Home / Financial Firm (Unknown - Insurer) / Determination 413814

Determination 413814

Interior ceiling water damage claim declined under gradual deterioration exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2016-04-21
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant claimed for interior ceiling water damage after a storm, which the FSP accepted only for hail damage to the pergola. AFCA found the interior water entered through perished lead flashing, so the damage was excluded as gradual deterioration.

Where gradual deterioration is one of the concurrent proximate causes of the loss and is excluded, the insurer is not liable for the loss under the Wayne Tank principle.

Issues

Subjects and remedies

home or building damagenatural disasterno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 413814 Determination Page 1 of 7 Case number: 413814 21 April 2016 1 Overview 1.1 Dispute The Applicant lodged a claim for storm damage to his home. The Financial Services Provider (FSP) accepted the claim for hail damage to the pergola roof sheeting, but denied liability for water damage to the interior ceilings of the home. The Applicant disputed the FSP’s assessment that the damage was due to deterioration, saying an inspection of the building noted it had been maintained in good condition. A Recommendation was issued by the Service on 27 January 2016. The Recommendation was in favour of the FSP on the basis that the FSP had proven that the damage to the roof flashings was caused by gradual deterioration, which is excluded under the policy. The Recommendation also found that the water which caused the interior damage entered through the damaged flashings, so the proximate cause (or one of the proximate causes) of the interior damage was gradual deterioration and similarly was excluded from cover. The Applicant rejected the Recommendation, saying that when the ceiling damage was being attended to, a tarpaulin was placed over the roof to prevent further damage occurring, and this seemed to stop the problem. He notes that the tarpaulin was not put over the flashings. 1.2 Issues and key findings Has the FSP proven an exclusion applies to the claim for storm damage? The FSP has proven that an exclusion applies because:  the roof’s lead flashings are shown to be perished and cracked  the cause of the damage to the flashings is gradual deterioration and wear and tear, which is excluded under the policy  the interior ceiling damage is in close proximity to the location of the perished flashings  there is insufficient information to establish that the tarpaulin was responsible for stopping water entry to the interior of the home  it is accepted that the water causing the interior damage entered as a result of the cracking to the lead flashings. Case No: 413814 Determination Page 2 of 7 1.3 Determination This determination is in favour of the FSP. The FSP is not liable for the damage to the roof or to the interior ceilings of the Applicant’s home . Case No: 413814 Determination Page 3 of 7 2 Reasons for determination 2.1 Has the FSP proven an exclusion applies to the claim for storm damage? Roof’s lead flashing s are perished and cracked The FSP’s assessment report (undated) states the lead flashings around the kitchen and bedroom pitched section of the roof are perished beyond repair. The report includes photographs, which confirms the assessor’s opinion of the flashings ’ perished condition. In one close up photograph of the flashings over the kitchen, cracking can clearly be seen. Flashings ’ damage is excluded under policy Based on the evidence provided by the FSP, it is accepted that the damage to the lead flashings is gradual deterioration. As the policy contains a general exclusion for gradual deterioration (which encompasses wear and tear, rust and corrosion), the damage to the lead flashings is excluded from cover. Interior ceiling damage is close to location of perished flashings The assessment report provided by the FSP includes a hand drawn diagram depicting the layout of the home. The diagram shows the location of the perished flashings, as well as the location of claimed interior damage (watermarks on the ceiling of the kitchen and bedroom.) Insufficient information to establish tarpaulin was responsible for stopping water entry to interior of home In the Applicant’s submission upon rejecting the Recommendation, he states that the damage to the ceilings needed to be cut away and patched, as it has absorbed water and was weakened. The Applicant says that a tarpaulin was placed across an area of the roof to prevent further damage occurring, and that this seemed to stop the problem. He notes that the area covered did not include the flashings which the FSP’s assessor reported were perished and cracked. It is not known what weather conditions existed after the tarpaulin was put in place. There is therefore insufficient information to show that the tarpaulin was solely responsible for preventing further water ingress to the interior of the home. Even if it were accepted that the tarpaulin was placed on a section of roof which did not include the perished flashings, this does not mean that the water did not enter through the flashings. Case No: 413814 Determination Page 4 of 7 Water causing interior damage entered as a result of cracking to lead flashings Given the proximity of the interior damage to the location of the perished flashings, I accept that the interior damage was caused by water entering through the perished flashings. I therefore accept that on the balance of probabilities, the proximate cause (which is the dominant, effective or operative cause) of the damage was the perished and cracked flashings. As noted by the Case Manager in the Recommendation, it is accepted that another proximate cause of the damage was the storm which affected the area. However, the principle set down in the Wayne Tank and Pump Co Ltd v Employers Liability Assurance Corporation Ltd [1974] QB 57 needs to be considered. That is, if there are two concurrent causes of a loss where one is subject to cover and the other is not, an insurer is not liable for the loss. As the deterioration to the lead flashings is considered to be one of the proximate causes of the damage, and gradual deterioration is excluded under the policy, the FSP is not liable for the damage to the Applicant’s ceiling. Case No: 413814 Determination Page 5 of 7 3 Supporting information 3.1 Other issue Maintenance The Applicant notes that his home was in good repair and has questioned the FSP’s assessor’s reference to lack of maintenance. He does not agree with the assessor’s comment that there was an unusual amount of leaf or debris in the gutters, saying the gutters are cleaned every 4 to 6 weeks. However, there is no reliance placed on the policy exclusion relating to lack of maintenance, so the Applica nt’s arguments in this regard (even if accepted) would have no bearing on the outcome of the dispute. 3.2 FOS Approach It is an accepted principle of general insurance law that an insured bears the onus to show, on the balance of probabilities, that they have suffered a loss caused by an event to which the policy responds. Once this is established, the onus shifts to the insurer to prove the application of an exclusion if it seeks to deny liability for some or all of the loss. 3.3 Policy provisions “ Definitions … Storm Means a violent atmospheric disturbance producing strong winds. It can be accompanied by rain, light ning, hail or snow and it includes cyclones and tornados. Storm does not mean persistent bad weather, heavy or persistent rain by itself. … Insured Event – you are covered for loss or damage to your building or contents (a s applicable) caused by Exclusions to Insured Events … - You are not covered for … … Storm, rainwater and Flood Loss or damage: … to the interior of your building or to your conten ts if the damage or loss has not occurred as a result of an opening made by the Storm. … Case No: 413814 Determination Page 6 of 7 Your Additional Benefits Building and contents benefits The following Additional benefits are included in your policy and are in addition to the sum insured for both building and contents cover. Additional Benefits to your building and contents cover Our exclusions – You are not covered for … … Accidental damage When your building is insured, we will cover you against damage caused unintentionally to your building. …  damage specifically insured by or excluded by any other part of your policy. … What is not covered under your policy Exclusions The following general exclusions apply to all covers under your policy. You are not covered for any loss or damage caused by or resulting from, or the costs incurred from or of: …  Gradual deterioration, including wear and tear, rust, corrosion, depreciation, fading or deterioration from exposure to light;  …  Inherent defects, structural faults, faulty workmanship or faulty design;  Poor maintenance and failure to maintain property in good repair; ” 3.4 Reports referenced Record Key points FSP’s assessor ( C ) Report (undated) Inspection 26 Mar 2014  Applicant noticed water damage to kitchen ceiling and upstairs bedroom 1 ceiling after heavy storm. Rear pergola also damaged by hail in storm.  Building is 31 - 40 y/o - has been maint ained in good condition. DAMAGE NOTED  Small section of plaster ceiling to downstairs kitchen wat er damaged.  Upstairs bedroom 1 – small section of plaster ceiling water damaged  Rear pergola 2 polycarbonate sheets have holes.  All lead flashing around kitchen and bedroom are perished beyond repair and require replacement.  Alcore flashing running along skillion section of roof over kitchen is inadequate and not installed correctly.  Tiled apex on top storey is missing pointing to 1 ridge cap tile over kitchen/lounge. CAUSE OF DAMAGE  Damage caused by a combination of factors  Resultan t damage caus ed by poor workmanship – lack of Case No: 413814 Determination Page 7 of 7 maintenance.  If roof flashing were installed as per BCA standards originally, the damage to the int ernal plaster ceilings would not have occurred .  G utters should be kept clean of tree and leaf debris in the fut ure to ensure water can freely flow in them; the debris in gutters have not contribut ed to the ingress of wat er on this occasion.  2 sheets of damaged polycarbonate to rear pergola are consistent with hail damage.  A lcore flashing runs along skillion roof o ver the kitchen and pergola has not been installed to the BCA .  Point w here tile roof intersects flat metal roof does not have correct transition flashing installed ; must be replaced with the correct type of transition flashing .  Lead flas hing above the kitc hen gable roof is cracked and perished, is considered normal wear and tear, must be replaced .  R oof tile pointing on top storey roof is missing pointing to 1 ridge cap tile over the kitchen/ lounge area .  Recommendation – we submit this causation report for your consideration with a rec ommendation of “UNSURE”. FSP’s assessing manager ( DC ) Email 4 Jan 2016  Estimator reference to perished lead flashing - it is normal and a trait of lead to break down over time and s plit.  R oof takes the brunt of the elements over every season with no protection - roof timbers/framing move quite significantly bet ween seasons , in turn moving tiles .  Ou r opinion would be damage to lead flashing is due to age, wear and tear along with normal workings / mov ement of roof .  Note - T here would be denting to lead if the lead flashing had been damaged by hail .  Roofing code applies from 1992 (AS 1562.1.1992) - has no significant effect on this claim .  Flashing is holding water and not dispersing water - requires r e placement : o d eterioration is not from a single defined [event] , but rather normal wear and tear o w hen it is replaced it needs to deem to satisfy the BCA requirements .  However when the flashing was originally installed there may well of been no Australian St andards applicable , but our opinion is it was never carried out in a tradesman like manner .

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.