Home / Financial Firm (Unknown - Insurer) / Determination 407436

Determination 407436

Peeling ceiling and cornice paint declined as unrelated to 2012 storm claim

FirmFinancial Firm (Unknown - Insurer)
Decided2015-11-24
ProductGeneral Insurance · Landlord
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The landlord claimed for widespread peeling ceiling and cornice paint, linking it to a 2012 storm water claim, and the insurer denied it as deterioration. AFCA ordered the insurer to rectify the previously repaired area but upheld its denial of the balance of the damage.

The damage to the area repaired under the 2012 claim is separate and covered for rectification, while the wider paint failure is attributed to gradual deterioration and poor preparation, which the policy excludes.

Issues

Subjects and remedies

home or building damagerepair or rectify

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 407436 Determination Page 1 of 5 Case number : 407436 21 October 2015 1 Overview 1.1 Dispute The Applicant held a Landlord Residential Insurance Policy (the policy) with the Financial Services Provider (FSP) for a tenanted property (insured property). The Applicant lodged a claim on 5 March 2015 seeking cover for the peeling and flaking of plasterboard ceilings and cornices throughout a majority of the property. He maintains this relates to a stormwater ingress claim in 2012. The FSP has declined the claim on the basis the peeling and flaking paint (the damage) is not related to the 2012 storm event. Rather, it is due to age related deterioration as well as inadequate sealer/primer or poor quality ceiling paint. 1.2 Issues and key findings What is the scope of the policy? The policy provides cover for accidental loss or damage to the insured buildings or contents. It also extends cover under specific conditions for a range of incidents and additional covers. The cover is subject to the specified as well as general policy exclusions and limitations. Is the FSP liable for the damage claimed? The FSP is liable for that damage to the area previously repaired under the storm damage claim in 2012. For the balance of the damage to the ceilings and cornices the FSP is entitled to deny cover in line with the exclusions specified within the terms of the policy. 1.3 Determination This Determination is partially in favour of the Applicant. The FSP is to arrange for the rectification of repairs which it had authorised under the 2012 storm damage claim. Otherwise, the FSP is entitled to rely upon the policy exclusions to deny liability for the remaining damage. Case No: 407436 Determination Page 2 of 5 2 Reasons for Determination 2.1 What is the scope of the policy? The policy provides cover for accidental loss or damage and specified events The policy provides cover for damage to, and loss or destruction of the insured building(s) caused by an unintentional act, or an unforeseen and uncontrollable incident. In addition to the above, the policy also provides cover for certain specified events and additional covers as noted within the Product Disclosure Statement (PDS). The above cover however is subject to the specified policy limitations and general exclusions provided within the PDS. I am satisfied the damage subject of this dispute reasonably falls within the scope of accidental damage and/or Storm damage which are circumstance covered under the policy. The onus rests with the FSP to establish, on balance, the application of the relevant policy limitations/exclusions, it seeks to rely upon. 2.2 Is the FSP liable for the damage claimed? The FSP is liable to rectify the damage to the area previously repaired in 2012 I have carefully considered all the information made available by the parties and am satisfied of the following:  the Applicant lodged a claim under the policy for storm water ingress in 2012 which was accepted by the FSP  although initially stated by the FSP that the repairs completed in 2012 were limited to repair/replacement and repainting of 1m 2 of plasterboard ceiling under the point of ingress in the kitchen. The available information has shown this to actually be 10m 2  in March 2015 the Applicant contacted the FSP seeking cover for extensive peeling and flaking of ceiling and cornice paint throughout the insured property including the area of repairs authorized by the FSP in 2012  various consultants were appointed by both parties to determine the extent and cause for the damage claimed  the Applicant is of the strong view the damage related to the 2012 water ingress event  the FSP however is adamant the damage is not relates to the 2012 event rather it is due to deterioration over time as well as a loss of adhesion due to inadequate sealer/primer or poor quality ceiling paint originally used  there is no evidence which would establish, on balance, the occurrence of a subsequent water ingress event since 2012. Case No: 407436 Determination Page 3 of 5 The FSP’s obligation is limited to rectification of repairs authorised in 2012 The information provided by the Applicant as well as the FSP’s consultants’ refer to peeling paint damage in the area where repairs were authorised by the FSP under the 2012 storm damage claim. I am satisfied this damage is separate to the remaining home with respect to its assessment and consideration under the policy. It is not subject to the relevant policy limitations that apply to the remaining sections of the insured property considered below. The FSP is to arrange for the repair and rectification of the damage to the area repaired by its authorised repairer ‘W’ in 2012. The consultants are consistent in the view the damage to the ceiling and cornice paintwork is significant and exists throughout the insured property. The Applicant’s preferred consultants ‘TS’ and ‘R’ consider the damage is due to the presence of moisture/water/condensation in the roof cavity. However, there is an absence of any substantiating evidence to establish a leak or water ingress had occurred resulting in the damage. The FSP’s consultants consider it is not due to the 2012 event as if this was the case the damage would have become evident earlier once the plasterboard ceilings had dried. The consultants state water damage to plasterboard ceilings is characterised by deflection, deformation and creeping of the damp plasterboard between supporting battens due to the raised moisture levels. The FSP’s consultants’ are consistent in the view that there is an absence of signs of water damage which could reasonably be relied upon to establish the damage claimed is due to water ingress. They consider the damage is consistent with the paint losing elasticity due to age deterioration and a loss or adhesion due to poor preparation of the ceiling surface (prior to painting) and materials used. Having considered a ll the available information I am satisfied the FSP’s consultants’ reports are the more complete and compelling. I am not satisfied it has been established the damage claimed can be related back to the 2012 event. The policy clearly excludes cover for loss or damage arising from:  gradual deterioration and wear and tear  defective workmanship or materials. Accordingly, the FSP is not obliged to cover the balance of the damage other than that the area repaired for storm damage in 2012. 3 Supporting information 3.1 Relevant policy wording Landlords Residential Property Insurance Landlords Residential Property Insurance provides cover for any accidental loss or damage to the buildings or contents that make up your rental property. We also provide cover under specific conditions for a range of incidents and additional covers. Case No: 407436 Determination Page 4 of 5 … Accidental damage cover, additional cover and optional cover exclusions We will not cover any loss or damage as a result of, or caused by: • erosion, rust, corrosion, gradual deterioration, de preciation, wear or tear • a defect in an item, structural defects, or faulty workmanship or design 3.2 Consultants’ reports Record Key points Applicant’s e xpert ( TS ) Report  attended the insured property on 19 March 2015  provided a quote for temporary solution of the flaking and peeling painted ceilings in the master bedroom, dining room, laundry and lounge room (not cornices)  was of the view the Applicant needed to be advised the paint damage to ceilings and cornices is extensive and more than likely c aused by water and condensation in the roof cavity  TS did not enter the roof cavity and it was only an educated guess  TS’s recommendation was for the entire internal ceilings and walls to be repainted as well as inspect the integrity of the waterproofing FSP’s expert (AC) Report 30 March 2015  Completed a site visit on 24 March 2015 and provided opinion on causation as:  there was no evidence water ent ry/staining damage  paint delamination has occurred as a result of lack of surface preparation resulting in t he painted finish failing to adhere to the ceilings lining over an extended period of time  there was no evidence to establish the water ingress in 2012 saturated all of the ceilings throughout the house rather it was limited to a smaller area  if there had been saturation of all ceilings any resultant damage would have become evident soon after the ceilings had dried completely  TS was not of the view the damage claimed was due to an insured event. FSP’s Engineer (M ) Report 1 July 2015  completed a site inspe ction on 23 June 2015  in M’s opinion the peeling paint in general area of repairs done in 2012 (peeling and flaking) by ‘W’ would be considered a building defect  in M’s opinion damage due to water and moisture in the ceiling plasterboard is normally charac teriz ed by deflection, deformation and creeping of the damp plasterboard between supporting battens due to the raised moisture level in the plaster and paper reinforcement Case No: 407436 Determination Page 5 of 5  M observed no evidence of ceiling plasterboard deflection, deformation or creep in a ny of the rooms assessed at the insured property  further condensation was not normally an issue with conc rete tile roofs  M was of the view that it was highly unlikely the ceilings insulation and storm event in 2012 has influenc e on the peeling and flaking ceiling painting as well as peeling and flaking cornices throughout the home  in M’s opinion this was due to the ceiling paint losing its elasticity most likely due to age det erioration  also at the edges of the ceiling sheets and the cornice there has been loss or adhesion whic h is most likely due to inadequate sealer/primer or the quality of the paint used Applicant’s expert (R ) Report 23 August 2015  in R’s professional view moisture in the ceiling cavity had contribut ed to the ceiling and cornices peeling in all areas other than the kitchen  no water stains visible which indicates unlikely there was a leak.  rather, water had ent ered at some stage previously creating very moist and humid air consequently speeding up the peeling process Applicant’s expert (K ) Report 17 August 2015  is a self - employed plasterer who completed repairs to the plasterboard ceiling at the insured property in 2012 after storm water entered  replaced substantial area of ceiling plasterboard of approximately 10m 2 above the kitchen and f amily room  he did not repaint the replaced plasterboard FSP’s Assessor (S ) Report  date of assessment 18 May 2015, visual inspection revealed:  previous repair to plasterboard ceiling in kitchen of fair standard  paint to cornices flaking and delaminating  peeling paint consistent with that which occurs due to poor preparation of the surface prior to painting  ceilings in bathroom and bedroom 1 has been repainted since peeling began  peeling is not isolated to any location close to the insured event covered in 2012 and extends throughout the house  no evidence of subsequent water ingress which would cause damage to ceilings.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.