Home / Financial Firm (Unknown - Insurer) / Determination 413115
Determination 413115
Home insurance claim for garage ceiling collapse declined
Summary
The applicant's garage ceiling collapsed and the FSP declined the home insurance claim under the design and construction exclusion. AFCA found the ceiling was defectively installed and the FSP is not liable.
The proximate cause was installation non-compliant with the applicable 1983 standard, which is excluded, and the Wayne Tank principle also allows denial.
Issues
- Claim denial primary · not upheld“This Determination is in favour of the FSP. The FSP is not liable for the damage to the garage ceiling.”
Subjects and remedies
home or building damageno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
Case No: 413115 Determination Page 1 of 7
Case number: 413115 23 March 2016
1 Overview
1.1 Dispute
The applicant lodged a claim under his home insurance policy with the financial
services provider (FSP), after his garage ceiling collapsed in early 2015. The
applicant believes the damage was caused by high winds experienced on 17 January
2015.
The FSP denied the claim on the basis that the claimed damage was not caused by
strong winds or by any other event insured against under the policy. The FSP also
says the damage was caused by factors which are excluded under the policy, such
as design or construction defects.
1.2 Issues and key findings
Is the FSP liable for the damage to the garage ceiling?
The proximate cause of the damage to the ceiling was the inability of the ceiling to
withstand the loads imposed on it, due to the installer’s failure to comply with the
requirements of the relevant building standards which applied at the time of
construction. Damage caused in this manner is not covered under the policy.
Even if the strong winds experienced on 17 January 2015 acted together with the
defective design and construction to cause the collapse, the FSP would still be
entitled to deny the claim, in accordance with the Wayne Tank principle. This
principle allows an insurer to deny a claim where a loss is caused by two proximate
causes, only one of which is excluded.
1.3 Determination
This Determination is in favour of the FSP.
The FSP is not liable for the damage to the garage ceiling.
Case No: 413115 Determination Page 2 of 7
2 Reasons for Determination
2.1 Is the FSP liable for the damage to the garage ceiling?
Policy provides cover for insured events subject to exclusions
The applicant is required to show that, on the balance of probabilities, he has
suffered a loss caused by a risk insured against under the policy. This is known as a
prima facie claim.
If the applicant is able to establish a prima facie claim, then the onus shifts to the
FSP to show that, on the balance of probabilities, it is entitled to rely on an exclusion
under the policy or is otherwise entitled to deny the claim.
The applicant’s policy provides cover for loss or damage caused by the events listed
in the policy, subject to the conditions and exclusions set out in the policy. The
insured events include storm (which is expressly defined to include wind).
However, the policy contains a general exclusion for damage caused by or arising
from defects in design, workmanship or construction.
The photographs provided by the parties confirm that the applicant’s garage ce iling
initially developed a large crack in the plasterboard sheeting near the double roller
door, with the ceiling in that area observed to be sagging heavily. Approximately two
weeks later, the ceiling collapsed.
The FSP will only be liable for the claimed damage if the proximate cause of the
damage (that is, the real, effective or dominant cause) was one of the events insured
against under the policy.
Based on reports provided by his engineers (BC and SB), the applicant says the
damage was caused by the effect of torsional forces on the ceiling generated by
strong gusts of wind on 17 January 2015.
The FSP disputes that the collapse of the garage ceiling was caused by the winds
experienced on 17 January 2015, which it says were not strong enough to ca use the
claimed damage. Based on reports provided by its building consultant (S), the FSP
says the collapse of the ceiling was due to defects in the manner in which the ceiling
was originally installed.
Accordingly, in order to determine whether the FSP i s liable for the applicant’s claim,
it is necessary to determine the proximate cause of the damage.
As noted above, during the course of this dispute, the parties have appointed several
contractors to determine the cause of the damage. I have carefully reviewed the
reports prepared by the various contractors (together with the other information
provided) in order to determine the proximate cause of the damage.
Ceiling installation did not comply with applicable Australian Standard
The applicant’s garage ceiling was installed in or around 1993, approximately 22
years before it collapsed.
Case No: 413115 Determination Page 3 of 7
The applicable Australian Standard in force at the time was AS 2589 – February
1983 – The Application and Finishing of Gypsum Plasterboard in Framed Dwelling
Construction (the 1983 Standard).
The FSP’s building consultant (S) identified the following specific aspects in which
the applicant’s garage ceiling failed to comply with the 1983 Standard (given the
nature of the plasterboard sheeting used):
the spacing of the framing members (at 600mm) exceeded the maximum
allowable spacing of 450mm; and
the smooth shank nails used to affix the plasterboard sheeting to the timber
members were only 30mm long and therefore were shorter than the minimum
required length of 40mm (in the absence of approval from the manufacturer to
use alternative fastenings).
The applicant’s engineer (BC) says the spacing between the fr aming members was
approximately 540mm, rather than 600mm, as advised by S.
However, even if BC’s measurements are adopted, the spacing between the
members would still exceed the maximum allowed under the 1983 Standard.
BC has provided information which suggests that (at least in some respects) the
manner in which the ceiling was installed complies with the requirements of later
versions of the relevant Australian Standard introduced in 1997 and 2007 (the 1997
Standard and the 2007 Standard respectively).
However, any finding as to whether a structure has design or construction defects
should be based on the relevant building standards which applied at the time the
structure was built. These standards are prepared having regard to, among other
things, the building materials available at the relevant time.
Accordingly, in the present case, I am satisfied that the installation of the applicant’s
garage ceiling was defective, in the sense that it did not comply with the
requirements of the 1983 Standard.
Nevertheless, I accept that it may be appropriate to have regard to the requirements
of the 1997 Standard and the 2007 Standard, in considering whether (and, if so to
what extent), the collapse of the ceiling occurred due to the identified areas of non-
compliance with the 1983 Standard.
Consultants disagree as to cause of damage
The FSP ’s building consultant (S) concluded that the applicant’s garage ceiling had
collapsed due to the defective manner in which it had been installed (that is, the
failure to comply with the framing member spacing requirements and the fastening
specifications specified in the 1983 Standard).
Photographs of the damaged ceiling suggest that approximately 60% of the nails in
the area where the initial damage occurred had come free from the timber truss
bottom chords and remained embedded in the plaster sheeting.
While not conclusive of causation, this feature of the damage certainly suggests that,
had the nails been longer (as required under the 1983 Standard), the collapse may
not have occurred.
Case No: 413115 Determination Page 4 of 7
In his report, S advised that the incorrect manner in which the ceiling had been
installed meant that it was susceptible to premature failure.
S noted that compliance with the minimum standards which applied at the time of
construction was necessary to ensure that the ceiling could withstand the ongoing
effects of gravitational forces, together with stresses imposed over its lifetime as a
result of usual minor building movements.
The FSP has provided copies of publications prepared by the manufacturer of t he
plasterboard sheeting which outline some of the common factors contributing to the
increased incidence of garage ceiling collapses.
The manufacturer’s publications state that such factors typically include non-
conforming framing (including longer truss spanning) and incorrect fasteners, as well
as electrically operated garage doors and a wide range of wind loads.
The applicant’s engineers (BC and SB) concluded that the collapse of the ceiling was
not caused by incorrect installation, but by the effects of wind pressure due to strong
gusts of wind which entered the garage while the front roller door was open.
BC advised that the effects of positive pressure on the windward wall combined with
negative pressure on the side and leeward walls had resulted in the garage structure
becoming pressurised, inducing considerable wind loads and creating torsional
stresses on the ceiling in the vicinity of the front roller door (where the initial damage
occurred).
SB considered that the damage had occurred as a result of either positive wind
pressure induced within the garage while the roller door was open and/or wind
pressure which had built up in the roof cavity while the door was closed.
Failure to withstand wind pressure was due to defective installation
As outlined above, advice provided by the manufacturer of the plasterboard ceiling
sheets confirms that inadequate framing spacing and nail length is a common feature
of garage ceiling collapses. The FSP’s building consultant (S) has concluded this
was the proximate cause of the damage to the applicant’s ceiling .
The applicant’s engineer (BC) says that the manner in which the ceiling was installed
could not have been the proximate cause of the damage as the design of the ceiling
was sufficient to withstand ordinary wind conditions.
BC says that, according to his calculations, the applicant’s ceiling would have been
able to withstand the maximum wind differential pressure of 0.67 kPa specified in the
2007 Standard as the pressure which a ceiling fastening system s hould be designed
to resist.
Accordingly, BC considers the ceiling must have been subject to unusually strong
wind pressure on the day the initial damage occurred.
However, even if BC’s calculations are accepted as correct, I am not satisfied that it
is appropriate to adopt the applied differential pressure specified in a later building
standard when considering the probability that defective installation (having regard to
Case No: 413115 Determination Page 5 of 7
the standard which applied at the time of construction) caused or contributed to the
damage caused in any particular case.
It can be assumed that the requirements specified in the 1983 Standard regarding
framing spacing and fixing characteristics were imposed in order to minimise the risk
of ceiling collapses, having regard to the prevailing circumstances at the time.
Accordingly, non-compliance with those requirements could reasonably be expected
to result in the ceiling being susceptible to the specific damage the requirements
were aimed at preventing.
Further, the finding by the applic ant’s engineer (BC) that the ceiling was subject to
extreme wind pressure is not otherwise supported by the available information.
Bureau of Meteorology records for 17 January 2015 (the date the applicant initially
identified the damage to the ceiling) establish that the maximum wind gust recorded
at a nearby weather station was 52km/hr (at 11:11pm). The wind speed recorded
was above average strength for that time of the year.
The timing of the maximum recorded wind gust is not entirely consistent with BC’s
conclusion that the damage occurred due to strong wind gusts while the garage roller
door was open. The applicant has advised that the door was left open while he was
cleaning the garage during the day.
The Beaufort Wind Scale (BWS) classifies a wind speed of 52km/hr at the lower end
of the range of wind speeds classified as “near gale”. Winds in this category are
noted as resulting in “whole trees in motion” and “inconvenience felt when walking
against the wind”. However, the BWS indicates that wind speeds of at least 76km/hr
are required before even slight structural damage will occur.
The recorded wind speed does not of itself establish the extent of wind pressure
exerted on the applicant’s garage on 17 January 2015, which may be influenced by
other factors such as the location and structural features of the building.
However, in the absence of any other independent information, I am not satisfied that
the garage was subject to extreme wind pressure on 17 January 2015.
For the reasons outlined above, I do not accept BC’s conclusion that, given its
features, the ceiling must have been subject to extreme wind pressures in order for
the observed damage to have occurred.
Based on the available information, I am satisfied that the damage to the ceiling was
caused by its inability to withstand the loads imposed on it, due to the installer’s
failure to comply with the requirements of the 1983 Standard. Had the ceiling been
installed in accordance with the applicable framing spacing and fastening
requirements, it is probable the damage would not have occurred.
FSP is not liable for damage to garage ceiling
For the reasons outlined above, I am satisfied that the proximate cause of the
damage to the garage ceiling was the defective manner in which the ceiling was
designed and constructed. Damage caused in this manner is excluded under the
policy.
Case No: 413115 Determination Page 6 of 7
Even if I were to accept that the strong winds operated interdependently and
concurrently with the defective installation of the ceiling to cause the collapse, the
FSP would still be entitled to deny the claim.
Where a loss is caused by two proximate causes operating in tandem and one is
excluded while the other is not, the exclusion clause operates to allow the insurer to
deny the claim in its entirety. This is an established principle of insurance law known
as the Wayne Tank principle.
Case No: 413115 Determination Page 7 of 7
3 Supporting information
3.1 FOS approach to this dispute
FOS has considered it appropriate to expedite this dispute in accordance with the
Operational Guidelines to the FOS Terms of Reference, due to the nature of the
dispute. Accordingly, this dispute has not been the subject of a FOS Preliminary View
and has proceeded directly to Determination.
This case has been decided on its merits, having regard to the relevant law, good
industry practice, codes of practice and previous FOS decisions.
There has been a full exchange of all material information relied on for the purposes
of this Determination and each party has had the opportunity to address any issues
raised by the other. All of the material provided by the parties has been reviewed and
considered.
While the parties have raised numerous issues in their submissions, for the purposes
of this Determination, commentary has been restricted to those issues which are
considered directly relevant to the outcome only.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.