Claim denied under policy exclusions for storm-related water seepage

FirmFinancial Firm (Unknown - Insurer)
Decided2017-04-20
ProductGeneral Insurance · Landlord
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant's landlord property insurance claim for storm-related water damage was denied by the FSP under policy exclusions. AFCA found the FSP entitled to deny the claim.

Water seepage through the wall was likely caused by gradual failure of waterproofing (wear and tear) and was excluded, and the FSP discharged its onus on the exclusions.

Issues

Subjects and remedies

natural disasterno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 441323 Determination Page 1 of 7 Case number: 441323 19 April 2017 1 Overview 1.1 Dispute This matter involves a claim by the applicant under her Residential Landlords Property Insurance Policy, held with the financial service provider (FSP), following damage to the insured property as a result of a series of storms between November 2014 and 31 January 2015. The FSP has denied the applicant’s claim on the basis of a number of exclusions within the policy, including exclusions for flood; mildew or mould; any gradual deterioration or depreciation, wear and tear, rust or corrosion; water seepage or percolation through a wall, floor or roof; and the cost of repairing or replacing any damaged or defective fixed tanks, guttering or pipes or other fixed apparatus (or any part of them) used to hold or carry liquid of any kind. 1.2 Issue and key findings Is the FSP entitled to deny the claim on the basis of exclusions within the policy? The FSP is entitled to deny the applicant’s claim on the basis of exclusions within the policy. 1.3 Determination This determination is in favour of the FSP. The FSP is entitled to deny the applicant’s claim. Case No: 441323 Determination Page 2 of 7 2 Reasons for determination There has been a full exchange of material between the parties and each party has had the opportunity of addressing the issues that arise from the material exchanged. This determination follows consideration of all of the information exchanged and is based on what is fair in the circumstances, having regard to the relevant legal principles, terms of the policy, good industry practice and where applicable, prior determinations. Whilst the Panel has considered all of the information that has been exchanged, only that information relevant to the final outcome will be referred to within t his determination. 2.1 Is the FSP entitled to deny the applicant’s claim on the basis of exclusions within policy? Coverage of the policy The coverage provided by the applicant’ s Residential Landlords Property Insurance Policy, is detailed within the Product Disclosure Statement (PDS). The PDS details: … The policy also includes definitions which are contained within the PDS: The coverage provided by the policy is subject to the exclusions which are also detailed within the PDS. The PDS details: … … Case No: 441323 Determination Page 3 of 7 … … It is accepted insurance law that the applicant carries the initial onus to establish that she has suffered loss and damage which is covered by the terms and conditions of the policy. As the policy covers ‘ Accidental loss or damage to Your Building ’ , this means in this instance that the onus shifts to the FSP to establish the basis on which it seeks to deny the applicant’s claim, including its reliance upon exclusions within the policy. Circumstances of the loss The applicant says that as a result of cyclonic storm/flood water, between 14 November 2014 and 31 January 2015, there was damage at the insured property. The FSP does not dispute the applicant’s submission but says that the water that seeped into the property did not originate from flood but rather from rain/storm activity between November 2014 and January 2015. The FSP says that the water entered into the house by seeping through the besser brick wall and as a consequence the water damage is excluded by operation of the exclusions within the policy. The parties have provided reports in support of their respective positions. Reports The FSP engaged Loss Adjustors (CL) who attended onsite on 1 May 2015. CL reported they understood that a cleaner had completed a test clean which was unsuccessful and that the cleaner suggested to the insured’s managing agent that there was most likely a membrane breakdown/water ingress issue. Whilst CL expected that the original house construction would have included water proofing applied to the exterior of the concrete filled besser blocks, it was impossible at the time of the inspection to determine if a membrane was painted onto the wall and if suitable materials were positioned between the wall and natural earth. CL reported that if the required barrier was not used, it was likely that the utilised sub field could absorb moisture and react/expand, potentially rubbing against and causing sections of the applied membrane to fail. The FSP engaged a leak specialist (AD) to attend onsite and report. Case No: 441323 Determination Page 4 of 7 Following inspection, AD reported: … … The applicant engaged a consulting structural engineer (SR), who attended onsite on 30 November 2015. Within a report dated 12 January 2016, SR noted: … … Discussion The Panel has considered all of the reports provided, together with the submissions made in support of the respective positions. The Panel is of the view that the likely cause of the seepage of water into the property was the failure of the water proofing and that this occurred over an extended period of time. The applicant, in countering this possibility has reported the absence of previous water entry; however, the Panel is satisfied that the location of the insured property has inevitably been the subject of significant storms in the past. Contrary, therefore, to the applicant’ s counter-argument of the preceding paragraph, the absence of previous storm generated water entry supports the Panel's position that the deterioration in the water proofing occurred over a period of time and as a result of one of the policy exclusions relating to 'wear and tear'. The Panel is also satisfied that the water seepage would not have occurred but for the failure of the water proofing. The result is that the FSP is entitled to deny the applicant’s claim on the basis of the exclusions within the policy. Case No: 441323 Determination Page 5 of 7 3 Supporting information 3.1 FOS approach There has been a full exchange of the relevant material between the parties and each party has had the opportunity to address the issues raised. The Panel has reviewed and considered all of the material provided by the parties. While the parties have raised numerous issues in their submissions, for the purposes of this determination, the Panel has restricted its commentary to those issues which it considers directly relevant to the outcome only. The applicant has been represented. For the sake of clarity and brevity in this determination, the applicant and her representative have been referred to as ‘the applicant’ . 3.2 Relevant extracts from product disclosure statement Definitions Words that begin with a capital letter have a special meaning when used in the Policy. The meanings of these words are given below: Accident or Accidental means an event of an unforeseen and unint ended nature and includes a series of accidents arising out of the one event. … Section 1 - Building Cover What is covered This cover only applies when Building cover is selected by You and is specified as covered in the Schedule. We agree to cover You for Accidental loss or damage to Your Building that occurs during the Period of Insurance. … General Exclusions This Policy does not cover any loss, damage, liability, compensation, paym ent, cost, fee or expense caused by, arising directly or indirectly out of, or in any way connected with: 1. Flood … 3. Mildew or mould. 4. Any gradual deterioration or depreciation, wear and tear, rust or corrosion. … 10. Water seepage or percolation through a wall, floor or roof. … 28. The cost of repairing or replacing any damaged or defective fixed tanks, guttering or pipes or other fixed apparatus (or any part of them) used to hold or carry liquid of any kind. 3.3 Key points on relevant expert material Record Key points FSP’s loss assessor (C L ) First Report  The original construction would have had tanking (wat erproofing) applied to the exterior of the concret e filled Besser blocks, with sand or similar material backfilled into the void between tanked walls and the nat ural ground fill. Case No: 441323 Determination Page 6 of 7 19 May 2015  Following heavy rain activity over Dec ember 2014 / January 2015, the tenant discovered mould had developed on plasterboard wall sheeting in the storage area under the stairs.  The widespread damage suggests water is penetrating the rear core filled Besser block wall in numerous areas.  A natural watercourse may exist under the property. Following saturation of the sub - ground during prolonged rain activity, rainwater is travelling via capillary action and penetrating the sub - ground Be sser block wall.  It is impossible to determine if a membrane was painted onto the wall and if suitable materials were placed bet ween the wall and nat ural earth.  If the required barrier was not used, it is likely the subfield could absorb moisture and expan d, rubbing against, and causing sections of the membrane to fail.  This would explain why moisture has only recently penetrated the wall.  The membrane appears to have recently failed. Water seepage or percolation through a wall is excluded. FSP’s leak spec ialist (AD) Report 24 June 2015  CCTV inspection was done to the guttering on the high side of the house.  A crack was found in the top half of the stormwater pipe, about 1m from the front corner of the garage, under the concrete path.  The remaining pipe run s across the front lawn, through a pit drain and discharges at the side, flowing toward the neighbouring property.  A ‘ washout ’ hole was seen near the connection of the downpipe from the roof to the stormwater pipe in the ground. There is a gap bet ween the two - pipe connection (front corner of the garage).  There is a low point bet ween the front door and the side of the garage, in a gravel garden bed. If gutters overflow, water would pool in the gravel garden below. With no visible drainage to the front walls of the house, water would run toward and pool against the house.  The break in the stormwater pipe and the gap in the connection bet ween the downpipe and the stormwater pipe would contribute to the water ingress, but it is not the main cause.  The water damage inside the house appears to be a combination of poor drainage across the front of the house and a breakdown of any waterproofing applied to the front of the house. Applicant’s agent (M) Letter 17 September 2015  The damage to the property was caused by cyclonic storm/floodwat er between 14 November 2014 and 31 January 2015.  The cause of damage involved disintegration and integrity of a singular arterial downpipe and stormwater pipe system, that contributed to the massive water ingress and was the sing ular contributing factor in the extensive damage through saturation flooding of the house’s internal area. Applicant’s agent (M) Report Undated  The damage was due to a short - term series of storms from 14 Novembe r 2014 to 31 January 2015 (the ‘ storm events ’ ).  Thunderstorms added to the unsustainability of the major drainage downpipe and the stormwat er pipe, which formed the only deterrent for the dryness of the house’s internal structures.  The prime cause of damage must be attributed to the fracture of a ma jor arterial downpipe. Cons equently, the dislocation allowed rainwater from the roof to swamp the internal structures at the front of the house.  The subterranean drainage net work system at the front of the house had Case No: 441323 Determination Page 7 of 7 been intact and working normally before, during and after the storm events.  The intensity and sheer volume of water during the storm events spread across a wide area and was the sole cause of damage, due to the destruction of the int egrity of the art erial downpipe and its disconnection to an art erial stormwat er pipe.  The breach between the downpipe and stormwater pipe falls in a straight line directly to the stairwell landing, which like both sides of the landing, shows severe swelling and blistering of plasterboard walls.  Severe swelling and bli stering continues through the inner downstairs games room wall and the corridor inner int ernal wall.  Once water found its way to the left and right of the Besser brick walls under the stairwell landing, it penet rated the walls and pressed its way through t he Besser bricks and internal plasterboard walls below the central stairwell landing, then flowed along the whole eastern and southern side of the front of the house.  The managing agent and the applicant have shown that before the storm events, the house w as dry with no water int rusion.  Neither AD nor C L can substantiate, beyond reasonable doubt, the damage was as a direct or indirect result of seepage or percolation through a wall (inferring a disturbance over time).  The most crucial factor was that, because of the breach of the downpipe and the stormwater pipe, the stormwater pipe was no longer connected to the remaining pipe across the lawn. Applicant’s engineer (S R ) Report 12 January 2016 Emails on 5 & 7 December 2015  It is storm damage. It is the result of rainfall (storm) events. Cause of water damage is predominantly stormwater runoff.  As seen on 30 November 2015, the moisture barrier systems to the lower floor areas had evidence of advanced dilapidation / inundation, resulting in extensive moist ure damage to that part of the building.  Primary moisture supply source is rainfall runoff from the lot and adjacent uphill properties.  The broken subsurface stormwater line located on the northern aspect of the building would have been, before repairs, a significant contributing factor to the extent of damage observed.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.