Claim denied for subsidence and garage wall damage attributed to faulty slab footing design, with dispute over air conditioner water leak as cause
Text of the determination
Determination
Case No: 460076 Determination Page 1 of 12
Case number: 460076 15 February 2018
1 Overview
1.1 Dispute
The applicant lodged a claim under his landlord insurance policy held with the
financial services provider (FSP) after cracking and movement damage appeared in
the garage of the insured rented property.
The FSP denied the claim on the basis the damage occ urred as a result of ongoing
soil movement caused by faulty design of slab footings relative to the conditions of
the site.
The applicant disputes the FSP‟s denial of the claim. He says the damage occurred
as a result of a fault in the air conditioning unit which discharged water into a cracked
stormwater pipe.
Both the applicant and the FSP provided expert evidence in support of their
respective positions.
The applicant has since completed the repair work and sold the insured property.
The applicant provided invoices detailing the costs he incurred in completing the
remedial works. The applicant wants reimbursement of repair costs, reimbursement
of expert report costs and cover for loss of rent.
1.2 Issue and key findings
Is the FSP entitled to deny the claim?
The information provided shows subsidence in the soil beneath and adjacent to the
garage wall caused damage.
While it is accepted the edge beam of the footing was not correctly designed or
constructed for the soil profile evident in the area, the FSP has not provided an
explanation of how the subsidence could have occurred so many years after
construction had it not been for excess moisture in the reactive soil.
It is further accepted while the excess water would have caused the soil to lose
bearing capacity, the effect would not have been as significant had it not been for the
faulty design and construction of the slab edge beam.
In these circumstances it is fair the FSP pay the applicant an apportioned amount
(30%) in settlement of the claim for reimbursement of agreed repair costs and agreed
loss of rent.
As the FSP also relied on the applicant‟s expert reports in assessing the claim, the
dispute required consideration of complex engineering issues and the applicant
Case No: 460076 Determination Page 2 of 12
genuinely required expert assistance, it is also fair in the circumstances the FSP
reimburse the applicant the agreed amount of costs for expert reports (up to $3,000).
1.3 Determination
This determination is partly in favour of the applicant.
The FSP is to settle the claim in accordance with section 2.1 of this determination.
Case No: 460076 Determination Page 3 of 12
2 Reasons for determination
2.1 Is the FSP entitled to deny the claim?
Policy provides cover for insured events subject to exclusions
The applicant is required to show, on the balance of probabilities, he has suffered a
loss caused by a risk insured against under the policy. This is known as a prima facie
claim.
If the applicant is able to establish a prima facie claim, then the onus shifts to the
FSP to show, on the balance of probabilities, it is entitled to rely on an exclusion
under the policy or is otherwise entitled to deny the claim.
The applicant‟s policy provides cover for damage caused by the events listed in the
policy terms, including for the insured event of, „water and oil leaks.‟
The event of „water and oil leaks‟ provides cover if damage is caused by water
leaking or escaping from a number of items listed including gutters, drainpipes or
pipes and appliances.
The policy also includes a number of exclusions applicable to the cover, including
exclusions for loss or damage caused by gradual deterioration, subsidence, faulty
design and workmanship.
Damage to the insured property was extensive
The applicant lodged a claim after severe cracking was identified near the front door
and rear garage door of the insured property.
After the claim was lodged, the FSP engaged its assessor (U) to attend the insured
property. UBS advised of extensive damage to the home, including:
slumping of the western garage wall, 20mm away from the door frame
the front veranda beam pulled away
cracking in the brickwork on the eastern side of the brick wall
small stress cracks above the garage door and eastern side door.
U also identified cracks i n the kitchen, living area and bedroom walls and ceilings.
It is not in dispute the property was extensively damaged.
FSP cannot rely on policy exclusion if proximate cause is an insured event
The parties obtained a number of expert reports. The reports agree the damage to
the garage was caused by the subsidence of soil around the damaged area.
The dispute relates to the cause of the subsidence to the area.
As mentioned above, the policy contains a general exclusion for loss or damage
caused by subsidence, unless the damage occurs immediately as a result of an
earthquake or explosion or a storm or flood. There is no suggestion subsidence
damage occurred immediately after one of these occurrences.
Case No: 460076 Determination Page 4 of 12
However, if the proximate cause of the damage (that is, the proximate cause of the
subsidence) was an insured event, the FSP would not be entitled to rely on the policy
exclusion.
Both the applicant and the FSP have identified causes for the identified damage.
Accordingly, for the purpose of applying the terms of the policy, the proximate or
dominant cause of the damage will need to be identified.
Soil at site of insured property is highly reactive
At the time of claim, the applicant had already commissioned the services of two
engineers for the purpose of establishing the cause of damage to the insured
property. He had engaged a geotechnical engineer (CT) and a civil engineer (GA).
CT‟s report provided conclusions in respect of the soil condition of the insured
property.
CT‟s investigations revealed a soil profile of sand, underlain by clay. CT classified the
soil as class H2-D which meant the soil at the site was highly reactive.
In his investigations, CT conducted a footing exposure test, facilitated by digging
boreholes. CT‟s report refers to borehole th ree, which was dug at a depth of 1.5
meters next to the damaged garage wall.
CT found the edge of the slab footing extended 60mm below the ground surface, and
sat on top of a plastic membrane.
In his report, CT provided construction recommendations, in accordance with the
AS2870-2011 building code.
In regard to edge beams, CT advised (according to the code):
“it is recommended that a CLASS H2-D (Refer AS2870 – 2011) slab on ground should be used
at this site with edge beams founded not less than 500mm below the finished surface level
surrounding the structure.
However, the founding dept h must be at least 100mm into any of the naturally occurring soils as
described in the logs of boring which from the site investigation can be assumed to have an
allowable bearing capacity of 80kPa at this depth.”
In regard to slab and or stiffening beams:
“Any organic and delete rious matter should be removed from under the proposed slab area to a
depth of not less than 50mm and replaced where necessary with levelling fill (see 8.1.3 below)
under the slab and internal beams. This excavated surface can be assumed to have an
allowab le bearing pressure of at least 50kPa.”
CT concluded (according to the 2011 code) the footing was founded at a depth less
than the minimum required founding depth recommended at the site.
CT did not provide copies of the relevant code applicable to the claim.
In GA‟s report dated 25 January 2016, GA identified the insured property was
constructed on a wattle raft slab.
CT‟s report provided construction recommendations for a wattle raft slab:
Case No: 460076 Determination Page 5 of 12
“Wattle raft slabs for this site can be designed for CLASS H2 -D following AS2870 and detailed
as per clauses 6.4 (in particular clause 6.4.3) of section 6 of AS2870. For the purposes of
design, the surface of the natural soils at this site as described in the engineering logs will have
an allowable bearing pressure of at least 50kPa. Alternatively, fill placed in accordance with
12.4.2 of this report can be used as a foundation with a beari ng pressure of at least 50kPa.”
It is unclear whether the recommendations for the construction of edge beams
identified by CT, applied to construction of a home on a wattle raft slab.
CT did not make any comment on the design of the wattle raft slab and whether this
was compliant with the relevant code.
Further, CT‟s recommendations were based on a code which was applicable to
dwellings built from the year 2011, whereas the insured building was built several
years earlier.
GA‟s report of 25 January 2016 commented on the design of footings and advised
the design of the footing may be inadequate given the bearing capacity of the soil at
a founding depth of 200 mm is zero. That said, GA‟s report goes on to advise while
the footing was designed for a soil type of M-D (moderately reactive), the footing
depth as designed is 385mm which is adequate for Class H1-D waffle raft footing
with articulated brick veneer construction.
It is unclear whether GA would come to the same conclusion for a soil type of H2 -D.
GA based its conclusion the soil was of H1-D class on its own report on a nearby
allotment, as well as GA‟s own site classificatio ns.
There has been no discussion over why its conclusions differs from CT in regard to
soil class.
In the circumstances, given CT‟s specialisation and evidence of tests carried out to
confirm soil type, I accept the site on the insured property consists of a highly
reactive class H2-D soil.
Edge beam founded at incorrect depth
GA concluded the design of the footing was adequate but the footing was incorrectly
constructed due to the omission of an edge beam of 385mm depth.
This position was later retracted by GA. Following excavation by the contractor
carrying out the rectification works (W), GA said while the edge beam of the waffle
raft footing appeared to be missing, it actually existed about 100mm inside the face
of the outer garage wall.
In a subsequent report, he confirmed the waffle raft footing under the garage wall
was correctly constructed although obscured by a pipe.
It is unclear whether the beam referred to by GA was the same beam referred by CT
as one which was inadequately constructed.
Fur ther, GA‟s report of 22 February 2016 (or subsequent reports) do not comment on
the construction of the beam, in particular the depth at which it was founded.
The FSP had the opportunity to review the information provided by the applicant and
the applican t‟s experts and provide its own report as to the cause of damage by its
Case No: 460076 Determination Page 6 of 12
engineer (JM). JM did not attend the site as repairs had been completed. JM‟s report
is based on the information held by the FSP and provided by engineers in early 2017.
JM commented on the findings of CT in respect of the design and construction of the
property. Having reviewed CT‟s findings, JM advised the garage floor slab edge
beam had not been correctly formed and had been founded well above the stipulated
natural sandy clay soil required for stable support.
JM further advised even though the edge beam had been built, its construction
100mm inside the external face of the garage wall was non-compliant.
In his report, JM relied on the same 2011 guidelines referred to by CT.
In further correspondence with the FSP, JM confirmed the correct guidelines
applicable to the claim and dispute was AS2870-1996.
JM provided a copy of the relevant guidelines which confirm the slab, including any
edge and internal beams, should be founded as follows:
“(i) Slab panels, edge beams, internal beams and load support thickenings are to be
supported on nat ural soil wit h an allowable bearing pressure not less than 50kPa.”
JM advised the edge beam had been founded at a level of 60mm below the ground
surface which had a bearing capacity of 0.
Even if GA‟s position of a founding depth of 375mm is accepted, its Dynamic Cone
Penetrometer Testing for Allowable Bearing Pressure confirms an adequate bearing
capacity of at least 50kPa is only reached at a level of about 700mm below ground
level.
In the circumstances, I accept the edge beam was not founded at the correct depth,
suitable for the soil profile present on the property at the relevant time.
Water affected the area around the garage
The applicant says the dominant cause of subsidence was water which was found to
have discharged on the property.
He says the excess water caused soil around the affected area to subside and
eventually cause the damage.
The assessors who inspected the property made mention of the soft, wet soil.
CT said the area adjacent to the boundary garage wall within the neighbouring
property was found to be abnormally wet at the surface. CT also posited the guttering
may not be functioning correctly, leading to water flows directly to the ground surface.
CT conducted investigation of the moisture content of the soil down to a depth of 1.5
meters and found the moisture levels were normal for the site.
GA‟s report dated 22 February 2016 provided an opinion in regard to the mechanism
by which the damage was caused.
GA consulted with W who advised the top and lower gutter systems were
malfunctioning and causing rainwater to discharge on the adjoining property. GA said
this explained the wet and very soft condition of the sub soil near the garage.
Case No: 460076 Determination Page 7 of 12
GA concluded the main cause of the subsidence of the garage wall and footing was
the wetting and softening of the foundation soil by the excess water, which caused
the soil to lose bearing capacity.
GA further reported during the course of excavation for underpinning, free
groundwater was seeping into the excavations even though there was no recent rain.
Investigations were conducted. A broken subsurface storm water pipe was found
about 4.5m away from the rear corner of the garage. GA said this explained the wet
and soft condition of the foundation soil. The cause of the broken pipe was not known
but GA said it was likely to be due to abnormal accidental loading during the
construction of the house.
While GA then changed his position to conclude the subsidence was caused by the
leaking pipe, GA does not explain how the pipe was leaking, given there was no
recent rain to the area.
At the applicant‟s request, W c onducted further investigations to identify the source of
water leaking from the broken storm water pipe.
W found a drain from the air conditioner was running water at a “constant trickle” into
the gutter and then into the downpipe and storm water system. W explained the float
valve in the air conditioning unit is faulting and so water is continually feeding
through.
Relying on W‟s investigations and findings, the applicant claims the water leak from
the air conditioner caused the damage to the insured property. He says as this is an
insured event, his claim should be paid.
At the FSP‟s request, JM reviewed W‟s findings and past water consumption.
However, JM does not accept this source of leaking water would have been enough
to cause the damage to the garage wall.
JM and UBS advised the leaking pipe was too far from the affected area to cause
damage.
JM also says given the sandy upper soil, the water would have dispersed around the
area of the leak and would not have reached the end of the garage wall.
However a probe test conducted by GA confirmed the moist area extended to a
majority of the western wall of the home, and half way down the affected garage wall.
Testing apparently revealed wet soil to a depth of approximately 900mm.
JM advised this findi ng is not consistent with CT‟s report which found the moisture
content of the underground was normal.
In these circumstances, while GA confirmed wet soil was 900mm deep, there has
been no information provided as to the moisture readings found at that dept h.
The results therefore cannot be compared to CT‟s findings in December 2015.
JM further advised the water consumption readings did not support a conclusion of a
constant leak throughout the property.
Case No: 460076 Determination Page 8 of 12
Review of the water readings confirms consumption decreased after the tenants
vacated in November 2015. However, it increased considerably in March 2016 before
it decreased steadily over the next month.
JM does not provide an explanation for the abnormal water readings during the
period in which the property was vacant.
FSP has not explained why subsidence occurred so long after construction
GA‟s diagram of the moist area shows, while the moisture from the pipe could have
affected the subsidence in the south western corner of the garage wall, most of the
subsidence occurred in the north western corner of the wall, close to the veranda.
There is no indication of abnormal water content in the ground below the area of the
garage.
Because of these factors, JM advised the leaking air conditioning system could not
have contributed to the subsidence of the garage.
If accepted the water did not lead to damage in the affected area, the FSP has not
adequately explained the mechanism which caused the subsidence to the affected
area so long after the house was constructed. (JM noted it was constructed in 2002).
That is, there is no explanation of how the inadequate construction of the garage wall
caused subsidence to occur in 2015.
Fair in the circumstances the FSP pay 30% of the agreed cost of repairs
In these circumstances, I accept it is likely some other factor is at play at the time of
the claimed damage such as water causing the bearing capacity of the soil to lessen.
JM recognised excessive moisture would have likely substantially diminished the
bearing capacity of the soil.
However, I also accept the effects seen from the reduction of bearing capacity would
not have been as significant if the edge beam of the slab was constructed to the
correct standard for the soil type on the property.
In these circumstances, based on the available material, I am satisfied it is fair in the
circumstances the FSP make some contribution to the cost of repairs. Taking all
matters into account, I am satisfied a fair contribution is 30%.
While the applicant has provided some invoices to FOS, he has not articulated the
exact amount of the cost of repairs. If the applicant accepts this determination, then
within seven days of acceptance, he is to provide all relevant proof about the cost of
repairs to the FSP.
Within a further seven days, the FSP is to assess the cost of repairs pursuant to the
policy terms. Once the parties agree on the cost of repairs, the FSP is to forthwith
pay to the applicant 30% of the agreed cost of repairs.
Case No: 460076 Determination Page 9 of 12
Fair in the circumstances the FSP pay 30% of the agreed loss of rent claim
The applicant claims loss of rent. He says while the works were undertaken the
property was not safe to occupy. He says the property was vacant from 28 November
2015 until 18 May 2016.
The FSP‟s policy provides for los s of rent during repairs if a listed event causes
damage to the property and the FSP agrees tenants cannot live in the property. The
FSP will pay lost rent for the time it agrees it is reasonable for repairs to be
undertaken. A condition of this policy benefit is that a rental agreement must be in
place.
The applicant has provided no lease agreement or any substantiating information
about loss of rent. The relevant policy schedule shows the property was rented at
$250 per week. Further, no material is pro vided about the reasonable time it would
take to repair the property.
The available material shows no consideration by the FSP of this aspect of the
applicant‟s claim.
Providing the policy terms can be met, I am satisfied it is fair in the circumstances the
FSP pay to the applicant 30% of this agreed policy benefit.
FOS encourages the parties to reach agreement. However, if the parties are unable
to reach agreement, they can return to FOS for a decision about loss of rent.
FSP is to reimburse the applicant for the cost of the expert reports
The applicant also claims reimbursement for the cost of expert reports.
Pursuant to its Terms of Reference, FOS may decide an FSP contribute to the
professional costs incurred by an applicant in the course of a dispute. Unless
exceptional circumstances apply, FOS will not require the FSP to contribute more
than $3,000 to these costs.
FOS decides whether the FSP should make such a contribution by considering what
is fair in the circumstances. FOS takes into account the complexity of the dispute and
whether the applicant incurred costs because the applicant genuinely required expert
assistance.
I am satisfied it is fair in the circumstances the FSP reimburse the applicant for the
cost of expert reports relied on by the applicant. This is because the FSP also relied
on these reports in assessing the claim, the dispute required consideration of
complex engineering issues and the applicant genuinely required expert assistance.
While the applicant has provided some invoices to FOS, he has not articulated the
exact amount of the cost of expert reports. If the applicant accepts this determination,
then within seven days of acceptance, he is to provide all relevant proof of the cost of
his expert reports to the FSP.
Upon review of the proof of these expenses, the FSP is to forthwith reimburse the
applicant for the cost of expert reports up to $3,000.
Case No: 460076 Determination Page 10 of 12
The FSP is also to pay statutory interest on amounts paid
The FSP is to pay interest on the agreed amount for expert reports, in accordance
with the statutory rate, from the date the applicant paid for the expert reports until the
date payment is made.
The FSP is also to pay interest on the agreed cost of repairs and the agreed loss of
rent from 24 February 2017 (being the date of the FSP‟s final response on liability)
until the date payment is made.
Case No: 460076 Determination Page 11 of 12
3 Supporting information
3.1 FOS Approach
As advised to the parties, FOS has considered it appropriate to expedite this dispute
in accordance with the Operational Guidelines to the FOS Terms of Reference, due
to the nature of the dispute. Accordingly, this dispute has not been the subject of a
FOS recommendation and has proceeded directly to determination.
There has been a full exchange of all material information relied on for the purposes
of this determination and each party has had the opportunity to address any issues
raised by the other. All of the material provided by the parties has been reviewed and
considered for the purposes of this determination.
This dispute has been decided on its merits, having regard to the relevant law, good
industry practice, codes of practice and previous FOS decisions.
While the parties have raised numerous issues in their submissions, for the purposes
of this determination, commentary has been restricted to those issues considered
directly relevant to the outcome only.
It is an accepted principle of general insurance law an insured bears the onus to
establish on the balance of probabilities they have suffered a loss caused by an
event to which the policy responds. This is known as a prima facie claim. Once so
established, the onus shifts to the insurer to prove on the balance of probabilities an
exclusion applies if it seeks to deny or limit its liability for the loss.
3.2 Policy terms
The relevant policy extracts are referred to in the correspondence between the
parties and in the FSP‟s Noti ce of Response dated 24 February 2017. Both the policy
document and the Notice have been exchanged with the applicant.
Record Key points
What you are covered for Water and oil leaks
If loss or damage is caused by water or oil leaking or escaping from
an items shown here.
Covered
water leaking or escaping from:
o house gutters, drainpipes or pipes
o sanitary fixtures – for example, baths or toilets
o appliances – for example, washing machi nes or
dishwashers
o waterbeds
o aquariums
o water tanks
o swimming pools
oil leaking from a fixed heating system or sealed portable heater
Case No: 460076 Determination Page 12 of 12
costs to locate the cause of damage (if we agree to pay these
costs before you make any arrangements).
Not covered
water leaking or escaping from a shower recess or shower base
costs to repair or replace the item that the water or oil leaked or
escaped from
loss or damage caus ed by storm surge.
Exclusions for all cover These exclusions apply to all cover under your policy.
What we don’t cover
Loss, damage, injury or death arising from:
gradual deterioration, depreciation, wear or tear
subsidence or landslide unless it happens immediately as a result
of:
o an earthquake or explosion
o a storm or flood.
mechanic al, structural or electrical failure of an item.
The settling, shrinkage or expansion in buildings, foundations,
walls or pavements.
Maintaining and occupying your rental property
We don‟t cover loss, damage, injur y or death arising from:
Faulty design or workmanship.
3.3 Other relevant material considered and relied on
Parties‟ submissions, emails, photographs, video, expert reports, invoices,
estimates, plans, diagrams, bank statements and all attachments to all
submissions