Home / Financial Firm (Unknown - Insurer) / Determination 384920

Determination 384920

Denial of claim

FirmFinancial Firm (Unknown - Insurer)
Decided2015-06-17
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded$6,000
Non-financial loss$1,500
Amount claimed$20,345
SourceAFCA PDF

Summary

The Applicants' off-grid solar power system failed and the FSP denied the claim. AFCA held that the generator's own breakdown was excluded, but resultant damage to the other components was covered, and ordered $6,000 consequential loss, $1,500 non-financial loss and interest.

The mechanical or electrical breakdown exclusion does not apply to resultant damage to a building, and the battery and inverter damage resulted from the generator breakdown.

Issues

Subjects and remedies

financial hardshiphome or building damagepay claimpay compensationpay interestpay non financial loss

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of Claim Determination Case No: 384920 Determination Page 1 of 9 Case number : 384920 20 May 2015 1 Overview 1.1 Dispute The Applicants‟ hold a Home Buildings insurance policy with the Financial Services Provider (FSP). The Applicants lodged a claim on 15 August 2014 after their standalone solar power system failed. The FSP has denied the claim. 1.2 Issues and key findings Is the FSP entitled to deny the Applicants ’ claim? The FSP is not entitled to deny the claim because:  the available information establishes that the proximate cause of the damage to the Applicants‟ solar power system was electrical failure of the generator whilst connected to the battery charging unit  whilst the policy excludes cover for damages arising from electrical failure breakdown or failure, it does cover resultant damage to buildings caused by such a breakdown  the damage to the battery charging unit, batteries and inverter in the solar power system have resulted from the electrical failure of the generator  the Applicants are therefore entitled to indemnity for the resultant damage caused by the failure of the generator. Are the Applicants entitled to recover their consequential losses? The Applicants are entitled to recover their consequential financial losses as follows:  Generator hire claim $3,000  Fuel/running cost claim $3,000 Are the Applicants entitled to compensation? It is fair in all the circumstances that the FSP pay the Applicants $1,500 for compensation for non-financial loss. Case No: 384920 Determination Page 2 of 9 1.3 Determination This Determination is substantially in favour of the Applicants. The FSP is not required to indemnify the Applicants for replacement and installation of the damaged generator. The FSP is however required to indemnify the Applicants for the replacement installation and testing of the remaining damaged components of their solar power system. The FSP is to pay the Applicants $6,000 towards their claims for consequential financial losses relating to generator hire and fuel costs. The FSP must pay interest to the Applicants on the above sum, in accordance with section 57 of the Insurance Contracts Act 1984 (Cth) (the Act). Interest should be paid from the date the FSP denied the Applicants ‟ claim (14 October 2014) up until payment is made to the Applicants, in accordance with this Determination. The FSP is to also pay the Applicants $1,500 by way of compensation for non- financial loss pursuant to the FOS Terms of Reference. Case No: 384920 Determination Page 3 of 9 2 Reasons for Determination 2.1 Is the FSP entitled to deny the Applicants’ claim? Policy provides cover for damage to the home caused by listed events The Applicants ‟ policy provides cover for damage to home caused by a number of insured events including burning out (fusion) or an electric motor; and power surge. The Applicants‟ solar power system does not include an electric motor so the claim cannot be considered to have arisen from fusion. The FSP says that the damage was caused by a „power spike‟ and whilst the policy provides coverage for damage caused by a power surge, the surge is to have come from an externally identifiable source and any surges caused at the site (ie by the Applicants‟ own generator) are excluded. Therefore the claim does not fall within the cover provided under power surge. Accordingly, the available evidence indicates that the damage to the Applicants‟ solar power system was not caused by either of these, or any other listed event. The policy also provides cover for resultant damage Notwithstanding the damage to the solar power system does not fall within the scope of a specific listed event, under the general exclusions the policy provides: “We will not pay for any loss or damage or liability caused directly by or resulting from: … Mechanical or electrical breakdown other than an electric motor burning out, unless the breakdown results in damage to your building or conte nts.” (my emphasis) There is no dispute by the parties that the Applicants‟ solar system constitutes „building‟ as defined by the policy. The FSP‟s expert evidence indicates the damage was caused by electrical br eakdown of the Applicants‟ generator. Speci fically, the FSP‟s assessor (CC), after considering the electrical engineering report of CE, reported: “We note that there has been mechanical and electrical breakdown of the generator and we note that this has not been as a result of burn out.” The FSP says that the solar system‟s battery, inverter and battery charger are all components that make up the solar system and that the system is a distinct item insured under the policy. Therefore, the damage to the remainder of the components cannot be considered resultant damage to the building or contents. I do not accept this proposition. The FSP‟s own electrical expert CE in his report refers to the damage to the battery and to the inverter module as „resulting‟ from the failure of the battery charger whilst on 240V generator charge. It is also clear from his report that assessment of the damage required individual inspection and Case No: 384920 Determination Page 4 of 9 testing of the items. Further, the scope of work provided by CE goes on to outline the requirement of individually sourcing and installing each of these components. On this basis, it would appear artificial to characterise each of these items as being sufficiently indistinct to simply compromise the „solar system‟. In my mind attempting to apply such a blanket exclusion is akin to categorising the individual components of a swimming pool system (ie the pool shell, filter, plumbing and pump) as being one item. Whilst it is necessary to all of these components to operate together for effective functioning of a swimming pool, they each have a specific function, specific from one another and the failure of one does not necessarily cause the failure of another. Therefore, having considered the exclusion above, I am satisfied that the electrical breakdown of the generator itself is an excluded event under the policy, however the resultant damage to the remainder of the components identified by CE is not. The FSP is therefore required to indemnify the Applicants‟ for the damage to items resulting from the electrical breakdown of the generator. The Applicants have suffered both direct financial and non-financial losses The Terms of Reference allow FOS to decide that the FSP must compensate an Applicant for direct financial loss or damage arising from a claim. As the Applicants‟ solar power system is a standalone system and there is no other electricity supply to their property, it was necessary for them to hire a petrol generator to meet their minimum electricity requirements such as their refrigerator, washing machine and lighting. The Applicants say that generator hire and the cost of fuel to run the generator (at approximately $30 per day) has resulted in significant financial hardship to them and is necessary to continue to run their household which includes four small children. The Applicants are required to provide supporting documents in respect of these costs. The Applicants have provided evidence that the loss of their solar power system has caused them financial hardship including legal proceedings issued against them by their local council in November 2011 in respect of failure to pay their rates. Due to the FSP‟s wrongful denial of their claim, it has been necessary for them to continue to operate the hired generator for several months whilst awaiting the outcome of the FSP ‟s IDR process, and which has continued whilst awaiting determination of the matter by FOS. The Applicants are required to provide proof of the hire payments. The Terms of Reference provide that a $3,000 cap applies for each claim for consequential loss. To that end, I consider the claim for generator hire, and fuel to be separate claims. The Applicants are entitled to recover the full extent of the cap on each of these claims, making a total cap of $6,000, subject to providing proof as noted above. Case No: 384920 Determination Page 5 of 9 The Terms of Reference also allow for an award of compensation up to $3,000 but only where there is an unusual degree or extent of physical inconvenience, time taken to resolve the situation or interference with the Applicants ‟ expectation of enjoyment or peace of mind. The Applicants have a young family, including four children. They have reported that the hired generator only meets their minimum electricity requirements and has caused significant stress and inconvenience to the everyday functioning of their household. The FSP says it offered the Applicants alternative accommodation whilst the claim was investigated however this was declined. The Applicants say relocating to alternative accommodation was not practical in the circumstances as their home is on a rural property with livestock which need attending to and the closest alternative accommodation would have been 20-30kms away. I accept these circumstances would have been very inconvenient and would have interfered with the Applicants ‟ peace of mind. I consider it is fair in all the circumstances that the FSP pay the Applicants $1,500 compensation for non- financial loss pursuant to the Terms of Reference. Case No: 384920 Determination Page 6 of 9 3 Supporting information There has been an exchange of the relevant material on which the parties rely, and each party has had the opportunity to respond to the issues raised. Whilst I have reviewed all of the information, I have only referred to the information that is relevant to this Recommendation for the sake of brevity. 3.1 Relevant policy provisions “ Buildings cover What buildings we protect We will cover residential buildings located at the insured property address listed on your Schedule, their fixtures and fittings and any structural improvements at your home. … Building cover includes … The specific events that your buildings are covered for are listed in the table below. This cover is subject to the exclusions listed on pages 43-44. … Event Power Surge We will Cover Power surge to domestic equipment directly by an identifiable and verifiable source outside your home including a light ning strike, an object contacting power lines, the resumption of power following a blackout caused by a storm or unexpected interference wit h a power company trans former by an animal. We will not cover Any power surges caused at the site.” “ Exclusions Any cover we provide is subject to the following exclusions: … Buildings and contents cover exclusions We will not pay for any loss or damage which is caused directly or indirectly by: ... o Mechanic al or electrical breakdown ot her than an electrical motor burning out, unless the breakdown results in damage to your buildings or cont ents.” 3.2 Chronology Date Event 15 August 2014  Applicants‟ claim lodged with FSP . 22 August 2014  Applicants submitted report and quotation for damage .  FSP‟s Assessor [CC] appointed . 26 August 2014  CC conducted inspection of Applicants‟ damaged solar power system.  CC appointed electrician [CE ] to inspect damage . 27 August 2014  CE inspected Applicants‟ damaged solar power system . 29 August 2014  CC responded to email from Applicants advising timeframe Case No: 384920 Determination Page 7 of 9 for receiving report from electrician usually 7 - 10 days however matter has been given priority . 4 September 2014  CC received report from CE .  CC contacted Applicants by phone and advised damage to solar power system not caused by insured event and therefore not covered. 8 September 2014  Decline letter sent to Applicants by FSP. 23 September 201 4  Applicants‟ claim escalated to FSP‟s Internal Dispute Resolution (IDR) process. 13 October 2014  Applicants emailed FSP to follow up outcome of IDR review . 14 October 2014  FSP issue d Final Decision Letter (FDL) . 3.3 Expert evidence Record Key points Applicant’s expert (RM) Report 22 August 2014 “The stand alone system not working. I asked [Applicants] start - up procedure, we ran through what [they] did and it was the correct way to do it. [Male Applicant] said he charges the battery bank regularly as t his extends the battery life considerably. When I tried to run the generator, it just stalls. When this happens it is usually a short on the primary winding of the battery charger. Since this has happened it is evident that the battery bank voltage has red uc ed and has damaged cells. When there is not the sufficient voltage the inverter will not work, which is what powers the house. I have attached a quote for the scope of work required to get it back operational.” Applicants’ expert (RM) Quotation 22 Aug ust 2014 “Replacement of: Solid State Battery Charger … 24 x 2V Batteries 1200Ah Installation, Test and Commission $20,345.45 GST” FSP’s Electrician (CE ) Report 4 September 2014 “NOTES An inspection of the above property, which is approximately 10 years old, was carried out on 27/08/2014 to investigate damage to this property, which is constructed of metal deck, roof, steel framed and cladded walls and is maintained in fair condition. R ESULTING DAMAGE Damage has occurred where the “stand alone” solar power system has ceased working. CAUSE OF DAMAGE As authorised, we have arranged for attendance of a qualified contractor to inspect and report on the condition of the solar power system. Our contractor has advised that: Site inspection revealed the following: System was in off state on arrival. Battery voltage 55.5V on PV charging. Case No: 384920 Determination Page 8 of 9 3 cells completed discharged, possible resulting damage over battery charger failure. Battery charger inter nal failure. Over charging the battery set. Inverter failed load test. Spoke with manufacturer while onsite, and they ran through some tests with me to ascertain this. (Would need replacement). It looks like the PL60 solar charger is still operational. L oad test of complet e system failed to out put 500w, system shut down, battery voltage dropped below 42V on 500w load test. (Complet e system failure). When testing the system it is my opinion that the battery charger has failed whilst on 240V generator char ge, resulting in damage to the battery set and the inverter module. MAINTENANCE ISSUES Our qualified attending cont ractor has advised that the restore the system to an operation state, will require the following items: New battery set – 24V or 48V set. New inverter module New battery charger. … CONCLUSION We believe the resulting damage is due to the battery charger which has failed whilst on 240V generator charge, resulting in damage to the battery set and the inverter module. … Original Scope Of Work: … 1 - 1 - 1 Disconnect, strip and remove damaged batteries, inverter charging unit, … $576.00 1 - 1 - 2 Source, supply and install new Inverter/charging unit, $6,436.62 1 - 1 - 3 Supply and Installation of 24V Battery of Hoppecke 2V 1700AH OPVZ cells, including new cabling via existing isolator plus interlinking battery cablin g $132.00”. FSP’s Assessor (CC) Second Report 4 September 2014 “We have held numerous discussions with [CS] in relation to this matter as this information seemed somewhat contradictory to the information supplied by [RM] in their report. You will note from [RM]‟s report that there was damage to the winding on the battery charger. We confirm that the battery charger is a solid state device and the windings do not form part of an electric motor, as such there is no possibility that this item can fuse nor is there an electric motor to burn out. We refer this matter to your office for consideration as we are unable to determine attachment of liability. We note that the Insured‟s policy does respond to burning out (fusion) of an electric motor , however as per the above, we confirm there is no electric motor that has burnt out or fused. More so, we not e that the Insured‟s policy does respond to power surge … caused by an identifiable and verifiable source outside your home, however as per the r eports prepared by [CS] and [RM] (and verified by the Insured), the power being fed into the battery charger was coming from a Case No: 384920 Determination Page 9 of 9 diesel generator located within the battery shed. We do not believe that either of these insur able events have been triggered. For your consideration, we not e that the policy specifically excludes mechanical or electrical breakdown other than an electric motor burning out, unless the breakdown results in damage to your building or contents. We note that there has been mechanical and electrical breakdown of the generator and we note that this has not been as a result of burn out. The Insured‟s solar power system is a 3 part unit in so much as there are batteries, there is an inverter/charger unit and there is a generator. Whilst a ll units operate in conjunction with each other, they are all separately iden ti fiable and it could be conceivably determined that damages to the inverter and batteries could have occurred as a result of the breakdown of the charger. We refer this matter t o your office for consideration. ” 3.4 Relevant terms of the FOS Terms of Reference 9.2 Compensation for direct financial loss or damage Subject to paragraph 9.7, FOS may decide that the Financial Services Provider compensate the Applicant for direct financial loss or damage. 9.3 Other compensation a) Subject to paragraph 9.3c) and paragraph 9.7, FOS may decide that the Financial Services Provider compensate the Applicant for consequential financial loss or damage. An y amount awarded must not exceed the amount specified in Schedule 3. b) Subject to paragraph 9.3 c) and paragraph 9.7, FOS may decide that the Financial Services Provider compensate the Applicant for non-financial loss but only where: (i) an unusual degree or extent of ph ysical inconvenience, time take to resolve the situation or interference with the Applicant‟s expectation of enjoyment or peace of mind has occurred… … The maximum amount of compensation for non-financial loss will be $3,000 per claim made in the Dispute.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.