Text of the determination
Determination
Case No: 458339 Determination Page 1 of 10
Case number: 458339 4 October 2017
1 Overview
1.1 Dispute
The applicants lodged a claim under their Home Insurance Policy with the financial
services provider (FSP), on 10 May 2016, following water damage sustained at their
home as a result of a storm, on 1 November 2015.
The FSP denied the claim on the basis that it was not caused by a storm created
opening and determined the damage was not subject to cover.
The applicants rejected the FSP‟s d ecision and maintain the water was entering from
the roof, where it had been damaged by a previous storm. The applicants raised
reliance on section 46 of the Insurance Contracts Act 1984 (the Act) on the basis that
they were not aware of the structural defects in their home.
1.2 Issues and key findings
Is the FSP liable for damage to the property?
The available information establishes that the damage to the applicants‟ property was
not caused by a storm created entry of water, but by factors which are excluded from
cover under the policy.
Is the FSP entitled to deny the applicants’ claim?
The FSP is entitled to deny the applicants‟ claim because the information provided by
all parties establishes that the damage occurred due to structural defect, or faulty
design, or faulty workmanship and excluded under the policy.
1.3 Determination
The determination is in favour of the FSP.
The FSP is not required to take any further action.
Case No: 458339 Determination Page 2 of 10
2 Reasons for determination
2.1 Is the FSP liable for the damage to the property?
Policy provides cover for insured events subject to exclusions
The applicants are required to show that, on the balance of probabilities, they have
suffered a loss caused by a risk insured under the policy. This is known as a prima
facie claim.
If the applicants are able to establish a valid claim, then the onus shifts to the FSP to
show that, on the balance of probabilities, it is entitled to rely on an exclusion under
the policy or is otherwise entitled to deny the claim.
The applicants‟ policy provides cover for da mage caused by the events listed in the
policy (including the insured event of storm), subject to the exclusions and conditions
set out in the policy.
The policy contains general exclusions for damage caused by:
„(i) water entering through any opening not made by the storm, except water
entering from the overflowing of a road drain, street gutter or other drainage
system external to the premises;
(ii) water or wind entering the home building as a result of structural defects, faulty
design, faulty workmansh ip or lack of proper maintenance to the home building.‟
In this matter the applicants must prove on the balance of probabilities that the loss
was caused by an insured event.
Parties disagree about cause of damage
The reports prepared by the various contra ctors appointed to inspect the applicants‟
premises confirm that there has been entry of water into the premises, and damage
sustained as a result of that entry.
The applicants say that all of the damage has occurred as a result of storm that
became apparent on 1 November 2015. The applicants maintain that prior to that
date, there was damage to the property by a storm which had allowed the entry of
water and caused damage to the internal wall which was not apparent until it had
been opened up. At that time it was discovered that the water damage was visible all
the way to the roof line.
The FSP disputes that the damage was caused by storm, and maintains that there
was no defined event that had occurred but that the damage to the roof was due to
an existing maintenance issue.
Balcony damage did not cause water damage to the property
The FSP used the flood test report from its expert (M) and builder (AJ) to state that
the damage to the lower level of the home was caused by failure of the water proof
membrane on the tiled balcony.
Case No: 458339 Determination Page 3 of 10
The applicants‟ waterproofing expert (WF) supports AJ‟s findings that the attachment
of the balcony balustrades may have punctured the existing waterproofing
membrane.
The applicants do not dispute this but still maintain that the cause of the water
damage is due to the storm event.
The FSP says that its position is supported by the location of the balcony which is
directly above the area of damage to the framework, above the lower window and
hardwood flooring.
WB, the applicants‟ buil der, conducted tests on the balcony with the screw holes
sealed and noted water still came into the balcony from the glass sliding door which
leads from the balcony into the main bedroom. It was noted that it needed a lot of
water sitting on this area before water penetration occurred. WB further questioned
the FSP‟s findings showing that the outdoor entertainment area which sits on the
balcony has never shown signs of water leakage, which would be expected if the
water membrane protection had been breached. He also noted that there was no
water damage to the ceiling which would have been expected if the water had come
through the membrane on the balcony.
It is unlikely that the water entry into the property came through the water proofing
membrane on the balcony.
Likely entry point of water was the opening in the roof
AJ carried out inspection of the applicants‟ roof which was after the completion of
repairs by the applicants‟ roofer (GC).
AJ stated:
“ water ingress was caused by deterioration of box gutter joints, flashings and
roof penetrations
the water entry would have been in the area where silicon seals had
deteriorated, which was maintenance issue and not a storm created opening. ”
GC reported that the ceiling in various areas of the roof had deteriorated, but also
reported the flashings at the rear of the property had become detached due to
insufficient fasteners and „severe weather conditions‟. He was of the opinion that the
flashings loosened by the weather conditions were responsible for the water leaking
into the downstairs lounge area.
The FSP‟s roofer (MR) noted new sealant, however this was as a result of GC‟s
repairs following the storm event. MR was unable to conclude the exact point of entry
and stated there were many possible contributing factors which could only be
determined through a water leak detection test.
The applicants‟ builder WB has also indicated that the roof above the area that
suffered storm damage was the point of entry of water.
WF noted the damaged area may have been caused by roof flashings which could
have come unbonded due to movement or directional rain penetrating through the
cracks in the plaster.
Case No: 458339 Determination Page 4 of 10
Damage was caused by gradual deterioration over a period of time
The applicants do not argue that the storm damage that caused the opening in the
roof occurred on 1 November 2015. The applicants believe that the storm entry
occurred at a previous unknown date and that the damage to the internal wall was
caused over time by water entry through that opening.
WB believed that the decay to the timber frame near the walls was caused by water
getting in underneath the sliding door upstairs, and that the damage had occurred
over a period of time and caused the house framing to decay and move. WB
concluded the applicants would have been unaware of the ongoing leaking.
The applicants‟ carpenter NW noted that movement damage was due to water
damaging the load bearing walls, and NW did no t believe the cause of the wood rot
was due to a failure of the waterproof membrane on the balcony.
NW, the applicants‟ carpenter, provided a report indicating that the water damage
appeared to be coming from the parapet. He confirmed that the movement to the
property is from wood rot to load bearing walls caused from water entering the
parapet area.
The reports indicate that the damage was caused by a leaking roof over a period of
time. The policy excludes „ water… entering the home building as a result of structural
defects, faulty design, faulty workmanship or lack of proper maintenance to the home
building.’ The applicants need to show that the original opening was caused by a
storm.
The damage was not caused by a storm created opening
The reports all indicate that the damage to the property occurred gradually and there
appears to be no doubt that the roof was leaking prior to the storm.
I am not satisfied that the damage was caused by a storm event as set out in the
policy but rather by structural defects, faulty design, faulty workmanship or lack of
proper maintenance to the property. I do note that the applicants indicated that they
were maintaining the property and therefore carrying out proper maintenance. Whilst
I accept that the applicants were carrying out maintenance on the roof, I am not
satisfied that a storm event caused the entry of water into the premises and resultant
damage.
The FSP is not liable to indemnify the applicants.
Section 46 of the Act
The applicants have submitted that section 46 of the Act assists them in this matter.
They argue a reasonable person could not have been expected to be aware of any
alleged defect or imperfections in the main roof as there had been no previous
occurrence of water entry. Section 46 of the Act does not allow the insurer to rely
upon an exclusion which relates to the condition of something before the contract
was entered into, if it was reasonable for the insured not to be aware of the condition.
In this case, the applicants argue that the condition of the roof was unknown to them
and therefore they should not have been excluded.
Case No: 458339 Determination Page 5 of 10
The FSP is not relying upon the condition of the roof but instead is relying upon the
argument that the entry of water into the premises was not as the result of storm and
that even though it has accepted that the water had been entering the property for
some time, it was not a storm event which created the initial entry.
I do not consider that section 46 of the Act applies to the applicants‟ claim.
Case No: 458339 Determination Page 6 of 10
3 Supporting information
3.1 Relevant policy provisions
15.2 Defined Events
If your Certificate of Ins urance indic ates that you have taken out insurance under Section 15,
we insure you against loss, destruction, or damage occurring to the Home Building or Contents
by one or more of the Defined Events listed below during the Period of Insurance except as
stated under We Will Not Pay .
(4) Storm or Rainwater
We will not pay :
(a) more than $1,000 for loss, destruction, or damage to Contents while in the Open Air;
(b) for loss, destruction, or damage caused by:
i. water entering through any opening not made by the storm, except water entering
from the overflowing of a road drain, street gutter, or other drainage system
external to the Premises;
ii. water or wind entering the Home Buildi ng as a res ult of structural defects, faulty
design, faulty workmans hip, or lack of proper maintenance to the Home Building;
iii. water or wind entering the Home Building through an open window or door;
iv. action of the sea or high water;
v. erosion, landslide, subsidence, or any earth movement; or
(c) for loss, destruction, or damage to glasshouses.
17 - General Conditions
The General Conditions set out below apply to all the Sections of this policy. You must comply
with all these General Conditions otherwise we may be entitled to refuse to pay a claim, or to
reduce the amount you are entitled to receive.
(3) Reasonable Care
You must at all times take reasonable care:
…
(a) to maintain the Premises, structures, fittings, fixtures, furnishings, appliances, machinery,
implements, plant, and Property in sound condition;
3.2 Supportive documentation
Record Key points
Applicant’s expert (GC)
Roof repair report
12 May 2016
An inspection of the roof revealed numerous areas where roofing,
flashing and box gutter joints sealant had deteriorated and broken
down over time.
A number of roof penetrations throughout the roof were also showing
signs of sealant deterioration and failure.
We have removed old sealant and re - applied new sealant to all
flashing, penetrations and box gutter joints on all roofs.
At the rear of the property flashing had become detac hed due to
insufficient fasteners and severe weat her conditions.
We have re - secured loose flashing at rear of hous e which was
causing the leaking into downstairs lounge area.
Applicant’s expert (MR)
Roof report
13 May 2016
„On attendance we were advised that there was water entry onto a
cornice/bulkhead near a window in the downstairs rear of home.
This area had complete water damage and has rotted through‟.
„On inspection of the roof area above this water damage, it was
evident that there has been recent silicone applied liberally to all
corners of flashings and box guttering. Without seeing the roof
prior to these repairs, it is difficult to determine if thes e were the
cause and leaking areas‟.
Case No: 458339 Determination Page 7 of 10
We did observe that there was a verandah above the affected area,
this verandah also recently appears to have silicone applied
liberally in areas around tiles and grouting. It would be
recommended to further investigate this area.
The insured made a point of showing us upstairs in the master
bedroom, where we saw a crack in the wall and the insured
mentioned that the sliding door leading to the verandah, above the
affected area, does not close properly. This too might be related to
the affected area.
An exact point of water entry could not be found, as there were many
possible contributing factors and possible points of entry. Without a
thorough wat er leak detection test, it is impossible to pin point the
exact place of water entry and c ause. We would recommend to
have a roofer and builder onsite to work together to further
investigate these issues with a water leak detection test.
FSP’s expert (M)
Flood test report
16 May 2016
On the veranda we installed materials so as to form a dam an d this
was filled with approximately 25mm of wat er which in cause started
to leak and water entered the ground floor family room above the
fixed panel window on the nort hern wall.
We then performed a second flood test, isolating the test area to the
point in which the handrail post was attached to the tiles on the far
right side of veranda when looking out. This is also the area that
the water damage appears on the inside of the property and upon
the second test water entered the property in the same area.
„After completing the flood tests, it is evident that water is entering the
property at the point where the handrail post is connected to the
veranda floor on the far right side looking out‟.
„The cause is likely to be damage to the waterproofing membrane due
to the installation of the handrail‟.
„…to pin - point the exact cause would require removal of the tiles and
bedding for further examination.‟
FSP’s expert (AJ)
Builder‟s report
19 May 2016
The damages to the lower level of the dwelling have been caus ed by
a breach of failure of the waterproofing membrane on the tiled
balcony.
The tiled balcony is directly above where the severe damage has
been sustained to the framework above the lower window and the
hardwood flooring.
We engaged a specialist to flood test the balcony and the water
poured in above the window downstairs which is consistent with
the damage.
It was found the handrail has been directly screwed through the tiled
balcony and into the waterproofing membrane which has created a
breach in the w aterproofing membrane for the wat er to enter the
dwelling.
No fixings should penetrate the waterproofing membrane on a tiled
balcony and this has been the caus e of the server damage to the
downstairs area of the dwelling. This is very poor building practic e
and not to Australian standards.
The downstairs damages have been caused by the failure of
waterproofing membrane and as evident by the severity of the
Case No: 458339 Determination Page 8 of 10
damage have been occurring over a long period of time.
Re: Upstairs damages:
The insured engaged her o wn roofer who provided her with a roof
report and completed some repairs on the trim deck profile metal
roof.
The roofer's report states that there was numerous areas on the roof
where box gutter joints, flashings and roof penetrations had
silicone seals which had deteriorat ed over time.
All these areas where the silicone seals had deteriorated would have
been th e cause of the water entry.
There was no storm created openings on the roof, this is a
maintenance issue.
The upstairs damages have been caused by water ent ering the roof
cavity due to det eriorated silicone seals in box gutters etc. This is
a wear and tea r issue and should not occur on a property of this
age.
Applicant’s expert (WF)
Waterproofing report
20 June 2016
Our main concerns were the attachment of the balcony balustrades
which may have punctured the existing membrane and the
aluminium joine ry around the doors that seemed to have moved
after construction.
The results were that aft er re - sealing the balustrade poles, along wit h
both sets of aluminium framing along the base the balcony is water
tight and is allowing no moisture to travel below.
…it seems the house has suffered some movement whic h is evident
by internal and external cracking.
The leaking issue seems related to this movement which may have
been caused by storms or other major weather events.
The damaged areas would indic ate the problem seems to be coming
from higher up, perhaps the roof flashing has come un - bonded due
to movement or directional rain is penetrating through cracks in the
plaster.
Applicant’s expert (WB)
report
20 June 2016
Recent repairs done to the roof abo ve this area [damaged area]
which was caused by storm damage indicated that this was the
point of entry of water.
The owners were told that water tests that were done on the upstairs
balcony [requested by the FSP] indicated that the water proof
membrane ha d been compromised by a balustrade that had been
screwed into the tiles attached.
I removed the screws holding the balustrade posts to the tiled deck
and filled these screw holes up with Sikaflex then re - attached and
sealed around the post base only to sti ll have water coming in. I
found that the area the water was coming in was under the glass
sliding door which leads from the balcony into the main bedroom
but this area needed a lot of water sitting on that area before wat er
penetrated through.
I found lar ge cracks to the window sill facing out to the river in the
main bedroom which sits above the lounge room below. When I
applied water to thes e cracks water came in through the top of the
bi fold doors in the lounge area. I have repaired this area to stop
a ny further damage to this area.
Case No: 458339 Determination Page 9 of 10
Since my work and inspection the owners have had the balcony area
water proofed and fully sealed off by [„W‟] water proofing. A fully
licensed and professional water proofing company.
The outdoor ent ertainment area which sit s underneath the upstairs
balcony has never showed signs of wat er leak age and has no
water damage to the ceiling which would indicate if the water was
coming through the protecting water membrane in the balcony
above then there would be some sort of water damage to the
outdoor entertainment ceiling area.
There is a lot of water damage in the internal wall from the ceiling
upstairs to the downstairs lounge room which in my professional
opinion over a period of time this has caused the house framing to
decay and move substantially.
I believe that the possible cause for the water to be getting in
underneat h the sliding door upstairs and the cracks to the framing
around the window upstairs is because of the decay of timber
framing behind thes e walls.
The damage to the internal framing was only apparent to the owners
after I removed part of the architrave around the doors below. I
discovered that all the timber frame behind the architrave had
rotted.
The owners would not have been aware of any ongoing leaking that
may have been occurring through damage to the roof or areas
underneat h the sliding door upstairs.
Applicant’s expert (NW)
Report
4 August 2016
During the inspection of the damaged walls I had to remove internal
plasterboard as to allow a proper assessmen t to determine the full
extent of the damage.
My findings from this inspection surprised me as previous reports
done on the property shows that the movement is from normal
ground movement. This isn't an accurat e assessment of the
property as the movement i s directly from wat er damaged load
bearing walls.
The bottom plate on ground floor has severe wood rot caused by an
excessive amount of water damage, causing the load bearing wall
to crush into wood rot timber.
I removed plasterboard to upper level bedroom (directly above
damaged area). In previous report it was said wat er damage has
been caused from balcony (due to normal ground movement), this
may have caused more damage in bad weather but in my opinion
is not the cause of the wood rot, which from this wo od rot
movement has then compromis ed the balcony.
To back up my report you will see in photos that the water damage
runs up the wall above the balcony level and appears to be coming
from the parapet. Therefore movement is from wood rot to load
bearing wal l caused from water entering from parapet area.
Applicant’s expert (NC)
Building designer Report
11 Jan 2017
The proposed upper floor Master Bedroom balcony at the rear of the
proposed extension had been designed with a roof over.
The balcony floor was to have a tiled finish & as such the not ations of
the architectural plans state a flexible waterproofing membrane to
be applied.
Case No: 458339 Determination Page 10 of 10
The selected waterproof membrane application was to be carried out
by a licensed waterproofing applicat o r and Form 16 certificate
supplied in accordance with Building Code legislation.
It appears from the Building Certifiers records that the Form 16
waterproofing certificat e was supplied which covered the balcony
floor.
The Frame & Final inspections had als o been carried out as required.
Copies of the relevant certificat es in regards to the Building Permit
application are enclosed with this letter.