Home / Financial Firm (Unknown - Insurer) / Determination 409179
Determination 409179
Claim for collapsed balcony denied under seepage, rot and structural defect exclusions
Summary
The applicant's claim for a collapsed balcony was denied by the strata insurer on the basis that seepage and rot caused the loss. AFCA preferred the expert evidence, found the exclusions applied, and ordered nothing.
The FSP must prove the dominant cause fell within an exclusion, and the expert findings and rot evidence established seepage or rot as that cause.
Issues
- Claim denial primary · not upheld“The FSP is entitled to deny liability for the claim as the proximate cause of the loss was seepage or rot, which are excluded.”
- Poor claim handling secondary · not upheld“In regards to PI's conduct, I do not accept his assertion is established.”
Subjects and remedies
home or building damageno remedy
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
Case No: 409179 Determination Page 1 of 4
Case number: 409179 11 November 2015
1 Overview
1.1 Dispute
The Applicant‟s claim for a dropped balcony was denied by the strata insurer, the
Financial Services Provider (FSP), on the basis the loss was due to various factors
excluded under the policy.
The Applicant has disputed this as he submits the damage was due to a heavy storm
on 3 January 2015.
1.2 Issues and key findings
Can the FSP deny the claim?
The FSP can deny the claim because:
it is clear that there was rot to the structural beam within the area of collapse
this supports the FSP‟s expert‟s (PI) conclusion that the damage was due to
seepage and rot
the policy excludes damage caused by seepage or rot
1.3 Determination
This Determination is in favour of the FSP.
The FSP is entitled to deny liability for the Applicant‟s claim.
Case No: 409179 Determination Page 2 of 4
2 Reasons for Determination
2.1 Can the FSP deny the claim?
FSP must establish at least one of the exclusions
The FSP is relying upon the following exclusions to deny the claim:
“We will not cover Your Insured Property for Damage arising from or caused by:
14. … seepage
17. … gradual deterioration … wear or tear, wet or dry rot
18. … faulty workmanship, structural defect or faulty design
20. Water entering Your Building(s) because of a structural defect, faulty design or faulty
workmanship when Your Building(s) were constructed.”
If one of the exclusions is applicable to the Applicant‟s claim, then the FSP is able to
deny liability.
The FSP is required to establish the applicability of the exclusion. This requires the
FSP to demonstrate that the dominant or efficient cause (“the proximate cause”) of
the loss was one of these exclusions.
The relevant standard of proof is the balance of probabilities.
PI’s findings are supported by photographs
The FSP has relied upon PI‟s report to substantiate its position.
The Applicant has disputed this as he maintains there were heavy winds on 3
January 2015 which caused the balcony to lift and then drop. His position was
supported by BB, the builder who completed make safe repairs on 16 January 2015
(the day after he lodged the claim).
Having carefully reviewed all the available evidence though, I prefer the findings of
PI‟s report for the following reasons.
First, and of most significance, the photographs of the structural beam underneath
the area of collapse show evidence of rot. The existence of rot supports PI‟s
conclusion that seepage within this area has resulted in rot which in turn caused the
beam to collapse.
Second, PI‟s conclusion th at the cause was this rot rather than storm is consistent
with the fact that the storm damage to the balcony is isolated to this area.
Third, BB‟s report is limited. It provides no reasoning to support their conclusion.
In particular, it makes no reference to the existence of rot in the area of collapse and
why this could not have been a proximate cause to the loss. Therefore, it is difficult to
place much weight on their conclusion.
It is likely the damage would not have occurred if there was no rot
I acknowledge the Applicant‟s position that the damage manifested after a storm.
Case No: 409179 Determination Page 3 of 4
However, this does not overcome the fact that PI‟s report and the photographs in
support demonstrate that seepage and existence of rot were a dominant and efficient
cause.
This is because it is difficult to accept the damage would have occurred if there was
no seepage or rot. Particularly given the property‟s structural damage was isolated to
this area.
Therefore, I accept the proximate cause of the loss was either seepage or rot.
As these factors are excluded under the policy, then the FSP is entitled to deny
liability for the claim.
Applicant’s arguments do not assist him
The Applicant has also argued the following:
he was not aware of any defects in his property,
PI were only interested in finding a way to deny the claim
I note the exclusions are not qualified in any way about the Applicant‟s knowledge of
their existence. It simply states that if the cause of loss falls within that exclusion,
then the FSP is entitled to deny the claim.
In regards to PI‟s conduct, I do not accept his assertion is established.
Regardless, I have preferred PI‟s findings because of the clear fact that there was
existence of rot in the area of damage. This substantive fact supports the opinion
drawn and is plausible and logical on the face of it.
Accordingly, I do not accept the Applicant‟s arguments assist him.
3 Supporting information
3.1 Expert Reports
Record Key points
FSP’s expert (PI )
Report
23 Jan 2015
Discussions with the Owners Corporations manager revealed
multiple lot owners have undertaken to rectify building defects
caused in the building‟s original construction
Our inspection failed to identify any „impact - type‟ or
Storm/tempest damage to the surrounding surfaces
Inspection of the balcony subfloor identified that the structural
supporting beams have rotted and deteriorated over an
extended period due to long - term seepage
The beams reached a critical stage of compromise and
ultimately failed
The interface bet ween the two adjoi ning balconies have not
been adequately sealed – over an extended period, water
has seeped into the substructure
Neighbouring split system air - conditioner not adequat ely
draining for an extended period – this contribut ed moisture
Case No: 409179 Determination Page 4 of 4
and water to balcony
FSP’ s expert (B B )
Report /
16 Jan 2015
We were advised the balcony had dropped and was requiring
propping
Our trades believed the damage to have been caused by
storm
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.