Partial refusal of escape of liquid building claim under ground movement exclusion
Text of the determination
Determination
Case No: 436488 Determination Page 1 of 7
Case number: 436488 20 October 2017
1 Overview
1.1 Dispute
The applicants lodged a claim under their home building insurance policy with the
financial services provider (FSP), after they found a leak under their bathroom floor
on 3 December 2015. There was extensive damage throughout the bathroom,
adjacent laundry and subflooring.
The FSP accepted liability for part of the claim: that was for damage to the shower
cubicle and adjoining wall between the bathroom and laundry. It did not accept
liability for damage to the flooring, bearers and joists. It says the leak exacerbated a
pre-existing issue caused by differential soil movement, insufficient drainage and the
effect of nearby tree roots that would have required repair anyway.
The applicants maintain the claim should be paid in full, and ha ve provided an expert
report to support that.
1.2 Issues and key findings
Have the applicants established a claim under the policy?
The applicants have established a prima facie claim because:
water usage records indicate a significant escape of liquid event occurred
settlement occurred, consistent with saturation of highly silty soil the property
rests upon
each part ies’ engineering reports identified the escape of liquid as a cause of
loss.
Can the FSP deny or reduce its liability for the claim?
The FSP may not deny the claim. However, it is fair in all the circumstances that the
FSP reduce its liability by 25% because of the likely contribution to the loss by:
roots of trees near the affected area
lack of drainage local to the affected area
ongoing differential settlement prior to the escape of liquid event.
1.3 Determination
This determination is substantially in favour of the applicants. The FSP is required to
settle the claim by paying:
75% of an updated quote to be obtained by the applicants from their builder for
the scope of works outlined in the previously submitted 24 July 2016 quote
$3,000 towards the cost of the applicants’ engineer ’s report.
Case No: 436488 Determination Page 2 of 7
2 Reasons for determination
I have decided this case on the basis of what I consider fair in all the circumstances,
having regard to the relevant law, good industry practice, codes of practice and
previous FOS decisions.
I have taken into account all the material submitted by the parties. I am satisfied that
the documentation I have relied on has been provided to both parties. For the
purposes of this determination, I will deal with only those points considered relevant.
2.1 Have the applicants established a claim under the policy?
Applicants must show, on balance, the loss results from an escape of liquid
The applicants ’ policy provides cover for loss or damage arising from specific insured
events set out in the policy documents, subject to certain conditions and exclusions.
‘Escape of liquid’ is one of those insured events.
It is an accepted principle of insurance law that the applicants need to show, on the
balance of probabilities, the claimed loss results from an insured event under the
policy (a prima facie claim). If they can do so, the burden then shifts to the FSP to
show, on the balance of probabilities, that an exclusion applies or that it is otherwise
entitled to decline the claim.
Evidence submitted by each party indicates loss caused by escape of liquid
Each party relies on reports from their respective experts. A summary of those
findings is set out in section 3.1 of this determination.
The FSP’s engineer, F, in his first report, denied the escape of liquid could have
caused or contributed to the claimed damage. He did not conduct soil tests but
considered the foundation soils were reactive clay, based on the Geological Survey
of Victoria. Such soil responds to saturation by heave (lifting). The damage
complained of was due to settlement (fall). F said the settlement was caused by
trees close to the property removing moisture from the soil. This caused differential
footing settlement. His view was the property had been subject to long term
foundation movement and the leak would have caused heave, not settlement.
The applicants’ engineer, C, conducted soil sample tests and found the foundation
soils were silty, not clay. He says silty soil reacts differently to clay, losing its holding
capacity when wet. This means saturation causes subsidence rather than heave, and
the claimed damage is consistent with an escape of liquid. C’s report notes that the
sub-floor was saturated even though the region had experienced very dry conditions
in the five months prior to the inspection. It noted that the floor had moved gradually
at first, but the movement was more obvious in the last few months of 2015.
In his response to C’s report, F accepted the foundation soils were silty rather than
clay, and confirmed the escape of liquid would therefore have been a major
contributor to the recent settlement. F also said settlement had started significantly
prior to the water leak, and the bearers and joists under the laundry did not comply
with Australian Standards.
Case No: 436488 Determination Page 3 of 7
The applicants also presented their water usage records, indicating a very substantial
increase in water use during the period from August 2015 to December 2015.
On the available evidence, I am satisfied the water leak was a major contributor to
the damage claimed. That means the applicants have established a prima facie
claim.
2.2 Can the FSP deny or reduce its liability for the claim?
Physical evidence shows additional causes also contributed to the loss
In his first report, F noted several other factors which were likely to have caused the
subsidence:
poor site drainage including unpaved areas sloping back towards the property
medium sized trees located in close proximity to the property
the surface of the subfloor level was lower than the surface level of the
surrounding perimeter ground
bearers and joists to the laundry were supported on the ground and therefore
are not compliant with the Building Code of Australia
ongoing seasonal differential settlement confirmed by the floor level survey.
The level survey confirms there is movement throughout the whole property. C noted
the months preceding the claim were particularly dry. The dry weather, combined
with roots from the nearby trees, would drain moisture from the foundation soils and
cause subsidence.
F was of the opinion that movement was occurring in the bathroom and laundry
before the escape of liquid occurred, though it is unclear to what extent. C noted the
flooring apparently moved gradually at first but was more obvious in the last few
months of 2015.
The evidence shows there were multiple factors causing or contributing to the
claimed loss. So it is necessary to consider the proximate cause of the loss , to
determine the extent of the FSP’s liability under the policy .
Escape of liquid the dominant cause of loss
The proximate cause is not necessarily the first, last or the sole cause of the loss: it is
the effective, dominant or operative cause. Where several causes are operating
contemporaneously, if one cause would have caused the harm in any case, and the
other would not have done so in the absence of the first, the first is the proximate
cause.
It is clear there was some ongoing movement occurring prior to the escape of liquid,
due to the nearby trees and their roots, as well as the notably dry conditions. The
level survey of the property supports these conclusions.
However, on balance, I am satisfied the escape of liquid was the dominant cause of
damage because:
while there is otherwise ongoing movement throughout the property, it has not
manifested in the same manner as in the bathroom or laundry area
Case No: 436488 Determination Page 4 of 7
the silty soils respond strongly to saturation through subsidence, which is
consistent with the precise loss complained of by the applicants
none of the information presented indicates the loss would have occurred as
reported, if not for the escape of liquid.
In my view, the loss resulted as a consequence of the escape of liquid, worsened by
contributory factors identified by F set out in section 2.2. I note these factors are
mostly present for the remainder of the property, which has not suffered in the same
way. In the circumstances, I am satisfied it is more likely than not, the effective,
dominant, operative cause of the loss being claimed was the escape of liquid.
Exclusion for ground movement does not apply
The FSP relies on the general policy exclusion for ground movement to deny the
applicants’ claim for damage to the subflooring, stumps, bearers and joists.
The exclusion says the policy does not cover ‘ erosion, vibration, subsidence,
landslip, landslide, mudslide, collapse, shrinkage or any other earth movement ….’ .
For the reasons above, I am satisfied that the leak was the dominant cause of the
damage to the applicants’ laundry, bathroom and subflooring . It was the leak which
saturated the soil, leading to subsidence. The ground movement did not occur solely
as a result of naturally occurring changes in the moisture content of the soil, such as
seasonal rainfall. In that case the exclusion might reasonably apply. However, since
that is not the case here, the FSP cannot rely on the exclusion of ground movement
to entirely decline the claim.
FSP may reduce liability only to the extent excluded event contributed to loss
However, where an excluded event has contributed to a loss caused predominantly
by an insured event, then consideration should be given to reducing the FSP’s
liability for the loss to the extent of that contribution.
It will not always be possible to determine the extent of any such contribution
precisely. It is clear from the scope of works in this case, for example, that new
stumps are required and that the bearers and joists may require replacing. While it
may be the case that these do not comply with current Australian building standards
(as the FSP’s expert has suggested) and that this too has had an impact on the
damage, it is important to note that it has not been shown that any non-compliance
existed at the time of building, or that it would be fair in the circumstances to entirely
disregard the likely impact of the very significant water leak on that, as well as on the
remainder of the scope of works.
Under the circumstances, I consider it fair that the FSP be liable for 75% of the claim,
based on an updated quote to be obtained from the applicants ’ registered builder,
JR, and dealing with the same scope of works as set out in the original quote of 24
July 2016.
FSP must compensate the applicants for the cost of C’s report
The report prepared by C was an important element in determining a fair outcome for
this dispute. In particular, C conducted the soil sample tests confirming the
foundation soils were silty, rather than clay, as assumed by F. The difference in soil
Case No: 436488 Determination Page 5 of 7
type was a directly relevant consideration. The applicants have provided an invoice
for C’s report for $6,138.00.
In accordance with paragraph 9.4 of our Terms of Reference, FOS may direct an
FSP to reimburse the applicants for professional costs incurred where the costs
where necessarily incurred to ad vance the applicants’ position. Unless exceptional
circumstances apply, FOS would not require an FSP to contribute more than $3,000.
This is not a dispute where the exceptional circumstances exemption would apply.
It is fair and appropriate that the FSP reimburse the applicants $3,000 toward the
cost of C’s report.
Case No: 436488 Determination Page 6 of 7
3 Supporting information
3.1 Expert reports
Record Key points
FSP’s engineer ( F )
Engineering investigation
r eport
19 February 2016
Site presents with poor surface drainage due to presence of
unpaved ground sloping towards the residence.
Medium sized trees located 1 - 5m from residence, property within
their area of affect.
Mould and timber staining present indic ate long term leaks.
Floor level survey indicates subsidence occurring throughout th e
property.
Property assumed to rest upon reactive clay soils.
Movement patterns inconsistent with reactive clay soils.
Most significant cause of loss is the presence of nearby trees in
that area of influence .
Escape of liquid did not cause or contribute t o relative different
settlement of the property’s footings.
Applicant’s engineer ( C )
Engineering investigation
r eport
4 July 2016
Floor movement throughout the property gradually at first and at a
greater rate in the last few months of 2015 .
Subsidence in affected area clearly greater than mere foundation
settlement.
Very dry weather conditions in months preceding claim.
Soil samples taken, confirms soil is silty and not reactive clay.
Saturation of silty soil causes the loss of holding capacity, resulting
in the stumps subsiding. This kind of movement present at the
property.
‘ It is our professional opinion that the damage to the subject area
has resulted as a consequence of the enormous volume of water
leaking from a water supply pipe causing saturation and a
significant reduction in the load bearing strength of the foundation
soil ’ .
FSP’s engineer ( F )
Engineering investigation
report 2
24 August 2016
There was a leaking pipe present.
Cracking profiles indicate movement occurring since before the
escape of liquid event.
F accepts soil is silty and not reactive clay as previously stated.
F accepts the escape of wat er a major cont ributor to the recent
settlement, but is not the sole cause.
Bearers and joists under the laundry not compliant with Australian
S tandards.
F confirms the additional recent movement occurred due to leaking
water supply pipe in silty soils.
Case No: 436488 Determination Page 7 of 7
3.2 Relevant policy terms
Page Extract
22 Escape of liquid
We cover
Loss or damage to the building caused by liquid leaking, overflowing
or bursting from any of the following: …
any drain, fixed pipes, roof gutters or guttering and rainwater
downpipes and sewage systems …
37 We do not cover – general exclusions
Ground movement
erosion, vibration, subsidence, landslip, landslide, mudslide, coll apse,
shrinkage or any other earth move me nt …
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.