Storm claim exclusion for rust-damaged steel support posts

FirmFinancial Firm (Unknown - Insurer)
Decided2016-04-21
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

After cyclone Marcia the FSP accepted most of the applicant's home damage but excluded the steel support posts. AFCA found rust and corrosion was the proximate cause of the post damage, which is excluded, so the FSP is not liable for it.

Rust and corrosion, not the storm, was the dominant cause of the post failure, and the exclusion does not depend on the applicant's knowledge.

Issues

Subjects and remedies

home or building damagenatural disasterno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination Case No: 405768 Determination Page 1 of 4 Case number: 405768 21 April 2016 1 Overview 1.1 Dispute The applicant holds a home building and contents policy with the Financial Services Provider (FSP) covering her home address. On 23 February 2015 the property was damaged by cyclone Marcia and a claim submitted under the policy. The FSP accepted the claim and arranged a cash settlement representing the cost of repairs. However, the FSP excluded damage to the steel support posts as it considered these had not been damaged by the cyclone. Rather the cause of the damage to these posts was rust and corrosion, both of which are specifically excluded under the terms of the policy. 1.2 Issue and key findings Was the FSP entitled to limit its liability for the claim? The FSP was entitled to exclude the steel support posts from the claim because the proximate cause of the damage to the posts is rust and corrosion, which is specifically excluded from cover. 1.3 Determination This determination is in favour of the FSP. The FSP was entitled to exclude the steel support posts from the claim and is not required to take any further action. Case No: 405768 Determination Page 2 of 4 2 Reasons for determination 2.1 Was the FSP entitled to limit its liability for the claim? The policy excludes wear and tear including rust, corrosion and deterioration There is no dispute that the applicant has established there was a storm that damaged her property. The FSP has accepted liability to much of the damage to the applicant’s home. However, the FSP denies it is liable in respect of the damage to the steel posts supporting the building on the basis the damage was caused by rust and corrosion rather than the storm. Loss or damage caused directly, indirectly or in any way connected with rust, corrosion and deterioration is excluded under the policy. The FSP has the onus of establishing it is entitled to deny the claim on the basis of the exclusion. The rust must be the proximate cause of the loss for the FSP to deny cover In order for the steel posts to be excluded from cover, the FSP must establish that the proximate cause of the damage to the posts was the rust rather than the storm. The proximate cause of the loss is the dominant or effective or operative cause of the loss, whether or not that be the last in time or the sole cause. This means that even if the cyclone was the last event to cause the posts to break, this does not mean it is necessarily the proximate cause of the loss. To determine the dominant cause, each cause (be it rust or the storm) must be examined for the qualities of reality, predominance and efficiency as the active, efficient cause. If one cause (such as the storm or rust) would have caused the harm in any case, and the other would not have done so in the absence of the first, the first is the proximate cause. The proximate cause of the loss was rust and corrosion The applicant says that as a result of the lateral loads the property was subjected to during the cyclone, the storm caused five of the posts to break at the base. The home is set atop approximately 30 steel support posts and had been relocated to the site approximately 20 years earlier. It is believed that the support posts date from the time of relocation. Building consults firm "S" inspected the property and prepared a scope of work for the storm related damage. However, S considered the support posts were not damaged by the claimed event, but rather, exhibited damage consistent with long term issues such as rust and corrosion. S noted the posts had corrosion approxima tely 20mm below ground level, which had penetrated the entire wall depth of the post. S considered the posts had been installed incorrectly at the time the house was relocated, as it was accepted practice Case No: 405768 Determination Page 3 of 4 at that time to 'dome' the concrete to protect the steel. S considered the damage to be a maintenance issue, rather than a result of the cyclone. Engineering firm "HB" also inspected the posts. HB considered the posts had disconnected from their footings as a result of corrosion. HB considered the corrosi on had begun occurring from the time of installation whenever moisture was present around the posts. HB considered the only contribution the cyclone event had to the damage which was now evident was that it was 'the final straw' which caused the corroded posts to finally fracture. Both S and HB have provided photographs of the posts in question, which shows rust and corrosion around the base of the posts. I accept both S and HB are appropriately qualified and experienced to comment in this matter and that I can place considerable weight on their findings. Further, there is no contradictory evidence available. Accordingly, I am satisfied that the proximate cause of the damage to the steel posts was rust and corrosion, rather than the storm. This is even though the storm was last in time. That the applicant was unaware of the rust does not change the outcome The applicant states she was unaware of the incorrect installation of the posts and/or the extent of the rust and corrosion. The applicant therefore did not know that the posts may break in a storm. However, the exclusion relating to rust and corrosion is no t contingent upon the applicant’ s knowledge at any particular time. Nor is it contingent on the rust and corrosion being present before the contract was entered into. Accordingly, the FSP is entitled to deny the claim. Case No: 405768 Determination Page 4 of 4 3 Supporting information 3.1 FOS approach to this dispute I have decided this dispute based on what is fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all the material submitted by the parties, both before and after the recommendation was issued. I am satisfied that the documentation I have relied on has been provided to both parties and each party has had an opportunity to address the issues raised.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.