Home / Financial Firm (Unknown - Insurer) / Determination 444369

Determination 444369

Shower water damage claim declined under gradual deterioration exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2017-01-09
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant's claim for shower damage was denied by the insurer as gradual deterioration, wear or tear. AFCA found the exclusion applied and the FSP was entitled to deny liability.

The insurer bore the onus of proving the exclusion, and on balance the expert evidence showed the damage resulted from gradual deterioration excluded by the policy.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 444369 Determination Page 1 of 7 Case number: 444369 9 January 2017 1 Overview 1.1 Dispute The applicant’s claim for damage to his shower was denied by his insurer, the financial services provider (FSP), on the basis it was due to gradual deterioration, wear or tear. The applicant has disputed this as he says the cause of damage was due to a box gutter leak that occurred in March 2013. 1.2 Issues and key findings Can the FSP deny the claim? The FSP can deny the claim because:  the evidence demonstrates the cause of the damage was gradual deterioration, wear or tear  the policy excludes loss or damage caused by these factors 1.3 Determination This determination is in favour of the FSP. The FSP is entitled to deny liability for the applicant ’s claim. Case No: 444369 Determination Page 2 of 7 2 Reasons for determination 2.1 Can the FSP deny the claim? FSP says damage caused by gradual deterioration, wear or tear These relevant facts are not in dispute:  on or about 23 March 2013, the box gutter above the bathroom and passageway had given way  the passageway ceiling collapsed and the bathroom ceiling buckled and bowed  the ceiling damage was repaired by a plasterer and the applicant replaced the box gutter  on 3 November 2014, the applicant lodged a claim for internal water damage to their shower and bedroom wall that they noticed the previous month  at the FSP’s request, a water pressure test was performed – no leaks were found The FSP subsequently investigated the claim and agreed to pay for the repairs to the bedroom wall. However, it denied liability for the shower and resultant damage on the basis it falls with the following policy exclusion: “We will not cover your building and your cont ents for any accidental loss or accidental damage caused by:  …  Rust, corrosion, gradual deterioration, depreciation, depreciation, wear or tear.” The FSP has the onus of establishing that the exclusion applies. The standard of proof is the balance of probabilities. The parties dispute the cause of damage The applicant is relying upon expert UB, a tiler, to support his position. UB says the damage to the tiles and subsequent water ingress are all due to the water leak in 2013. UB says water trapped in the wall from this leak has acted as a releasing agent of the tile’s adhesive and also resulted in its crac king. The FSP says the damage is consistent with gradual deterioration, wear or tear. The FSP is relying upon the evidence of two experts to support its position. These are RH, a building consultant, and IB, a senior structural engineer. Numerous reports and emails have been provided by these experts. These have been summarised at the back of this Determination. IB’s opinion is preferred IB’s reasoning as to why the damage is not consistent with UB’s opinion is persuasive. For instance:  there are drummy tiles remote from the location of the leak  wall tiles below the height of the shower tapware were bulging before the leak  there was no evidence of damage to the wall surface at a higher level Case No: 444369 Determination Page 3 of 7  there is evidence of footing movement proximate to the bathroom a nd bedroom that has resulted in cracking and degradation to the masonry – this could have affected the tiles  evidence of non-uniform grout margins or grouts of a different texture show previous repairs These observations are consistent with attached photographs. The applicant and UB have challenged some of these reasons. They say that whilst the bulging was noticed beforehand, it had not exacerbated before the box gutter leak. Further, the leak was significant as it extended to the western wall and therefore explains the damage there. However, it does not refute the fact there is evidence of pre-existing issues. This is supported by the grouting and bulging. Further, the evidence of footing movement resulting in cracking and degradation to the masonry within close proximity of the bathroom could reasonably effect the integrity of the tiles. In addition, the absence of any damage higher up the wall is inconsistent with UB’s opinion that water trapped in the walls could have been the cause of all the damage. Therefore, when I consider all the available evidence, I am satisfied it lends greater support to IB’s reasoning as to the cause of damage. Namely, that in the absence of any other leak, it is consistent with gradual deterioration, wear or tear. The cause of damage falls within an exclusion clause After careful consideration of all the available evidence, I am satisfied it shows on the balance of probabilities that the cause of the damage is gradual deterioration, wear or tear. As this falls within the exclusion clause, the FSP is entitled to deny liability for the applicant’s claim. Case No: 444369 Determination Page 4 of 7 3 Supporting information 3.1 Expert Evidence Record Key points FSP’s expert (RH) Report 06 March 2015  Insured confirmed no further water ingress or ceiling damage occurred since the box gutter leak Bedroom  Cracking, including bubbling and blistering, was observed in the southern internal wall – this is common wit h the bathroom  Similar damage was observed along the western external wall  Blistering and patching damage was observed to the bedroom’s western wall in the south west corner  These damages were consistent with water ingress  Elevated (red) moisture readings up to 750 at various locations along the cracking and blistering damage  Dry (green) moisture readings up the w all from approximately 200mm above the line of cracking and blistering damage  Slightly elevated (yellow) and/or dry moisture readings at the blister damage areas of the southern and western walls  No water staining to timber skirtings underneat h these areas Bathroom  Two vertical cracks identified on the northern wall – this is common wit h the bedroom  Vertical and horizontal cracking following the stretcher bond shape of the tiles through both the wall tiles and grout joints on the northern wall  Wall tiles in this general area are not fully bedded (drummy)  Water from general shower use is able to ingress the wall substrate through the noted areas of cracking  Height of the cracking damage is consistent with the damage observed on the bedroom side  Similar vertic al cracking identified on the western wall of the shower Roof & Roof void  Roof is generally in good condition  Evidence of wat er staining to a number of roofing timbers adjacent to the box gutter.  This water staining is likely old damage and occurred prior to the re - roofing of the residence and replacement of box gutter Conclusion  All of the damage is consistent with water/moisture ingress entering the wall substrate through the cracked wall tile/grout area in the shower recess  The cracking has occurred as a result of wear and tear and general building movement over an extended period of time  It is not as a result of rain water ingress from the old leaking box gutter in March 2013 Case No: 444369 Determination Page 5 of 7 Applicant’s expert ( U B) Report 10 April 2015  He has work ed in the tiling industry for 52 years  The box gutter is situated directly above the dividing wall of the bathroom and bedroom which is of brick construction  The older brick and plastering would have abs orbed the water  The moisture would have fallen down to the bottom afte r a period of time – this explains the high moisture readings as the water would have been trapped  Between the water, the render coat and the lime, a chemical reaction occurs where effervescence forms – this causes blistering  The bathroom was installed cor rectly  Water that was trapped behind the tiles expanded when hot and cold water was used in the shower – this caused the tiles to crack  The damage is consistent with the previous leak FSP’s expert (IB) Report 26 May 2015 Observations  The applicant’s wife reported that a shower alc ove wall tile had a bulge before the gutter leak  The northern shower alcove wall tiles sounded solid at border tile height – at about 1 meter below the border tiles, there was a hollow sound  Two tiles were cracked on the nort hern wall  The drummy tiles spread in a triangular pattern toward floor level  There is similar damage to the tiles on the western wall – tile joints are loose with grout and there is stepped cracking to the grout joints around the shower rose  There is fretting a nd efflorescence damage to the hard plaster wall surface in the bedroom  High (red) moisture readings were recorded just above the skirting height and upwards by approximately 200mm  Yellow readings were recorded to the western wall towards the window  Readi ngs were green above the shower border tile toward the ceiling and above the height of the visual damage in the bedroom Discussion  Damage is not due to the box gutter leak  Moisture, if it is soaked into the body of the brickwork, would want to evaporate to wards its closest surface  No indication of moisture related activity to the top of the wall and damage to the shower alcove is not at its greatest level at border tile height  Damage to wall tiles on northern wall consistent with the zone of maximum wat er s plashing and runoff  Drummy condition of tiles is widespread and not just confined to the northern wall  There was previous bowing/ delamination of the tiling before the box gutter leak and likely to have gotten worse over time  The ability of the shower alcov e to remain impervious to Case No: 444369 Determination Page 6 of 7 water has been gradually deteriorating over time – the origin is not the box gutter leak  In the absenc e of any underfloor pipe or other leak, the damage is consistent with the failure of the tiling to prevent water entry and the failure of any waterproofing surface behind the wall tiling App’s expert (UB) Report 15 June 2015  He believes a fair amount of water would have drained into the actual cavity where it was trapped – this was why such a high reading was obt ained for the out side wall  The trapped water had nowhere to go  Waterproofing was likely applied given it was constructed around 1993 or 1994  Reiterates conclusion that water trapped in the tiles and rendering resulted in the damage – this is connected to the box gutter eve nt FSP’s expert (IB) Email 17 July 2015  No record of visible water entry into the bedroom affecting the ceiling and top of the wall – not like the report of water ent ry into the bathroom and passage outside the bat hroom  Damage to bathroom tiling is not confined to shower alcove  There are drummy tiles remote from the location of the overflowing box gutter’s influence  Wall tiles on the other side of the room to the shower were drummy – they were comparable to the condition of some of the shower alcove tile s  It was reported that wall tiles below the height of the shower tapware were bulged/delaminated before the overflow  Does not agree with UB’s conclusion – there would have been some evidence of damage to the wall surface at a high level – this is due to th e water trying to evaporate through the less impermeable material surface compared to a tiled wall surface  Mortar debris bridging a cavity wall construction may have caused some water “build - up” allowing some transfer App’s expert (UB) Email 19 November 2015  Render coat is a lime render coat with no cement – a putty coat was then applied on to that  No waterproofing applied as not necessary  With the render coat being as porous as it was, the water acted as a releasing agent FSP’s expert (IB) Email 16 Dece mber 2015  Photos show grout finish is not consistent with the other areas of the wall surfac e  Grout margins are non - uniform and of a different texture – this is consistent with historical repair  External footing beam and masonry wall surface in the vicinit y of the bathroom and adjacent bedroom show signs of footing settlement  These have been occurring over a long time and have contribut ed to the deteriorat ed condition of the bathroom wall lining  If the box gutter leak had caused tiles to delaminate and grou t Case No: 444369 Determination Page 7 of 7 to crack, then some damage would manifest to the wall surface above the bathroom wall tiling – there is none  It is possible the box gutter leak cause some slight exacerbation – however, it was not the initiating cause App’s expert (KB) Report 25 January 2016  The description of the damage indicated it may have resulted from a downpour  The matter was referred to two associates who were unable to comment without a site inspection  For one wall to “flake” and/or bulge and be a common wall to the bathroom does warrant further investigation into the cause App’s expert (UB) Report 07 March 2016  Upon stripping the shower, there was limestone render and the tiles had 100% coverage in adhesive  The grouting was not porous and could not be raked out with your fingers

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.