Home / Financial Firm (Unknown - Insurer) / Determination 389302
Determination 389302
Claim denied for boundary fence and retaining wall collapse, no insured event
Summary
The applicants claimed for a retaining wall and fence that collapsed beside an excavator working on a neighbouring driveway. AFCA found no impact or storm cause, that ground movement was the most likely cause and is excluded, and that the FSP need not fund make-safe works.
The applicants bear the onus to establish an insured event under a defined-events policy, and ground movement and retaining walls are specifically excluded.
Subjects and remedies
home or building damageno remedy
Text of the determination
Determination
General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of
Claim - No Insured Event
Determination
Case No: 389302 Determination Page 1 of 8
Case number : 389302 2 9 May 2015
1 Overview
1.1 Dispute
The Applicants lodged a claim on their home and contents policy for damage
caused to a boundary fence and retaining wall on 1 September 2014. The y allege
the damage was caused by an excavator used on an adjacent property.
The Financial Services Provider (FSP) denied the claim on the basis that there
was no insured event to account for the damage. The closest likely event was
“impact” but there was no impact with the damaged areas. Other possible
contributing factors were also not covered under the policy.
The parties seek a Determination on the decision to deny the claim.
1.2 Issues and key findings
Was the loss caused by an insured event?
The Applicants have not established a loss caused by an insured event because:
the policy is a defined events policy
whilst the policy provides cover for damage caused by impact, the evidence
does not establish that the loss was due to impact
whilst the policy provides cover for damage caused by storm, the policy
specifically excludes loss or damage to retaining walls caused by storm
the loss was most likely caused as a result of ground movement possibly
associated with the wet soil and poor design of the retaining wall.
1.3 Determination
This Determination is in favour of the FSP.
The FSP is entitled to refuse payment of the Applicants‟ claim in accordance with
the terms and conditions of the policy.
Case No: 389302 Determination Page 2 of 8
2 Reasons for Determination
There has been a full exchange of material between the parties and each party
has had the opportunity of addressing the issues that arise from the material
exchanged.
This Determination follows consideration of the information exchanged and is
based on what is fair in all the circumstances having regard to relevant legal
principles, terms of the policy, good industry practise and where applicable prior
Determinations
2.1 Was the loss caused by an insured event?
The loss was not caused by an insured event
The Applicants bear the onus to establish that their loss was caused by an
insured event.
There is no dispute that the Applicants were provided with a copy of the policy
from the FSP or that the Applicants had been clearly informed of the terms and
conditions of the policy.
The policy provides cover for a series of defined events. Relevant to the
Applicants‟ claim, were defined events associated with:
loss or damage caused by storm
loss or damage caused by impact.
It is the Applicants‟ contention that the damage to their retaining wall was caused
by the impact of the excavator against the boundary fence and by extension, to
the retaining wall.
In the alternative, the Applicants believe the failure of the wall may be due to
ongoing storm conditions through the period, which left the soil wet and conducive
to failure.
Circumstances of the loss
There is no dispute that the Applicants ‟ boundary fence and retaining wall
collapsed on 1 September 2014. The retaining wall and fence backed on to a
battle axe driveway that led to a neighbouring property. At the time of the
collapse, work was being performed along the driveway installing services to the
neighbouring property. An excavator was working in close proximity to the area
where the wall collapsed.
Expert Evidence
As there was work on the battle axe driveway at the time of the collapse an
investigation was conducted by the relevant Workcover authority as to the likely
cause of the damage and the safety of the area.
Case No: 389302 Determination Page 3 of 8
The Workcover report notes that the excavator had travelled up and down the
battle axe driveway once on the morning of 1September 2014. At the time of the
collapse, it was operating approximately five metres from the fence and retaining
wall, digging a 0.5 of a metre trench. The report provided no evidence to link the
use of the excavator to the failure of the retaining wall.
The FSP obtained a report from a consulting engineer DWK. DWK formed a view
that there was no apparent impact between the excavator and the retaining wall to
account for its failure. DWK considered the construction of the wall which was a
heron wall was not in accordance with relevant Australian standards.
DWK identified three likely contributing causes for the loss:
(a) Poor adherence to construction protocols, due to an inadequate geogrid
length situated behind the blockwork, leaving the structure vulnerable to
failure
(b) Surcharge loading from the use of the excavator on the neighbouring
property. The excavator (estimated to exert about 10kPa) exceeded the
design limits for the retaining wall (5kPa)
(c) Saturation of the clay soil behind the retaining wall from the heavy rainfalls
through the preceding month.
Whilst DWK did not consider there was any evidence of impact, he agreed that
possibly the weight of the excavator was too great for the battle axe driveway
given recent rain that allowed the surrounding soil to have become saturated. He
believes this may have contributed to the failure of the retaining wall.
The Applicants obtained reports from the retaining wall‟s builder (“SS”) and
another builder (“PS”) to say the construction of the wall was not contrary to
relevant building standards. PS considered the construction to be compliant with
the relevant regulations and not a factor in the wall‟s failure.
PS was of the view the collapse of the retaining wall was “most likely” caused by a
collision between the excavator and the fence bordering the two properties. The
footings for this fence went about 600mm into the ground and were likely pushed
“inwards and downwards into the retaining wall”, leading to its failure.
In a further report following consideration of the comments made by SS and PS,
DWK has confirmed on review of all documentation that:
there was no evidence of impact between the excavator and the fence
to comply with Australian standards, the heron wall relies on a system of
blocks and geogrid soil reinforcement. Images of the retaining wall do not
show any evidence of geogrid reinforcement and it appears the requirements
of the heron system had not been adopted
the most likely cause of damage was ground movement which is excluded
under the policy.
No evidence of an “impact” related incident
Although there are differing opinions as to whether there was evidence of impact,
in my view, the view expressed by DWK and that of WC is to be preferred.
Case No: 389302 Determination Page 4 of 8
Although the policy does not define impact, the general meaning provided to the
word and consistent with the definition in the Macquarie Dictionary is:
“the striking of one object on another or forcible contact”.
There is limited evidence of any actual impact between the excavator and the
retaining wall or fence.
In my view whilst I accept it is possible that the use of the excavator in the area
may have contributed to the collapse, it was not impact that caused the collapse
of the retaining wall.
No evidence of storm damage
Insofar as the Applicants believe the damage may be storm related, I note that
there is no evidence of any storm. Although there may have been heavy rain, this
is not evidence of storm. Even if there was evidence of storm, the policy
specifically excludes under storm cover damage to retaining wa lls.
Conclusions
In my view, the most likely cause of the collapse of the retaining wall and fence is
ground movement due to a combination of the weight of the excavator and the
subsequent surcharging load, the softening of the soil surrounding the area due to
recent rains and the inadequate construction of the retaining wall.
Damage due to ground movement is specifically excluded from cover under the
terms of the policy.
In the circumstances, whilst I accept that the Applicants are no way at fault for the
damage, I am not satisfied that the Applicants have established that the damage
or loss sustained has been caused as a result of an event insured under the
terms of the policy.
I am satisfied the FSP is entitled to rely upon the terms and conditions of the
policy to refuse payment of the claim.
No obligation on the FSP to meet “ make safe ” requirements
The Applicants consider that the FSP should have done more in assisting with
“make safe” repairs required to the retaining wall after the event.
I accept the policy provides cover for “make safe” repairs. This benefit is only
present where a loss is incurred as a result of an insured event.
As I am not satisfied the Applicants have established an insured event occurred,
then the FSP is not obliged to cover the Applicants for the “cost of make safe”
repairs.
Case No: 389302 Determination Page 5 of 8
3 Supporting information
3.1 Relevant expert reports
Record Key points
Assessor’s report ( DG )
2 September 2014
Male Applicant received a call from their neighbour to say
that the retaining wall had come down. He returned home
and found an excavator next door .
Colourbond fence was leaning over and retaining wall had
collapsed .
Applicants thought the damage was caused by rain or by
the construction work at the neighbouring property .
Believed excavator may have hit the fence .
No evidence of impact damage with the fence .
Suggested by internal supervisor for FSP that the retaining
wall was not “built correctly and this is the reason why it
has fallen”.
Inspection report (WC)
3 September 2014
Inspected neighbour‟s driveway where excavator was
used .
Driveway was of “battle axe” construction and adjoined
three properties .
Edge of Applicant‟s retaining wall about 1m from driveway
cement on worksite .
Excavator had been trenching middle of driveway (about
five metres awa y) at time of collapse. Handwritten notes
suggested it was only two metres away.
Builder report (PS)
13 October 2014
The retaining wall on the Applicants‟ property is 800mm
from the base of the wall to the inside of the rear boundary
fence .
Height of the wall varied from 400mm to 1.7m at the
highest point .
The retaining wall was “constructed in accordance with
the… manufacturer‟s recommendations and to Australian
Standards .
At the site there was “strong evidence of heavy
construction machinery being used i n very close proximity
to the fence line” .
The collapse of the retaining wall is “most likely” the result
of a collision bet ween the excavator and the colou r bond
fence. The footings for this fence went about 600mm into
the ground and were likely pushed “inwards and
downwards into the retaining wall” .
Inspection of the wall “indicates a force that is not natural”
was the cause:
(a) The fence has an apparent “specific point of impact”
(b) Some of the 22kg blocks have been pushed up to 3m
into the property
(c) There was no indication of movement, cracking or
Case No: 389302 Determination Page 6 of 8
deterioration prior to the event
(d) The bottom two rows of blocks are still secure, and
(e) The bottom row is still cemented into place on the
concrete footing.
The geotextile material used was still in place in th e
ground, along the inside of the wall. This “indicates that the
natural ground had not moved or collapsed on the inside
the retaining wall, further indicating that the wall had been
interfered with ”.
Consulting engineer’s
report ( D W K )
31 October 2014
The site has a slight natural slope from the rear to the front.
It has a two - storey home on the block, with an in ground
pool and pool house .
The retaining wall is on the rear northern side of the
property. The wall was constructed wholly within the
Applicant s‟ property in or around February 2011. It was a
concrete block work construction .
The metal fence and the retaining wall itself collapsed at
the same time .
The northern boundary area of the property is
approximately 14.5m long from the western to the east ern
side .
Damage or distress to the wall consists of: lateral southerly
inwards rotation of the western end, where the wall is
1.75m high over 2.5 m - 4.5m and complete inwards collapse
of the remainder of the wall to the eastern end (length of
about 10 m - 12m) .
Construction consists of (a) hollow concrete blocks filled
with gravel (b) gravel backfill (c) concrete strip footing and
(d) drainage agricultural - line to the rear base of the wall .
The damaged metal fence was 1.8m high, set back from
the retaining wall by about 600mm (maximum) .
Exposed natural ground consists of soil over clay .
The WC report noted that the excavator was not adjacent
to the Applicants‟ retaining wall at the time of the collapse –
it was about 5m away. WC found no evidence to link the
wor k at the neighbouring site to the retaining wall‟s
collapse .
A 7 - tonne excavator exerts about 10kPa, whereas the
Applicants‟ retaining wall “is designed for surcharge loads
up to 5kPa” .
The type of retaining wall built relies upon a “geogrid
system” extend ing for a certain length behind the rear of
the retaining wall blocks. For a height of 1.4m - 1.75m the
“geogrid length required is approximately 1.7m to 2.2m
depending on the soil type”. Assuming 200mm embedment
within the blockwork, this means a width of 1 .5m - 2.0m is
required .
The width from the rear of the retaining wall blocks to the
metal fence was about 600mm maximum. This is
significantly less than what is required .
Case No: 389302 Determination Page 7 of 8
185mm of rain fell through the month of August prior to the
collapse. Rainfall for this month was about three times
higher than the historical monthly average .
The overall construction was “not considered to be
sufficient to withstand the retained soil loads” .
The observed damage is “consistent with lateral loading
beyond the capacity of the retaining wall system” .
Three issues contributed to the damage, including:
(a) Poor construction due to the inadequate geogrid
length behind the blockwork
(b) Surcharge loading from the excavator which
exceeded the design limits for the retaining wall
(c) Saturation of the clay soil from heavy rainfall through
the month of August 2014.
Supplementary
Engineer’s Report DWK
Review of all relevant documents.
No evidence of impact between the excavator and the
fence.
Based on Australian standards, a heron system wall relies
upon a system of blocks and geogrid soil reinforcement.
Images do not show geogrid reinforcement. It appears that
the requirements of heron system have not been adopted.
Most likely cause of damage is ground movement,
specifically excluded under the policy.
3.2 Relevant policy clauses
Pages 16-23 of the Product Disclosure Statement (PDS):
“ What you are covered for – Insured Events
We cover you for loss or damage to the building caused by an insured event which
happens during the period of cover. There are some things we do not cover and these
are shown in the „We do not cover‟ section of the following tables...
…
Storm
We cover We do not cover
Loss or damage to the building caused by
a storm.
…
loss or damage to retaining walls,
garden borders and free standing
outdoor walls…
…
Impact
We cover We do not cover
Loss or damage to the building caused by
impact at the insured address from:
a falling tree or part of a falling tree
including the roots;
power poles;
TV antennas or satellite dishes,
…
Case No: 389302 Determination Page 8 of 8
communication aerials or masts;
watercraft, aircraft, motor vehicles or
trailers;
an object falling from a motor vehicle or
aircraft;
space debris or meteorites.
…”
Page 26 of the PDS
“ …
Other Repair/Rebuilding Costs
We cover We do not cover
When rebuilding or repairing damaged
p arts of the building due to an insured
event, we will pay the reasonable and
necessary costs:
of any temporary work required to make
the damaged or destroyed building and
insured address safe;
…
…
…”
Page 34 of the PDS
“ What we do not cover – general exclusions cont’d
You are not covered under any section of your policy for damage, loss, cost or legal
liability that is caused by, arises from or involves:
…
Ground movement
erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage or any
other earth movement, but we will cover landslide or subsidence that is specifically
covered under the following insured events:
• „Storm‟;
• „Flood‟ (but only if you have cover for insured event „Flood‟);
• „Earthquake and Tsunami‟;
• „Explosion‟.”
Page 52 of the PDS
“ Retaining wall
means a wall, which is not part of the building, that holds back or prevents the movement
of earth. ”
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.