Home / Financial Firm (Unknown - Insurer) / Determination 438364

Determination 438364

Home cracking and movement damage claim denied under earth movement exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2017-04-21
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicants claimed for cracking and movement damage to their home, attributing it to leaking neighbouring stormwater pipes. The FSP denied the claim as excluded earth movement, and AFCA agreed the FSP is not liable.

The FSP showed the proximate cause was naturally occurring earth movement, which the policy excludes, rather than the leaking pipes.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 438364 Determination Page 1 of 6 Case number: 438364 21 April 2017 1 Overview 1.1 Dispute The applicants lodged a claim under their home insurance policy with the financial services provider (FSP) for cracking and movement damage to their property. The applicants consider the damage was caused by water leaking from cracked storm water pipes at their neighbour’s property. The FSP denied the claim on the basis that the damage was not caused by leaking pipes (or by any other event insured against under the policy) but by naturally occurring earth movement over a prolonged period of time, which is excluded from cover under the policy. 1.2 Issues and key findings Is the FSP liable for the damage to the applicants’ property ? The available information establishes that, on the balance of probabilities, the cracking and movement damage to the applicants ’ property was caused by naturally occurring earth movement. The nature and extent of the damage is not consistent with it having been caused by water leaking from the damaged storm water pipes at the neighbouring property. Damage caused by naturally occurring earth movement is not covered under the policy. Accordingly, the FSP is not liable for the applicants ’ claim. 1.3 Determination This determination is in favour of the FSP. The FSP is not liable for the damage to the applicants’ property . Case No: 438364 Determination Page 2 of 6 2 Reasons for determination 2.1 Is the FSP liable for the damage to the property? Policy provides cover for insured events subject to exclusions The applicants are required to show that, on the balance of probabilities, they have suffered a loss caused by a risk insured against under the policy. This is known as a valid (or prima facie ) claim. If the applicants are able to establish a prima facie claim, then the onus shifts to the FSP to show that, on the balance of probabilities, it is entitled to rely on an exclusion under the policy or is otherwise entitled to deny the claim. The applicants’ p olicy provides cover for damage caused by the events listed in the policy (including liquid leaking from a fixed pipe or drainage system), subject to the conditions and exclusions set out in the policy. Applicants have established a prima facie claim The available information establishes that damaged stormwater pipes were discovered at the applicants’ neighbour’s property in February 2015. Four separate sections of broken and blocked piping were identified in areas adjacent to the western boundary of the applicants’ property . Three of these sections were located towards the rear of the applicants ’ garage, while the fourth was near the front of the neighbouring garage. The reports prepared by the engineers appointed by the parties (SS and FM) confirm that the applicants’ property has suffered extensive cracking and movement damage. The applicants have advised that this damage commenced in around mid-2012, approximately twelve months after their house was built. In these circumstances, the panel is satisfied that the applicant has established a prima facie claim under the policy. Accordingly, the FSP bears the onus of establishing that, on the balance of probabilities, it is entitled to rely on a policy exclusion or is otherwise entitled to deny the applicant s’ claim. The FSP says it is not liable for the claimed damage because the leaking stormwater pipes did not cause the cracking and movement damage to the applicants ’ home. The FSP says the damage was caused by earth movement over an extended period of time, as a result of naturally occurring variations in the moisture content of the highly reactive clay foundation soils. The policy excludes cover for damage caused by subsidence, collapse, shrinkage or any other form of earth movement (other than landslide or subsidence which is specifically covered under certain insured events). In order to establish that it is entitled to deny the applicants ’ claim, the FSP must show that the proximate cause of the cracking and movement damage (that is, the Case No: 438364 Determination Page 3 of 6 real, effective or dominant cause) was naturally occurring earth movement (and not the effects of water leaking from the broken stormwater pipe). Engineers have provided differing opinions Both engineers appointed by the parties confirmed that the applicants ’ property was founded on highly reactive clay soils, which were susceptible to volumetric changes as a result of variations in moisture content. However, the engineers have provided differing opinions about what caused the cracking and movement damage which is the subject of the current claim . The applicants’ engineer (SS), who was originally appointed by the builder of the property, concluded that the damage had been caused by heave (upwards movement) as a result of the expansion of the foundation soils due to the effects of moisture from the leaking stormwater pipes. Following his initial inspection in February 2015, SS advised that:  floor levels taken at the property indicated movement in the footings of up to 55mm between the front and the rear of the garage and 35mm between the garage and the entry area to the east;  the building movement was concentrated towards the western part of the house;  he had observed water slowly filling up a hole excavated towards the rear of the applicants’ garage, which triggered an investigation of the neighbour’s storm water pipes; and  he considered the building movement was consistent with having been caused by the effects of water leaking from the pipes. SS subsequently conducted a further inspection in March 2016, during which he carried out level surveys of the entire house and undertook soil moisture testing, the results of which indicated that the soil had a higher moisture content in areas near the leaking stormwater pipes. SS reconfirmed his view that the leaking pipes had caused the damage. The FSP disputes that the damage was caused by the effects of water from the stormwater pipes, based on the findings of its engineer (FM), who inspected the property in October 2015. Based on the results of her floor level surveys, FM concluded that the pattern of differential movement at the property was more consistent with having been caused by ‘edge heave’ than by the leaking stormwater pipes. FM advised that ‘edge heave’ occurs where the perimeter of the slab is pushed upwards as the soils underneath it expand, due to being exposed to higher moisture conditions than the centre of the slab, which is less exposed to the elements. FM considered the applicants’ pr operty was particularly susceptible to edge heave due to factors including:  the use of a concrete waffle pod slab on a site with highly reactive clay soils, which has previously been associated with incidents of edge heave ; Case No: 438364 Determination Page 4 of 6  the presence of unpaved areas around the perimeter of the building and relatively poor site drainage, which allowed moisture to penetrate the foundations soils; and  the construction of the property shortly after the end of a prolonged drought and the resumption of normal rainfall conditions, following which volumetric changes could be expected during the period of several years it took for the moisture content of the soils to return to equilibrium. FM concluded that the cracking and movement damage observed at the property was not consistent with having been caused by the effects of water leaking from the broken storm water pipes. In particular, FM considered that the volumes of water passing through the stormwater pipes during intermittent rainfall periods would not have been sufficient to cause the extent of movement observed at the property. FM noted that the soil moisture tests carried out by SS in March 2016 were at a depth of 300 millimetres only and therefore were unlikely to be representative of the condition of the soils underneath the waffle pod slab. Damage was caused by naturally occurring earth movement Having carefully reviewed the available information, the panel considers that the proximate cause of the cracking and movement damage to the applicants’ property was naturally occurring earth movement over an extended period of time. While damaged storm water pipes were identified along the western boundary of the property, the panel considers that the nature and location of the damage observed is not consistent with it havi ng been caused predominantly by water leaking from these pipes. The floor level surveys carried out in by the FSP’s engineer (FM) in October 2015 and the applicants’ engineer (SS) in March 2016 support FM’s conclusion that the leaks did not contribute to the bulk of the damage observed. The pattern of differential movement at the property (as reflected in the contour patterns derived from the floor level surveys) is generally consistent. While the level surveys conducted by SS in March 2016 reflect different absolute measurements, the contour patterns are generally similar. The contour surveys indicate that there has been significant differential movement, as between the relatively lower central area of the property and the relatively higher areas around the perimeter (particularly at several of the corners). While there is relative heave (upwards movement) in areas along the western side of the property (adjacent to the leaking storm water pipes), significant heave is also evident at the south-east corner of the property, which is further away from the leaking pipes. Relative upwards differential movement is particularly evident at three of the four corners of the property, which would be expected to have greater exposure to moisture from regular rainfall events. Case No: 438364 Determination Page 5 of 6 While the applicants say the visible cracking and separation of the walls from the slab is more pronounced in areas closer to the leaking pipes, the photographs included in the engineers’ reports confirm that the damage is not limited to these area s. Further, the level surveys carried out by both engineers confirm that movement has occurred more broadly (regardless of the extent to which resultant damage may have been triggered). For the reasons outlined above, the panel considers the bulk of the damage to the applicants’ property was caused by naturally occurring earth movement which resulted in ‘edge heave’ of the concrete waffle pod slab. The panel is not satisfied that the identified leaks to the neighbour’s storm water pipes contributed to the cracking and movement damage at the property to any significant extent. The panel acknowledges that the applicants strongly disagree with FM’s findings and consider she has relied on incorrect assumptions. Further, the applicants consider that an independent engineer should be appointed to resolve the dispute. T he applicants have identified concerns about some of the matters raised in FM’s reports (including the characteristics of the tree located on the nature strip in front of the property). However, even without having regard to the potentially drying effect of this tree, there is sufficient information to establish that the claimed damage was caused by naturally occurring earth movement. While FOS has the power to appoint an independent expert (at th e FSP’s expense) to provide advice where necessary, this approach is generally only adopted where the FOS decision maker considers there is insufficient information to reach a determination, rather than in every case where there are conflicting reports. In the present case, the panel considers there is sufficient information available to reach a view as to the proximate cause of the claimed damage. Accordingly, the panel does not consider the appointment of an independent engineer is required. FSP is not liable for applicants ’ claim For the reasons outlined above, the panel considers that the cracking and movement damage to the applicants ’ property was caused by naturally occurring earth movement and not by the effects of water from the leaking pipes. Damage caused in this manner is excluded from cover under the policy. Accordingly, the FSP is not liable for the claimed damage. Case No: 438364 Determination Page 6 of 6 3 Supporting information 3.1 FOS approach to this dispute This dispute has not been the subject of a FOS recommendation. Due to the nature of the dispute, it has been referred directly to a panel for determination, in line with the Operational Guidelines to the FOS Terms of Reference. The panel consists of an Ombudsman and two representatives with co nsumer and insurance experience. The panel has decided this dispute based on what is fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous Financial Ombudsman Service (FOS) decisions (whic h are not binding). There has been a full exchange of all material information relied on for the purposes of this determination and each party has had the opportunity to address any issues raised by the other. The panel has reviewed and considered all of the material provided by the parties. While the parties have raised numerous issues in their submissions, for the purposes of this determination, the panel has restricted its commentary to those issues that it considers directly relevant to the outcome only. During the course of this dispute, the applicants have been assisted by their legal representative. For the purposes of this determination, submissions made by the applicants’ legal representative have been treated as if they had been made by the applicants themselves.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.