Text of the determination
Determination
Case No: 421271 Determination Page 1 of 6
Case number: 421271 14 November 2016
1 Overview
1.1 Dispute
In July 2015, the applicants lodged a claim under their home insurance policy with
the financial services provider (FSP), for cracking and movement damage to a corner
of their home.
The applicants consider the damage was caused by a leaking pipe, which was
discovered by their underpinning contractor in the course of completing works at the
property.
The FSP denied the claim on the basis that the cracking and movement damage was
not caused by leaking pipes (or any other event insured against under the policy), but
by naturally occurring earth movement, which is excluded from cover under the
policy.
1.2 Issue and key findings
Is the FSP liable for the damage to the property?
The available information establishes that, on the balance of probabilities, the
cracking and movement damage to the applicants’ property was caused by naturally
occurring earth movement and not by the effects of water leaking from the broken
stormwater pipe.
Damage caused in this manner is excluded from cover under the policy.
1.3 Determination
This determination is in favour of the FSP.
The FSP is not liable for the applicants’ claim .
Case No: 421271 Determination Page 2 of 6
2 Reasons for determination
2.1 Is the FSP liable for the damage to the property?
Property provides cover for insured events subject to exclusions
The applicants are required to show that, on the balance of probabilities, they have
suffered a loss caused by a risk insured against under the policy. This is known as a
prima facie claim.
If the applicants are able to establish a prima facie claim, then the onus shifts to the
FSP to show that, on the balance of probabilities, it is entitled to rely on an exclusion
under the policy or is otherwise entitled to deny the claim.
The applicants ’ policy provides cover for damage caused by the insured events listed
in the policy (including liquid leaking from a fixed pipe or drainage system), subject to
the conditions and exclusions set out in the policy.
Applicants have established a prima facie claim
The reports prepared by the various contractors who inspected the applicants’
property confirm that there is extensive cracking to the internal brickwork at the
south-west corner of the property, as well as internal cracking to wall and ceiling
linings.
The applicants say they first noticed the cracking damage in late 2014 and sought
advice from a structural engineer (AC), when the cracking worsened in early 2015.
AC advised the applicants that the front corner of the house had sunk and
recommended underpinning works to raise this area.
During the course of these works, the underpinning contractor (AL) identified a
leaking earthenware stormwater pipe in the immediate vicinity of the damaged area.
The applicants engaged a plumber who replaced the pipe, following which the
underpinning works were completed by AL.
The applicants have provided a copy of a short report from their plumber confirming
the leak, together with photographs showing water pooling in the trenches dug for the
purpose of the underpinning works.
In these circumstances, I am satisfied that the applicants have established a prima
facie claim under the policy.
Accordingly, the FSP bears the onus of establishing that, on the balance of
probabilities, it is entitled to rely on a policy exclusion or is otherwise entitled to deny
the applicants ’ claim.
The FSP says it is not liable for the claimed damage because the leaking stormwater
pipe did not cause the cracking and movement damage to the applican ts’ home.
The FSP says the damage was caused by earth movement over an extended period
of time, as a result of naturally occurring variations in the moisture content of the
surrounding soils.
Case No: 421271 Determination Page 3 of 6
The policy excludes cover for damage caused by erosion, subsidence, collapse,
shrinkage or any other earth movement (other than landslide or subsidence that is
specifically covered under certain insured events).
Accordingly, i n order to establish that it is entitled to deny the applicants’ claim, the
FSP must show that the proximate cause of the cracking and movement damage
(that is, the real, effective or dominant cause) was naturally occurring earth
movement.
Consultants have provided conflicting opinions
The various consultants engaged by the parties to determine the cause of the
damage have provided conflicting opinions as to the mechanism by which the
damage occurred.
The applicants’ structural engineer (AC) provided a brief report, in which he
concluded that the water leaking from the broken pipe had contributed significantly to
the damage to the south-west corner of the building.
In his report, AC stated that the water from the pipe could have flowed into the
surrounding soil and through the upper layer of silty fill material (which had a
relatively high hydraulic conductivity), leading to a build-up of perched water above
the lower layer of reactive clay soil.
AC considered that the perched water could decrease the bearing capacity of the soil
supporting the building footing to a certain degree. AC confirmed that, when the soil
does not have enough bearing capacity, the footing would move and the building
would sink and crack.
In contrast, the FSP’s engineer (FM) concluded that the damage had been caused by
naturally occurring earth movement over a period of time due to the combined effects
of long term variations in the moisture content of the foundation soils, due to factors
including climatic weather patterns and the drying conditions of nearby trees.
FM considered that the nature of the damage was not consistent with it having been
caused by the leaking pipe, as the effect of water on highly reactive clay soils (such
as those at the property) is to cause heave (upwards movement), rather than the
settlement (downwards movement) observed at the applicants ’ property.
The FSP initially denied the applicants’ claim based on FM’s findings as to the cause
of the damage. However, after the applicants disputed the denial, the FSP’s internal
dispute resolution (IDR) department recommended that soil tests be arranged to
assist in identifying the cause of the damage to the home.
The purpose of carrying out the soil tests was to determine whether the nature of the
soils was such that a bearing failure of the soil could have occurred as a result of the
water leak.
The FSP appointed a geological consultant (MG) who carried out soil tests in
October 2015, which confirmed that the soil at the property comprised a silty layer of
top soil over highly reactive clay soils.
Case No: 421271 Determination Page 4 of 6
MG’s tests also identified that soil samples taken in the area of the leaking pipe had
double the moisture content of samples taken elsewhere on the property (despite the
pipe having been repaired several months earlier).
In his report, MG provided his own opinion as to the cause of the cracking and
movement damage. MG considered that the damage had been caused by changes
in the moisture content of the reactive clay soils, causing the soils to swell and
resulting in the lifting and rotation of the footing in the front corner.
Damage is not consistent with having been caused by leaking pipe
As outlined above, both the engineers (AC and FM) and the geological consultant
(MG) engaged by the parties have provided differing opinions as to how the cracking
and movement damage occurred.
The applicants note that both AC and MG concluded that the leaking pipe had
caused (or significantly contributed to) the claimed damage.
However, the fact that AC and MG reached the same conclusion cannot be given any
substantial weight, in circumstances where their findings about the damage
mechanism directly contradicted each other.
AC concluded that the damage had been caused by a loss of bearing capacity in the
foundation soils (that is, the inability of the soils to support the building above,
resulting in downwards movement). By contrast, MG found that the leaking water had
caused the soils to swell, causing upwards movement in the building above.
MG’s finding that there was swelling of the soils and upwards movement of the
property is not consistent with the plans prepa red by the applicants’ underpinning
contractor, which indicates that the front corner of the property had sunk.
On this basis, I am not satisfied that MG correctly identified the cause of the damage.
While AC concluded that the foundation soils had suffered a loss of bearing capacity,
his findings do not appear to have been based on any actual testing of the soil.
The subsequent tests carried out by MG identified the moisture content of the soil
near the leaking pipe as 16% (although these tests are of limited use given that, by
the time they were completed, the pipe had been repaired and the underpinning
works completed).
T he FSP’s engineer (FM) advised that, given the nature of the soils at the property,
the moisture content would need to exceed 90% before the characteristics of the
soils would change from plastic to liquid, such that bearing failure would occur.
Given the nature of the soils at the property, the soils would need to be exposed to
considerable volumes of water (over a relatively short period of time), in order to
induce a loss of bearing capacity.
In the present case, the broken pipe was a stormwater drain and therefore would be
exposed to water flows on an intermittent basis only. In these circumstances, a leak
from the pipe would be unlikely to result in a loss of bearing capacity.
Case No: 421271 Determination Page 5 of 6
As outlined above, the FSP’s engineer (FM) concluded that the damage to the
property had occurred due to settlement (downwards movement) of the soils at the
affected corner, due to the drying effects of periodic drought conditions and the roots
of nearby trees.
Based on the photographs provided, I am satisfied that there are trees located
sufficiently near to the property to have a drying effect on the surrounding soils.
In his report, FM noted that the pattern of cracking observed at the property was
consistent with the damage having been caused by differential foundation movement
of this nature.
FM also observed signs of prior repairs to the same areas of the external brickwork
which are the subject of the current claim. The photographs included in the FSP’s
assessor’s report prepared in July 2015 clearly show these repairs, as well as the
presence of cracking damage to other areas of the property.
The existence of prior repairs indicates that the movement issues at the front of the
property were of longstanding duration.
The applicants have not provided any information about when the prior repairs were
effected and/or whether any investigations as to the cause of the damage were
carried out at the relevant time.
Further, the presence of cracking damage to other areas of the property confirms that
it is subject to long-term differential foundation movement, which is consistent with
the property being founded on highly reactive clay soils.
Having carefully reviewed the available information, I consider that the explanation as
to the cause of the damage provided by the FSP’s engineer (FM) is more consistent
with the observed facts, than the explanations provided by AC or MC.
On this basis, I am satisfied that, on the balance of probabilities, the cracking and
movement damage to the applicants’ property was caused by naturally occurring
earth movement, and not by the leaking pipe identified in July 2015.
FSP is not liable for applicants ’ claim
For the reasons outlined above, I am satisfied that the claimed damage to the
applicants’ property was caused by naturally occurring earth movement over an
extended period of time. Damage caused in this manner is excluded from cover
under the policy.
Accordingly, the FSP is not liable for the applicants’ claim.
Case No: 421271 Determination Page 6 of 6
3 Supporting information
3.1 FOS approach to this dispute
This dispute has not been the subject of a FOS recommendation. Due to the nature
of the dispute, it has been referred directly to an Ombudsman for determination, in
line with the Operational Guidelines to the FOS Terms of Reference.
This dispute has been determined based on what is fair in all the circumstances,
having regard to the relevant law, good industry practice, codes of practice and
previous FOS decisions (which are not binding).
There has been a full exchange of all material information relied on for the purposes
of this determination and each party has had the opportunity to address any issues
raised by the other. All of the material provided by the parties has been reviewed and
considered.
While the parties have raised numerous issues in their submissions, for the purposes
of this determination, commentary has been restricted to those issues which are
considered directly relevant to the outcome only.
During the course of this dispute, the applicants have been assisted by their
daughter. For the purposes of this determination, submissions made by the
applicants’ daughter have been treated as if they had been made by the applicants’
themselves.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.