Text of the determination
Determination
Case No: 400346 Determination Page 1 of 7
Case number: 400346 1 June 2016
1 Overview
1.1 Dispute
The applicant lodged a claim under his home insurance policy with the financial
services provider (FSP) for damage to his property, after discovering a leaking pipe
at the property in November 2013. The applicant undertook to provide further
information about the damage once the property had dried out.
In October 2014, the applicant notified the FSP that further leaks had been identified
in a sewer pipe at the property and sought cover for cracking and movement damage
caused by the effects of water escaping from the leaking pipes.
The FSP denied the claim on the basis that the damage was caused by factors which
are excluded under the policy, such as earth movement, gradual deterioration and
corrosion.
1.2 Issues and key findings
Is the FSP liable for the damage to the property?
The FSP is not liable for the cracking and movement damage to the property as the
damage occurred due to earth movement in circumstances which do not fall within
the limited scope of cover provided under the policy.
Even if it is accepted that the proximate cause of the damage was a leaking pipe, the
damage did not occur with the period of 72 hours required under the policy in order
for cover to apply.
1.3 Determination
This determination is in favour of the FSP.
The FSP is not liable for the damage to the applicant’s property .
Case No: 400346 Determination Page 2 of 7
2 Reasons for determination
2.1 Is the FSP liable for the damage to the property?
Applicant has established a prima facie claim
The applicant is required to show that, on the balance of probabilities, he has
suffered a loss caused by a risk insured against under the policy. This is known as a
prima facie claim.
If the applicant is able to establish a prima facie claim, then the onus shifts to the
FSP to show that, on the balance of probabilities, it is entitled to rely on an exclusion
under the policy to deny the claim.
The applicant’s policy provides cover for accidental loss or damage to his home,
subject to the conditions and exclusions set out in the policy. The courts have defined
“accidental” in this context to mean “unintended and unexpected”.
The reports provided by the engineers (RH and IC) appointed by the parties confirm
that there is cracking and movement damage to various parts of the property.
In particular, the applicant’s engineer (RH) observed differential settlement of the pad
footing of a supporting column located adjacent to the kitchen at the south-east
corner of the property. RH advised that the cartwheel failure of the pad footing had
caused the column to rotate, resulting in cracking and movement damage in that
area.
The applicant has provided an invoice from his plumber (NP) which establishes that
NP identified and repaired three breaks in the sewer pipe near the south-east corner
of the property in September 2014. A leak in the copper water pipe under the laundry
had previously been repaired some months earlier.
Given the identified leaks and the nature of the damage, the FSP accepts that the
applicant has established a prima facie claim for accidental damage under the policy.
Accordingly, the FSP bears the onus of establishing that, on the balance of
probabilities, it is entitled to rel y on a policy exclusion to deny the applicant’s claim.
Policy provides limited cover only for earth movement
As outlined above, the applicant’s policy provides br oad cover for accidental damage.
However, the policy excludes cover for earth movement no matter how caused
(including by erosion, settling or shrinkage), except where the claimed damage
occurs as a direct result of an earthquake or water leaking from a fixed pipe.
Where damage occurs due to earth movement resulting from a water leak, cover is
only provided if the damage occurs within 72 hours of the leak. A limit of $10,000 per
claim also applies.
Based on reports provided by its engineer (IC), the FSP says that the cracking and
movement damage to the applicant’s property was caused by earth movement due to
naturally occurring changes in the moisture content of the foundation soils.
Case No: 400346 Determination Page 3 of 7
T he FSP’s engineer (IC) considered that the large number of trees in the bushland
surrounding the property had drawn moisture from the foundation soil, causing the
soil to dry out and resulting in downwards movement (settlement).
Accordingly, the FSP says it is entitled to deny the applicant’s claim based on the
exclusion for earth movement, as the damage was not the direct result of a leaking
pipe.
The applicant disputes the findings of the FSP’s engineer. He has provided reports
from his own engineer (RH) which state that the damage was caused by earth
movement which occurred as a direct result of a leaking pipe.
FSP’s liability depends on cau se of damage
Under the terms of the policy, the FSP will only be liable for the cracking and
movement damage to the applicant’s property if:
the proximate cause of the damage was the effects of water from a leaking
pipe; and
the damage occurred within 72 hours of the leak.
The proximate cause is the dominant, efficient or operative cause of the damage.
However, it is not required to be the sole cause or the last in time.
The identification of the proximate cause is a question of fact that depends on the
circumstances of each particular case.
Engineers have provided differing opinions
As outlined above, both engineers agree that the cracking and movement damage
was caused by differential movement of the foundations due to changes in the
moisture content of the soil at the property.
However, the engineers have provided differing opinions about what caused the
moisture variation in the soils which led to the differential foundation movement.
Further, it appears that the views of both engineers have shifted over time.
In his earlier reports, the applicant ’s engineer (RH) advised that the significant
damage to the south-east corner of the property had been caused by the effects of
water leaking from the broken sewer pipe nearby which had compromised the
bearing capacity of the foundation soil, causing a “cartwheel failure” of the pad
footing under the supporting column.
RH considered that the breaks in the sewer pipe had occurred as a result of non-
uniform movement of the earth around the pipe, which had been caused by water
escaping from the leaking copper water pipe under the laundry (which had been
repaired some months earlier).
RH explained that, given the slope of the site, the leaking water from the copper pipe
would have seeped through the soil and become trapped in the aggregate material
around the sewer pipe.
On this basis, it would appear that RH considered the proximate cause of the
damage to be the escape of water from the copper water pipe under the laundry.
Case No: 400346 Determination Page 4 of 7
Photographs of the damaged section of the water pipe show that it was severely
corroded.
However, in his later reports, RH suggested that the effects of water leaking from the
copper water pipe were not relevant and the only causative factor was the leaking
sewer pipe which had caused the bearing failure at the south-east corner of the
property.
It does not appear that RH carried out any further inspections of the property before
preparing his later reports. In these circumstances, it is unclear why he appears to
have changed his view about the causation mechanism.
RH separately identified settlement of one of the stumps under the dining room as
having been caused by the effects of water leaking from the corroded water pipe.
However, he also indicated that this damage was not the subject of the current claim.
For his part, the FSP’s engineer (IC) initially concluded that all of the cracking and
movement damage to the property had been caused by ongoing naturally occurring
earth movement, exacerbated by the leaking pipes.
However, in his later reports, IC advised that, following a review of current and
historical aerial photographs of the site, he had changed his mind and no longer
considered that the leaking copper water pipe and/or the leaking sewer pipe had had
any effect.
IC considered that the sole cause of the differential movement was the drying effect
of the vegetation surrounding the property, which had caused settlement of the
reactive clay foundation soils.
Damage did not occur within 72 hours of leak
As outlined above, the engineers appointed by the parties have provided various
opinions regarding the proximate cause of the cracking and movement damage at
the property.
The reports and photographs provided by the engineers confirm that there is cracking
and movement damage of varying severity throughout the property. The nature and
location of this damage is indicative of ongoing differential movement due to naturally
occurring changes in the moisture content of the foundation soils.
The applicant’s engineer (RH) acknowledged this in his initial report when he
described much of the observed damage as “normal” for a building of the relevant
age and type.
However, I accept that the damage to the south-east corner of the property (in
particular) appears more severe and is localised to the area where the breaks in the
sewer pipe were identified. This suggests the damage may have been caused by
water leaking from the pipe.
Nevertheless, regardless of which of the various expert opinions is accepted, I am
not satisfied that the claimed damage to the property occurred within 72 hours of the
leaking pipe.
Case No: 400346 Determination Page 5 of 7
The nature of the claimed damage is such that it would have occurred gradually over
an extended period of time as water from the sewer pipe seeped into the surrounding
soil in the course of ordinary usage, causing volumetric changes in the soil and
consequential differential movement of the footings .
The likely timeframe for t he damage would be further extended if, as the applicant’s
engineer (RH) initially advised, it occurred as a consequence of water leaking from
the copper pipe which affected the soil around the sewer pipe, causing the
breakages identified in September 2014.
To the extent that damage has occurred as a direct result of water leaking from the
corroded copper pipe itself, I am not satisfied that this damage occurred within 72
hours of the leak occurring. Further, the policy excludes cover for damage where the
proximate cause of the loss is gradual deterioration of corrosion.
FSP is not liable for applicant’s claim
For the reasons outlined above, I consider that the claimed damage occurred due to
earth movement of a type which is excluded under the policy.
Even if I accept that the proximate cause of the damage was a leaking pipe, I am not
satisfied the damage occurred within 72 hours of the leak as required in order for it to
be subject to cover under the policy.
I do not agree with the applicant that the drafting of the earth movement exclusion is
ambiguous.
In my view, the exclusion is expressed clearly and reflects the commercial intention
that cover for damage resulting from earth movement will be covered only in very
limited circumstances (namely, where the cause is an earthquake or a leaking pipe
and the resulting damage occurs within the 72 hour period specified).
The wording of the exclusion makes clear that the policy is not intended to provide
cover for damage resulting from earth movement which occurs gradually as result of
a water leak over an extended period of time.
Accordingly, the FSP is entitled to rely on the exclusion for earth movement to deny
the applicant’s claim.
Case No: 400346 Determination Page 6 of 7
3 Supporting information
3.1 FOS approach to this dispute
FOS has considered it appropriate to expedite this dispute in accordance with the
Operational Guidelines to the FOS Terms of Reference, due to the nature of the
dispute. Accordingly, this dispute has not been the subject of a FOS preliminary view
and has proceeded directly to determination.
This case has been decided on its merits, having regard to the relevant law, good
industry practice, codes of practice and previous FOS decisions.
There has been a full exchange of all material information relied on for the purposes
of this determination and each party has had the opportunity to address any issues
raised by the other. All of the material provided by the parties has been reviewed and
considered.
While the parties have raised numerous issues in their submissions, for the purposes
of this determination, commentary has been restricted to those issues which are
considered directly relevant to the outcome only.
3.2 Policy documents
For the purpose of assessing its liability for t he applicant’s claim, the FSP has re lied
on the terms of the policy, as set out in a Product Disclosure Statement (PDS)
prepared on 20 February 2009 and amended by a Supplementary Product
Disclosure Statement (PDS) prepared on 21 December 2011.
The FSP has provided systems information which indicates that a copy of the SPDS
was sent to the applicant in March 2013, together with documents relating to the
renewal of his policy for the period of insurance commencing 17 May 2013 (being the
period during which the loss occurred). The applicant says he has been unable to
locate a copy of the SPDS, but has not specifically denied receiving it.
In these circumstances, I am satisfied that the FSP is entitled to rely on the terms of
the policy as set out in the PDS and SPDS (see 3.3 below).
3.3 Terms of policy
Subject Terms
Scope of
cover
This policy insures You against accidental damage, burglary and theft occurring
during the Period of Insurance.
Exclusion –
earth
movement
This policy does not insure You against:
earth movement no matter how caused, including erosion, vibration,
subsidence, seepage, saturation, creeping, landslip, mudslide, collapse,
shrinkage, settling, expansion or heaving unless the loss or damage occurs as
a direct result of:
- earthquake; or
Case No: 400346 Determination Page 7 of 7
Subject Terms
- wat er overflowing, leaking or bursting from a fixed pipe or fixed system and
that loss or damage occurs wit hin 72 hours of such overflowing, leaking or
bursting.
In respect of (b) above We only pay up to $10,000 for any one claim.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.