary use, even if the crack itself was unforeseen.
Issues
- Claim denial primary · not upheld
“The FSP is entitled to deny liability for the claim; the crack resulted from wearing caused by ordinary use of the vat.”
- Product terms interpretation secondary · not upheld
“The exclusion cannot be interpreted to be limited to parts subject to periodic replacement or repair.”
Subjects and remedies
no remedy
Text of the determination
Determination
Case No: 460533 Determination Page 1 of 5
Case number: 460533 4 April 2017
1 Overview
1.1 Dispute
The applicant’s claim for a damaged milk vat was denied by her insurer, the financial
services provider (FSP), on the basis a part within the vat had worn.
The applicant has disputed this as she says the evidence does not show that this is
the cause of damage.
1.2 Issues and key findings
Can the FSP deny the claim?
The FSP can deny the claim because:
the evidence shows the damage was due to a crack in a pipe caused by metal
fatigue
the metal fatigue resulted from the cleaning and cooling process of the vat – this
process subjected the pipe to expansion and contraction over time
this falls within the policy exclusion for the wearing of a part caused by the
operation of the vat
1.3 Determination
This determination is in favour of the FSP.
The FSP is entitled to deny liability for the claim.
Case No: 460533 Determination Page 2 of 5
2 Reasons for determination
2.1 Can the FSP deny the claim?
FSP relying upon an exclusion clause
The applicant holds a farm policy that includes machinery breakdown cover. The
claim is lodged under that section of the policy.
The insuring provision is set out as follows:
“ We will cover loss or damage to Your Property Insured caused by Breakdown which occurs
during the Period of Insurance .”
Breakdown is defined to mean:
“… unforeseen and sudden physical loss or damage to the Property Insured from any cause
which is not excluded under Section Eight and which results in the Property Insured having to
be repaired or replac ed before it can be used again .”
“Property Insured” specifically includes a milk vat.
There is no dispute the vat suffered unforeseen and sudden physical loss. Therefore,
the circumstances of the loss satisfy the insuring provision.
The FSP is relying upon the following policy exclusion:
“We will not pay for: …
3. any:
a) wasting or wearing away or wearing out of any part of Property Insured
caused by or naturally resulting from ordinary use of working;
b) gradual deterioration including erosion, rust, corrosion, boiler scale or
oxidation (due to normal atmos pheric conditions or otherwise); ”
The FSP has the onus of proof in establishing either of the exclusions apply. The
standard of proof is the balance of probabilities.
Cause of damage falls within policy exclusion
Numerous experts have reviewed the matter and provided an opinion. Their opinions
are set out in section 3.1 of this Determination.
The experts are consistent in identifying the likely cause of failure. Namely, thermal
fatigue fracture at the weld of a pipe. This was caused by the expansion and
contraction of the metal pipe through the vat’s cooling and cleaning process.
The policy excludes the “wearing out of any part of Property Insured caused by or
naturally resulting from ordinary use o f working”.
Wearing, or wear, has been defined by a number of dictionaries to mean:
“The proc ess or condition of being worn or gradually reduced in bulk or impaired in quality by
continued use, friction, attrition, exposure to atmos pheric or other natural destructive agencies;
loss or diminution of substance or deterioration of quality due to these causes [Oxford English
Dictionary]
To impair, deteriorate or consume gradually by use or any continued process [Macquarie
Dictionary]
Damage, erode, or destroy by friction or use [Oxford online dictionary]”
All these definitions are relatively consistent. They say wear occurs when an item is
impaired or damaged through a gradual process.
Case No: 460533 Determination Page 3 of 5
I am satisfied that is the case here. The experts are consistent in saying the weld join
suffered fatigue due to contraction and expansion associated with the milk vat’s
cleaning and cooling process.
Therefore, whilst the crack was sudden and unforeseen, the process that led to this
was gradual and through the ordinary use of the vat (ie the cleaning and cooling
process).
This falls within the policy exclusion.
Applicant’s arguments do not assist her
The applicant has argued the following regarding the application of the exclusion:
there was no wearing of any part – this is evident by the fact the item that failed
did not require periodic replacement or repair
the crack was sudden and unforeseen
I do not accept these arguments assist her for the following reasons.
First, the policy exclusion cannot be interpreted to be limited to parts that are subject
to periodic replacement or repair. The words used, or their plain meaning, do not
support such an interpretation.
Instead, I accept the exclusion applies if the FSP can show the claim arose from a
part that was impaired through a gradual process that falls within the ordinary use of
the vat. For reasons explained, I am satisfied this is the case.
Second, there is no dispute the crack was sudden and unforeseen. This falls within
the insuring provision. However, the evidence also shows the above exclusion
applies. This is consistent with the intent of an exclusion clause. Namely, to exclude
liability for matters that otherwise fall within the insuring provision.
Therefore, after careful consideration of all the evidence and arguments, I am
satisfied the FSP is entitled to deny liability for the claim.
Case No: 460533 Determination Page 4 of 5
3 Supporting information
3.1 Expert evidence
Record Key points
App’s repairer (W )
Invoice
15 July 2016
Located leak in right hand side of vat looking from the front
FSP’s expert ( FA )
Report
07 August 2016
Cont acted the repairer [W]
W advised the leak is internal within the refrigerant dimple
plate
W indicated the cause is related to the expansion and
contraction of the plate as occurs overtime
No other external factors were identified
FSP’s expert (DA)
Report
12 September 2016
In our discussion wit h W and P (manufacturer’s distribut or),
most likely cause of the refrigerant pipe leak is due to a crack
resulting from metal fatigue
The process of the vat operation causes expansion and
contraction of the refrigeration pipe
This, over its life, results in fatigue and a crack will event uate
App’s repairer (W)
Email
17 October 2016
From time to time, these tanks get leaks within the ja ckets
This can sometimes occur from ex pansion, sometimes due to
other reasons
Only one jacket failed – cannot give an accurate reason
without breaking open the outer skin and dissecting the exact
location of the leak
Manufacturer’s
distributor (P)
Email
9 November 2016
Due to heat and contraction through heating and cooling, the
internal pipe work overtime can develop a fracture
This causes refrigerant gases to leak
Until the vessel is opened up in a factory environment, it is
very hard to determine the ex act cause of the internal leak
FSP’s expert (DA)
Report
10 November 2016
In furt her discussions with P, he advised that in every case
bar one, the leak within the refrigerant pipework is due to
fatigue from thermal expansion/cont raction
While the cause appears determined with some surety, it
cannot be confirmed without question until the jacket/dimple
plate is exposed
FSP’s expert (DA)
Email
18 July 2016
P opened the outer sheath of the tank and identified the
location of the leak
The leak is at a weld join at the junction of a take off pipe
from the dimple plat e to the refrigerant return pipe towards
the rear of the tank
The leak is consistent with fatigue caused through the
expansion and contraction of the metal pipe through the
cooling and cleaning p rocess
Case No: 460533 Determination Page 5 of 5
The leak identified is not unusual for a tank of this age
App’s expert (BS)
Report
28 July 2017
The heating and cooling of the milk vat may result in thermal
fatigue fracture, normally at the welds
This is quite rare as the welds are checked and tested when
the milk vat is manufactured
The technician had pressurised the dimple plate vat and
sprayed liquid soap at the point where the fracture was
detected
We saw soap bubbles increase in size verifying that there
was a gas leak – most likely at the weld
App’s repairer
Email
15 August 2017
The leak is caused by metal fatigue due to heat and
contraction of the stainless steel
Many factors can lead to this happening over the years of
usage – but the root cause is metal fatigue
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.