Home / Financial Firm (Unknown - Insurer) / Determination 434033
Determination 434033
Escape of liquid claim denied for gradual leak from stormwater pipe
Summary
The applicant's claim for subsidence from a leaking stormwater pipe was denied as the water escape was gradual, not sudden and unexpected. AFCA found in the FSP's favour, noting poor claim updates, and ordered no payment.
Cover for escape of liquid requires a sudden and unexpected escape, and the expert evidence showed the subsidence developed gradually over time.
Issues
- Claim denial primary · not upheld“I am not satisfied on the balance of probabilities that the damage was caused by the sudden and unexpected escape of liquid within the terms of cover”
- Failure to disclose secondary · not upheld“I am satisfied the FSP sent the relevant PDS to the applicants last known address as required under Section 72A”
- Poor communication secondary · upheld“The FSP did not however keep the applicant informed as to the progress of the claim in accordance with the relevant General Insurance Code of Practice.”
Subjects and remedies
home or building damageno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
Case No: 434033 Determination Page 1 of 7
Case number: 434033 7 February 2017
1 Overview
1.1 Dispute
The applicant lodged a claim with the financial services provider (FSP) for damage to
his home after discovering a leaking pipe at his property. The FSP arranged for a
builder and an engineer to inspect the damage and after considering their reports
together with the terms of the policy, it denied liability for the applicant’s claim.
The applicant disagrees with the FSP’s decision and say s:
the conclusions reached and information provided by the FSP’s engineer were
incorrect
the FSP did not provide him with the current policy documents
the claim process was inexcusably slow and delayed.
1.2 Issues and key findings
Did the FSP provide the 2013 Policy (PDS) to the applicant?
The FSP can rely on the terms and conditions of the 2013 PDS as it has established,
on the balance of probabilities, that it provided the applicant a copy of the 2013 PDS
together with his renewal documentation in December 2013.
Is the FSP entitled to deny the applicant’s claim ?
The FSP is entitled to deny the claim because:
cover for damage caused by ‘escape of liquid’ is only available where the
escape is sudden and unexpected
damage caused by gradual escape of liquid is e xcluded from cover.
Is the applicant entitled to any other compensation?
The applicant is not entitled to any other compensation.
1.3 Determination
This Determination is in favour of the FSP
The FSP is entitled to deny the applicant’s claim
Case No: 434033 Determination Page 2 of 7
2 Reasons for determination
There has been a full exchange of material between the parties and each party has
had the opportunity of addressing the issues that arise from the information
exchanged.
A recommendation was issued in this dispute that was in favour of the FSP. The
applicant has rejected that recommendation. In rejecting the recommendation the
applicant has made further submissions as to the circumstances of the claim and the
application of the policy. Those submissions have been taken into account in
reaching this determination.
This determination follows consideration of all of the information available and is
based on what is fair in all the circumstances, having regard to the relevant legal
principles, terms of the policy, good industry practice including codes of practice and
prior determinations where applicable.
2.1 Did the FSP provide the applicant with the 2013 PDS
The applicant disputes receiving the 2013 PDS and maintains in these circumstances
the FSP must rely upon the wording of the original PDS from 2007.
The FSP has provided details of its production and mailing processes, supported by
a statutory declaration from its Underwriting Manager which sets out the documents
and dispatch procedures which are managed by its mailing house.
The procedures show that a number of documents were required to be included with
the applicant’s renewal and that for that relevant day these procedures were
completed fully by 23 December 2013 for the renewal on 17 January 2014.
Although the applicant says that he did not received the PDS, or cannot recall
receiving it, it appears more likely than not that the PDS was included with the
renewal schedule and payment details, and dispatched to the applicant’s correct
mailing address.
I am satisfied the FSP sent the relevant PDS to the applicants last known address as
required under Section 72A of the Insurance Contracts Act 1984 (the Act). I am
satisfied the FSP has met its obligation to clearly inform the applicant of the terms
applicable to his cover as from 17 January 2014.
2.2 Is the FSP entitled to deny the applicant’s claim?
The policy provides cover for ‘escape of liquid’ in certain circumstances.
The applicant’s policy provides cover for loss or damage arising out of any of the
insured events listed in the policy documents. Each event is subject to certain
conditions and exclusions.
Relevantly, in this instance the insured event states:
Case No: 434033 Determination Page 3 of 7
‘ What is covered
Your building and/or contents are covered for loss or damage caused by a sudden and
unexpected escape of liquid from any:
Fixed wat er pipe
…
What is not covered
You are not covered under this Insured Event for:
loss or damage caus ed by any escape of liquid of which you were aware and failed to
notify us within a reasonable period;
…
loss or damage caus ed by any gradual escape of liquid; ’
There is some inconsistency in the information provided as to when the applicant first
noticed the leaking pipe. The reports from the FSP’s builder and engineer suggest it
was first noticed in June/July 2014. The reports suggest the original builder referred
the applicant to the insurer. The applicant maintains he first noticed a leaking pipe in
the sub floor of his home under the deck area in late June/early July 2015. The
applicant has provided photographs taken in August 2015 showing the damaged
pipe.
Subsequent photos taken by the FSP’s engineer on 22 December 2015 show the
pipe taped. The applicant confirms he taped the pipe to prevent the leak.
Damage a result of water leaking from storm water pipe.
The applicants claim is that the damage arose from the sudden escape of water from
the storm water pipe. Due to the issues involved the FSP arranged for a builder and
engineer to attend the property to inspect the damage.
Builder’s report
The builder (AB) attended the property on 5 November 2015. He found that there
was a sagging of the structure, the steel stumps were severely rusted and the
concrete perimeter had sunk. He noted a cracked, suspended stormwater pipe in the
sub-floor, which had been temporarily repaired with duct tape. He considered the
damage was consistent with on-going water entry into the soil and recommended the
appointment of an engineer.
Engineer’s report
Engineer GE attended the property on 22 December 2015. GE confirmed that the
subsidence in the area had occurred as a result of water leaking from the stormwater
pipe, which was also responsible for the rusted steel stumps.
No evidence that damage caused by sudden and unexpected escape of liquid
The applicant has challenged some of the statements made by the builder and the
engineer with respect statements attributed to him, which he denies making, and
some of the findings of the engineer.
Case No: 434033 Determination Page 4 of 7
However, what is not disputed is that the suspended stormwater pipe had cracked
and this has led to water being discharged into the ground causing subsidence
damage and rusting of the steel stumps.
The FSP believes the split pipe may have been leaking into the ground for up to 18
months (knowledge of which the applicant denies). It had been cracked and
commenced leaking at least 5 months before a professional repair was carried out.
The temporary application of duct tape is likely to have been relatively ineffective as
a solution.
The FSP submits that the escape of water over a period of time does not meet the
threshold requirement of the in sured event, being ‘… a sudden and unexpected
escape of liquid.’ The applicant disputes that saying that this would have been a
major and rapid escape at the times when there is significant rainfall at the location,
which is uncommon.
I have considered thi s argument and in the absence of a definition for ‘sudden’ in the
policy I must rely on the ordinary meaning of the word. The Macquarie Dictionary
defines sudden as ‘1. happening, coming, made or done quickly, without warning or
unexpectedly.’
I am satisfied that water has escaped from the cracked pipe over a period of time,
although the actual period cannot be determined. I am mindful of the expert evidence
which indicates that a single inundation of water is unlikely to have led to subsidence,
and further that the noted rusting of the steel stumps is more likely to have developed
over a longer period of time. These conclusions are not refuted by any alternative
expert evidence. I have also looked at the relevant weather data. There does not
appear to be any unusual weather event that could be said to have led to a sudden
escape of water sufficient to cause the damage.
I am not satisfied on the balance of probabilities that the damage was caused by the
sudden and unexpected escape of liquid within the terms of cover under the policy.
Other issues do not assist the applicant
The applicant has challenged some of the statements made by the FSP’s experts,
and as such says the FSP cannot rely on its exclusions.
As no prima facie claim has been established, the FSP is not required to prove its
exclusions, however for the sake of completeness I will deal with a number of those
issues.
The insured event of escape of liquid includes an exclusion noted above, that is,
damage caused by a gradual escape of liquid. Again, in the absence of a policy
definition, the Macquarie Dictionary defines this as ‘1. Taking place, changing,
moving etc. by degrees or little by little’. Based on the expert evidence, it is unlikely
that the subsidence of the building would have occurred as a result of a single event
of escape of liquid, but rather would be a gradual process occurring over a period of
time.
The FSP has included a number of other exclusions in its denial, including failure to
notify the FSP in a timely manner, defect and non-compliance. This appears to be a
Case No: 434033 Determination Page 5 of 7
scatter-gun approach to denial and I am not persuaded that the FSP has established
these exclusions. In any event these are no longer relevant.
The applicant has also claimed for ‘Accidental Damage’ which provides a broader
cover, However this does not assist the applicant as this event excludes accidental
damage where the relevant event is provided or excluded under another insured
event, in this instance escape of liquid. In any event, the policy contains a general
exclusion concerning damage caused by ‘water including rainwater after it has
disappeared beneath the surface of the land…’
2.3 Is the applicant entitled to compensation?
No compensation is payable
Under paragraph 9.3 of the Terms of Reference compensation for non-financial loss
of up to $3,000 may be awarded in circumstances where an applicant experiences
an unusual degree of time taken or inconvenience when dealing with a claim.
Having reviewed the chronology of the claim, I am not satisfied that the FSP’s
handling of the claim was such that it unusually delayed the process, or that the time
taken to undertake inspections by the builder and the engineer were excessive.
Whilst there is dispute as to when the applicant first notified the FSP, the FSP’s claim
notes indicate that the claim was first lodged on 5 November 2015. I accept at that
time the FSP acted reasonably by appointing a builder to attend the property on the
same day.
The FSP did not however keep the applicant informed as to the progress of the claim
in accordance with the relevant General Insurance Code of Practice. The claim notes
do not reveal any contact with the applicant between 5 November 2015 and
15 December 2015. There was further delay from when the FSP received the
engineering report until it notified the applicant of its decision. The FSP has not
provided any explanation as to why it did not keep the applicant informed about the
progress of his claim. I accept that the FSP should have contacted the applicant
earlier.
The applicant has complained that he expended a significant amount of his own time
in pursuing his claim although he has provided no evidence as to the actual amount
of time spent.
Whilst I accept that the FSP did not keep the applicant informed I am not satisfied
that the applicant has established an entitlement to compensation. The claim was
properly investigated and relevant expert reports obtained with the final decision
made in February 2016. I am not satisfied that the failure by the FSP to keep the
applicant informed resulted, in this instance, in an unusual degree of time taken or
inconvenience suffered by the applicant.
I note the FSP had offered the applicant an ex gratia payment in this matter of
$3,000. The applicant elected not to accept this. The FSP has now withdrawn that
offer. Should the FSP wish to reinstate that offer then that is a matter between the
applicant and the FSP.
Case No: 434033 Determination Page 6 of 7
3 Supporting information
3.1 Policy terms
‘ Escape of liquid
What is not covered
You are not covered under this Insured E vent for:
loss or damage caus ed by any escape of liquid of which you were aware and failed to notify us
within a reasonable period;
…
loss or damage caus ed by any gradual escape of liquid;
Accidental damage
…
If the cause of the loss or damage falls under an Insured Event in the policy, the loss or damage will
be assessed under that Insured Event.
General Exclusions
Under this policy there is no cover provided for any loss, damage or liability caused directly or
indirectly by or in any way connected with:
1. defects, structural or design faults, faulty workmanship or faulty design;
2. damage to your building or part of your building that at the time it was built, renovated or installed
was not compliant with the relevant local government regulations, or the requir ements of any other
statutory authority;
3. …
4. wear and tear and lack of maint enance, including rust, corrosion and deterioration (except in some
instances relating to the Insured Events ‘Escape of liquid’ and ‘Legal liability’ claims);
5. …
8. subsidence or landslide;
9. the vibration, settling, shrinking or expanding of earth or any building foundation, wall, pavement
or pat h
10. erosion that occurs gradually…’
3.2 Expert reports
Record Key points
FSP’s engineer ( G E )
Water Damage Structural
Assessment
11 - 01 - 2016
Soil probe test conducted around house found to be consistent and
dry, but wet and soft around subfloor entry.
Roof drainage appeared adequate and functioning well.
The sub - floor and perimeter drain to the creek.
Ground movement is evident around the subfloor access.
Noticeable subsidence along the path near the veranda entrance.
Subfloor access door slightly distorted due to movement.
The subfloor ground appears to be freely draining, ie any water
entering the subfloor space is managing to drain to the exit pipes.
The exit pipes are necessary because the perimet er concrete
paths are higher than the subfloor.
Case No: 434033 Determination Page 7 of 7
There are visible sags and hogs between supports in the pipe.
‘In my opinion, water from the recent pipe leak has contributed to
the subsidence’.
Current suspended pipe hangar supports spaced 2m apart are
inadequate. AS 2032:2006 provides the maximum support spacing
for a pipe of this kind is 1.5m.
‘I believe lack of adequate supports to be a contributing fac tor to
the leaking suspended pipe bend’.
Subfloor drainage exit pipes are installed because perimeter
concrete path is higher than the subfloor surface, which is not
permitted by the Building Code of Australia for a suspended floor.
Observed subsidence has resulted from the leak.
FSP ’s builder ( A B )
Preliminary Report
05 - 11 - 2015
Slight sag noted in the timber deck located above the leaking pipe.
Movement associated with the timber deck and concrete pat h
consistent with ongoing wat er escape in the subfloor v oid space.
The steel stumps are highly rusted as wat er is unable to drain
away.
Unclear whether the present of the nearby creek contributed to
loss.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.