Home / Financial Firm (Unknown - Insurer) / Determination 406765

Determination 406765

Strata building damage claim denied under earth movement exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2016-06-10
ProductGeneral Insurance · Strata
OutcomeFor the complainant in part
Amount awarded$51,037
Non-financial loss—
Amount claimed$68,050
SourceAFCA PDF

Summary

A strata body corporate claimed for building damage that the insurer denied under an earth movement exclusion. AFCA found the exclusion did not apply to heave caused by excessive moisture, but apportioned liability at 75% for settlement damage, ordering $51,037.30 plus statutory interest.

The earth movement exclusion does not cover heave from excessive moisture under an accidental damage policy, while uninsured pre-existing settlement damage justified apportioning the claim.

Issues

Subjects and remedies

home or building damagepay claimpay interest

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 406765 Determination Page 1 of 5 Case number: 406765 8 June 2016 1 Overview 1.1 Dispute The Applicants were members of a body corporate which held a strata insurance policy from 22 November 2012 covering buildings and common contents for accidental loss or damage occurring during the period of insurance. The Applicants lodged a claim with the Financial Service Provider (FSP) after discovering damage to the property on 31 October 2014. Following investigation, the FSP denied the claim on the grounds the damage was due to earth movement which is excluded under the terms of the policy. The Applicants dispute the FSP’s findings. 1.2 Issues and key findings Have the Applicants established a claim within the terms of the policy? The Applicants have established a claim within the terms of the policy. The policy provides cover for accidental loss or damage to the building and common contents occurring during the period of insurance. There is no dispute that the damage is accidental damage and occurred during the period of insurance. Is the FSP entitled to rely upon the exclusions within the policy to defeat the claim? The FSP is not entitled to rely upon the exclusions contained in the policy. On balance, the proximate cause of the damage to the rear and side of the property is excessive moisture and not earth movement as argued by the FSP. Is the FSP entitled to limit its liability? The FSP is entitled to limit its liability as damage to the front of the property was due to subsidence and earth movement not covered under the terms of the policy. 1.3 Determination This Determination is in favour of the Applicants. The FSP is to pay the Applicants the sum of $51,037.30 being 75% of the cost of repairs as quoted plus interest in accordance with Section 57 of the Insurance Contracts Act 1984 (the Act) from 5 Case No: 406765 Determination Page 2 of 5 August 2015 being the date of the FSP’s final decision letter to date of payment of the claim. 2 Reasons for Determination There has been a full exchange of material between the parties and eac h party has had the opportunity of addressing the issues that arise from the information exchanged. Two Panel members including the Ombudsman conducted a site inspection of the property on 29 April 2016. A neighbour MM who also has a dispute with the FSP was present as was the Applicants ’ tenant and a real estate agent. The FSP attended with an engineer MW. MW was able to assist the Panel members in explaining the potential cause of damage. This Determination follows consideration of all of the information exchanged and is based on what is fair in all the circumstances, having regard to the relevant legal principles, terms of the policy, good industry practice including relevant codes of practice and prior Determinations where applicable. 2.1 Have the Applicants established a claim within the terms of the policy? The Applicants have established a claim within the terms of the policy The Applicants’ policy is an accidental damage policy and provides cover for accidental loss or damage to the buildings and common contents which occur during the period of insurance. Accidental means something that is not intended or expected. It is apparent from the information exchanged that the Applicants had not intended or expected the damage sustained to the property. The Appli cants’ claim they first observed external damage in October 2014. This was during the period of insurance. They subsequently observed a crack developing in the internal wall lining to the rear wall of the ground floor living room. This is supported by findings in the report from HCE. In the circumstances, the Panel is satisfied that the damage identified to the Applicants’ property can be classified as ‘accidental damage’ for the purpose of the policy. 2.2 Has the FSP established the application of an exclusion? The FSP has not established the application of an exclusion The FSP maintains the exclusion clauses relating to damage caused by earth movement apply. The policy provides a number of clauses which are set out in the supporting information that relate to the exclusion for earth movement. Case No: 406765 Determination Page 3 of 5 The engineer HCE inspected the Applicants’ property in April 2015. The report identified the movement of the property and identified ongoing damage occurring to the property as a result of movement. The report also identif ied the Applicants’ complaints of constant dampness to the ground surface of the west side of the house. According to the report, the cracking movement evidenced in the property was typical of problems that can occur due to differential movement of footings. It identified heaving of the footings at the rear North West corner of the house indicating excessive wetting of the foundation material and suggested a geo- technical investigation be carried out. This was not consistent with seasonal changes in the moisture content of the soil or consistent with the very dry conditions experienced since 2012 as noted in the report. A second engineering report was provided by GRD. That report dated 30 December 2014 identified that the concrete slab footings supporting t he Applicants’ home had experienced some distortion consistent with heave towards the rear north western corner of the dwelling. This is consistent with swelling caused by excessive moisture. A geo-technical report was provided by HG. That report dated 22 April 2015 identified the soil more moist to the rear of the site and remains more moist with depth. Although not identifying the source of the water, the report identifies a number of possible causes. The report recommends a number of other tests be carried out. A leak detection report found some minor damage in a PVC stormwater line. The consultant was unable to properly examine the sewer line. The report offers little evidence of the likely cause of the moisture which remains a mystery. During the site inspection on 29 April 2016 Panel members were able to observe the damage to the Applicant’s property. The articulation joint to the west of the building showed separation of a range of 20-30mm. There appeared to be some small degree of settlement at the front and rotation to the south but also some rotation of the western wall to the west. At the rear of the property there was clear heave along the northern wall towards the west. It was apparent from the inspection and discussions with MW that the northern wall had moved vertically upwards causing significant steeped cracks window high, adjacent to the lintel across the top of the window. The pattern of movement was consistent with heave at this point. The extent of heave had also caused the western wall to rotate to the west consistent with observations from the front. At the north-west corner of the building there was evidence of some excavation work but it was unclear as to what had occurred. This may be the feature noted in the reports from CRD and HG which makes reference and includes images of the sewer overflow and its blockage by domestic items. There was no evidence of that during the inspection. The Panel notes the area is close to where the reported excess moisture and heave has occurred. The door in the middle of the north wall also showed some signs of movement (heave) and there was evidence of some previous pointing. Case No: 406765 Determination Page 4 of 5 Reports had mentioned the effect of three air conditioner units but there was no obvious evidence that these were in play. Excessive moisture causing heave Although the FSP has referred to the exclusion relating to earth movement, the relevant exclusion refers to erosion, subsidence, landslide, mudslide, shrinkage or other earth movement. It does not refer to excessive moisture causing heave. Based on the information available, the excessive moisture has caused heaving of the footings which has led to damage. The exact cause of the excessive moisture has not been identified. The policy is an accidental damage policy. In the absence of evidence to the contrary the Panel is satisfied that the damage caused by the excessive moisture is accidental damage. 2.3 Is the FSP entitled to limit its liability? The FSP is entitled to limit its liability The Panel is satisfied that the FSP is liable to limit its liability to 75% of the total amount claimed. The policy provides cover in the event of loss or damage occurring during the period of cover. According to the FSP, the policy was incepted on 22 November 2013 approximately 12 months prior to the Applicants first discovering the damage. The FSP’s loss adjustor suggested the damage had been ongoing for a period of three to five years. The engineering reports from HCE and CRD indicate the soil was highly reactive soil which would have been affected by the drought conditions in Melbourne prior to 2011 and subsequent heavy rainfall. It is likely that this would have caused some movement to the property. Such damage is unlikely to be related to the damage caused by the excessive moisture in the soil. The existing information is not sufficient to allow the Panel to determine the extent to which there was pre-existing damage to the property. The Applicant did not obtain an inspection report and whilst the FSP’s loss adjuster suggests damage had been ongoing for three to five years there is no other evidence to support this. The Panel notes that there is damage caused by settlement to the front of the property. The location of this damage is well removed from the area where excess moisture and heave occurred. On the balance of probabilities this settlement is the result of general movement over time and would fall within the exclusion reli ed upon by the FSP. Given the difficulty in separating out the point at which the insured loss and the uninsured loss could be separated, and the allocation of the costs, the Panel concludes that it is fair in all the circumstances that this be apportioned 75% in favour of the Applicants. Extent of loss or damage The Applicants have provided three quotes namely the following:  Plumbing quote $10,380. Case No: 406765 Determination Page 5 of 5  Building quote (internal repairs) $26,125.  Urathane – underpinning quote - $31,544.73. TOTAL $68,049.73 Accor dingly, the FSP is liable to pay the Applicants’ claim in the sum of $51,037.30 being 75% of the assessed damage plus interest in accordance with the Insurance Contracts Act 1984 from the date of the FSP’s decision to reject the Applicants’ claim being 15 August 2015 to the date of payment of the claim.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.