Home / Financial Firm (Unknown - Insurer) / Determination 460533

Determination 460533

Claim for damaged milk vat denied under wear and gradual deterioration exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2017-08-28
ProductGeneral Insurance · Business / commercial
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant's milk vat suffered a sudden crack at a weld and she claimed under machinery breakdown cover. AFCA found the failure was caused by gradual thermal fatigue from ordinary cleaning and cooling use, so the wear exclusion applied and the FSP could deny the claim.

The wear and gradual deterioration exclusion applies where a sudden failure results from a gradual process of ordinary use, even if the crack itself was unforeseen.

Issues

Subjects and remedies

no remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 460533 Determination Page 1 of 5 Case number: 460533 4 April 2017 1 Overview 1.1 Dispute The applicant’s claim for a damaged milk vat was denied by her insurer, the financial services provider (FSP), on the basis a part within the vat had worn. The applicant has disputed this as she says the evidence does not show that this is the cause of damage. 1.2 Issues and key findings Can the FSP deny the claim? The FSP can deny the claim because:  the evidence shows the damage was due to a crack in a pipe caused by metal fatigue  the metal fatigue resulted from the cleaning and cooling process of the vat – this process subjected the pipe to expansion and contraction over time  this falls within the policy exclusion for the wearing of a part caused by the operation of the vat 1.3 Determination This determination is in favour of the FSP. The FSP is entitled to deny liability for the claim. Case No: 460533 Determination Page 2 of 5 2 Reasons for determination 2.1 Can the FSP deny the claim? FSP relying upon an exclusion clause The applicant holds a farm policy that includes machinery breakdown cover. The claim is lodged under that section of the policy. The insuring provision is set out as follows: “ We will cover loss or damage to Your Property Insured caused by Breakdown which occurs during the Period of Insurance .” Breakdown is defined to mean: “… unforeseen and sudden physical loss or damage to the Property Insured from any cause which is not excluded under Section Eight and which results in the Property Insured having to be repaired or replac ed before it can be used again .” “Property Insured” specifically includes a milk vat. There is no dispute the vat suffered unforeseen and sudden physical loss. Therefore, the circumstances of the loss satisfy the insuring provision. The FSP is relying upon the following policy exclusion: “We will not pay for: … 3. any: a) wasting or wearing away or wearing out of any part of Property Insured caused by or naturally resulting from ordinary use of working; b) gradual deterioration including erosion, rust, corrosion, boiler scale or oxidation (due to normal atmos pheric conditions or otherwise); ” The FSP has the onus of proof in establishing either of the exclusions apply. The standard of proof is the balance of probabilities. Cause of damage falls within policy exclusion Numerous experts have reviewed the matter and provided an opinion. Their opinions are set out in section 3.1 of this Determination. The experts are consistent in identifying the likely cause of failure. Namely, thermal fatigue fracture at the weld of a pipe. This was caused by the expansion and contraction of the metal pipe through the vat’s cooling and cleaning process. The policy excludes the “wearing out of any part of Property Insured caused by or naturally resulting from ordinary use o f working”. Wearing, or wear, has been defined by a number of dictionaries to mean: “The proc ess or condition of being worn or gradually reduced in bulk or impaired in quality by continued use, friction, attrition, exposure to atmos pheric or other natural destructive agencies; loss or diminution of substance or deterioration of quality due to these causes [Oxford English Dictionary] To impair, deteriorate or consume gradually by use or any continued process [Macquarie Dictionary] Damage, erode, or destroy by friction or use [Oxford online dictionary]” All these definitions are relatively consistent. They say wear occurs when an item is impaired or damaged through a gradual process. Case No: 460533 Determination Page 3 of 5 I am satisfied that is the case here. The experts are consistent in saying the weld join suffered fatigue due to contraction and expansion associated with the milk vat’s cleaning and cooling process. Therefore, whilst the crack was sudden and unforeseen, the process that led to this was gradual and through the ordinary use of the vat (ie the cleaning and cooling process). This falls within the policy exclusion. Applicant’s arguments do not assist her The applicant has argued the following regarding the application of the exclusion:  there was no wearing of any part – this is evident by the fact the item that failed did not require periodic replacement or repair  the crack was sudden and unforeseen I do not accept these arguments assist her for the following reasons. First, the policy exclusion cannot be interpreted to be limited to parts that are subject to periodic replacement or repair. The words used, or their plain meaning, do not support such an interpretation. Instead, I accept the exclusion applies if the FSP can show the claim arose from a part that was impaired through a gradual process that falls within the ordinary use of the vat. For reasons explained, I am satisfied this is the case. Second, there is no dispute the crack was sudden and unforeseen. This falls within the insuring provision. However, the evidence also shows the above exclusion applies. This is consistent with the intent of an exclusion clause. Namely, to exclude liability for matters that otherwise fall within the insuring provision. Therefore, after careful consideration of all the evidence and arguments, I am satisfied the FSP is entitled to deny liability for the claim. Case No: 460533 Determination Page 4 of 5 3 Supporting information 3.1 Expert evidence Record Key points App’s repairer (W ) Invoice 15 July 2016  Located leak in right hand side of vat looking from the front FSP’s expert ( FA ) Report 07 August 2016  Cont acted the repairer [W]  W advised the leak is internal within the refrigerant dimple plate  W indicated the cause is related to the expansion and contraction of the plate as occurs overtime  No other external factors were identified FSP’s expert (DA) Report 12 September 2016  In our discussion wit h W and P (manufacturer’s distribut or), most likely cause of the refrigerant pipe leak is due to a crack resulting from metal fatigue  The process of the vat operation causes expansion and contraction of the refrigeration pipe  This, over its life, results in fatigue and a crack will event uate App’s repairer (W) Email 17 October 2016  From time to time, these tanks get leaks within the ja ckets  This can sometimes occur from ex pansion, sometimes due to other reasons  Only one jacket failed – cannot give an accurate reason without breaking open the outer skin and dissecting the exact location of the leak Manufacturer’s distributor (P) Email 9 November 2016  Due to heat and contraction through heating and cooling, the internal pipe work overtime can develop a fracture  This causes refrigerant gases to leak  Until the vessel is opened up in a factory environment, it is very hard to determine the ex act cause of the internal leak FSP’s expert (DA) Report 10 November 2016  In furt her discussions with P, he advised that in every case bar one, the leak within the refrigerant pipework is due to fatigue from thermal expansion/cont raction  While the cause appears determined with some surety, it cannot be confirmed without question until the jacket/dimple plate is exposed FSP’s expert (DA) Email 18 July 2016  P opened the outer sheath of the tank and identified the location of the leak  The leak is at a weld join at the junction of a take off pipe from the dimple plat e to the refrigerant return pipe towards the rear of the tank  The leak is consistent with fatigue caused through the expansion and contraction of the metal pipe through the cooling and cleaning p rocess Case No: 460533 Determination Page 5 of 5  The leak identified is not unusual for a tank of this age App’s expert (BS) Report 28 July 2017  The heating and cooling of the milk vat may result in thermal fatigue fracture, normally at the welds  This is quite rare as the welds are checked and tested when the milk vat is manufactured  The technician had pressurised the dimple plate vat and sprayed liquid soap at the point where the fracture was detected  We saw soap bubbles increase in size verifying that there was a gas leak – most likely at the weld App’s repairer Email 15 August 2017  The leak is caused by metal fatigue due to heat and contraction of the stainless steel  Many factors can lead to this happening over the years of usage – but the root cause is metal fatigue

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.