Home / Financial Firm (Unknown - Insurer) / Determination 388986

Determination 388986

Denial of claim - exclusion/condition

FirmFinancial Firm (Unknown - Insurer)
Decided2015-06-12
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

Subsidence damage to a home was attributed to reactive clay drying from tree roots and a leaking stormwater pipe, and the claim was denied. AFCA found the damage was not caused by an insured event, that earthquake was not proven, and that section 46 of the Insurance Contracts Act gave no relief.

Under a defined events policy the insured must prove loss from a listed event, and gradual water escape or tree root action falls outside a sudden escaping water cover.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of Claim - Exclusion/Condition Determination Case No: 388986 Determination Page 1 of 8 Case number: 388986 2 June 2015 1 Overview 1.1 Dispute The Applicants’ claim relates to damage to their home, which is insured under a Home Insurance Policy, by the Financial Service Provider (FSP). The FSP denied the claim on the basis the damage was not caused by an insured event and was caused mainly by subsidence as a result of reactive clay soils drying out. The Applicants challenge this position and say all the damage was caused by sudden escape of water from the broken stormwater drainage pipe. The Applicants argue that, alternatively, subsidence may have occurred as a result of an earthquake. 1.2 Issue and key findings Can the FSP deny the claim? The FSP can deny the claim because:  the evidence confirms the damage was not caused by an insured event  the Applicants have not established that damage resulted from earthquake  section 46 of the Insurance Contracts Act 1984 (the Act) does not provide relief to the Applicants. 1.3 Determination This Determination is in favour of the FSP. The FSP is entitled to deny the Applicants’ claim and is not required to take any further action. Case No: 388986 Determination Page 2 of 8 2 Reasons for Determination 2.1 Can FOS rely on FSP’s submissions and expert materials? FOS decisions are based on all evidence provided and made on the balance of probabilities The Applicants argue several of the FSP’s arguments and its experts’ findings and opinions should be dismissed because they are speculative. Under the FOS dispute process, both parties may provide information that is hypothetical or speculative. This does not make the information invalid. The FOS dispute process considers all the material provided, with particular attention to expert material, regardless of whether it is proven fact or the opinion of a subject matter expert. There may be, in some instances, reasons to disregard particular opinions due to insufficient supporting evidence or a lack of subject matter expertise. FOS will consider all material provided by the parties and make decisions on the balance of probabilities. Namely, a decision based on what is the most likely to have occurred when weighing all the evidence and expert opinions provided. For these reasons, the Panel is satisfied FOS can rely on the expert material provided by both parties, in order to assess the merits of this dispute. 2.2 Can the FSP deny the claim? It is an accepted principle of general insurance law that the onus is on the insured to establish that they have suffered a loss caused by an event to which the policy responds. This is known as a prima facie claim. Once so established, the onus shifts to the insurer to prove the application of a policy exclusion. The Home Insurance Policy held by the Applicants with the FSP is a defined events policy. This means that not all loss and damage is automatically covered by the terms of the policy. Rather, only loss and damage caused by an event listed within the policy, is covered. As a result, the Applicants must first prove their loss was caused by one of the events listed in the policy. Evidence suggests damage was not caused by an insured event There are two areas of damage that may have had the same proximate cause: the damage in the area of the northwest external wall and along the east wall. The Applicants say the insured e vent of “escaping water” caused all the damage. The policy says this insured event covers “loss or damage to the insured property caused by water escaping suddenly and without warning”. Case No: 388986 Determination Page 3 of 8 The evidence indicates an underground stormwater drain pipe broke near the northwest corner of the building. It is unclear when this pipe broke or for how long it let water go into the ground. The Applicants say the crack in the downpipe could have been there for a substantial period of time before it was detected, but the i nitial crack incident must have occurred from a sudden event. They consider all damage may have occurred following a single, sudden water escape such as any rain downpour event and that any assertions as to the timeframe or rate of water escape (as in, long term) are speculative. The detail of the parties’ evidence is in section 3.2 below. A summary indicates: Record Summary of opinion Applicants’ builder  The storm drain that is broken has been leaking for a substantial amount of time.  It has caused the front northeast (sic) corner wall to sink and move and could be the cause of all movement in the house.  The proximity of the crack and the amount of water leaking over the course of a year would be enough to inundate the footing system. FSP’s building con sultant  The distress has resulted from shrinkage of the clay soil as a result of the drying action of trees.  The broken stormwater pipe is likely to have had a secondary influence on the movement and distress. It is unknown how long the pipe has been brok en.  There is lateral movement between the base and overlying brickwork along the northern end of the east wall. This distress is consistent with a possible leak or insufficiency in the plumbing services in this area. FSP’s plumber  There were no problems with water supply pipes or suspended sewer drainage pipes.  The front northwest corner stormwater drain is blocked and there is dampness at the north side brick wall/foundation area nearby.  There is damage at a rear sewer overflow relief gully (ORG) point. There were bamboo plants here before.  There is adequate drain flow at remaining downpipes. None of the evidence (including the Applicants’ evidence), suggests the damage occurred from water escaping “suddenly and without warning”. The FSP’s material offers an explanation for the distress near the breakage point of the pipe (due to action of tree roots), but has not identified what the cause of damage for the other areas is. The FSP says no insured event has been established for the other areas of damage. The Applicants’ material relies on the submission the same cause of damage applies to all areas. The Panel notes the only identified causes of damage are:  the action of tree roots or  water escaping over a period of time. Case No: 388986 Determination Page 4 of 8 Neither of t hese events is captured by the scope of the insured event of “escaping water”, which only covers “water escaping suddenly and without warning”. Neither of these events is covered elsewhere in the policy. Accordingly, on the balance of probabilities, the Panel is satisfied the Applicants have not established their loss occurred as a result of an insured event. On this basis, the FSP is entitled to deny the claim. FSP argues application of a Policy Exclusion The FSP has provided a report from a geotechnical consultant who says that the building distress has been caused by the shrinkage of the reactive clay soil due to the soil drying out and that the soil has dried out as a result of the action of the roots of trees and shrubs in the vicinity. The geotechnical consultant found that, despite the broken downpipe, the soil in the vicinity of the damage was actually drier than in other areas of the property. The Applicants have explained it may be drier because all pipes near the affected area have been closed off. It is understood the Applicants covered the area but no repairs have been effected. The Panel considers that, on the balance of probabilities, the cause of loss indicated by the geotechnical consultant is the most likely proximate cause. However, since the Applicants have failed to prove a loss under the policy it is unnecessary for the Panel to further consider the application of the policy exclusion. Applicants have not proven that damage resulted from earthquake The Applicants have also argued the pipe breakage (and thus the subsidence/sinking) was due to an earthquake. The policy provides an exception to its exclusion for subsidence, when the damage “was a direct result of and immediately following an earthquake or explosion”. In effect, this is the same as arguing that the proximate cause of damage is earthquake, which is an insured event under the policy. The FSP has provided data from Geoscience Australia to support its position that there seemed not to have been any seismic activity of importance in the period when the loss allegedly occurred. The Applicants say the date of the incident is unknown, so the date range provided by the FSP cannot be relied on. It is not up to the FSP to disprove the occurrence of an earthquake, but for the Applicants to establish it did occur. The Applicants have provided no supporting evidence to challenge the FSP’s information from Geoscience Australia, or to indicate the loss was likely to have occurred at a completely different date. Further, all evidence indicates damage was either due to tree roots or escape of water over a period of time, rather than being “the direct result of … an earthquake”. Case No: 388986 Determination Page 5 of 8 Therefore, the Panel is satisfied the Applicants have not established that the proximate cause of loss is earthquake. Section 46 of the Act does not provide relief to the Applicants Under section 46, if:  a claim is made regarding a loss that occurred in whole or in part as a result of a defect or imperfection  the insured was not aware of the defect or a reasonable person in the circumstances could not be expected to have been aware of the defect or imperfection the insurer may not rely on an exclusion clause that refers to the condition of the thing before the contract was entered into. In brief, the FSP has not relied on any such exclusion to deny the claim. Instead, the FSP is entitled to deny the claim because the Applicants have not established their loss is captured by the scope of cover of any insured event listed in the policy. Even if one referred to the exclusions the FSP mentioned, they are exclusions for subsidence, the action of tree roots and for damage caused by slow escape of water, none of which make reference to the condition (for example a defect) of a thing (in this case, the pipe). For these reasons, section 46 of the Act does not provide relief to the Applicants. Case No: 388986 Determination Page 6 of 8 3 Supporting information 3.1 FOS approach for this dispute This dispute has not been the subject of a FOS Recommendation. Due to its nature, FOS has considered it appropriate to proceed directly to Determination in line with the Operational Guidelines to the FOS Terms of Reference. This decision has been made by a Panel consisting of an Ombudsman and two Panel members with extensive experience in insurance industry matters and consumer claims. There has been a full exchange of the relevant material between the parties and each party has had the opportunity to address the issues raised. 3.2 Key points on relevant expert materials/statements Record Key points Applicants’ builder (C) Reports 21 Jul 2014  There are three separate causes of movement, with one common thread, water.  At the front northeast (sic) corner, the wall has sunk and moved noticeably, up to 50mm. The cause is obvious, the storm drain that runs down the corner has a split right on the be nd, at the bottom of the downpipe.  From inspections, this has been leaking for a substantial amount of time.  This has compromised the founding soils, to the point they are no longer loadbearing and the weight of the wall and footings have caused it to sink .  The Applicants could not have been reasonably aware water was escaping from the storm line and damaging foundations because it was buried out of sight.It constitutes an insurable event.  Across the back of the house, ground water has got in along the foot ing, causing it to rotate. This is causing minor cracking and movement.  This is due to water using the bottom of footings as conduit, running from the highest to the lowest point, with no way of escape.C needs to locate the main source of ground water.  As to the drive side wall, it is linked with the issue with the back of the house. C needs to investigate how much water there is and its direction. Applicants’ builder (C) Report 1 Sep 2014  The downpipe at corner of house has a sizeable crack, which would h ave been allowing large amount of water to escape under the footing, at every rain event.  There is now extra cracking, which C previously did not think was related to the leak. However, by the way footings are poured and formed, they act as a natural water course. The leaking downpipe could indeed be the cause of all movement in the house.  From the proximity of the crack and the amount of water leaking from it over a year, it would be enough to inundate the strip footing system.  When a strip footing system b ecomes inundated with water, it is possible for footings to rotate, causing cracks and movement in the brickwork. Extremities will fall away and crack, which is what is being experienced. Case No: 388986 Determination Page 7 of 8  Water inundating has caused this problem. The FSP’s assessor agrees the northeast corner had sunk due to water inundation. The rest of the house moved due to the same problem.  C’s engineers agree in principle the entire footing system has probably moved due to water inundation and the only positively established source is the leaking downpipe.  The cracked downpipe is the cause of this inundation. The cause of the crack to the pipe is still in question. It could have cracked due to an earth tremor. Without geotechnical data, this cannot be established.  Unless data is supplie d to categorically rule this out, there is a possibility this is how it was damaged.  As the FSP is unsure of what caused the damage, by virtue of section 46 of the Act, this is an insurable event. FSP’s building consultant (D) Report 3 Oct 2014  The buildi ng appears to have been built approximately 35 years ago, in an area of quaternary basalts.  Brickwork cracking and wall rotation has occurred around the north western corner of the building. Some lateral movement and cracking had occurred along the damp co urse layer, along the northern end of the rear or east wall.  The PVC stormwater pipe at the north western corner had a significant break on the top. It is unknown how long the pipe had been broken.  No actual water was encountered in the boreholes. Despite the break in the stormwater pipe, the clay from borehole 2 (near the most distressed area of the building) is significantly drier than in borehole 1.  The presence of numerous tree roots in the clay from borehole 2 confirms the localised soil drying in the area is the result of tree drying.  The external strip footings are satisfactorily founded on the natural clay soil. The clay has more than adequate bearing capacity to support the normally expected loads from this building.  Distress in low rise buildings i s usually related to foundation movement, which commonly occurs where the soil is predominantly clay, most of which is reactive.  The distress has resulted from shrinkage of the clay soil as a result of the drying action of trees.  Settlements have occurred beneath the north western section of the building due to the drying action of a neighbouring tree located over the side boundary on the neighbouring property to the north. It is likely the other trees in this area are contributing to the settlements.  The b roken stormwater pipe is likely to have had a secondary influence on the movement and distress. Water leaking from the pipe is likely to be entering the soil immediately beside the footings in this area.  Not only does such a problem lead to unacceptable fl uctuations in soil moisture content but dampness tends to attract a higher density of tree roots, which can then dry soil excessively in the seasonally drier months.  Further, the level of visible distress is likely to be linked to the relatively inflexible nature of the brick construction, in conjunction with the lack of adequate articulation.  D also observed some lateral movement between the base and the overlying brickwork along the northern end of the east wall. This is characteristic of a significant di fferential in the moisture level of the soil on the inside of the strip footings compared to the outside.  When a reactive soil on one side of a strip footing wets up relative to the reactive soil on the other side of the footing, it can lead to lateral Case No: 388986 Determination Page 8 of 8 mov ement as the wet soil expands and the dry soil shrinks.  There are various plumbing services adjacent to this wall of the building. The distress in this area is consistent with a possible leak or insufficiency in these plumbing services. FSP’s plumber (S) Report 12 Oct 2014  The stormwater drainage was positioned on the front west and east sides to combine and connect to a point of discharge at the rear east boundary.  A downpipe at the corner wall was found to connect to a 90mm stormwater drain, which had a hole in the top of the drain and a crack along the side wall.There were tree roots inside the drain, which appeared to originate from the rear east side.  A water test was placed at the drain opening and S identified minimal movement, confirming the drain w as mainly blocked and overflowed via the breakage points into the surrounding ground. This would occur continuously during rain periods.  The spouting joint above the northwest corner was water stained, indicating a weep at the joint. There was slight fasci a damage.  A water test was provided to the downpipes at front central west, south and eastern sides, which showed clear drain flow.  The subfloor drainage had presence of dampness at the north side brick wall / foundation area where the leaking stormwater d rain is located.  There were no problems with water supply pipes or suspended sewer drainage pipes that appeared to be leaking.  A water supply test was carried out, which showed a leak was present at the cistern in the main bathroom.  Damage was present at t he rear sewer overflow relief gully (ORG) point on the rear of the home. The Applicants stated there were bamboo plants at this location, which have been removed.  There is adequate drain flow at the remaining downpipes. 3.3 Other relevant material relied upon  Product disclosure statement with issue date 1 May 2013.  Policy schedule for the period 29 January 2014 to 28 January 2015.  FSP’s claim notes.  FSP’s home assessment report with assessment date 24 July 2014.  Data from Geoscience Australia for dates between 13 January 2014 and 11 July 2014.  C’s quotation dated 2 March 2015.  Various images of the broken pipe and claimed damage.  Parties’ submissions.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.