Home / Financial Firm (Unknown - Insurer) / Determination 441933

Determination 441933

Cracking damage claim declined under ground movement exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2017-07-31
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicants claimed for cracking to their home that they said was caused by a leaking septic tank, and the FSP declined under its ground movement exclusion. AFCA found the leaking tank was the dominant cause of the damage, an insured event, and ordered the FSP to meet the claim under the policy terms.

The proximate cause of the loss was the insured escape of liquid from the septic tank rather than the excluded ground movement, which would not have occurred without the leak.

Issues

Subjects and remedies

home or building damagepay claim

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 441933 Determination Page 1 of 8 Case number: 441933 28 July 2017 1 Overview 1.1 Dispute The applicants hold a defined events Home and Contents Insurance Policy (the policy) with the financial services provider (FSP). The applicants made a claim under the policy in relation to cracking damage to their home resulting from ground movement. The applicants say that ground movement was caused by a leaking septic tank. The FSP declined the claim on the basis that the leak was not the cause of the damage. 1.2 Issues and key findings Has an insured event to which the policy responds occurred? It is not in dispute that liquid escaped from the applicants‟ septic tank or that the policy provides coverage for damage caused by the escape of liquid from a sewerage system. Did the leak cause the ground movement related damage? I am satisfied on balance, that the escape of liquid from the applicants‟ fractured septic tank caused abnormal and differential rates of soil swelling and heave under the home and the loss claimed. I am satisfied that in the absence of the escape of liquid from the septic tank, heave associated ground movement would not have occurred and the applicants would not have suffered the claimed loss. The dominant effective caus e of the applicants‟ loss was the escape of leachate from t he tank, not ground movement. Consequently, the FSP is not entitled to rely upon the general exclusion in the policy for loss caused by or arising from ground movement. The proximate cause of the applicants ‟ loss was the escape of liquid from the septic tank, which is an insured event under the policy. Was the FSP entitled to decline the claim? The FSP is not entitled to deny the claim in reliance on a general policy exclusion relating to damage caused by ground movement. Absent the escape of liquid (for which the policy provides cover) from the septic tank, the ground would not have moved resulting in cracking damage to the applicants ‟ home. Case No: 441933 Determination Page 2 of 8 1.3 Determination This determination is in favour of the applicants. The FSP is liable to meet the claim in accordance with the terms and conditions of the policy. Case No: 441933 Determination Page 3 of 8 2 Reasons for determination 2.1 Has an insured event to which the policy responds occurred? The policy provides cover for damage caused by a leaking septic tank The policy provides coverage for damaged caused by the escape of liquid from a sewerage system. Page 22 of the policy provides as follows: “Escape of Liquid: We Cover - Loss or damage to the building caused by liquid leaking, overflowing or bursting from any of the following: … any drain, fixed pipes, roof gutters or guttering and rainwater downpipes, drainage and sewage systems." It is not in dispute that the septic tank is located within three metres of the applicants‟ property and was leaking for some years. Whether the leaking septic tank caused the claimed damage is in dispute Several of the reports provided by the parties and summarised in section 3 of this determination, speculate as to the cause of the claimed damage, including ground movement resulting from reactive soils, vegetation and tree roots, the adequacy of the footings of the home as well as leaching from the septic tank. The parties disagree about the proximate cause of the loss. 2.2 Did the leak cause the claimed damage? The experts agree about the reactive soils The expert reports provided by both parties acknowledge that:  the land on which the property is built was previously agricultural land and consequently would be subject to „drying out‟ and associated movement /settlement  the soils are clay and highly reactive  liquid has leached from the tank The experts disagree on whether the escaped liquid from the septic tank is the dominant cause of the movement related cracking damage to the ap plicants‟ home. The applicants say that it is the main cause and the FSP says it is not a causal factor at all. The FSP’s position regarding natural settling and the impact of vegetation is not persuasive The parties disagree on the significance of the previous agricultural use of the la nd on which the applicants‟ house sits and whether the ground movement under the home is as a result of natural settling. The FSP asserts that given the previous use of the land, soil drying combined with the drying action of tree/shrub roots around the Case No: 441933 Determination Page 4 of 8 ap plicants‟ house caused the ground movement, which resulted in turn in the cracking damage claimed. The applicants note that the land was fallow and not irrigated for some time prior to the construction of their home, meaning the soils had settled prior to the construction of their home. Given the hot and dry climatic conditions in the region, I accept that the soils had time to dry and settle prior to construction. The applicants say further, that the differential, and in some cases extreme, cracking and horizontal shearing of the masonry, plus evidence of heave in other places is not co nsistent with normal settling. The applicants note that the shrubs around their house are native shrubs with low water needs and have provided information to support this. The applicants‟ assertions are also supported by the photographs provided by the FSP‟s expert, which I have closely reviewed. I am not persuaded that vegetation is the proximate cause of the claimed damage, particularly given the distance between some of the worst affected areas of cracking damage and the nearest vegetation. The applicants’ home is in a hot and dry, semi -arid area The applicants‟ home is situated in a semi -rural and inland location with a climate described by the Bureau of Meteorology as semi-arid. Data from the bureau consistently shows average summer day time temperatures consistently well exceeding 30 degrees Celsius. I am satisfied that the soil under the applicants‟ home would have dried sufficiently prior to the construction of the app licants‟ home. I am not persuaded that the land‟s prior use and consequent settling of the land after the change in use is a material causal factor in the claimed loss. The FSP has not shown that the leachate did not reach the building footprint The FSP‟s engineer says that the leeching from the septic tank was localised and did not r each the building‟s footprint. The report notes the lack of staining to walls proximate to the tank, as well as the lack evidence of localised heave or subsidence in the area proximate to the tank, as evidence of this amongst other things. I note that the FSP‟s assertion that the leachate did not reach the building‟s footprint is speculative. Conclusive tests on this point have not been undertaken by the FSP. In response, the a pplicants‟ expert says that leachate from the septic tank could have and likely did, travel downhill along footing trenches and under the house. The applicant says this would explain the lack of localised heave proximate to the tank, as well as the cracking damage to parts of the house some distance from the tank. The applicants‟ experts suggest this could also be the cause of the heave at the centre of the slab, causing the outer parts of the slab to subside and the cracking and horizontal shearing observed in the exterior walls of the building. On balance I accept that the leachate reached the building footprint The parties have provided conflicting information in relation to heave in the slab of the applicants‟ home. The FSP has provided measurements showing that the exterior walls are lower than a selected point in the living area, however the FSP‟s report does not address whether there is evidence of heave in the living area. Case No: 441933 Determination Page 5 of 8 The topographic information provided by the parties shows that the applica nts‟ block does have sufficient slope for leachate from a tank located 250cm from the house to reach the footprint of the building. Photographs show black leachate staining on the soil next to the stained and cracked tank with lighter coloured grey staining extending along a defined line (consistent with a backfilled piping trench or the like) away from the trench and towards the house. Given the reactivity of the soils, the presence of that staining line and the hot summer temperatures in the local area, I am satisfied that leachate could have escaped from the septic tank, seeped upwards (particularly during hot periods) and travelled along a backfilled trench line on the slight downslope towards an d under the applicants‟ house. I am satisfied that this would result in ground movement under the home. The available information shows that in the months after the leaking septic tank was decommissioned, backfilled and replaced, the cracking to the applicants‟ house ceased. This lends credit to the applicants‟ position that the leachate from the septic tank directly caused the cracking to their home by saturating the soil under the home and causing heave. The proximate cause of the ground movement is the escape of liquid from the septic tank It is acknowledged by both parties that there are several external forces that can result in ground movement and consequent cracking to a building. The parties dispute the operative or dominant cause of the ground moveme nt under the applicants‟ home. Having considered and weighed all of the available information in this dispute, I am satisfied that the proximate cause of the ground movement and consequent cracking at the applicants‟ propert y was the leaking septic tank. I am not persuaded that the ground movement and cracking would have occurred absent the escape of liquid from the septic tank. 2.3 Was the FSP entitled to decline the claim? The policy excludes cover for damage caused by ground movement Page 36-37 of the policy contains general exclusions from cover. One of those exclusions is for damage involving ground movement. The policy provides as follows: “You are not covered under any section of your policy for damage, loss, cost or legal liability that is caused by, arises from or involves:…. Ground movement erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage or any other earth movement, but we will cover landslide or subsidence that is specifically covered under the following insured events:  „Storm‟;  „Flood‟ (but only if you have cover for insured event „Flood‟);  „Earthquake and Tsunami‟;  „Explosion‟.” Case No: 441933 Determination Page 6 of 8 The soil under the applicants ‟ home would not have been subject to the abnormal and differential degree of swelling and heave that it was, if it were not for the escape of liquid from the septic tank. It is the escape of liquid that caused the soil movement and associated cracking to the applicant‟s home, as the soil underneath the home moved at differential rates when some areas of soil became saturated by the leachate from the tank and swelled, while dry areas did not. That is, if it were not for the escape of liquid from the septic tank, the ground under the applicants‟ home would not have moved the way it did, and the house would not have sustained the loss claimed. At law, the proximate cause of a loss, is the dominant or effective cause of that loss. The proximate cause of the applicants ‟ loss is the leaking tank, not ground movement. The ground movement would not have occurred in the absence of the leak. Consequently, the above exclusion is inapplicable. As the direct and proximate cause of the loss is an insured event (the escape of liquid), the FSP cannot rely upon the general policy exclusion relating to ground movement to deny the claimed loss. The FSP is not entitled to deny the claim. Case No: 441933 Determination Page 7 of 8 3 Supporting information 3.1 Key reports The following key reports (summarised below) have been considered in this determination together with all submissions made by both parties. Report from the applicants’ plumber QS  QS provided a report w hich states there was a crack around three quarters of the circumference of the septic tank large enough to fit a finger through.  QS says the crack allowed water to seep out and soak towards the building. He says being only two and a half metres from the b uilding (within code), the water was tracking underneath the building which was on the tank‟s downside.  QS says it could not be determined how long the leak had been occurring, but suggests it would have been for quite some time as the soil around the tank at a depth of two and a half metres was very wet and had turned black from the liquid.  QS states that there were no other leaks existing at the property Report from the FSP’s engineer FMG  FMG reports that there was no structural damage to the insured property, with some easily repairable cracks.  FMG acknowledges there was a leaking septic tank, located three metres from the property. However, it says the pattern of cracking is more consistent with soil shrinkage and settlement. It says if the septic talk caused the soils to heave, it would cause a rise in the vicinity of the tank, but this is not the case.  FMG confirms the land was previously used for farming and regularly watered. It says whilst it would have been barren for a period of time before construction, soil shrinkage would continue due to moisture evaporation.  FMG also says trees and shrubs would contribute to footing movement.  FMG says differential settlement occurred after construction and continued due to seasonal moisture changes in the soils, exacerbated by the roots of nearby trees and shrubs extracting moisture.  FMG says there is no distress in the vicinity of the tank paving, so it is extremely unlikely the leak contributed to the damage and settlement. Report from the applicants’ enginee r PC  PC opines that it is not credible to discount the septic tank on the basis it is three metres away from the property. He says the lack of distress to surrounding paving fails to acknowledge the movement is a result of unusual or abnormal moisture related events. The moisture could migrate underneath the property along the sand backfilled underfloor plumbing trenches and so causing the movement observed.  PC says the tree growing at the end of the building could be affected by elevated moisture underneath the building with movement being caused by the tree and enhanced by the abnormal moisture levels. The event and effects observed is the leaking septic tank upslope of the building position. Case No: 441933 Determination Page 8 of 8  PC says if the movement was related to prior land use, it would have been expected to see uniform damage along the building.  PC provides a diagram of the predicted water flow from the sceptic tank under the central part of the building towards the master bedroom. An email from a second engineer CS, provided by the applicants  CS appears to have provided a report sight unseen on the property concerning whether a leaking septic tank could cause cracking to walls.  CS says a leaking pipe or tank can provide a moisture source to reactive soils, particularly deeper reacti ve layers contributing to soil and building movement.  CS says that depending on what is used to backfill trenches, moisture can also move along a trench backfilled with sand.  CS says that the movement of the building and observed damage is typical of local ised increases in soil moisture content along the rear of the building. Second report from the FSP’s engineer FMG  In response to the applicants‟ reports, the FSP engaged FMG to respond to the matters raised.  FMG reports that the damage observed to the building is consistent with settlement towards the edges, not heave.  FMG notes that -  Photos of the damaged tank suggests the leachate did not reach the building footprint, evidenced by the lack of staining to the tanks concrete walls.  The footings to the building did not account for the effects of trees on the extremely reactive foundation soils and have contributed to the observed damage.  With regards to the leak being „upslope‟ of the building, the topographical map shows the site being relatively flat.  Wit h regards to moisture travelling along the footing beam and service trenches, the septic tank is positioned below the trenches. For example, the footing beam trench is 700mm whereas the tank is set at two metres. FMG says on this basis the leakage from the septic tank has not caused or contributed to the distress and settlement of the property.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.