Determination 384920
Denial of claim
Summary
The Applicants' off-grid solar power system failed and the FSP denied the claim. AFCA held that the generator's own breakdown was excluded, but resultant damage to the other components was covered, and ordered $6,000 consequential loss, $1,500 non-financial loss and interest.
The mechanical or electrical breakdown exclusion does not apply to resultant damage to a building, and the battery and inverter damage resulted from the generator breakdown.
Issues
- Claim denial primary · upheld“The FSP is not entitled to deny the claim: the generator breakdown is excluded, but resultant damage to the battery, inverter and charger is covered.”
- Claim amount dispute secondary · upheld“The FSP is to pay the Applicants $6,000 towards their claims for consequential financial losses relating to generator hire and fuel costs.”
Subjects and remedies
financial hardshiphome or building damagepay claimpay compensationpay interestpay non financial loss
Related
All Financial Firm (Unknown - Insurer) determinations · Find similar determinations
Text of the determination
Determination
General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of
Claim
Determination
Case No: 384920 Determination Page 1 of 9
Case number : 384920 20 May 2015
1 Overview
1.1 Dispute
The Applicants‟ hold a Home Buildings insurance policy with the Financial
Services Provider (FSP). The Applicants lodged a claim on 15 August 2014 after
their standalone solar power system failed.
The FSP has denied the claim.
1.2 Issues and key findings
Is the FSP entitled to deny the Applicants ’ claim?
The FSP is not entitled to deny the claim because:
the available information establishes that the proximate cause of the damage
to the Applicants‟ solar power system was electrical failure of the generator
whilst connected to the battery charging unit
whilst the policy excludes cover for damages arising from electrical failure
breakdown or failure, it does cover resultant damage to buildings caused by
such a breakdown
the damage to the battery charging unit, batteries and inverter in the solar
power system have resulted from the electrical failure of the generator
the Applicants are therefore entitled to indemnity for the resultant damage
caused by the failure of the generator.
Are the Applicants entitled to recover their consequential losses?
The Applicants are entitled to recover their consequential financial losses as
follows:
Generator hire claim $3,000
Fuel/running cost claim $3,000
Are the Applicants entitled to compensation?
It is fair in all the circumstances that the FSP pay the Applicants $1,500 for
compensation for non-financial loss.
Case No: 384920 Determination Page 2 of 9
1.3 Determination
This Determination is substantially in favour of the Applicants.
The FSP is not required to indemnify the Applicants for replacement and
installation of the damaged generator. The FSP is however required to indemnify
the Applicants for the replacement installation and testing of the remaining
damaged components of their solar power system.
The FSP is to pay the Applicants $6,000 towards their claims for consequential
financial losses relating to generator hire and fuel costs. The FSP must pay
interest to the Applicants on the above sum, in accordance with section 57 of the
Insurance Contracts Act 1984 (Cth) (the Act). Interest should be paid from the
date the FSP denied the Applicants ‟ claim (14 October 2014) up until payment is
made to the Applicants, in accordance with this Determination.
The FSP is to also pay the Applicants $1,500 by way of compensation for non-
financial loss pursuant to the FOS Terms of Reference.
Case No: 384920 Determination Page 3 of 9
2 Reasons for Determination
2.1 Is the FSP entitled to deny the Applicants’ claim?
Policy provides cover for damage to the home caused by listed events
The Applicants ‟ policy provides cover for damage to home caused by a number of
insured events including burning out (fusion) or an electric motor; and power
surge.
The Applicants‟ solar power system does not include an electric motor so the
claim cannot be considered to have arisen from fusion.
The FSP says that the damage was caused by a „power spike‟ and whilst the
policy provides coverage for damage caused by a power surge, the surge is to
have come from an externally identifiable source and any surges caused at the
site (ie by the Applicants‟ own generator) are excluded. Therefore the claim does
not fall within the cover provided under power surge.
Accordingly, the available evidence indicates that the damage to the Applicants‟
solar power system was not caused by either of these, or any other listed event.
The policy also provides cover for resultant damage
Notwithstanding the damage to the solar power system does not fall within the
scope of a specific listed event, under the general exclusions the policy provides:
“We will not pay for any loss or damage or liability caused directly by or
resulting from:
…
Mechanical or electrical breakdown other than an electric motor burning
out, unless the breakdown results in damage to your building or
conte nts.” (my emphasis)
There is no dispute by the parties that the Applicants‟ solar system constitutes
„building‟ as defined by the policy. The FSP‟s expert evidence indicates the
damage was caused by electrical br eakdown of the Applicants‟ generator.
Speci fically, the FSP‟s assessor (CC), after considering the electrical engineering
report of CE, reported:
“We note that there has been mechanical and electrical breakdown of the
generator and we note that this has not been as a result of burn out.”
The FSP says that the solar system‟s battery, inverter and battery charger are all
components that make up the solar system and that the system is a distinct item
insured under the policy. Therefore, the damage to the remainder of the
components cannot be considered resultant damage to the building or contents.
I do not accept this proposition. The FSP‟s own electrical expert CE in his report
refers to the damage to the battery and to the inverter module as „resulting‟ from
the failure of the battery charger whilst on 240V generator charge. It is also clear
from his report that assessment of the damage required individual inspection and
Case No: 384920 Determination Page 4 of 9
testing of the items. Further, the scope of work provided by CE goes on to outline
the requirement of individually sourcing and installing each of these components.
On this basis, it would appear artificial to characterise each of these items as
being sufficiently indistinct to simply compromise the „solar system‟. In my mind
attempting to apply such a blanket exclusion is akin to categorising the individual
components of a swimming pool system (ie the pool shell, filter, plumbing and
pump) as being one item. Whilst it is necessary to all of these components to
operate together for effective functioning of a swimming pool, they each have a
specific function, specific from one another and the failure of one does not
necessarily cause the failure of another.
Therefore, having considered the exclusion above, I am satisfied that the
electrical breakdown of the generator itself is an excluded event under the policy,
however the resultant damage to the remainder of the components identified by
CE is not.
The FSP is therefore required to indemnify the Applicants‟ for the damage to
items resulting from the electrical breakdown of the generator.
The Applicants have suffered both direct financial and non-financial losses
The Terms of Reference allow FOS to decide that the FSP must compensate an
Applicant for direct financial loss or damage arising from a claim.
As the Applicants‟ solar power system is a standalone system and there is no
other electricity supply to their property, it was necessary for them to hire a petrol
generator to meet their minimum electricity requirements such as their
refrigerator, washing machine and lighting.
The Applicants say that generator hire and the cost of fuel to run the generator (at
approximately $30 per day) has resulted in significant financial hardship to them
and is necessary to continue to run their household which includes four small
children. The Applicants are required to provide supporting documents in respect
of these costs.
The Applicants have provided evidence that the loss of their solar power system
has caused them financial hardship including legal proceedings issued against
them by their local council in November 2011 in respect of failure to pay their
rates.
Due to the FSP‟s wrongful denial of their claim, it has been necessary for them to
continue to operate the hired generator for several months whilst awaiting the
outcome of the FSP ‟s IDR process, and which has continued whilst awaiting
determination of the matter by FOS. The Applicants are required to provide proof
of the hire payments.
The Terms of Reference provide that a $3,000 cap applies for each claim for
consequential loss. To that end, I consider the claim for generator hire, and fuel to
be separate claims. The Applicants are entitled to recover the full extent of the
cap on each of these claims, making a total cap of $6,000, subject to providing
proof as noted above.
Case No: 384920 Determination Page 5 of 9
The Terms of Reference also allow for an award of compensation up to $3,000
but only where there is an unusual degree or extent of physical inconvenience,
time taken to resolve the situation or interference with the Applicants ‟ expectation
of enjoyment or peace of mind.
The Applicants have a young family, including four children. They have reported
that the hired generator only meets their minimum electricity requirements and
has caused significant stress and inconvenience to the everyday functioning of
their household.
The FSP says it offered the Applicants alternative accommodation whilst the claim
was investigated however this was declined. The Applicants say relocating to
alternative accommodation was not practical in the circumstances as their home
is on a rural property with livestock which need attending to and the closest
alternative accommodation would have been 20-30kms away.
I accept these circumstances would have been very inconvenient and would have
interfered with the Applicants ‟ peace of mind. I consider it is fair in all the
circumstances that the FSP pay the Applicants $1,500 compensation for non-
financial loss pursuant to the Terms of Reference.
Case No: 384920 Determination Page 6 of 9
3 Supporting information
There has been an exchange of the relevant material on which the parties rely,
and each party has had the opportunity to respond to the issues raised.
Whilst I have reviewed all of the information, I have only referred to the
information that is relevant to this Recommendation for the sake of brevity.
3.1 Relevant policy provisions
“ Buildings cover
What buildings we protect
We will cover residential buildings located at the insured property address listed on your
Schedule, their fixtures and fittings and any structural improvements at your home.
…
Building cover includes
…
The specific events that your buildings are covered for are listed in the table below.
This cover is subject to the exclusions listed on pages 43-44.
…
Event
Power Surge
We will Cover
Power surge to domestic equipment directly by an identifiable and verifiable
source outside your home including a light ning strike, an object contacting power
lines, the resumption of power following a blackout caused by a storm or
unexpected interference wit h a power company trans former by an animal.
We will not cover
Any power surges caused at the site.”
“ Exclusions
Any cover we provide is subject to the following exclusions:
…
Buildings and contents cover exclusions
We will not pay for any loss or damage which is caused directly or indirectly by:
...
o Mechanic al or electrical breakdown ot her than an electrical motor burning out,
unless the breakdown results in damage to your buildings or cont ents.”
3.2 Chronology
Date Event
15 August 2014 Applicants‟ claim lodged with FSP .
22 August 2014 Applicants submitted report and quotation for damage .
FSP‟s Assessor [CC] appointed .
26 August 2014 CC conducted inspection of Applicants‟ damaged solar
power system.
CC appointed electrician [CE ] to inspect damage .
27 August 2014 CE inspected Applicants‟ damaged solar power system .
29 August 2014 CC responded to email from Applicants advising timeframe
Case No: 384920 Determination Page 7 of 9
for receiving report from electrician usually 7 - 10 days
however matter has been given priority .
4 September 2014 CC received report from CE .
CC contacted Applicants by phone and advised damage to
solar power system not caused by insured event and
therefore not covered.
8 September 2014 Decline letter sent to Applicants by FSP.
23 September 201 4 Applicants‟ claim escalated to FSP‟s Internal Dispute
Resolution (IDR) process.
13 October 2014 Applicants emailed FSP to follow up outcome of IDR
review .
14 October 2014 FSP issue d Final Decision Letter (FDL) .
3.3 Expert evidence
Record Key points
Applicant’s expert (RM)
Report
22 August 2014
“The stand alone system not working. I asked [Applicants] start - up
procedure, we ran through what [they] did and it was the correct
way to do it. [Male Applicant] said he charges the battery bank
regularly as t his extends the battery life considerably. When I tried
to run the generator, it just stalls. When this happens it is usually a
short on the primary winding of the battery charger. Since this has
happened it is evident that the battery bank voltage has red uc ed
and has damaged cells. When there is not the sufficient voltage
the inverter will not work, which is what powers the house.
I have attached a quote for the scope of work required to get it
back operational.”
Applicants’ expert (RM)
Quotation
22 Aug ust 2014
“Replacement of:
Solid State Battery Charger …
24 x 2V Batteries 1200Ah
Installation, Test and Commission
$20,345.45 GST”
FSP’s Electrician (CE )
Report
4 September 2014
“NOTES
An inspection of the above property, which is approximately 10
years old, was carried out on 27/08/2014 to investigate damage to
this property, which is constructed of metal deck, roof, steel
framed and cladded walls and is maintained in fair condition.
R ESULTING DAMAGE
Damage has occurred where the “stand alone” solar power
system has ceased working.
CAUSE OF DAMAGE
As authorised, we have arranged for attendance of a qualified
contractor to inspect and report on the condition of the solar power
system. Our contractor has advised that:
Site inspection revealed the following:
System was in off state on arrival.
Battery voltage 55.5V on PV charging.
Case No: 384920 Determination Page 8 of 9
3 cells completed discharged, possible resulting damage over
battery charger failure.
Battery charger inter nal failure. Over charging the battery set.
Inverter failed load test. Spoke with manufacturer while onsite,
and they ran through some tests with me to ascertain this. (Would
need replacement).
It looks like the PL60 solar charger is still operational.
L oad test of complet e system failed to out put 500w, system shut
down, battery voltage dropped below 42V on 500w load test.
(Complet e system failure).
When testing the system it is my opinion that the battery charger
has failed whilst on 240V generator char ge, resulting in damage to
the battery set and the inverter module.
MAINTENANCE ISSUES
Our qualified attending cont ractor has advised that the restore the
system to an operation state, will require the following items:
New battery set – 24V or 48V set.
New inverter module
New battery charger.
…
CONCLUSION
We believe the resulting damage is due to the battery charger
which has failed whilst on 240V generator charge, resulting in
damage to the battery set and the inverter module.
…
Original Scope Of Work:
…
1 - 1 - 1 Disconnect, strip and remove damaged batteries, inverter
charging unit, … $576.00
1 - 1 - 2 Source, supply and install new Inverter/charging unit,
$6,436.62
1 - 1 - 3 Supply and Installation of 24V Battery of Hoppecke 2V
1700AH OPVZ cells, including new cabling via existing isolator
plus interlinking battery cablin g $132.00”.
FSP’s Assessor (CC)
Second Report
4 September 2014
“We have held numerous discussions with [CS] in relation to
this matter as this information seemed somewhat
contradictory to the information supplied by [RM] in their
report.
You will note from [RM]‟s report that there was damage to the
winding on the battery charger. We confirm that the battery
charger is a solid state device and the windings do not form
part of an electric motor, as such there is no possibility that
this item can fuse nor is there an electric motor to burn out.
We refer this matter to your office for consideration as we are
unable to determine attachment of liability.
We note that the Insured‟s policy does respond to burning out
(fusion) of an electric motor , however as per the above, we
confirm there is no electric motor that has burnt out or fused.
More so, we not e that the Insured‟s policy does respond to
power surge … caused by an identifiable and verifiable
source outside your home, however as per the r eports
prepared by [CS] and [RM] (and verified by the Insured), the
power being fed into the battery charger was coming from a
Case No: 384920 Determination Page 9 of 9
diesel generator located within the battery shed.
We do not believe that either of these insur able events have
been triggered.
For your consideration, we not e that the policy specifically
excludes mechanical or electrical breakdown other than an
electric motor burning out, unless the breakdown results
in damage to your building or contents.
We note that there has been mechanical and electrical
breakdown of the generator and we note that this has not
been as a result of burn out.
The Insured‟s solar power system is a 3 part unit in so much
as there are batteries, there is an inverter/charger unit and
there is a generator. Whilst a ll units operate in conjunction
with each other, they are all separately iden ti fiable and it
could be conceivably determined that damages to the inverter
and batteries could have occurred as a result of the
breakdown of the charger.
We refer this matter t o your office for consideration. ”
3.4 Relevant terms of the FOS Terms of Reference
9.2 Compensation for direct financial loss or damage
Subject to paragraph 9.7, FOS may decide that the Financial Services Provider
compensate the Applicant for direct financial loss or damage.
9.3 Other compensation
a) Subject to paragraph 9.3c) and paragraph 9.7, FOS may decide that the Financial
Services Provider compensate the Applicant for consequential financial loss or damage.
An y amount awarded must not exceed the amount specified in Schedule 3.
b) Subject to paragraph 9.3 c) and paragraph 9.7, FOS may decide that the Financial
Services Provider compensate the Applicant for non-financial loss but only where:
(i) an unusual degree or extent of ph ysical inconvenience, time take to resolve
the situation or interference with the Applicant‟s expectation of enjoyment or
peace of mind has occurred…
…
The maximum amount of compensation for non-financial loss will be $3,000 per claim
made in the Dispute.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.