Claim denial: pool cracking and buckling attributed to earth movement and faulty design
Text of the determination
Determination
Case No: 392494 Determination Page 1 of 7
Case number : 392494 7 September 2015
1 Overview
1.1 Dispute
The Applicants lodged a claim under their home insurance policy with the Financial
Services provider (FSP) for cracking and buckling damage to an in ground fibreglass
swimming pool at their property. The Applicants believe the damage was caused by
a leaking pipe.
The FSP denied the Applicants’ claim on the basis that the damage was not caused
by the leaking pipe but by naturally occurri ng earth movement, which is excluded
under the policy. The FSP also says the policy does not provide cover for cracking
damage.
The Applicants dispute the FSP ’s decision and seek cover for costs incurred in
repairing the pool. They also seek compensation for non-financial loss due to the
manner in which the FSP has handled their claim.
1.2 Issues and key findings
Is the FSP liable for the damage to the pool?
The available information establishes that, on the balance of probabilities, the
damage to the pool was caused by the expansion of the surrounding soils due to
naturally occurring changes in moisture content, exacerbated by the absence of a
suitable drainage system. Accordingly, the FSP is entitled to rely on the policy
exclusions for damage caused by naturally occurring earth movement and/or faulty
design or workmanship to deny the Applicants’ claim.
Are the Applicants entitled to compensation?
The FSP managed the Applicants’ claim reasonably overall. Accordingly, the
Applicants are not entitled to compensation.
1.3 Determination
This Determination is in favour of the FSP.
The FSP is not required to reimburse the Applicants for the repair costs . The
Applicants are not entitled to compensation.
Case No: 392494 Determination Page 2 of 7
2 Reasons for Determination
2.1 Is the FSP liable for the damage to the pool?
Policy provides cover unless FSP can show an exclusion applies
The Applicants are required to show that, on the balance of probabilities, they have
suffered a loss caused by a risk insured against under the policy. This is known as a
prima facie claim.
If the Applicants are able to establish a prima facie claim, then the onus shifts to the
FSP to show that, on the balance of probabilities, it is entitled to rely on an exclusion
under the policy or is otherwise entitled to deny the claim.
The Applicants ’ policy provides cover for accidental damage to their home during the
period of insurance. The courts have defined “accidental” in this context to mean
“unintended and unexpected”.
The Applicants say the damage to their pool was caused by a leaking solar hot water
pipe, which led to excess water accumulating under the pool resulting in a build-up of
pressure which caused the cracking and buckling damage to the floor of the pool.
The FSP accepts that the Applicants’ pool suffered cracking and buckli ng damage in
February 2012. This damage is clearly evident in the photographs taken by the FSP’s
building consultant in April 2014. There is no suggestion that this damage was
anything other than unintended and unexpected.
On this basis, I am satisfied that the Applicants have established a prima facie claim
for accidental damage under the policy.
In these circumstances, the FSP bears the onus of establishing that, on the balance
of probabilities, it is entitled to rely on a policy exclusion to deny the Applicants’ claim.
The FSP says that it is not liable because the damage to the pool was caused by one
or more of the following factors, each of which is excluded under the policy:
earth movement (including seepage, saturation, shrinkage, settling, expansion
or heaving), no matter how caused; and/or
a structural fault, faulty design or faulty workmanship.
The FSP also notes that the policy specifically excludes liability for cracking damage,
except where the damage has been caused by fire, lightning, earthquake, storm,
explosion, burglary, theft, vandalism or the impact of a vehicle or aircraft.
In order to establish an exclusion applies, the FSP must show that the proximate
cause of the damage to the Applicants’ pool (that is, the real, effective or dominan t
cause) was one or more of the excluded factors outlined above.
FSP’s expert found damage was caused by earth movement
The building consultant (TDG) appointed by the FSP to inspect the damage to the
Applicants’ swimming pool in April 2014 concluded that the damage had been
Case No: 392494 Determination Page 3 of 7
caused by the expansion of the surrounding clay soils, which placed pressure on the
fibreglass walls and floor of the pool.
TDG noted that the pool had been bought second hand and installed by the
Applicants with the assistance of a local pool installation contractor. The pool had
been installed in reactive clay foundation soils, surrounded by rigid backfill material,
comprising a mixture of crushed rock and cement.
TDG advised that:
at the time the pool was installed in November 2010, the surrounding clay soils
would have been relatively dry due to a lengthy drought;
when subsequent rainfall occurred, this caused the clay foundation soils to
expand and the perched water table to rise rapidly, exerting lateral pressure on
the rigid backfill material and creating a build-up of pressure around the pool
shell; and
once the external pressure exceeded the internal water pressure, this would
have caused the walls and floor to crack and buckle inwards.
TDG considered that the pool would also have been subject to additional pressure
(hydrostatic pressure) caused by water accumulating under the pool shell, as the
hole excavated to hold the pool formed a sump collecting surface run-off and
groundwater (which in turn would have infiltrated the soils around the pool, causing
them to expand further).
In summary, TDG concluded that the damage to the pool was inevitable, given the
manner in which it had been installed, which did not include any provision for sub-soil
drainage around the perimeter of the pool.
TDG provided copies of extracts from the Australian Standards for the design and
installation of in ground fibreglass swimming pools which require appropriate
drainage to be provided, having regard to local environmental conditions (including
potential loadings generated by reactive clay soils and hydrostatic pressure arising
where the groundwater table may rise above the level of the pool floor).
Given the conditions in which the pool was installed, TDG considered that, in addition
to the hydrostatic valve in the floor of the pool, a full perimeter sub-surface drainage
system should have been installed (including a deep pit with an automatic float
pump) to provide a discharge point for accumulated stormwater run-off and
groundwater, thereby preventing the build-up of pressure around the pool. TDG also
noted that adequate allowance should have been provided around the backfill
material to accommodate ongoing seasonal movement of the surrounding clay soils.
Th e Applicants dispute TDG’s findings that the damage was caused by naturally
occurring earth movement. They say that TDG did not take any soil samples or
perform any other testing or exploratory work to substantiate his conclusions.
However, it is apparent from TDG’s reports that his understanding of the manner in
which the pool was installed (including the limited drainage provisions and the use of
backfill material) was based on information provided by the Applicants, who had been
directly involved in the relevant works. Further, TDG’s conclusions about the nature
of the surrounding soils was based on his observation of the excavated material,
which had been dumped in a nearby paddock.
Case No: 392494 Determination Page 4 of 7
The Applicants also say the installation of the pool (including the drai nage provisions)
complied with all applicable specifications and requirements. However, they have not
provided any independent information confirming this, and have not specifically
addressed the provisions of the relevant Australian Standards referred to by TDG.
Having carefully reviewed TDG’s initial and supplementary reports, I consider that
they provide a logical and rational explanation of how the damage to the Applicants’
swimming pool occurred, which is consistent with the observed facts. In particular,
the nature of the cracking and buckling damage to the pool is consistent with the
damage having been caused by the effects of external pressure on the floors and
walls of the pool.
However, the Applicants say that, even if the damage to the pool was caused by
earth movement and/or hydrostatic pressure, this was due to the accumulation of
water around the pool due to a leaking solar hot water pipe.
Available information does not establish leaking pipe caused damage
After the FSP initially investigated and denied the Applicants’ claim, the Applicants
arranged for the repair of the cracking and buckling damage to the pool at their own
cost. However, following completion of these repairs, the Applicants noticed that the
water level in the pool was continuing to drop.
The Applicants’ pool repairer advised that this was due to a problem with the solar
hot water pipes, which ran from the roof of the house to the corner of the pool where
the spa jets were located.
The FSP appointed a pool specialist (LF) who confirmed that the pool appeared to be
leaking from the solar return pipes. However, it was not possible to determine exactly
where the pipes were leaking (or what had caused the leak) without excavating the
area around the pipes. Attempts to obtain further information using CCTV were
unsuccessful.
The Applicants’ policy provides an additional benefit for the cost of investigating a
leaking pipe and repairing any damage caused by the investigation. However, this
benefit is capped at $2,500.
The FSP advised the Applicants that it would reimburse them for the costs of any
further investigations, if the leaking pipe was found to have caused the damage to
the pool. However, the Applicants decided not to proceed, given the cost of
excavating the pool surrounds and paving was estimated at over $40,000.
As a result, there is limited information available about the nature and extent of the
damage to the leaking pipe (including the volume of water likely to have been
released) and its likely effects on the surrounding soils. The Applicants have not
provided any independent information addressing these issues.
Further, it is not possible to establish when and how the damage to the pipe
occurred. The FSP’s building consultant (TDG) has noted that it is likely the pipe wa s
sheared off at the entry point into the pool, when the pool cracked and buckled in
February 2012.
Case No: 392494 Determination Page 5 of 7
When TDG inspected the pool in April 2012, he found that the northern end (where
the solar pipes were connected) was approximately 22 millimetres higher than the
remainder, suggesting that it may have lifted due to hydrostatic pressure, in turn
damaging the solar pipes. However, it was not possible to determine this conclusively
without further investigations.
In these circumstances, I am not satisfied that there is sufficient information available
to show that the leaking pipe was the proximate cause of the damage to the
Applicants’ swimming pool.
FSP is entitled to rely on policy exclusions
Having carefully reviewed the available information, I am satisfied that, on the
balance of probabilities, the damage to the Applicants’ swimming pool was caused by
the expansion of the surrounding soils due to naturally occurring changes in moisture
content, exacerbated by the absence of a suitable drainage system.
Accordingly, the FSP is entitled to rely on the policy exclusions for damage caused
by naturally occurring earth movement and/or faulty design or workmanship, in order
to deny the Applicants’ claim.
As noted above, there is limited information available about the potential impact of
water leaking from the damaged solar hot water pipe, due to the costs involved in
undertaking further investigations.
However, I am satisfied that, even if the leaking pipe was considered to have caused
or contributed to the accumulation of water around the pool shell, the FSP would be
entitled to deny the Applicants’ claim based on the Wayne Tank principle.
The Wayne Tank principle is an established principle of insurance law which provides
that, where a loss is caused by two proximate causes operating concurrently and
interdependently and one is excluded while the other is not, the exclusion clause
operates to allow the insurer to deny the claim in its entirety.
In the present case, the FSP’s building consultant (TDG) has advised t hat, had an
appropriate drainage system been installed, it is likely that any water which
accumulated around the pool (including water from a leaking pipe) could have been
removed promptly, thereby preventing any damage to the pool shell.
Based on TDG’s report, I accept that, even if water was leaking from the damaged
pipe, the accumulated water would not have resulted in damage to the pool shell had
suitable drainage measures been put in place.
In this event, the leaking pipe and the faulty design of the pool would have operated
interdependently and concurrently to cause the claimed damage. As the policy
excludes damage caused by faulty workmanship, the FSP would still be entitled to
deny the claim, in accordance with the Wayne Tank principle.
Case No: 392494 Determination Page 6 of 7
2.2 Are the Applicants entitled to compensation?
Applicants are not entitled to compensation
Under paragraph 9.3(a) of the Terms of Reference, FOS may award an amount of
compensation (capped at $3,000) for non-financial loss where an applicant has
suffered an unusual degree or extent of physical inconvenience, time taken to
resolve the situation or interference with their expectation of enjoyment or peace of
mind.
However, FOS expects applicants to be moderately robust and bear the usual stress
and inconvenience associated with an insurance claim.
Having carefully reviewed the claim history, the Panel is satisfied that the FSP has
acted reasonably overall in the management of the Applicants’ claim.
After the Applicants lodged their claim, the FSP acted promptly to appoint a building
consultant (TDG) to determine the cause of the damage. In the absence of any
additional information, the FSP was entitled to rely on TDG’s findings to deny the
Applicants’ claim.
When the Applicants subsequently notified the FSP that a leaking pipe had been
discovered, the FSP took reasonable steps to investigate the leaking pipe, and
sought further comment from TDG.
The FSP was not required to undertake further and more extensive investigations,
given the costs involved and in light of TDG’s advice that, even if the leaking pipe
were found to have contributed, the damage would not have occurred had adequate
provision for drainage been made.
The claim history suggests that there was a delay of almost eighteen months
between the date the FSP reconfirmed its denial of the Applicants’ claim following
further advice from TDG in October 2014, and the FSP’s appointment of a pool
specialist to reinspect the pool.
However, the FSP was not solely responsible for this delay. The available informa tion
indicates that the Applicants initially advised that they would obtain a report from their
own engineer to refute TDG’s findings. When this did not occur, the FSP took steps
to appoint a pool specialist.
For the reasons outlined above, I am satisfied that the FSP was entitled to deny the
Applicants’ claim. In these circumstances, I am not satisfied that any delays on the
part of the FSP are sufficient to justify the award of compensation for non-financial
loss.
Case No: 392494 Determination Page 7 of 7
3 Supporting information
3.1 FOS approach to this Determination
This Determination follows the review of a Recommendation issued on behalf of the
Financial Ombudsman Service (FOS) on 17 July 2015. The Recommendation was
rejected by the Applicant.
This case has been decided on its merits, having regard to the relevant law, good
industry practice, codes of practice and previous FOS decisions.
There has been a full exchange of all material information relied on for the purposes
of this Determination and each party has had the opportunity to address any issues
raised by the other. All of the material provided by the parties has been reviewed and
considered.
While the parties have raised numerous issues in their submissions, for the purposes
of this Determination, commentary has been restricted to those issues which are
considered directly relevant to the outcome only.
3.2 Terms of policy
Subject Terms
Accidental
damage cover
This policy insures You against accidental damage, burglary and theft
occurring during the Period of Insurance.
Additional
benefit – escape
of liquid
If liquid overflows, leaks or bursts from a fixed system at Your Home during
the Period of Ins urance and damages or is likely to damage insured property,
We pay for the reasonable cost to investigate the caus e of damage or likel y
damage. We pay up to $2,500 for this benefit.
We do not pay to repair or replace any faulty part identified by the
investigation, but We pay the cost to repair any damage directly caused by
the investigation.
General
exclusions
Your policy does not insu re You against:
damage directly caused by … earth movement (except earthquake) no
matter how caused, including erosion, vibration, subsidence, seepage,
saturation, creeping, landslip, mudslide, collapse, shrinkage, settling,
expansion or heaving …
damage d irectly or indirectly caused by or arising out of … a structural
fault, faulty design or faulty workmanship …
cracking (other than cracking of a bath tub, shower recess, wash basin,
sink, toilet bowl and cistern), chipping, splitting, tearing, scratching o r
denting unless caused by fire, lightning, earthquake, storm, explosion,
burglary, theft, vandalism or impact by a vehicle or aircraft
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.