Claim declined for inground pool damage under earth movement, hydrostatic pressure and cracking exclusions
Text of the determination
Determination
Case No: 451878 Determination Page 1 of 9
Case number: 451878 22 September 2017
1 Overview
1.1 Dispute
The applicant lodged a claim against the financial services provider (FSP) for
damage to an inground swimming pool after an earthquake on 4 December 2014.
The FSP denied the claim on the grounds that the damage was caused by earth
movement or settlement, hydrostatic pressure or cracking which is excluded from
cover.
The applicant maintains the loss falls within the terms of the policy and in addition
seeks payment for professional legal costs incurred in pursuing his claim.
1.2 Issues and key findings
Does the applicant’s claim fall within the terms of the policy?
The policy provides cover for accidental damage. I am satisfied that the damage to
the pool was accidental damage in that it was sudden, unexpected and unintended.
Has the FSP established the application of an exclusion?
I am not satisfied the FSP has met the onus to establish on the balance of
probabilities the application of a relevant exclusion. I am not satisfied the information
provided is sufficient to establish on the balance of probabilities that the damage was
caused by earth movement or settlement, hydrostatic pressure or cracking.
Is the FSP liable for the ap plicant’s professional and legal costs?
Pursuant to paragraph 9.4 of the Terms of Reference the FSP must contribute up to
$3,000 to the applicant‟s legal costs and up to $3,000 per expert report subject to the
applicant providing relevant invoices if not already provided.
1.3 Determination
This determination is in favour of the applicant.
The FSP is to cash settle the applicant‟s claim for $51,950 plus interest under
Section 57 of the Insurance Contracts Act 1984 (the Act) from 30 June 2016 to date
of payment of the claim.
In addition, the FSP must contribute up to $3,000 to the applicant‟s legal costs and
up to $3,000 per report for the professional costs incurred in obtaining reports from
BM and HR subject to the provision of relevant invoices.
Case No: 451878 Determination Page 2 of 9
2 Reasons for decision
There has been a full exchange of material between the parties and each party has
had the opportunity of addressing the issues that arise in this dispute.
Reference to the applicant in this determination includes reference to submissions
made by the applicant‟s legal representative.
This determination follows consideration of all of the information exchanged and is
based on what is fair in all the circumstances, having regard to the relevant legal
principles, terms of the policy, good industry practice including codes of practice and
prior determinations where applicable.
2.1 Does the applicant’s claim fall within the terms of the policy?
The applicant‟s policy (insofar as it is relevant to the home building) provides cover
against “accidental damage” to the home.
“Accident” is defined under the policy as:
„… a sudden, unexpected and unintended event which:
• You did not intend or expect; and
• a reasonable person in Your position and with Your knowledge and experience
would not have expected.
„Accidental‟ and „Accidentally‟ have corresponding meanings.‟
There is no dispute that the applicant‟s pool has suffered damage and needs to be
replaced.
It is not disputed that the applicant noticed the pool started losing water following an
earthquake on 4 December 2014. Despite attempts to refill the pool, it continued to
lose water.
BM, a registered builder with knowledge and experience in working with inground
pools inspected the pool on behalf of the applicant. BM concluded that the pool had
failed due to a leaking outlet pipe at the base of the pool resulting in hydrostatic
pressure. This caused lateral pressure on the walls and floor resulting in the bowing
of the walls.
CL, a loss assessor for the FSP attended the property on 23 January 2015 and
considered it was feasible that the earthquake had shaken the outlet pipe causing
this to split or separate allowing water to leak from the pool.
I am satisfied the information from BM and CL is sufficient to establish on the balance
of probabilities, a claim for accidental damage to the pool within the terms of the
policy.
2.2 Has the FSP established the application of an exclusion?
The FSP has relied essentially upon the following exclusions as set out in 3.1 to
refuse the claim. Those exclusions broadly deal with:
Earth movement
Case No: 451878 Determination Page 3 of 9
Wear and tear
Hydrostatic pressure
Cracking.
I am not satisfied based on the information exchanged that the FSP has established
the application of one of the exclusions under the policy.
The information does not evidence earth movement being a cause of damage
The available information does not establish earth movement was the proximate
cause of the damage to the pool.
T he FSP‟s engineer FM believes there is evidence of differential movement and
relies amongst other things, upon a 36mm fall of the pool to represent this.
FM did not report on the possibility of the damage being caused by a leaking pipe.
FM admits it did not look at this in its original inspection. It had not been asked to
comment on this. It now states it does not believe it was the cause of the loss.
The applicant obtained a report from BM. BM first saw the pool in December 2015.
BM concluded that the pool had suffered a major structural failure due to a leaking
pipe with resultant hydrostatic pressure causing lateral pressure on the sides of the
pool. He considered it was possible that the pipe could have been shaken lose by the
earthquake.
The FSP‟s loss adjustor CL considered it was feasible that the outlet pipe on the pool
was shaken lose and feasible that this was the cause of damage.
DM, a geotechnical and foundation consultant conducted soil tests. DM concluded
that the founding material beneath the existing pool had adequate bearing capacity to
support the normally expected loads from the pool. DM considered that any
settlement due to consolidation of the fill material was unlikely to have occurred
beneath the pool. Such consolidation would occur during or shortly after construction
and stabilised relatively quickly. DM noted that the entire pool was supported on a
layer of crushed rock which overlies natural gravelly clayey and granitic sand. Whilst
FM disagrees with this the FSP did not conduct any further soil tests.
HR, an engineer, was instructed to determine the most likely cause of the loss of
water and damage to the pool. HR concluded that the damage was consistent with
the broken pipe behind the pool wall. HR noted that the fall measured by FM was
probably built for water runoff and not a result of earth movement.
HR noted that the coping surround around the pool was intact and the surrounding
concrete path had only minor shrinkage cracks. Structurally both the concrete and
the coping was sound and the area showed no signs of excessive ground movement.
HR clarified this last comment to note that there is always a certain amount of minute
earth movement due to environmental reasons. However, these minute movements
did not result in damage to the structure. Photographs supplied support these
findings.
In an email of 16 November 2016, HR noted that HR and FM had inspected the pool
sometime after the event with different instructions. FM had been asked if the
observed damage was directly caused by earthquake. HR‟s brief was to determine
Case No: 451878 Determination Page 4 of 9
the cause of the damage. FM agrees it was instructed to report on whether the pool
was damaged by the earthquake. Neither FM nor HR identified any structural
damage to the structures surrounding the pool which could be expected in the event
of earth movement.
Whilst I acknowledge the differing views expressed by the experts, I am persuaded
by the weight of information presented by the applicant that most likely the damage
did not occur as a result of earth movement.
There is no information to show wear and tear had contributed to this damage
Whilst it is acknowledged that the pool was old, the available information in particular
the report from BM notes that the pool was in good working order prior to the
damage.
Hydrostatic pressure was not the proximate cause of the damage
The FSP has relied upon the exclusion that excludes cover for swimming pools etc.
directly caused by hydrostatic pressure.
Photographs taken by CL shortly after the claim was lodged show there was no crack
at the bottom of the pool at that time. BM has noted that the hydrostatic pool valve
was not faulty and as there were no other leaks from the pool filter, pump etc. the
only thing left that could cause water to leak from the pool was a broken or lose pipe
under the pool.
I accept that hydrostatic pressure contributed to the damage. I do not accept it was
the direct cause of the damage. In my view the proximate cause, that is, the
dominant or effective cause of the damage was the leaking pipe.
The FSP cannot rely upon the exclusion related to cracking
I do not accept the exclusion applies.
The FSP first raised the cracking exclusion in its submission to FOS on
21 September 2016. Whilst I acknowledge the policy excludes cover for cracking, it is
unclear how the exclusion relates to the current dispute. Presumably, the FSP seeks
to apply the exclusion on the basis the pool developed a crack and this was the
proximate cause of the loss and not as a consequence of the loss or damage.
As I have indicated, the proximate cause of the damage was most likely a leaking
pipe. The FSP‟s loss adjustor recommended the replacement of the ent ire fibre glass
shell before the pool shell had cracked. The photographs referred to above confirm
that there was no crack in the pool at that stage. This is also noted in the FSP‟s
report of 9 February 2015.
Leaking pipe was most likely the cause of damage
On balance, the available information establishes the most likely cause of the
damage was either a broken pipe or a pipe that had come lose beneath the ground
due to the tremor.
Case No: 451878 Determination Page 5 of 9
In this regard I accept the views expressed by BM that the damage had been a major
structural failure of the pool due to a leaking pipe and that subsequent hydrostatic
pressure from this pipe caused natural pressure on the sides of the pool. I accept
that this is accidental damage, that is, sudden, unintended and unexpected.
I am satisfied the FSP is liable to meet the applicant ‟ s claim for the damage to the
pool. The most recent quote for the repairs is $51,950. This quote was valid until 30
June 2016. If the FSP is to cash settle this claim then it should pay the applicant
$51,950 for the repairs plus interest from 30 June 2016 to date of payment of the
claim pursuant to section 57 of the Act.
2.3 Is the FSP liable to reimburse the applicant’s professional legal
costs?
Paragraph 9.4 of the Terms of Reference provides that FOS may decide that an FSP
contribute to legal or other professional costs incurred by an applicant in the course
of dispute. Unless exceptional circumstances apply, FOS will not require the FSP to
contribute more than $3,000 to these costs.
It is not usually necessary for either party to be legally represented. Normally where
an applicant chooses to be represented, they are responsible for their own legal fees.
Issues involving particular complexity or which that may reasonably require legal
advice or complex factual situations that require detailed specialist advice may attract
the exercise of the discretion to determine the FSP contribute to such costs.
The current dispute has involved complex issues. Such complexity is demonstrated
in the conflicting expert opinions. The applicant has reasonably sought legal
assistance in putting his submissions. The representative has obtained appropriate
expert reports and provided a clear and thorough submission on behalf of the
applicant. The information has assisted in the forming of this determination.
It is fair in the circumstances that the FSP contribute up to $3,000 to the applicant‟s
legal costs subject to the provision of any relevant invoice.
The applicant paid for the reports obtained from BM and HR. BM provided the initial
report to confirm that the pool had suffered major structural damage. HR provided a
detailed engineering report.
Both reports were reasonably obtained given the complexity of the issues in dispute
and the report provided by the FSP‟s expert FM. This is particularly so when the
FSP‟s expert disagreed with the earlier information provided by the loss adjustor and
BM. The reports have assisted in forming a view as to the resolution of this dispute
It is fair in the circumstances that the FSP contribute up to $3,000 for each report
from subject to the applicant providing relevant invoices.
There was also a detailed report from DM. This is a geotechnical report but I have
not been provided an invoice with respect to this. It is unclear whether any costs
have been incurred in this regard. If the applicant has incurred costs in obtaining the
report from DM, then subject to providing a relevant invoice, I am satisfied that the
FSP should also meet the costs of this report up to the limit of $3,000.
Case No: 451878 Determination Page 6 of 9
Case No: 451878 Determination Page 7 of 9
3 Supporting information
3.1 Relevant expert reports
Record Key points
Loss adjuster report (CL)
9 February 2015
The claim is for damage to an above ground fiberglass pool .
It appeared to have been in good condition and well maintained .
Noting the 3.3 magnitude earthquak e from 4 December 2014, CL
considered it possible this event had shaken the outlet pipe for the
pool, “causing this to split or separate allowing water to leak f rom
the pool” .
Given the extent of damage, the pool will have to be replaced
CL recommended an engineer be appointed to review the damage.
Engineer report (FM )
12 March 2015
Pool noted to be Glass Reinforced Plastic (GRP) pool shell buried
into the ground . FM unsure if separately reinforced .
Large crack through the bas e of the GRP pool lining and the
bottom pool is “bulging” or “bowing” upwards which is hollow and
moves significantly under foot .
Several cracks to the concrete slab surrounding the pool which
have the appearance of shrinking cracks.
Cracks to the plastic cover “filter box” at the south west of the pool
surround .
FM considers the observed damage was not the result of an
earthquake event or “any other definable event” .
The applicant‟s home was outside the “felt radius” for the reported
earthquake on 4 December 2014 .
There was no other damage reported at the site – an eart hquake of
sufficient intensity to cause damage will typically affect “brittle
finishes first” (like glass, windows or maso nry) .
FM considered the damage was the result of a combination of
wear and tear and degradation of the GRP material over 15 years,
together with differential ground movement .
The ground movement was expected to be a combination of
several factors, includin g differential consolidation settlement and
differential soil moisture content.
Geotechnical consultant
report (DM)
14 May 2015
Report into the soil and founding conditions for the pool site
Pool is supported “on a significant layer of crushed rock” which
overlies “natural gravelly, clayey and granitic sand”
The founding material “has adequate bearing capacity to support
the normally expected loads from the pool”
As a result, “differential settlements due to consolidation of fill
material are unlikely to h ave occurred beneat h the pool”.
Builder report (B M )
December 2015
There was a “major structural failure of the pool” due to a leaking
pipe – the pool is not repairable .
Hydrostatic pressure from the leaking pipe caused lateral pressure
on the sides of the pool .
The floor has a “large crack” in it, allowing water to leak in and out .
Case No: 451878 Determination Page 8 of 9
The issue first arose after an earth tremor in December 2014 .
Whilst it was old, the pool appeared to have been in good working
order .
Engineer report (HR)
10 February 2016
Conc urs with BD that the cause of the damage to the pool is a
broken pipe .
The failure could have been the res ult of the earthquake but there
are ot her possible causes .
The concrete surrounds for the pool were in “very good condition”
The fibreglass pool shell would have been in “fairly good condition”
if not for the cracks caused by the leak .
There were no signs of excessive ground movement in the vicinity
of the pool .
HR concluded one of the pipes servicing the pool bec ame
displaced sometime in or around December 2014, causing the
excessive loss of water which ultimately damaged the pool .
This could have been caused by the earthquake or shockwaves
from use of a jackhammer or something similar .
The water leak was the direct cause of the additional damage t o
the pool, including the cracking of the pool floor and buckling of the
sides.
Engineer report (FM)
20 September 2016
After reviewing the additional information supplied on behalf of the
applicant, FM saw no reason to change its view on its view of the
c ause of the loss .
FM‟s original report did not consider the pipe leak as it was not
asked to investigate it. Notwithstanding this, FM did not believe it
was a contributory factor to the loss .
Further, FM considered the reported earthquake would not have
af fected the pipework.
Engineer report (FM)
14 November 2016
FM considers the pool showed signs of wear and tear, that the pool
shell “has degraded, bec ome weaker and become more
susceptible to damage” .
With the 36mm fall of the pool through the grading of the land, FM
considers the installation of the pool would have been to a
tolerance level of 10mm - 20mm, so believes the additional fall is
representative of settlement since this time (16mm - 26mm) .
Engineer report (HM)
16 November 2016
Notes CL identified the pool level was dropping prior to any
identification of a crack at the bottom .
The hydrostatic valve for the pool was not faulty and yet the pool
continued to empty .
The only reasonable explanation is that a pipe had broken or
become loose beneath the g round as a result of an earth tremor .
All other damage to the pool was a direct consequence of this .
HM does not consider the 36mm drop for the pool is representative
of ground movement as this would affect the copping blocks and
concrete path as well.
Case No: 451878 Determination Page 9 of 9
3.2 Relevant Terms of Policy
‘ What You are insured against
This policy insures You against Accidental damage, burglary and theft occurring during the
Period of Insurance.
What is not insured
This policy does not insure You against:
1. damage directly caused by:
…
earth movement no matter how caused, including erosion, vibration, subsidence,
seepage, saturation, creeping, landslip, mudslide, collapse, shrinkage, settling,
expansion or heaving, unless the damage occurs within 72 hours of, and is directly
caused by:
a. earthquake; or
b. water overflowing, leaking or bursting from a fixed pipe etc
…
4. damage to:
swimming pools, spas, septic tanks or other in ground structures, including their
surrounds, directly caused by Hydrostatic Pressure
…
7. Cracking (other than Cracking of a bath tub, shower recess, wash basin, bench top,
sink, toilet bowl, cistern or stove top), chipping (other than the chipping of a bench top
or stove top), splitting, tearing, scratching or denting, unless directly caused by fi re,
lightning, earthquake, Storm, explosion, burglary, theft, vandalism or impact by a
vehicle or aircraft. ‟
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.