Home / Financial Firm (Unknown - Insurer) / Determination 446024

Determination 446024

Escape of liquid claim declined for ground movement and lack of maintenance

FirmFinancial Firm (Unknown - Insurer)
Decided2017-05-15
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant
Amount awarded$3,000
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant claimed under a home policy for damage from leaking pipes, and the FSP declined it as ground movement and lack of maintenance. AFCA found the escape of liquid was the proximate cause, ordered the claim met, and ordered a contribution of up to $3,000 towards the applicant's engineering report.

The FSP did not establish that ground movement, rather than the escape of liquid from broken pipes, was the proximate cause of the damage.

Issues

Subjects and remedies

home or building damagepay claim

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 446024 Determination Page 1 of 5 Case number: 446024 5 May 2017 1 Overview 1.1 Dispute The applicant lodged a claim on his Home and Contents Insurance Policy held with the financial service provider (FSP), in November 2015 after cracks had been noticed in the property. The FSP obtained a leak detection and engineering report and subsequently declined the applicant’s claim on the grounds that the damage was due to long term ground movement and lack of maintenance. The applicant has disputed the FSP’s decision. 1.2 Issues and key findings Has the applicant established a claim under the terms of the policy? The policy provides cover for a number of defined events including the escape of liquid. The panel is satisfied, on the balance of probabilities that movement to the property occurred as a result of escape of liquid. Has the FSP established the application of an exclusion? The policy excludes cover for ground movement and lack of maintenance. The panel is not satisfied that the FSP has established that the proximate cause of the damage to the applicant’s property was ground movement or lack of m aintenance. 1.3 Determination This determination is in favour of the applicant. The FSP is to meet the applicant’s claim in accordance with the terms and conditions of the policy. Case No: 446024 Determination Page 2 of 5 2 Reasons for determination There has been a full exchange of material between the parties and each party has had the opportunity of addressing the issues that arise from the information exchanged. In view of the complexities involved in this dispute it has been referred to a panel for determination. The panel has considered all of the information exchanged and has based this determination on what is fair in all the circumstances, having regard to the relevant legal principles, terms of the policy, good industry practice including codes of practice and prior determinations where applicable. 2.1 Has the applicant established a claim under the terms of the policy ? The applicant has the onus to establish on the balance of probabilities a claim that falls within the terms of the policy. This is commonly called a prima facie claim. Only once the applicant has established a prima facie claim does the onus shift to the FSP to establish the application of an exclusion. Policy is a defined events policy The applicant’s policy is a defined events policy that provides cover for a number o f specified events subject to relevant exclusions. Included in the defined events is cover for the escape of liquid as follows: ‘Escape of liquid We cover Loss or damage to the building caused by liquid leaking, overflowing or bursting from any of the following: …  any drain, fixed pipes, roof gutters or guttering and rainwater downpipes, drainage and sewage systems; …’ Circumstances of the loss According to the applicant, when lodging the claim in November 2015, they had first became aware of slight cracki ng to the concrete outside the back of their home near the back of the wall approximately one year earlier. They informed the FSP that the ground appeared wet. The FSP obtained a leak detection report from A1. The report dated 17 November 2015 identifies three pipes under the ensuite bathroom that had been damaged. Root ingress into the pipes had been noted. The report identified the leaking pipes had Case No: 446024 Determination Page 3 of 5 caused cracking to the external wall at the rear of the house and movement of the concrete pathway on the patio. An internal assessor examined the applicant’s property on 23 November 2015. That report notes that all damage was consistent with the event claimed and identified that an engineer should be appointed to obtain a scope of works. The panel is satisfied based on the reports from the assessor and A1 that the escape of liquid had caused saturation of the soil. The panel is satisfied the applicant has established a prima facie claim under the terms of the policy. The onus is therefore on the FSP if it seeks to rely upon an exclusion to defeat the applicant’s claim. 2.2 Has the FSP established the application of an exclusion? The panel is not satisfied that the FSP has established the application of an exclusion. Whilst the FSP has obtained engineering reports the panel is not persuaded that the reports establish on the balance of probabilities that the proximate cause of the damage was ground movement and not the escape of water. Report from JHA JHA inspected the property on 30 November 2015 for the FSP. JHA considered foundation subsidence occurred in the first instance causing the building movement which resulted in damage to the sewerage pipes. JHA attributed the damage to general subsidence. The panel notes that JHA in its first report relied upon an incorrect assumption that the foundations were on cut and fill. The applicant has provided information that this was not the case. In a supplementary report on 18 January 2016 JHA maintained its opinion and advised that the main evidence used to come to the conclusion that ground movement occurred in the first instance were the floor contours. It considered the contours did not indicate that initial movement was caused by a broken pipe as movement from a pipe leak will form a path based on the flow of water to the lowest point on the lot and that had not occurred. It is not clear exactly how this view was formed given the evidence clearly shows a pipe leak. The panel notes that the report from JHA is not signed, there is no indication as to who conducted the inspection, whether it was an engineer or not. Whilst there is a co-author, the other authors of the report are not identified. The applicant’s engineer suggested the reports were prepared by non-engineers. The FSP has not refuted this suggestion. Applicant’s report from NJA The applicant provided a report from NJA who inspected the property on two occasions. NJA confirmed that the footings were not founded in fill material and considered the consolidation of the fill being a cause for subsidence as suggested by JHA should be ruled out. Case No: 446024 Determination Page 4 of 5 Soil tests indicated the slope of the land from the right corner to the rear left corner as a reverse to that indicated in the JHA report. NJA believed JHA had misrepresented the relevant conditions of the site. NJA considered the damage reflective of what may be expected to occur as a result of abnormal moisture influence (leaking pipe). He found the internal defects concentrated in an area towards the rear of the dwelling between the two bathrooms consistent with the location of the broken pipe and shower tray. The main defect in the garage was located towards the centre of the rear wall which was likely contributed to by a footing rotation due to a loss of soil strength. NJA considered the other abnormal moisture influences such as the presence of trees, area of poor site drainage and gutter leaks but found no correlation between those factors and the damage to the property. NJA considered the leaking pipes had caused loss of soil strength and that the soil at the applicant’s property is the type that can lose strength when water affected. Report from WSP WSP considered the damage was not attributable to a specific event but had occurred over a long period as evidenced by the finding of tree roots withi n the drainage pipes. The panel notes that the applicant identified the damage first occurring at least 12 months before reporting the loss to the FSP. WSP noted the saturation of the soil was having an ongoing effect on the site and possibly resulting in the cracking and damage to other pipes under the slab. WSP considered the cracking and movement observed as pre-existing and that the damage was as a result of general ground movement. WSP concludes that the pipe leak was caused by soil movement due to highly reactive soil. It is generally accepted that highly reactive soil is soil that expands on wetting and shrinks on drying. Soil movement attributable to highly reactive soil is generally due to a change in soil moisture content. Whilst WSP says the soil movement was not caused by a pipe leak, it does not explain what else could have caused the change in soil moisture. WSP has referred to movement to nearby trees and poor site drainage however, the applicant’s engineer NJA has ruled these factors out as they are not correlated with the location of the damage. The soil closest to the trees had not shrunk, the soil in the area with drainage issues had not heaved. WSP does not address this point. Leaking pipes were the proximate cause of the damage If the FSP is to rely upon the exclusions relating to ground movement, it must establish that ground movement was the proximate cause of the damage and not the leaking pipes. The proximate cause of damage is the dominant or effective cause of damage. In the panel’s view the information provided by the FSP is not sufficient to establish the ground movement was not caused by the leaking pipe. Case No: 446024 Determination Page 5 of 5 The FSP has not addressed the findings by NJA that the location of the defects is concentrated in the area consistent with the location of the broken pipes and shower tray separation. WSP considered tree roots within the damaged pipes as evidence that the damage was not attributable to a specific event, but WSP does not explain how the finding of tree roots within a damaged pipe determines whether the pipe damage was caused by earth movement or vice versa. The panel also notes that the applicant informed the FSP on inception of the policy in 2014 that the property had been subjected to flooding in 2012. The FSP has provided no information with respect to that event. There is no information to suggest that any of the damage to the applicant’s property was in any way associated with that event. The panel is persuaded by the report from the applicant’s engineer NJA and is not satisfied the FSP has established the application of a relevant exclusion under the terms of the policy. The panel is satisfied the proximate cause of the damage to the applicant’s proper ty was the escape of liquid from the broken pipes, an insured event that falls within the terms of cover under the policy. Applicant is entitled to cost of engineering report Under paragraph 9.4 of the Terms of Reference , the Service can determine the FSP contribute towards the costs of the expert reports obtained by an applicant for the purpose of assisting in the dispute before the Service. The panel has found the report from NJA most useful and has been persuaded by the report to find in favour of the applicant. In the circumstances the panel is satisfied that the FSP should contribute to the cost of the applicant obtaining the report and should meet the applicant’s claim for costs up to a maximum of $3,000 subject to the applicant providing a relevant invoice.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.