Home / Financial Firm (Unknown - Insurer) / Determination 438232
Determination 438232
claim_denial
Summary
The applicant claimed under his home policy for storm-related cracking caused by a defective roof truss. AFCA found the proximate cause was the truss's inadequate design, which the policy's design fault and structural defect exclusion covers, so the denial stands.
The proximate cause of the loss was a design fault, and the policy exclusion for design fault and structural defect applies despite the insured's lack of awareness.
Issues
- Claim denial primary · not upheld“The FSP is entitled to deny the applicant's claim under the terms and conditions of the policy.”
Subjects and remedies
home or building damagenatural disasterno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
Case No: 438232 Determination Page 1 of 6
Case number: 438232 7 March 2017
1 Overview
1.1 Dispute
This matter involves a claim by the applicant under his Home and Contents Insurance
Policy, held with the financial service provider (FSP), following damage to his home.
The FSP has denied the applicant’s claim on the basis that the cause of the damage is
excluded under the terms and conditions of the policy.
1.2 Issues and key findings
Is the FSP entitled to deny the applicant’s claim under the terms and conditions
of the policy?
The FSP is entitled to deny the applicant’s claim under the terms and conditions of the
policy.
1.3 Determination
This determination is in favour of the FSP.
The FSP is entitled to deny the applicant’s claim under the terms and conditions of the
policy.
Case No: 438232 Determination Page 2 of 6
2 Reasons for determination
This dispute has been the subject of a recommendation issued by the Service on 22
September 2016.
It was a case analyst ’s recommendation that the FSP was entitled to deny the
applicant’s claim as the proximate cause of the damage to the applicant’s property
was the defective truss.
The applicant has disputed the recommendation.
I have carefully considered all of the material provided both before and after the
recommendation in the preparation of this determination.
This determination follows consideration of all of the information exchanged and is
based on what is fair in the circumstances, having regard to the relevant legal
principles, terms of the policy, good industry practice and where applicable, prior
determinations.
2.1 Is the FSP entitled to deny the applicant’s claim on the basis of the
terms and conditions of the policy?
Coverage of the policy
The coverage provided by the applicant’s Home and Contents Insurance Policy is in
respect to loss and damage caused by insured events which are detailed within the
policy.
This means that not all loss and damage is automatically covered, but rather only loss
and damage caused by an insured event which is detailed within the policy.
The coverage provided by the policy is detailed within the Product Disclosure
Statement (PDS).
The PDS details:
…
…
Case No: 438232 Determination Page 3 of 6
The coverage is subject to exclusions which are also detailed within the PDS.
The PDS details:
…
It is accepted insurance law that the insured carries the initial onus to establish that he
has suffered loss and damage which is covered by the terms and conditions of the
policy.
The FSP’s onus to show the basis on which it otherwise seeks to deny the claim, only
arises once the applicant has established the loss and damage claimed is covered by
the terms and conditions of the policy.
As a result it is necessary to determine the proximate cause of the loss. The proximate
cause is the dominant or effective cause of the loss. It is no t necessarily the event last
in time.
Circumstances of the loss
The FSP have recorded that the applicant contacted it on 19 February 2016 to advise
that during a windy day in January the cornice in his living room had slipped down a bit
and since then a significant crack had developed across the living room and he had
looked in the roof and the beam/truss looked to be cracked.
The applicant advised that he heard a loud crack during the storm event.
The applicant says that the damage to his home is a result of the storm which is an
insured event under the terms and conditions of the policy.
The FSP engaged the engineering firm C to investigate and report on the cause of the
loss and damage at the applicant’s home.
C has provided a number of reports and on the basis of those reports the FSP has
denied the applicant’s claim.
C concluded that a truss within the roofing of the applicant’s home had not been
adequately designed and the damage to the home would not have occurred had the
truss been adequately designed.
Further, C confirmed its opinion that the wind had not caused any damage to the roof
trusses or damage to the residence interior.
Case No: 438232 Determination Page 4 of 6
As stated, C has provided a number of reports which are thorough and logical and the
conclusions are compelling.
The reports are supported by helpful photographs and diagrams.
The exchanged material does not include an alternative expert opinion to challenge
C’s conclusions.
Having considered all of the exchanged material I am satisfied that the FSP has
established that the proximate cause of the loss and damage is the inadequate design
of the truss and the FSP is entitled to rely upon its general exclusion for “design fault,
structural defect”, to deny the applicant’s claim.
Additional matters
The applicant says that he is entitled to rely upon section 46 of the Insurance
Contract’s Act 1984 (the Act), as pursuant to that section the insurer is still liable when
the insured is not aware of and a reasonable person in those circumstances is not
aware of the defect.
I do not agree with the applicant’s interpretation of section 46 of the Act.
It is settled insurance law that section 46 has the effect that where the insured was not
aware of the defect, the insurer may not rely upon an exclusion within the policy that
limits the insurer ’ s liability by reference to the defect existing before the contract of
insurance was entered into.
Noting that the exclusion relied upon by the FSP does not refer to the defect existing
prior to the contract of insurance being entered into, I am satisfied that the FSP is
entitled to rely upon the exclusion detailed above.
Having said that, I accept that there is no evidence to say that the applicant was aware
of the structural defect prior to the discovery of the loss and damage at the home.
Further, I am not satisfied that the building inspector ’s report is evidence that there
was no structural defect at the time of purchase of the property.
The fact that the applicant relied upon the content of the building inspector ’ s report
does not assist him in a claim against the FSP where the cause of the loss and
damage was a structural defect.
The applicant has provided a photograph of what appears to be the marking “B4” on a
wooden beam.
I do not accept that the photographic evidence of markings on the beam sufficiently
challenges the conclusions of the engineer C.
The evidence presented does not indicate when or where the photograph was taken
and of what particular beam. The applicant simply says that he “… did duck my head
in and…” took a photo of the B4 marking that he could see.
As stated, I consider the report of C to be thorough and logical and its conclusions are
compelling. As stated, the exchanged material does not include an alternative expert
opinion to challenge C’s conclusions.
Case No: 438232 Determination Page 5 of 6
Case No: 438232 Determination Page 6 of 6
Conclusion
Having reviewed all the exchanged material I am satisfied that the FSP is entitled to
deny the applicant’s claim on the basis of the exclusions detailed within the policy.
The FSP is not required to take any further action with regard to this matter.