Home / Financial Firm (Unknown - Insurer) / Determination 450551
Determination 450551
Cracking damage attributed to 2011 sewerage leak claim denied as ground movement
Summary
Applicant claimed cracking damage to her home, attributing it to a 2011 sewerage leak, and complained of delay in the decision. AFCA found the damage was not caused by an insured event and the likely cause, ground movement, was excluded; the delay was reasonable.
The insured must show on balance that the damage was proximately caused by an insured event, and engineering evidence on settlement pattern and elapsed time did not establish that.
Issues
- Claim denial primary · not upheld
“I am not satisfied the applicant has established that the damage claimed to her home was, on balance, caused by the insured event of escape of liquid.”
- Delay secondary · not upheld
“I do not consider the time taken by the FSP was unreasonable in the circumstances, and so compensation is not warranted.”
Subjects and remedies
home or building damageno remedy
Text of the determination
Determination
Case No: 450551 Determination Page 1 of 6
Case number: 450551 30 October 2017
1 Overview
1.1 Dispute
In May 2015 the applicant lodged a claim under her home and contents insurance
policy held with the financial services provider (FSP). This was for cracking damage
to her home, which she says was due to a sewerage leak in 2011.
The FSP denied the applicant’s claim, saying the damage was caused by ground
movement and not by the leaking pipe.
The applicant disagrees. She says an engineer she engaged was of the opinion the
leaking pipe caused or at least contributed to the foundation movement and cracking
damage.
The applicant is also unhappy with the length of time taken by the FSP to complete
its assessment and make a decision on her claim.
1.2 Issues and key findings
Has the applicant established a valid claim under the policy?
The applicant has not established a valid claim under the policy because she has not
shown, on balance, the damage to her property was caused by an ‘ insured event ’.
Is the FSP entitled to deny the applicant’s claim?
As the available information shows that the damage to the applica nt’s pro perty was
not caused by an event insured under the policy, the FSP is entitled to deny the
claim. Although the FSP does not need to show an exclusion applies (since there
was no insured event in the first place), the evidence indicates the damage was likely
to have been caused by ‘ground movement’, which is excluded under the policy.
Did the FSP unreasonably delay making a decision on the claim?
The FSP did not unnecessarily or unreasonably delay making a decision on the
claim, because it was entitled to conduct further investigations due to the nature of
the issues involved.
1.3 Determination
This determination is in favour of the FSP. The FSP is not required to take any
further action.
Case No: 450551 Determination Page 2 of 6
2 Reasons for determination
I have decided this case on the basis of what I consider fair in all the circumstances,
having regard to the relevant law, good industry practice, codes of practice and
previous FOS decisions.
I have taken into account all the material submitted by the parties. I am satisfied that
the documentation I have relied on has been provided to both parties. For the
purposes of this determination, I will deal with only those points considered relevant.
2.1 Has the applicant established a valid claim under the policy?
Policy provides cover for insured events subject to exclusions
The applicant is required to show that, on the balance of probabilities, she has
suffered a loss caused by a risk insured under the policy. This is known as a valid
(or prima facie ) claim.
If the applicant is able to establish a valid claim, then the onus shifts to the FSP to
show, on balance, that an exclusion applies or that it is otherwise entitled to deny the
claim.
The applicant’s policy provides cover for damage caused by specific listed insured
events (including the insured event of ‘ escape of liquid ’ ), subject to certain conditions
and exclusions.
Parties disagree about cause of damage
The FSP will not be liable for the damage to the applicant’s property if the proximate
cause of the damage (that is, the operative, effective or dominant cause) was not one
of the events insured under the policy.
The applicant noticed problems with her home in March 2015, and so she obtained
quotations from an underpinner. The underpinner suggested that the sewerage pipe
leak under the home in 2011 could have been the cause of the problems
experienced in 2015. The applicant believes the damage to her property was caused
by that 2011 leak. She says that she is not aware of how long the pipe could have
leaked before she discovered it.
However, the FSP disputes that any of the damage was caused by the 2011 event.
It says that the cracking and movement damage in the house was not caused by the
sewerage leak, but by other factors that are not covered under the policy.
Engineers’ reports show cause of damage most likely not from sewerage leak
The FSP relies on a report from its engineer (FM) which states that the damage to
the applicant’s property was not caused b y the 2011 sewerage pipe leak, for the
following reasons:
the soil, expected to be reactive clay, would increase in volume with increase in
moisture and then shrink with drying
Case No: 450551 Determination Page 3 of 6
the founding clay soil has high plasticity with relatively low permeability, so any
water flowing on the surface (such as from a leaking sewerage pipe), may not
penetrate downwards to depths far enough to cause ‘ heave ’ , and it is expected
that the majority of surface water would drain away quickly or locally saturate the
ground within the top layer of soil and evaporate off
clay foundation soils need large volumes of water (for example, a long term leak
of pressurised water mains) to experience ‘ heave ’
the damage is predominately to the north eastern corner of the extension, which
is remote from location of sewerage leak
the pattern of damage observed is settlement (rather than heave, which would be
expected if cause was a leak or escape of water)
the sewerage pipe leak was in 2011 and any moisture would have evaporated in
the intervening time (several years) so it could not be expected to contribute to
the current damage.
The applicant’s engineer (PB), however, found that the sewerage leak from 2011 ,
and the resulting ground saturation and progressive drying out, would have caused
or at least contributed to the foundation movement and resultant cracking to the
brickwork and settlement of the paving slab.
PB disagreed with FM’s conclusion that the water from the 2011 sewerage overflow
would not affect the building foundations, saying it is likely the building footings are
shallow and can be influenced by variations in moisture of the founding clays.
PB’s report however, does not provide sufficient compelling information to establish
that the water from the 2011 overflow was the proximate cause of the more recently
reported damage to the property (even if it may have contributed to some extent).
So I am not satisfied, on the available evidence, that the sewerage overflow in 2011
was the dominant cause of the damage to the applicant’s property.
Applicant has not established a valid claim under the policy
I consider it reasonable to expect that damage from a sewerage leak in 2011 would
occur and be noticed sooner than several years later, given that the leak was
rectified and any residual water would have evaporated or otherwise dispersed in the
meantime.
The available material establishes that the pattern of damage is settlement rather
than heave (which would be expected if water from any such leak affected the
foundation clay soils).
As well, the majority of the damage is in the north eastern corner of the extension,
which is not immediately near the location of the leak. Even though the applicant had
indicated it was closer than FM reported, this is not in itself sufficient to overcome the
difficulties presented by the other factors such as the pattern of damage and time
elapsed since the sewerage leak.
So I am not satisfied the applicant has established that the damage claimed to her
home was, on balance, caused by the insured event of ‘escape of liquid’.
Case No: 450551 Determination Page 4 of 6
2.2 Is the FSP entitled to deny the applicant’s claim?
The FSP is entitled to deny the applicant’s claim because the applicant has not
established that the damage to her property was covered by an event listed under
the policy; and in any case, the likely cause of the damage – ‘ground movement’ –
was excluded under the policy.
2.3 Did the FSP unreasonably delay making a decision on the claim?
The applicant believes that the FSP has unnecessarily delayed providing a decision
on her claim. While acknowledging the time taken to provide its claim decision, the
FSP says that was not unusual considering the complex nature of the claim.
An insurer is entitled to properly investigate any claim it is called upon to meet – as
long as it does so in a fair and reasonable manner and within a reasonable timeframe
(which is likely to depend on the nature of the issues involved). Some delay may
occur, but that does not mean it is unreasonable or unnecessary.
Having reviewed the claim notes provided by the FSP, I can see that the FSP’s
appointed engineer took over two months to provide its findings on the damage to the
applicant’s property. The delay will understandably have caused the applicant some
concern and inconvenience, although I have seen nothing to indicate the impact of
this was more than might reasonably be expected in the course of dealing with a n
incident and claim such as this. In any case, I do not consider the time taken by the
FSP was unreasonable in the circumstances, and so compensation is not warranted.
Case No: 450551 Determination Page 5 of 6
3 Supporting information
3.1 Relevant policy provisions
Section Key points
Escape of liquid
Page 23
We cover
Loss or damage caused by liquid leaking, overflowing or
bursting from any of the following:
…
any drain, fixed pipes, roof gutters or guttering and rainwater
downpipes, drainage and sewage systems; …
General exclusions
Page 50
Ground movement
erosion, vibration, subsidence, landslip, landslide, mudslide,
collapse, shrinkage or any other earth movement, but we will
cover landslide or subsidence that is specifically covered under
the following insured events:
‘Storm’ (s ee page 20);
‘Flood’ (s ee page 19);
‘Eart hquak e and Ts unami’ (s ee page 21);
‘ Explosion (s ee page 25).
3.2 Supporting documents
Section Key points
FSP’s Engineer (FM)
Report 1
18 August 2015
It is the opinion of FM that the observed damage to the house
has been caused by differential footing movement as a result of
one or more of the following contributing factors:
Expected highly reactive underlying soils.
Long term foundation soil moisture content variations due to
one or more of the contributing factors outlined in the report.
Inadequately designed and/or constructed footing systems.
Differential footing systems between the orig inal and
extended parts of the building.
FSP’s Engineer (FM)
Report 2
24 September 2015
Whilst FM accept that the Owner may have had all stages of
the build ‘ signed off ’ by a Building (Council) Inspector, and
that the footings may have been compliant with the
contemporary code, this is not necessarily an indication that
the footings were designed and constructed in a manner
adequate to reducing the amount of differential settlement of
the building, or ensuring that any differential movement of the
footings does not cause damage to the dwelling.
FSP’s Engineer (FM)
Report 3
18 November 2015
FM maintains the opinion that the volume of water escaping
from the reported sewer leak would not have bee n expected
to be sufficient to cause or contribute to the obser ved
Case No: 450551 Determination Page 6 of 6
damage to subject property.
Given the age of the building and the extension, the
foundations are expected to be shallower than would be the
case with a newer built house, and that as a result would be
more susceptible to movements caused by soil moistu re
content variations.
T he following items are not considered to be consistent with
damage caus ed or contributed to by heave caused by a pipe
leak:
o the pattern of floor levels shown by level survey
o t he pattern of cracking observed
o t he remoteness of the ob served cracking from
the r eport ed leak location, which is
approximately 5 - 6m met res away
o t he elapsed time between the repairs
undertaken to the sewer pipe and the
damage being observed and report ed by the
Owner.
Applicant’s Engineer
(PB)
Report
18 August 2015
The situation around 2011 where the ground was saturated
with wat er and subsequently progressively drying out after
the repair to the drainage flow, would have caused or at least
contribut e d to the foundation movement and resultant
cracking to the br ickwork, and also to the settlement of the
paving slab.
The foundation clays would swell with increas e in moisture
content and convers ely shrink upon drying out.
It is likely that the footings for this hous e, considering the age
(40 - 50 years) are normally shallow and can be influenced by
variations in moisture in the founding clays, as with the case
of the overflow of the drainage pipe.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.