Dispute over amounts paid after storm repairs, wrongful removal of air-conditioning unit and delayed handling

FirmFinancial Firm (Unknown - Insurer)
Decided2018-01-22
ProductGeneral Insurance · Strata
OutcomeFor the complainant in part
Amount awarded$1,000
Non-financial loss$1,500
Amount claimed$14,110
SourceAFCA PDF

Summary

After storm repairs, the insurer's appointed repairer wrongly removed a working air-conditioning unit and left a roof hole that caused further damage. AFCA found the insurer had fairly indemnified the applicant through an upgraded replacement and rejected the further claimed amounts, but ordered $1,000 project management costs and $1,500 non-financial loss for delay and complaint handling.

The applicant was fairly indemnified by the upgraded replacement unit and did not prove the insulation loss, but the insurer's delay and poor complaint handling caused compensable inconvenience and out-of-pocket project management costs.

Issues

Subjects and remedies

pay compensationpay non financial loss

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 453211 Determination Page 1 of 10 Case number: 453211 5 January 2018 1 Overview 1.1 Dispute The applicant holds a Strata Insurance Policy with the financial services provider (FSP). A claim was lodged under the policy for storm damage. The FSP accepted the claim and arranged for the damage to be rectified by its appointed repairer. After the repairs were completed, further damage occurred when water entered the roof space through a hole left by the FSP’s repairer, who had removed a non- damaged air-conditioning unit in error. The applicant subsequently lodged two complaints with the FSP’s Head of Compliance and a Heads of Agreement document requesting payment of $28,975.64 for outstanding repairs, project management fees and pre-approved legal costs. In response, the FSP agreed to pay $4,996 towards some of the repairs. The applicant is not satisfied with the amount paid by the FSP. He is seeking reimbursement of $3,500 for the air conditioner which was removed in error, reimbursement for damaged ceiling insulation, project management fees, a 75% contribution towards rent due to the lack of air-conditioning and compensation. The case manager provided the parties with a recommendation on the issues in dispute. The recommendation was in favour of the FSP. The FSP accepted the recommendation but it was not accepted by the applicant. In the circumstances, the dispute has been referred to me for determination . 1.2 Issues and key findings Is the applicant entitled to the additional amounts claimed? The applicant is not entitled to the additional amounts claimed because, on the material provided, the applicant has not established on the balance of probabilities he has suffered a financial loss as a result of the air-conditioning unit being removed in error. Rather, the material provided establishes the storm damaged unit has been replaced but in addition has been upgraded so that the one replacement air conditioning system now air conditions the entire premises in place of the two previous units. On the material provided, the applicant has not established on the balance of probabilities there was ceiling insulation in the insured premises before the storm and it was damaged as a result of water ingress. Case No: 453211 Determination Page 2 of 10 Is the applicant entitled to compensation? The applicant is entitled to non-financial compensation because the material provided establishes there was an unusual amount of time taken to resolve the situation and interference with the a pplicant’s expectation of enjoyment or peace of mind . While the FSP’s policy may not respond to the claim for project management fees, FOS may award compensation for out-of-pocket expenses under the Terms of Reference and the material provided establishes the project management fees incurred by the applicant were caused by the FSP’s conduct. The applicant has not sustained loss of rent as a result of the FSP’s conduct. 1.3 Determination The determination is partly in favour of the applicant. The FSP is not liable for the additional amounts claimed by the applicant for the removal of the air conditioning unit and for the ceiling insulation. Should the applicant accept this determination, then within seven days of acceptance, the FSP is to pay $2,500 compensation to the applicant. Otherwise, the FSP is not obliged to take any further action in relation to the claim or the dispute. Case No: 453211 Determination Page 3 of 10 2 Reasons for decision I have decided this case on its merits, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all the material submitted by the parties, both before and after the recommendation. I am satisfied the documentation I have relied on has been provided to both parties. While the parties have raised numerous issues in their submissions, for the purposes of this determination, commentary has been restricted to those issues considered directly relevant to the outcome only. Submissions after recommendations After the recommendation was rejected, the applicant made a further lengthy submission in which he essentially reiterated his position. He provided material most which had been provided in the course of the dispute. Where relevant, the post recommendation material from the FSP and from the applicant will be referred to in the determination. 2.1 Is the applicant entitled to the additional amounts claimed ? No financial loss because of the removal of the Attic unit The applicant claims the FSP should indemnify him in the amount of $3,500 for wrongful removal of the Attic air conditioner unit by its agent (DA) as it was still in working order and did not need to be replaced. Before the storm damage claim, the applicant says there were two air-conditioning units on the roof. He says there was a 12.5kw unit (which was damaged by storm) and the 7.5kw Attic unit wrongfully removed by DA. He argues prior to the storm he had a total of 20kws whereas the replacement unit is only 12.5kw. Therefore, he says he has lost 7.5kws from the insured units which existed before the storm. He wants reimbursement so he can be in the position he was before the storm. The FSP agrees DA removed the Attic unit by mistake and without its authority. But the FSP submits the applicant has been fully compensated for his loss. It argues this is because it paid the applicant all claimed costs to install a new air-conditioner which services all parts of the insured premises. Therefore, it says the applicant’s premises have been returned to its pre -loss condition. It argues the applicant has suffered no loss as he has air-conditioning to all areas of the premises as he did prior to the loss. While it remains in dispute whether the Attic unit was working or not, the FSP says the applicant has been compensated as if it was working. DA says the tenant told him the system was not operational. Case No: 453211 Determination Page 4 of 10 The new air- conditioner was replaced by CO. CO’s service report to the tenant dated 21 July 2016 refers to service of the Attic units. The service report notes it tested units for correct operation and all units were operating correctly. CO’s quote to rep lace the air-conditioner notes it is a 12.5kw reverse cycle split ducted air-conditioning unit. CO confirmed in a letter the unit removed was 12.5kw and replaced with the same size unit 12.5kw. However, its final invoice indicates the unit removed was 10kw. This is supported by the certificate of electrical safety which refers to the removal of an old 10kw split system from the roof. The compliance certificate from VBA has the same information. In a letter to the applicant, CO refers to the Attic unit it serviced and estimated to be 7-9kw. It suggested its value was $3,500 ex GST. The applicant also provided information from AE who (presumably) supplied the Attic unit. AE confirmed it was the Attic unit had a 7.5kw capacity. AE said one bigger unit on the roof would not cater for the internal environment as the internal environment requires zoning. It says offices will have adverse temperature fluctuations with one unit no matter what capacity is selected. However, correspondence from CO indicates for an extra cost $951.50 (which was paid by the FSP), air could be connected to all offices and proportional air balance achieved. Further, the applicant agrees in correspondence with the FSP that the new unit has capacity to service all areas of the insured premises. Having considered the material provided, I am satisfied on the balance of probabilities the Attic unit was working. The material from CO about its servicing of the units is more compelling than the suggestion from DA that the tenants told him the unit was not working The applicant’s premises have been returned to pre -loss condition However, I am also satisfied on the material provided the new air-conditioner installed by the applicant and paid for by the FSP provides air-conditioning to all of the p remises. This is because I find the information provided by the FSP’s assessor and CO more compelling than the material from AE who has not recently inspected the premises or is not cognisant of the exact nature of the new unit installed. In the circumsta nces, I am satisfied the applicant’s premises have been returned to the pre-loss condition as all of it will be fully serviced by the new air-conditioner. The applicant argues by supplying just one unit, albeit an upgraded one, the FSP has made a substantial saving on supply and installation of a new unit to replace the unit which was storm damaged but has not reimbursed him for the loss of the unit which was removed by DA. He says the unit is clearly a chattel and covered under the policy. The FSP’s poli cy provides an indemnity to the applicant that it will pay for accidental loss or damage to the building which occurs during the period of insurance. On the information provided I am satisfied the applicant has been fairly indemnified by the FSP in the circumstances of this case. This is because the damaged unit has Case No: 453211 Determination Page 5 of 10 been replaced but in addition has been upgraded so that the one replacement air conditioning system now air conditions the entire premises in place of the two previous units. On the available i nformation, I am satisfied the upgraded replacement air-conditioner has adequately replaced both the storm damaged unit and the unit mistakenly removed by DA. There is no requirement for the applicant to replace the Attic unit as the upgraded replacement air-conditioner will service all of the insured premises. There is no evidence the premises have lost value without two air-conditioning units as the replacement air-conditioner will service all of the insured premises. While the CO suggests the Attic unit had a value of $3,500 there is no evidence to show the Attic unit could have been sold for this amount. Taking all matters into account I am not satisfied the applicant has demonstrated a financial loss because of the removal of the Attic unit in circums tances where the FSP has provided an upgraded air-conditioning system. In the circumstances, the FSP is not required to pay anything further to the applicant. The applicant is not entitled to any reimbursement of premium The applicant also claims he has lost premium paid to the FSP for the insurance of the premises over 15 years. However, the applicant had the benefit of the cover (which covered more than just the removed unit) for the whole period of time. In the circumstances he is not entitled to any reimbursement of premium. The applicant has not established the ceilings were insulated The applicant also claims the ceiling insulation was water damaged because of the hole left in the roof by the FSP’s repairers. He claims $423.36 for material and $472.73 for labour in replacing the ceiling insulation. The FSP does not deny certain damage was caused in this way but has refused to pay this aspect of the claim. It contends the premises had a suspended ceiling and building codes do not allow installation of ceiling insulation in suspended ceilings. The FSP also says an inspection of the premises did not locate any ceiling insulation. The applicant says the entire ceiling to level I is insulated. He contends when the assessor inspected the site with him he did not have access to the ceiling space to check for insulation. He says the fit out of the premises was carried out by a company owned by him. He invited the FSP to attend the site for an inspection and said he would provide a photograph once he had permission from the tenant. After the recommendation, the applicant said he had supplied photographs of the ceiling insulation which the FSP denies. He says (again) he attaches a photograph taken by the plumber who attended to repair roof leaks at the premises. He reiterated the invitation to inspect the ceiling space. I acknowledge the FSP has not provided the relevant building code. I also acknowledge the reports provided by the assessor do not specifically state he inspected the ceiling space. Case No: 453211 Determination Page 6 of 10 However, after the recommendation, the assessor provided an email in which he said he inspected the space above the suspended ceiling in both levels of the insured premises during his reinspection on 28 September 2016. He noted no insulation was in place to either level at the time of inspection. He reiterates the installation of insulation to suspended ceilings is very uncommon. He also says if insulation was installed and if there was water ingress, the installation would hold water causing further damage to the ceiling tiles and perhaps the collapse of the ceiling tiles. The applicant has the burden of proof to establish on the balance of probabilities damage was caused to the ceiling insulation by water ingress. The applicant says the fit out was undertaken by one of his companies yet no material was provided from this persuasive source. Having carefully considered the material, I am not satisfied the applicant has provided sufficient information to prove this aspect of the claim. The sole photograph provided after the recommendation does not identify where or when the photograph was taken. It does not show the insulation was damaged. The certificate of final inspection in 2003 does not establish there was insulation in the ceiling. I acknowledge it is possible if there was ceiling insulation it had been removed at the time it was inspected by the assessor in September 2016. However, if this was the case, I would expect the applicant to make this contention to rebut the assessor’s contentions. Having considered all the available information, I am not satisfied on the balance of probabilities ceiling insulation was damaged as a result of water ingress. The FSP is entitled to deny this aspect of the applicant’s claim. 2.2 Is the applicant entitled to compensation? Compensation for loss may be awarded in some circumstances FOS’s Terms of Reference allow the payment of compensation (capped at $3,000) for non-financial loss. FOS may decide an FSP should compensate an applicant for such loss only where there has been an unusual amount of physical inconvenience, time taken to resolve a situation, or interference with the a pplicant’s expectation of enjoyment or peace of mind. FOS takes a conservative approach to compensation for non-financial loss and expects an applicant to be moderately robust and bear the usual degree of inconvenience when managing an insurance claim. The applicant lodged a complaint as set out in the policy with the FSP’s Head of Compliance on 15 August 2016. The applicant complained there was a delay in payment for approved works and assessment of damage and assumption of responsibility for DA’s conduct. The applicant contends the complaint was made to elevate the claim within the FSP and have it dealt with in a meaningful and prompt fashion. The applicant complains the FSP did not respond within 15 working days as set out in the policy and the industry code. Further, he says the response was provided to the incorrect address. Case No: 453211 Determination Page 7 of 10 The FSP says a heads of agreement document was provided on 29 August 2016 and the FSP responded on 7 September and on 8 September 2016 requesting further information. On 15 September 2016, the FSP’s loss adjustor and the applicant met on site to undertake an inspection. The FSP says the applicant provided new documentation for co nsideration as part of the claim. The FSP says it has a further 15 business days to respond to a complaints once all information is received. It says it has complied with regulatory timeframes. The FSP’s policy provides a dispute resolution process. If an insured has a complaint, an insured can telephone or write to the FSP’s Head of Compliance. If the complaint is not satisfactorily resolved it can be reviewed by the internal dispute resolution committee. The FSP says it will respond to an insured with the committee’s findings within 15 working days. If an insured is not satisfied with the findings of the committee, then an insured may take the dispute to FOS. While there was significant correspondence between the applicant and the FSP’s assessor and the applicant and the FSP’s senior claims consultant after the complaint letters of 15 August 2016, there was no formal response to the complaint letters or acceleration of payment to the applicant. The applicant was invited to formally refer the dispute to the internal dispute resolution committee for further review but did not wish to do this. He wanted to comply with his understanding of the policy document dispute resolution process. At the same time as the complaints letters there were numerous attendances by the FSP’s assessor and a settlement proposal was made on 18 August 2016. The FSP’s assessor also proposed a site meeting to inspect the damage and detail a scope of works. In response the applicant sent the heads of agreement letter dated 29 August 2016. In September 2016, the applicant brought the dispute to FOS. As a result, the FSP referred the dispute to its internal dispute resolution committee . On 15 September 2016, the applicant and the FSP’s assessor met to inspect the damage and to consider a scope of works. The FSP sought clarification of issues in dispute and the FSP’s assessor reinspected the damage. On 29 September 2016, the FSP’s IDR committee met and provided an IDR response. Some aspects of the applicant’s claim were met. Fair the FSP pay the applicant $1,500 compensation I am satisfied the material provided establishes the FSP’s conduct interfered with the applican t’s expectation of enjoyment or peace of mind. While the FSP may have been entitled to further consider material provided by the applicant, the FSP was not clear in its method of handling of the complaint and did not reimburse the applicant promptly for payments made. The assessor’s reports indicates t he assessor was still pressing the FSP for payment of the applicant’s contractor’s invoice in the middle of September 2016. While I accept the FSP was entitled to wait for further material and was entitled to negotiate with the applicant, I consider the FSP should have more proactively Case No: 453211 Determination Page 8 of 10 managed the situation with the applicant once it was aware of the complaints and once it was aware its own contractor had removed the Attic unit which removal caused further water da mage to the insured’s premises. On the material provided, I am satisfied it is fair in all the circumstances the FSP pay to the applicant $1,500 compensation for non-financial loss. Fair the FSP pay to the applicant $1,000 for project management fees The applicant claims $2,460 for project management fees. After the recommendation, the applicant says he spent his time coordinating the works as a builder with 27 years’ experience. He says this is an accepted cost of any project. He says otherwise the FSP would have had to engage a number of subcontractors and paid for their services. The FSP says it will not consider this cost as there is no cover for project management fees for an insured making a claim under the policy. While the FSP’s policy may not respond to the claim, FOS will award compensation for out-of-pocket expenses or other liabilities under the Terms of Reference if it is satisfied that loss is caused by the FSP’s conduct. The FSP’s agent (DA) removed the Attic air -conditioner by mistake. The applicant lost confidence in DA and wanted to have mo re control over the completion of works. In the circumstances, this was not unreasonable. The applicant was therefore required to coordinate and supervise the work necessitated because of DA’s conduct. This work was done by his own contractors (and paid for by the FSP) in October 2016. The work included the craning off of the redundant air-conditioner and the installation of roof sheets. While it appears the redundant air-conditioner was not removed by the applicant, nonetheless, he had made the arrangements to undertake this work. Taking all matters into account, I am satisfied it is fair in all the circumstances the FSP pay to the applicant $1,000 for project management fees. No financial loss sustained as the tenant paid the rent The applicant also claims rent reimbursement of the amount of $7,254.32. He claims 75% of the rent starting from the approval date of works on 28 June 2016 as reimbursement to the tenant for the lack of air conditioning when one unit was storm damaged and the other functioning unit was removed. The applicant says because of the lack of air-conditioning to the front two offices, he was in breach of the lease with his tenant. The FSP says there was no substantiation of a loss of rent claim. It says air- conditioning was available to the tenant throughout the period. After the recommendation, the applicant says he has not stated there was loss of rent but the penalty he was seeking was because of the FSP’s claims handling and the lack of response by the FSP. He says without any penalty there is no reason for the insurance industry to change its ways. Case No: 453211 Determination Page 9 of 10 While the tenants threatened to refuse to pay rent as a result of water leaks, the material provided does not establish the tenants did not pay rent. The applicant acknowledges there is no loss of rent. The applicant must establish he has sustained a financial loss as a result of the FSP’s conduct. Compensation is not payable as a penalty or reprimand. In the circumstances, the FSP is entitled to deny the claim for rent reimbursement . Case No: 453211 Determination Page 10 of 10 3 Supporting information 3.1 FOS Approach It is an accepted principle of general insurance law that an insured bears the onus to establish on the balance of probabilities that they have suffered a loss caused by an event to which the policy responds. This is known as a prima facie claim. Once so established, the onus shifts to the insurer to prove on the balance of probabilities that an exclusion applies if it seeks to deny or limit its liability for the loss. 3.2 Policy wording Di spute Re solution Proce ss “Res olv ing Your Complaints (FSP) are committed to handling any complaints about our products or services efficiently and fairly. If you have a complaint: ...... Cont act us on our dedicated complaints line ….. and/or in writing. (FSP address) If your complaint is not satisfactorily resolved and provided your complaint is eligible to be reviewed by our internal dispute resolution committee you may request that the matter be reviewed by the committee by writing to the person who signed the response letter. ..... We will respond to you with the committee’s findings within 15 working days.” ….. 3.3 Other relevant material considered and relied on  Parties’ submissions, emails , reports, invoices, photographs, and all attachments to all submissions both befo re and after the recommendation.  Correspondence between the parties.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.