Home / Financial Firm (Unknown - Insurer) / Determination 438364
Determination 438364
Home cracking and movement damage claim denied under earth movement exclusion
Summary
The applicants claimed for cracking and movement damage to their home, attributing it to leaking neighbouring stormwater pipes. The FSP denied the claim as excluded earth movement, and AFCA agreed the FSP is not liable.
The FSP showed the proximate cause was naturally occurring earth movement, which the policy excludes, rather than the leaking pipes.
Issues
- Claim denial primary · not upheld“the cracking and movement damage ... was caused by naturally occurring earth movement and not by the effects of water from the leaking pipes”
Subjects and remedies
home or building damageno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
Case No: 438364 Determination Page 1 of 6
Case number: 438364 21 April 2017
1 Overview
1.1 Dispute
The applicants lodged a claim under their home insurance policy with the financial
services provider (FSP) for cracking and movement damage to their property. The
applicants consider the damage was caused by water leaking from cracked storm
water pipes at their neighbour’s property.
The FSP denied the claim on the basis that the damage was not caused by leaking
pipes (or by any other event insured against under the policy) but by naturally
occurring earth movement over a prolonged period of time, which is excluded from
cover under the policy.
1.2 Issues and key findings
Is the FSP liable for the damage to the applicants’ property ?
The available information establishes that, on the balance of probabilities, the
cracking and movement damage to the applicants ’ property was caused by naturally
occurring earth movement.
The nature and extent of the damage is not consistent with it having been caused by
water leaking from the damaged storm water pipes at the neighbouring property.
Damage caused by naturally occurring earth movement is not covered under the
policy. Accordingly, the FSP is not liable for the applicants ’ claim.
1.3 Determination
This determination is in favour of the FSP.
The FSP is not liable for the damage to the applicants’ property .
Case No: 438364 Determination Page 2 of 6
2 Reasons for determination
2.1 Is the FSP liable for the damage to the property?
Policy provides cover for insured events subject to exclusions
The applicants are required to show that, on the balance of probabilities, they have
suffered a loss caused by a risk insured against under the policy. This is known as a
valid (or prima facie ) claim.
If the applicants are able to establish a prima facie claim, then the onus shifts to the
FSP to show that, on the balance of probabilities, it is entitled to rely on an exclusion
under the policy or is otherwise entitled to deny the claim.
The applicants’ p olicy provides cover for damage caused by the events listed in the
policy (including liquid leaking from a fixed pipe or drainage system), subject to the
conditions and exclusions set out in the policy.
Applicants have established a prima facie claim
The available information establishes that damaged stormwater pipes were
discovered at the applicants’ neighbour’s property in February 2015.
Four separate sections of broken and blocked piping were identified in areas
adjacent to the western boundary of the applicants’ property . Three of these sections
were located towards the rear of the applicants ’ garage, while the fourth was near the
front of the neighbouring garage.
The reports prepared by the engineers appointed by the parties (SS and FM) confirm
that the applicants’ property has suffered extensive cracking and movement damage.
The applicants have advised that this damage commenced in around mid-2012,
approximately twelve months after their house was built.
In these circumstances, the panel is satisfied that the applicant has established a
prima facie claim under the policy.
Accordingly, the FSP bears the onus of establishing that, on the balance of
probabilities, it is entitled to rely on a policy exclusion or is otherwise entitled to deny
the applicant s’ claim.
The FSP says it is not liable for the claimed damage because the leaking stormwater
pipes did not cause the cracking and movement damage to the applicants ’ home.
The FSP says the damage was caused by earth movement over an extended period
of time, as a result of naturally occurring variations in the moisture content of the
highly reactive clay foundation soils.
The policy excludes cover for damage caused by subsidence, collapse, shrinkage or
any other form of earth movement (other than landslide or subsidence which is
specifically covered under certain insured events).
In order to establish that it is entitled to deny the applicants ’ claim, the FSP must
show that the proximate cause of the cracking and movement damage (that is, the
Case No: 438364 Determination Page 3 of 6
real, effective or dominant cause) was naturally occurring earth movement (and not
the effects of water leaking from the broken stormwater pipe).
Engineers have provided differing opinions
Both engineers appointed by the parties confirmed that the applicants ’ property was
founded on highly reactive clay soils, which were susceptible to volumetric changes
as a result of variations in moisture content.
However, the engineers have provided differing opinions about what caused the
cracking and movement damage which is the subject of the current claim .
The applicants’ engineer (SS), who was originally appointed by the builder of the
property, concluded that the damage had been caused by heave (upwards
movement) as a result of the expansion of the foundation soils due to the effects of
moisture from the leaking stormwater pipes.
Following his initial inspection in February 2015, SS advised that:
floor levels taken at the property indicated movement in the footings of up to
55mm between the front and the rear of the garage and 35mm between the
garage and the entry area to the east;
the building movement was concentrated towards the western part of the
house;
he had observed water slowly filling up a hole excavated towards the rear of the
applicants’ garage, which triggered an investigation of the neighbour’s storm
water pipes; and
he considered the building movement was consistent with having been caused
by the effects of water leaking from the pipes.
SS subsequently conducted a further inspection in March 2016, during which he
carried out level surveys of the entire house and undertook soil moisture testing, the
results of which indicated that the soil had a higher moisture content in areas near
the leaking stormwater pipes. SS reconfirmed his view that the leaking pipes had
caused the damage.
The FSP disputes that the damage was caused by the effects of water from the
stormwater pipes, based on the findings of its engineer (FM), who inspected the
property in October 2015.
Based on the results of her floor level surveys, FM concluded that the pattern of
differential movement at the property was more consistent with having been caused
by ‘edge heave’ than by the leaking stormwater pipes.
FM advised that ‘edge heave’ occurs where the perimeter of the slab is pushed
upwards as the soils underneath it expand, due to being exposed to higher moisture
conditions than the centre of the slab, which is less exposed to the elements.
FM considered the applicants’ pr operty was particularly susceptible to edge heave
due to factors including:
the use of a concrete waffle pod slab on a site with highly reactive clay soils,
which has previously been associated with incidents of edge heave ;
Case No: 438364 Determination Page 4 of 6
the presence of unpaved areas around the perimeter of the building and
relatively poor site drainage, which allowed moisture to penetrate the
foundations soils; and
the construction of the property shortly after the end of a prolonged drought and
the resumption of normal rainfall conditions, following which volumetric changes
could be expected during the period of several years it took for the moisture
content of the soils to return to equilibrium.
FM concluded that the cracking and movement damage observed at the property
was not consistent with having been caused by the effects of water leaking from the
broken storm water pipes.
In particular, FM considered that the volumes of water passing through the
stormwater pipes during intermittent rainfall periods would not have been sufficient to
cause the extent of movement observed at the property.
FM noted that the soil moisture tests carried out by SS in March 2016 were at a
depth of 300 millimetres only and therefore were unlikely to be representative of the
condition of the soils underneath the waffle pod slab.
Damage was caused by naturally occurring earth movement
Having carefully reviewed the available information, the panel considers that the
proximate cause of the cracking and movement damage to the applicants’ property
was naturally occurring earth movement over an extended period of time.
While damaged storm water pipes were identified along the western boundary of the
property, the panel considers that the nature and location of the damage observed is
not consistent with it havi ng been caused predominantly by water leaking from these
pipes.
The floor level surveys carried out in by the FSP’s engineer (FM) in October 2015
and the applicants’ engineer (SS) in March 2016 support FM’s conclusion that the
leaks did not contribute to the bulk of the damage observed.
The pattern of differential movement at the property (as reflected in the contour
patterns derived from the floor level surveys) is generally consistent. While the level
surveys conducted by SS in March 2016 reflect different absolute measurements, the
contour patterns are generally similar.
The contour surveys indicate that there has been significant differential movement,
as between the relatively lower central area of the property and the relatively higher
areas around the perimeter (particularly at several of the corners).
While there is relative heave (upwards movement) in areas along the western side of
the property (adjacent to the leaking storm water pipes), significant heave is also
evident at the south-east corner of the property, which is further away from the
leaking pipes.
Relative upwards differential movement is particularly evident at three of the four
corners of the property, which would be expected to have greater exposure to
moisture from regular rainfall events.
Case No: 438364 Determination Page 5 of 6
While the applicants say the visible cracking and separation of the walls from the slab
is more pronounced in areas closer to the leaking pipes, the photographs included in
the engineers’ reports confirm that the damage is not limited to these area s.
Further, the level surveys carried out by both engineers confirm that movement has
occurred more broadly (regardless of the extent to which resultant damage may have
been triggered).
For the reasons outlined above, the panel considers the bulk of the damage to the
applicants’ property was caused by naturally occurring earth movement which
resulted in ‘edge heave’ of the concrete waffle pod slab.
The panel is not satisfied that the identified leaks to the neighbour’s storm water
pipes contributed to the cracking and movement damage at the property to any
significant extent.
The panel acknowledges that the applicants strongly disagree with FM’s findings and
consider she has relied on incorrect assumptions. Further, the applicants consider
that an independent engineer should be appointed to resolve the dispute.
T he applicants have identified concerns about some of the matters raised in FM’s
reports (including the characteristics of the tree located on the nature strip in front of
the property). However, even without having regard to the potentially drying effect of
this tree, there is sufficient information to establish that the claimed damage was
caused by naturally occurring earth movement.
While FOS has the power to appoint an independent expert (at th e FSP’s expense)
to provide advice where necessary, this approach is generally only adopted where
the FOS decision maker considers there is insufficient information to reach a
determination, rather than in every case where there are conflicting reports.
In the present case, the panel considers there is sufficient information available to
reach a view as to the proximate cause of the claimed damage. Accordingly, the
panel does not consider the appointment of an independent engineer is required.
FSP is not liable for applicants ’ claim
For the reasons outlined above, the panel considers that the cracking and movement
damage to the applicants ’ property was caused by naturally occurring earth
movement and not by the effects of water from the leaking pipes.
Damage caused in this manner is excluded from cover under the policy. Accordingly,
the FSP is not liable for the claimed damage.
Case No: 438364 Determination Page 6 of 6
3 Supporting information
3.1 FOS approach to this dispute
This dispute has not been the subject of a FOS recommendation. Due to the nature
of the dispute, it has been referred directly to a panel for determination, in line with
the Operational Guidelines to the FOS Terms of Reference. The panel consists of an
Ombudsman and two representatives with co nsumer and insurance experience.
The panel has decided this dispute based on what is fair in all the circumstances,
having regard to the relevant law, good industry practice, codes of practice and
previous Financial Ombudsman Service (FOS) decisions (whic h are not binding).
There has been a full exchange of all material information relied on for the purposes
of this determination and each party has had the opportunity to address any issues
raised by the other.
The panel has reviewed and considered all of the material provided by the parties.
While the parties have raised numerous issues in their submissions, for the purposes
of this determination, the panel has restricted its commentary to those issues that it
considers directly relevant to the outcome only.
During the course of this dispute, the applicants have been assisted by their legal
representative. For the purposes of this determination, submissions made by the
applicants’ legal representative have been treated as if they had been made by the
applicants themselves.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.