Text of the determination
Determination
Case No: 413453 Determination Page 1 of 10
Case number: 413453 10 February 2016
1 Overview
1.1 Dispute
The Applicants say water leaking from a broken water pipe caused cracks in their
house.
The Financial Services Provider (FSP) sent out experts to inspect the cracks. Based
on the experts‟ opinion, the FSP says the cracks were not caused by any insured
event covered by the policy.
The Case Manager provided the parties with a Recommendation on the issues in
dispute. The Recommendation was mainly in favour of the FSP save the Case
Manager recommended the FSP was liable to pay the exploratory costs incurred by
the Applicants.
The FSP accepted the Recommendation but it was not accepted by the Applicants.
In the circumstances, the dispute has been referred to me for Determination.
1.2 Issues and key findings
Is the FSP liable for the Applicants’ damage?
The FSP is not liable for the Applicants‟ damage because:
the available evidence does not establish, on the balance of probabilities, the
cracking damage was caused by the insured event of either storm or the
escape of water
the preponderance of expert evidence from the FSP‟s builder, the FSP‟s
engineer and the Applicants‟ engineer is the site is on a reactive clay soil base;
the FSP‟s exper ts say the cracks are due to movement of the footings and
foundations from seasonal changes in this clay soil, rather than from a single
event; this cause of damage is excluded from cover
material from an earlier claim, the expert opinion and the photographs establish
earlier cracking damage and repairs
the Applicants‟ expert did not persuasively establish a link between the leaking
water meter and the cracking damage
the FSP‟s expert thoroughly inspected the property and the damage is
widespread as evidenced by the site plans and photographs
although the Applicants‟ plumber found a small water leak from the water meter,
the water leak had probably been there a long time, and, in these
circumstances, the policy does not provide cover
Case No: 413453 Determination Page 2 of 10
Is the FSP liable to pay the Applicants for exploratory costs?
The policy provides a benefit to cover the cost to locate the source of a water leak,
even if there was no “E scape of liquid ” insured event. The FSP is liable to pay the
proven exploratory costs incurred by the Applicants.
1.3 Determination
This Determination is substantially in favour of the FSP.
The FSP is entitled to maintain its denial of the Applicants‟ claim for damage.
The Applicants are required to obtain a breakdown of the plumber‟s invoice within 14
days of the acceptance of this Determination. Upon submitting this breakdown to the
FSP, the FSP is required to reimburse the exploratory costs within 7 days.
If the Applicants‟ plumber is unable or unwilling to provide a breakdown, it is fair in all
the circumsta nces the FSP pay half the plumber‟s invoice in the amount of $249.25.
Case No: 413453 Determination Page 3 of 10
2 Reasons for Decision
I have decided this case on its merits, having regard to the relevant law, good
industry practice, codes of practice and previous FOS decisions. I have taken into
account all the material submitted by the parties, both before and after the
Recommendation. I am satisfied the documentation I have relied on has been
provided to both parties.
No new material provided after the Recommendation
After the Recommendation was rejected, the Applicants made a further submission.
They essentially reiterated their position submitting the FSP has not proven the
length of time of water damage. They say this area of the building had the most
damage is reinforced as shown in plan of repair work.
2.1 Is the FSP liable for the Applicants’ damage
Applicants must establish damage caused by storm or escape of water
Initially, the Applicants claimed a storm event on 22 February 2015 caused cracking
damage to the living room ceiling in the insured property.
After the claim was denied, the Applicants contended they were advised there was a
leak in the property which caused the claimed cracking damage to the ceiling and
other parts of the insured property.
The Applicants‟ policy provides cover for insured events. The FSP provides cover for
loss or damage at the insured address caused by an insured event during the period
of insurance.
An insured event is defined to mean a single event, accident or occurrence which an
insured did not intend or expect to happen.
In order for the claim to succeed, the Applicants must establish on the balance of
probabilities the claimed damage was caused by an insured event. In the
circumstances of this claim, they must establish the claimed damage was caused by
a storm or by the escape of liquid.
Once established, the onus shifts to the FSP to establish it is entitled to deny or limit
the claim because the claimed damage was caused by an excluded cause such as
ground movement.
Damage not caused by storm as no water marks on ceiling
The Applicants first claimed cracking damage to the living room ceiling caused by a
storm. The FSP engaged an assessor who inspected and photographed the insured
property on 25 February 2015.
Although the assessor noted internal and external cracks, and cracking in the
footings and peers underneath the living room, he found no water marks or stains
anywhere on the ceiling.
Case No: 413453 Determination Page 4 of 10
He concluded the cracks were due to structural movement and not related to the
recent storm event. This opinion was confirmed by the FSP‟s engineer who inspected
the property on 30 March 2015.
No rebuttal material about storm damage has been provided by the Applicants. I note
the assessor‟s findings, made only a few days after the storm event, that there were
no water marks or stains on the ceiling. On the information provided, I am not
satisfied the Applicants have established, on the balance of probabilities, the claimed
damage was caused by the storm event.
Damage not caused by escape of liquid but by foundation movement
The Applicants then contended the claimed cracking damage in the premises was
caused by a leak. In support of this contention, the Applicants provided to the FSP
water rate bill/bills, a letter from their plumbe r, the plumber‟s invoice and a report
from UT engineering.
The Applicants‟ contentions and documents were considered by the FSP‟s engineer
(OC) who also examined and photographed the site on 30 March 2015.
As a result of the site inspection, OC said the clay foundation material is moderately
reactive. He concluded the cracking is consistent with the footings of the building
being in this reactive clay soil and the cracking resulted from general foundation
movement from seasonal changes in the moisture condition of the clay soil.
OC says he is supported in this view by the nature of the cracking which he says
often occurs at or close to window and door openings, wall-to-wall junctions and
junctions of ceilings with walls. OC documented the cracks and defects observed in a
floor plan and photographs.
As a result of this inspection, OC concluded the cracking damage to the property was
as a result of long-term ongoing movement of the building foundations and not the
result of the recent storm event.
The Applicants say if ground movement was responsible for the damage, the entire
house would be affected which they say is not the case. They submit the major
damage is at a corner of the house near a broken water pipe which caused ongoing
damage to other areas as i ndicated on their expert‟s plan. They also contend OC did
not inspect this area of the building.
Cracking damage is widespread and not confined to the single water leak area
When considering the further material provided by the Applicants about the water
leak, OC said the extent of the cracking observed is widespread and unlikely to have
been caused by a single water leak.
The FSP‟s plumber also inspected the property and undertook a number of tests to
the stormwater pipes, downpipes, and sewer lines. He found they were all running
free without visible problems.
On a date unknown, (but presumably sometime before 15 July 2015 when UT
inspected the property), the Applicants‟ plumber inspected the premises and found a
small water leak from the water meter. He noted moss and mould growing which
Case No: 413453 Determination Page 5 of 10
indicated to him the small water leak could have been there for a long time. The
plumber is silent as to whether the leak caused damage to the property.
On the floor plan, the Applicant ‟s expert UT noted “water main repaired.” U T ‟s floor
plan also notes areas where the slab will be lifted and where its product will be
injected into the foundations.
However, a careful examination of UT‟s report reveals UT does not provide a
compelling opinion about the cause of the cracking damage to the property. Rather,
UT notes in its report it was advised and believed the problem was due to a
leaking/broken water main. There is no evidence the water main was broken. Even if
it was accepted UT believed the need to correct the concrete strip footings and
brickwork at the property was due to a leaking water main, UT makes no case at all
about the link between the material referred to and the cracking damage observed.
Further, other parts of the report support the FSP‟s view. Namely, UT says even after
the proposed injections are made, there may still be ongoing differential footing
movement and damage to the property which would be considered normal at this site
given the reactive nature of the founding soils.
Although the Applicants contend UT strongly believes the entire house would be
effected if the ground movement was responsible for damage, (and they say it is not),
UT has not given this opinion in the report provided.
Further, when I consider carefully the floor plan of UT, the photo locality plan of OC,
and the photographs provided, I am satisfied there is extensive cracking damage to
the property, not just cracking damage local to the repaired water main.
I accept UT‟s injections are required in the area of the repaired water main b ut they
are also required in other areas of the property. Further, although the photographs
taken by OC show damage proximate to the repaired water main near the foyer of
the property, the photographs show this and other cracking damage have been
repaired. This, together with the report from the earlier claim, indicates the cracking
damage was not only confined to a storm event or water leak event in 2015.
Further, the Applicants‟ plumber‟s report supports the contention the small water leak
had been there for a long time due to the moss and mould. The policy terms are
clear. The policy only responds to a single event accident or occurrence, not to water
escaping over a period of time.
FSP’s expert’s photographs demonstrate a thorough inspection of the prope rty
As for the contention OC did not properly or thoroughly inspect the insured property,
having considered OC‟s report, the photo locality plan, and the photographs taken by
OC, I do not accept this contention. It is clear from the material, especially the
photographs, he inspected the inside and outside of the property thoroughly.
The Applicants also relied on the council water rate bill or bills. The parties have
reviewed the bill or bills but they are not provided to the Service.
However, even if the bill or bills showed a high level of water usage, this together
with the observations made by the Applicants‟ plumber there was moss and mould
growing and wet area around the water meter, does not assist the Applicants. This is
Case No: 413453 Determination Page 6 of 10
because the policy does not respond to damage caused by escape of liquid occurring
as a result of a gradual process of leaking over a period of time when an insured
could reasonably expected to be aware of the condition. I consider the Applicants
could reasonably have been expected to be aware of the small leak if there was an
increase in the water bills and in view of the moss and mould and wetness observed
by their plumber.
Having carefully considered all the material provided, and for the reasons stated, I
am not satisfied, on the balance of probabilities, the cracking damage to the property
was caused by the insured event of storm or escape of liquid.
Rather, the material establishes on the balance of probabilities the dominant cause of
the claimed damage is ground movement which cause of damage is excluded from
cover.
2.2 Is the FSP liable to pay the Applicants for exploratory costs?
Policy provides FSP is liable to pay for exploratory costs but not repair costs
The Applicants submitted an undated invoice from their plumber in the amount of
$498.50 for the inspection of and temporary repairs to the small water leak in the
water meter.
Even though the leak is not covered under the insured event “Escape of liquid”, the
policy provides the FSP will pay the cost to locate the source of liquid escaping, up to
$1,500.
There is no evidence provided to establish the exploratory costs caused damage to
the home. Further, the invoice gives no breakdown to establish how much of the
invoice relates to exploratory costs and how much to repairs.
Providing the Applicants can establish some part of the invoice relates to exploratory
costs, by providing a breakdown from the plumber, the FSP is to pay the part of the
plumber‟s invoi ce which relates to exploratory costs.
If the plumber is unable or unwilling to provide this information, I consider it is fair in
all circumstances the FSP pay to the Applicants 50% of the invoice being $249.25.
Case No: 413453 Determination Page 7 of 10
3 Supporting Information
3.1 Extracts from Policy
What you are covered for – Insured events
If you have a Classic, Classic Extras or Platinum insurance policy, we cover your home and
contents when covered under this policy for loss or damage at the insured address caused by
an insured event during the period of insurance
Event or incident
means a single event, accident or occurrence which you did not intend or expect to happen...
Storm
We cover loss or damage caus ed by storm
We do not cover
loss or damage caus ed by erosion, vibration, subsidence, landslip,
landslide, mudslide, collapse, shrinkage or any other earth
movement, but we will cover loss or damage caused by a landslide or
subsidence provide to have occurred within 72 hours of, and directly
because of , a storm and not because of erosion over time, structural
fault or design fault;
Escape of liquid
We cover loss or damage caus ed by liquid leaking,
overflowing or bursting from any of the following:
….
Any drain, fix ed pipes
….
We do not cover
wear and tear, or loss or damage by the escape of
liquid occurring as a result of a gradual process of
leaking, splashing, dripping or overflowing over a
period of time when you could reasonably be
expected to be aware of this condition;
Additional covers
We also provide the cover set out under the following additional covers. A claim under an
additional cover can be made independently of a claim for loss or damage to the home or
contents.
…
Exploratory costs where leak is not covered under insured event „Escape of liquid‟
We cover
If you have home cover, we will pay the cost to locate the source of liquid escaping or
overflowing at the insured address and to repair and restore the damage to your home caused
by our exploratory work if the escape of liquid first happens during the period of insuranc e.
If you make a claim under this additional cover, no excess applies.
Limits
Classic
The most we will pay is $1,500 for eac h incident.
General exclusions
You are not covered under any section of this policy for damage, loss, cost or legal liability tha t
is caused by, arises from or involves:
…
Ground movement
erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage or any other
earth movement, but we will cover landslide or subsidence that is specifically covered under the
following insured events:
Storm‟ (see page 22);
Flood‟ (see page 20);
Earthquake and Tsunami‟ (see page 23);
Explosion‟ (see page 29).
Case No: 413453 Determination Page 8 of 10
3.2 Key material relied on
Record Key points
Insurance schedule Period of ins urance 17/ 11/14 – 17/11/15
Your Home Classic
No optional cover for accidental damage
Events cover including storm and escape of liquid
FSP’s builder (RC )
Report and photographs
25 Feb 2015
Inspected and photographed site 25/2/15. Female Applicant
reported there is a leak on the roof; caused the ceiling in the
living room to crack
Cracks found in the ceiling and cornices of the living room,
archway of a brick wall and around a window but no waters
marks or stains anywhere on the ceiling
Cracks also found in the brickwork outside. This wall was
previously repaired as there were new pointing in the
brickwork
Cracks in the footings and peers underneat h the living room
Builder‟s opinion the cracks were due to structural
movement, related to the footings and foundation. Not related
to recent storm event.
Required a structural engineer to review
FSP’s engineer (OC)
Report and photographs
30 Mar 2015
Site visit by engineer conducted 30 March 2015
Internal and external cracks in ceiling sheets and walls is the
result of long - term ongoing movement of the building
foundations
Defects are not likely the result of the recent storm event
Foundation material is clay indicative of a site that is
moderately reactive which can experience moderate
movement from moisture change
Cracking consistent wi th high level footings of buildings
founded in reactive material, and is likely to be the result of
general foundation movement from seasonal changes in the
moisture condition of the foundation material, from the
movement of water in and out of the soil, r ather than a single
defined event
When there is a change in volume of the foundation material;
the soil expands with wetting and contracts with drying,
resulting in movement of high level footings and consequent
damage in the form of cracking of support ed walls and ot her
building elements. Cracking often occurs at, or close to,
window & door openings, wall to wall junctions, and junctions
of ceilings with walls, which appears to be the case here
Location of the cracks and defects observed are documented
on a floorplan and accompanied by photographs
Recommendations were made regarding future work required
FSP’s plumber (RC )
Report
6 May 2015
Coloured tested stormwater/down pipe s from house to street
and a ll eight lines running free with no visible problems
Tested sewer line and toilet from kitchen to driveway and
Case No: 413453 Determination Page 9 of 10
lines appear to be clear with no visible problems
Applican ts’ engineer
(UT)
Report
29 July 2015
U was engaged to re - support and correct secti ons of
concrete strip footing and brickwork at insured property
Inspected property 15 July 2015
Engineer was “advis ed and believe” the problem was due to
leaking/broken water main. Referred to Council water rate bill
and plumbing report/repair
Provided diagram showing location of cracks and openings in
brick work, where its product would be injected to stabilise
foundations and the location of the repaired water main
Suggested Applicants contact their insurer to investigate a
claim for damage caused
Noted a ll cracks in the brickwork are now a line of articulation
for seasonal movement of the soil. Products such as [ H ] or re -
bricking the wall can reinstate the structural integrity of the
wall ; n ot stabilising clay against natural shrink/swell du e to
moisture changes.
Suggested injections of resin costing $36, 759 to re - support
and correct sections of conc rete footing/brickwork
Noted even after the proposed [ injections] there may be
some ongoing differential footing movement and damage to
this dw elling; long - term minor movement should be expected
and considered normal at this site given the reactive nature
of the founding soils; provided that there are no drainage
problems or other influencing factors affecting this dwelling, it
is anticipated tha t the majority of the movement and cracking
should be limited and future minor ongoing repairs in the
same areas should be considered normal for the life of the
building.
Applicant s’ plumber
(DN)
Letter
19 Aug 2015
Carried out inspection (date unk nown) as Applicants told him
cracks had appeared in the brick walls
Checked the water met er and discovered it was moving
slightly
With further investigation, found moss and mould growing,
indicating a small water leak, which could have been there for
a long time , due to that moss and mould
Carried out temporary repair to give time for the wet area to
dry out
Undated invoice to Applicants $498 for ins pection and
temporary repairs to leak
FSP’s engineer (OC)
Letter
17 Sep 2015
Engineer said a leak may have contributed to the movement
of the building foundation, but the effect would have only
contribut ed to movement in the immediate vicinity of the
water leak.
The extent of the cracking observed is widespread, and
unlikely to have caused by a single water lea k.
FSP’s assessor (PI)
Report
Inspected property 6 March 2012 in relation to a claim that a
severe storm on 10 February 2012 caused leaking damage in
the garage
Case No: 413453 Determination Page 10 of 10
6 Mar 2012 Noted evidence of minor cracking to sections of the joins in
the existing plasterboard ceiling linings adjacent to the
external corner of the brick wall housing the doorway leading
into the property
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.