Denial of investment property bathroom flooring water damage claim as gradual deterioration
Text of the determination
Determination
Case No: 432634 Determination Page 1 of 7
Case number: 432634 14 March 2017
1 Overview
1.1 Dispute
The applicant lodged a claim under his landlord insurance policy with the financial
services provider (FSP) for water damage to the flooring in the bathroom and shower
area at his investment property. The applicant says this damage was caused by a
leaking pipe under the laundry.
The FSP denied the claim on the basis that the damage was not caused by the
leaking pipe but by factors which are excluded under the policy (namely, the gradual
deterioration of the flooring over time).
The applicant disputes the FSP’s position and seeks cover for the damage to the
flooring. He also says the FSP has provided conflicting advice and has unreasonab ly
delayed the resolution of his claim, causing him to suffer further losses .
1.2 Issues and key findings
Is the FSP liable for the damage to the flooring?
The FSP is not liable for the damage to the flooring as the available information
establishes that the damage was caused by gradual deterioration over an extended
period of time, in the course of ordinary use. Damage caused in this manner is
excluded from cover under the policy.
Is the applicant entitled to any other amounts?
The applicant is not entitled to benefits for loss of rent under the policy as the
damage was not caused by an insured event. Further, the circumstances of the claim
are not such as to justify the award of compensation.
1.3 Determination
This determination is in favour of the FSP.
The FSP is not liable for the applicant’s claim .
Case No: 432634 Determination Page 2 of 7
2 Reasons for determination
2.1 Is the FSP liable for the damage to the flooring?
Policy provides cover for escape of liquid subject to exclusions
The applicant is required to show, on the balance of probabilities, he has suffered a
loss caused by a risk insured against under the policy. This is known as a valid (or
prima facie ) claim.
If the applicant is able to establish a prima facie claim, then the onus shifts to the
FSP to show, on the balance of probabilities, it is entitled to rely on an exclusion
under the policy or is otherwise entitled to deny the claim.
The applicant’s policy provides cover for loss or damage caused by the events listed
in the policy (including the insured event of ‘ escape of liquid ’), subject to the
conditions and exclusions set out in the policy.
The insured event of ‘escape of liquid’ provide s cover for damage caused by liquid
leaking, overflowing or bursting from certain items, including fixed pipes, baths and
basins.
However, the policy also contains a general exclusion for damage caused by, arising
from or involving gradual deterioration, wear, tear, corrosion or rot.
FSP’s liability depends on cause of damage
The FSP does not dispute that the flooring at the applicant’s investment property has
suffered water damage. The reports prepared by the FSP’s contractors confirm that
the flooring is ‘spongy’ and shows signs of significant sagging and deflection.
The applicant says the damage was caused by the effects of water from a leaking
pipe located underneath the laundry. The applicant’s plumber identified and replaced
a burst T joint in the pipe shortly after the claim was lodged.
However, the FSP says it is not liable for the damage to the flooring because this
damage was not caused by the leaking pipe, but by the gradual deterioration of the
flooring over an extended period of time.
Accordingly, in order to determine whether the FSP is liable for the claim, it is
necessary to identify the proximate cause of the damage (that is the real, effective of
dominant cause).
FSP’s contractors have provided conflicting opinions
After the applicant lodged his claim, the FSP appointed an assessor (B) and a builder
(A) to inspect the damage. The assessor and builder attended the property on
5 November 2015, at the same time as the applicant’s plumber.
The assessor (A) confirmed that the particle board flooring under the vinyl floor
covering in the affected areas was waterlogged and soggy. However, in her report,
the assessor did not express an opinion as to the cause of the damage.
Case No: 432634 Determination Page 3 of 7
In his report, the FSP’s builder (A) concluded that the burst water pipe had been
leaking for some time, flooding the area underneath the bathroom and causing the
observed damage to the particle board flooring.
Due to the period of time over which the damage had occurred, the assessor was
concerned about the potential for structural damage to the property. Accordingly, the
FSP appointed an engineer (F) to carry out an inspection.
In his report dated 21 December 2015, F disagreed with the findings of the FSP’s
builder (A) that the damage to the particle board flooring had been caused by the
leaking pipe.
F noted that the location of the leak (under the laundry) meant that the leaking water
would flow along the surface of the sub-soil underneath the house and pool
underneath the bedrooms. He considered that the pooling water would not affect the
flooring in the bathroom and shower room.
F advised that the particle board flooring in these areas had gradually deteriorated
over its lifetime, as would be expected in the ordinary course of events, having
regard to the age of the building (40 years old) and the manner in which it was
constructed. In particular, F noted that:
while the use of non-moisture resistant particle board in wet areas was common
when the property was built, this kind of flooring was susceptible to moisture
expansion and discoloration, particularly if not covered by paint or another type
of sealant; and
the joint filler used to waterproof the edges of the vinyl material covering the
particle board was unsuitable for that purpose, and had contributed to the
deterioration of the particle board flooring by allowing water to enter.
Damage was caused by gradual deterioration
Having carefully reviewed the available information, I am satisfied that, on the
balance of probabilities, the proximate cause of the damage to the flooring was
gradual deterioration over an extended period of time, and no t the effects of the
leaking pipe under the laundry identified in November 2015.
I am satisfied that, as an engineer, F is appropriately qualified to determine the cause
of the damage to the flooring. F’s report provides a logical and rational explanation as
to how the damage occurred, which is consistent with the observed facts.
In particular, I note that:
based on the photographs provided, the damage appears worse in the areas
which are directly adjacent to the bath, shower and vanity unit. This is
consistent with water having penetrated the flooring in these areas during
periods of ordinary usage;
while the applicant considers the damage was caused by moisture pooled on
the sub-soil being absorbed into the particle board , this appears unlikely given
the distance between the flooring and the sub-floor soils; and
the nature of the damage to the particle board flooring appears more consistent
with it having been caused by water leaking directly through the waterproofed
Case No: 432634 Determination Page 4 of 7
areas onto the upper surface of the flooring, rather than as a result of the
moisture having been absorbed from below.
Circumstances do not preclude FSP from relying on F’s report
The applicant says it is not appropriate to allow the FSP to rely on the findings in F’s
report because:
the FSP’s assessor (B) and builder (A) had already concluded that the damage
had been caused by the leaking pipe, prior to F’s appointment;
F was appointed for the sole purpose of identifying whether there was any
structural damage to the property, and not to revisit A ’s findings as to the cause
of damage; and
F did not attend the property until after the leaking pipe had been repaired.
I accept that the FSP’s contractors initially concluded that the damage had been
caused by the leaking pipe (which would suggest that it was subject to cover under
the policy). However, this does not of itself preclude the FSP from relying on F’s
subsequent report.
The report provided by the builder (A) is relatively brief and does not clearly explain
the basis on which he concluded that the damage to the flooring had been caused by
the leaking pipe.
In contrast, F’s report includes a thorough consideration of the potential effects of the
leaking pipe and a detailed explanation of the reasons for his conclusion that the
damage was caused by other factors.
Further, while the pipe had been repaired by the time F attended the property, I am
satisfied that he was provided with sufficient information about the nature of the leak
for the purpose of forming his views.
Finally, while F may have been appointed solely to investigate structural damage, his
report was not limited in this regard. Accordingly, it is reasonable for the FSP to rely
on his conclusions.
FSP is not liable for damage to flooring
For the reasons outlined above, I am satisfied that the damage to the flooring was
caused by the gradual deterioration of the flooring over an extended peiod of time, in
the course of ordinary usage.
Damage caused in this manner is excluded from cover under the policy. Accordingly,
t he FSP is not liable for the applicant’s claim.
2.2 Is the applicant entitled to any additional amounts?
Benefits for loss of rent are not payable under the policy
The applicant seeks compensation for loss of rent. While only limited information has
been provi ded, it appears the applicant’s tenant requested a rent reduction as a
result of being unable to use the bathroom.
Case No: 432634 Determination Page 5 of 7
Under the terms of the policy, benefits for loss of rent are payable where the property
becomes unable to be lived in as the result of damage caused by an insured event.
In the present case, the damage to the property was not caused by an insured event,
but by factors which are excluded from cover under the policy.
Accordingly, the applicant is not entitled to benefits for loss of rent.
FOS may award compensation for financial and non-financial losses
Under the Terms of Reference, FOS may award compensation (capped at $3,300)
for consequential financial loss suffered by an applicant in connection with their
claim.
In addition, FOS may award compensation (capped at $3,000) for non-financial loss
where an applicant has suffered an unusual degree or extent of physical
inconvenience, time taken to resolve the situation or interference with their
expectation of enjoyment or peace of mind.
However, FOS adopts a conservative approach to the award of compensation for
non-financial loss. FOS expects applicants to be moderately robust and bear the
usual stress and inconvenience associated with an insurance claim.
Circumstances do not justify award of compensation
The applicant is dissatisfied with the manner in which the FSP handled his claim. In
particular, he says the FSP’s contractors provided conflicting information and the
FSP unduly delayed finalising his claim.
I accept that the views of th e FSP’s initial contractors as to the cause of damage
differed from the conclusions subsequently reached by its engineer (F). I also
acknowledge that the applicant would have been understandably concerned by these
conflicting opinions.
However, I am not satisfied that the FSP has acted unreasonably in the
circumstances. The FSP acted appropriately in appointing an engineer when its
assessor raised concerns about structural damage. Once the engineer’s report had
been received, the FSP was entitled to rely on its findings.
Further, I am not satisfied that the applicant has suffered any loss as a result of
acting to his detriment in reliance on the initial advice provided by the FSP’s
contractors, in circumstances where it was reasonable to do so.
The FSP did not formally advise the applicant of the outcome of his claim until after it
had received and reviewed the engineer’s report (following which it notified the
applicant in writing that his claim had been denied). Accordingly, prior to this date,
the claim remained open.
Further, while it took approximately three months to finalise the claim, this period was
not unreasonable, in circumstances which required the appointment of more than
one expert and which included the Christmas/New Year period.
For the reasons outlined above, while I accept that the applicant has experienced
some delay and inconvenience as a result of the manner in which the FSP handled
Case No: 432634 Determination Page 6 of 7
his claim, I do not consider the circumstances are such as to justify the award of
compensation.
Case No: 432634 Determination Page 7 of 7
3 Supporting information
3.1 FOS approach to this dispute
This dispute was the subject of a FOS recommendation issued on 21 October 2016.
The recommendation was rejected by the applicant.
This dispute has been determined based on what is fair in all the circumstances,
having regard to the relevant law, good industry practice, codes of practice and
previous FOS decisions (which are not binding).
There has been a full exchange of all material information relied on for the purposes
of this determination and each party has had the opportunity to address any issues
raised by the other. All of the material provided by the parties has been reviewed and
considered.
While the parties have raised numerous issues in their submissions, for the purposes
of this determination, commentary has been restricted to those issues which are
considered directly relevant to the outcome only.
3.2 Terms of policy
Subject Te rms
Escape of liquid We cover
Loss or damage caused by liquid leaking, overflowing or bursting
from any of the following: …
any drain, fixed pipes, roof gutters or guttering and rainwater
downpipes, drainage and sewage systems …
baths, sinks, toilets and basins …
General exclusions You are not covered under any section of this policy for damage,
loss, cost or legal liability that is caused by, arises from or involves:
Wear, tear and gradual deterioration
wear, tear, rust, fading, rising damp, mould, mildew, corrosion, rot,
action of light, atmospheric or climatic conditions or gradual
deterioration …
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.