Home / Financial Firm (Unknown - Insurer) / Determination 384841

Determination 384841

Claim for storm-damaged building windows denied under exclusions

FirmFinancial Firm (Unknown - Insurer)
Decided2015-06-19
ProductGeneral Insurance · Strata
OutcomeFor the complainant
Amount awarded—
Non-financial loss—
Amount claimed$44,510
SourceAFCA PDF

Summary

The owners corporation claimed for storm-damaged building windows that the FSP denied under policy exclusions. AFCA found the damage accidental and caused by a design flaw, not an excluded cause, and ordered the claim accepted with interest.

The insurer bears the onus of proving an exclusion applies, and it could not show that gradual deterioration, known defects or defective workmanship caused the loss.

Issues

Subjects and remedies

home or building damagenatural disasterpay claimpay interest

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Residential Strata Title - FSP Decision - Denial of claim-Exclusion/ condition Determination Case No: 384841 Determination Page 1 of 8 Case number : 384841 18 June 2015 1 Overview 1.1 Dispute The Applicant, who represents the owners ‟ corporation for a strata titled commercial building, lodged a claim for damage after glass panes fell from the building in high winds on 5 August 2013. The Financial Services Provider (FSP) denied the claim on the basis that the cause of the damage is excluded from cover under the policy. 1.2 Issues and key findings Is the FSP entitled to deny the claim? The FSP is not entitled to deny the claim because:  The Applicant has established the claim falls within the policy.  The cause of the damage was the defective design of the fixing of the fins which strengthen the frameless window panels.  The FSP has failed to prove that the cause of the damage is excluded under the policy. 1.3 Determination This Determination is in favour of the Applicant. The FSP must:  accept the claim in accordance with the terms and conditions of the policy  pay interest in accordance with the Insurance Contracts Act on the amount paid to the Applicant, calculated from 15 August 2014 until the date of payment. Case No: 384841 Determination Page 2 of 8 2 Reasons for Determination 2.1 The FOS Approach I have determined this dispute considering what is fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all the material submitted by the parties. I am satisfied that the documentation I have relied on has been provided to both parties and each party has had the opportunity of addressing any issues raised. This dispute has been expedited to a Determination. No Recommendation was issued. 2.2 Is the FSP entitled to deny the claim? The policy provides cover for accidental loss or damage The policy provides cover for accidental loss or damage to the building that occurs during the period of insurance. Although the term accidental damage is not defined in the policy, the courts have defined “accidental” in an insurance context as something that is “unintended and unexpected. ” On 5 August 2013, the area around the insured building experienced high winds and the third floor windows of the building blew out. The Council issued an emergency work order and the Applicant carried out those works to the sum on $44,510. I accept that the damage to the windows was accidental. As the Applicant has established the claim falls within the policy, the burden shifts to the FSP to establish it can deny the claim. Cause of the damage was defective design of the fixing of the window fins The report by the local council‟s structural engineer (H) was intended to determine the actions for make-safe of the building. H noted that the glass window panels were supported by glass fins, which are then fixed into steel brackets into the building frame top and bottom. However, other than noting that several panes of glass had fallen during strong winds, H‟s report contained little information which can be relied upon with respect to establishing the cause of the damage. The Applicant‟s building consu ltant (F) inspected the building in 2014 after the repair/replacement of the window panes and strengthening fins had occurred. F reported that the window breakage was believed to be as a result of poor standard of fixing which may have been acceptable at the time (the windows were installed) but would not be approved today. F stated that: Case No: 384841 Determination Page 3 of 8  the glass strengthening fins appear to be poorly founded and connected to the concrete support wall  it is likely that the fins have been installed into the rebates with a grout filler  a grout filler is b rittle and would not provide the resistance required under adverse wind conditions. The FSP‟s assessor (P) reviewed the report by F, and stated in its report of 9 May 2014 that the retrospective report by F does not unequivocally verify the circumstances surrounding the claim. However with respect to the cause of the damage, P appears to agree with F, saying that the principle factor is inadequate/defective fixing of the window fins. Further, P and F also appear to agree that the new fixings to the fins are better suited to the function of holding the fins in place:  F reported that the “additional stainless steel angle fixtures together with silicon filling that has been applied to the new installation and applied to all other window fins is a vastly better fixing to withstand the wind loads ”  P, in its 9 May 2014 report, notes that the redesign by structural engineers testifies to the defective nature of the windows. On balance, I conclude that the cause of the damage was the defective fixing of the window fins. This is a design flaw. The FSP referred to three exclusions The FSP has sought to rely on several exclusions:  damage caused by lack of maintenance, rust, oxidation, corrosion, Wear, Tear, fading, gradual corrosion or gradual deterioration, concrete or brick cancer, developing flaws, wet or dry rot, or failure to maintain the building property in a reasonably good state o f repair  damage caused by non-rectification of a building defect, error or omission the Applicant was aware of, or should reasonable have been aware of.  the cost of rectifying faulty or defective materials or faulty or defective workmanship. Gradual deterioration and poor maintenance exclusion does not apply With respect to the first of the above exclusions relating to gradual deterioration and poor maintenance:  The 22 August 2013 report by P indicates that the general maintenance of the property was poor or neglected, and points to unmonitored roof drainage, general debris, aged graffiti and avian occupation of the roof. However the report does not provide any evidence to show that any such lack of maintenance caused or contributed to the damage.  The 22 August 2013 report by P also notes “crude, reactive attempts at remedying the deteriorated natur e of the glazing fixings within the frames”. However, the report does not provide any evidence proving the glazing fixings were deteriorated, or how any such deterioration caused or contributed to the damage. Case No: 384841 Determination Page 4 of 8 Accordingly, I do not accept that the FSP proven that this exclusion applies. Failure to rectify a building defect exclusion does not apply With respect to the second of the above exclusions relating to the failure to rectify building defects known to the Applicant:  The 22 August 2013 report by P noted the reference by structural engineer H to previous problems which have resulted in the replacement of glass panels.  P stated in its 9 May 2014 report that the “comprehensive evidence of previous problems with the glazing and pre -existing knowledge of same is unequivocal” . However:  the report by F states that there was likely to have been no indication of the possible failure of the window installation prior to it occurring  the Applicant has stated that damage to a panel of glass on the first floor was due to vandalism, and that previous reports available (by B, on 2007 and by SP, in 2010) only refer to issues with the coating of the glass. I therefore do not accept that the Applicant was aware of (or should reasonably been aware of) the design flaw in respect of the fixing of the window fins. Accordingly, I do not accept that the FSP has proven that this exclusion applies. Faulty or defective workmanship exclusion does not apply In order for the FSP to show that this exclusion applies, it would need to show that the materials used in the fixings were faulty or defective, or that the workmanship used to install the fixing was faulty or defective. I have concluded that the design of the window fixings was flawed. There is no evidence before me to establish that the use of a grout filler as opposed to silicone constituted defective workmanship or materials (as opposed to design). Even if the use of grout was not part of the design, there is no evidence to demonstrate that this was contrary to building standards at the time. Rather, F has stated the standard of fixing may have been acceptable at the time. As the FSP has not established that any of the policy exclusions apply, it is therefore not entitled to deny the claim. Case No: 384841 Determination Page 5 of 8 3 Supporting information 3.1 Policy provisions Policy 1 – Insured Property Policy 1 is a „broad form‟ accidental loss and damage ins urance contract in terms of the Insuranc e Contracts Act 1984. What we insure We insure You up to the Sum Insured shown for Policy 1 on the Schedule, against ACCIDENTAL LOSS or DAMAGE to Your Ins ured Property which occurs during the Period of Insurance. … Exclusions – what we do not insure 1 We will not pay for loss or damage … c caused by lack of maintenance, rust, oxidation, corrosion, Wear, Tear, fading, gradual corrosion or gradual deterioration, concrete or brick cancer, developing flaws, wet or dry rot, or failure to maintain You Insured Property in a reasonably good state o f repair. d caused by non-rectification of an Insured Property defect, error or omission You were aware of, or should reas onable have been aware of . … 2 We will not pay for: … b the cost of rectifying faulty or defective materials or faulty or defective workmanship; 3.2 Reports referenced Record Key points Applicant’s building consult ant (B) General Condition Report 7 Feb ruary 2007  Inspection to report on general condition of building  Building is in fair condition for its age with general deterioration throughout and lack of adequate maintenance – work required in various areas including to windows  Windows are frameless set into concrete structure – deterioration is evident to glass coating, which appears distorted on the outer face.  No evidence or reports of window leakage  Windows are in reasonable weather - tight condition, but deterioration of the glass coating is detracting from the overall appearance of building and effectiveness of coating to prevent solar radiation  It appears coating has been damaged during window cleaning and general wear and tear Applicant’s quantity surv eyor (SP) Building upgrade estimate  Coating to existing windows has been damaged due to leaching of salt from concrete render. It appears this render has not been sealed  Other options are available but likely to be cheaper to replace windows Case No: 384841 Determination Page 6 of 8 25 March 2010  Cost to remove existing glazing, including grinding out existing grout and caulking - $23,500  Cost of new commercial section aluminum framed fixed windows (double glazed) - $258,500 Council Emergency Stop Order 6 Aug u s t 2013  External glass panels to the t op 3 rd level have shattered and there are other loose and fractured panels that may collapse without warning and cause serious injury.  There are numerous structural glass fin backings supporting the external glass panel vertical joins on the first three l evels that contain inadequate fixings that may cause further pane l s to collapse.  Broken glass has fallen onto the first level footpath canopy that may blow off onto passing pedestrians. Local council’s structural engineer ( H ) Report 6 Aug ust 2013  Building damage - inspection carried out 6 Aug ust 2013 to recommend Make Safe Work  Several panes of glass fallen from NW a n d SW corners  Glass panels supported by glass fins which are fixed into steel brackets into building frame top & bottom  In area where glass p anels have fallen, a mixture of bracke ts has been used to fix the fin s to the top of building – original fixings were imbedded into building and new fixings have been bolted into structure – suggests glass panels previously replaced due to problems  Most o f damage occurred on 3 rd fl oor of the 4 floor building  Ist fl oor showed 1 glass pane has broken previously and timber hoarding had been provided in this area – new replacement pane was evident  1 st fl oor NW corner showed 1 fin was moving at the base and ex cessive flexing of glass panels was occurring either side of fin.  Several other areas of water damage and deterioration were evidence in the building – particularly around window areas.  Recommend that one loose fin supporting glass on 1 st fl oor NW corner be supported by temp orary props  Recommend a glazing contractor conduct audit to determine condition of glazing to all areas of building, and building consultant inspect water damage areas around windows FSP’s assessor (P) Preliminary analysis report 22 August 2013  Glass breakage causation – “Maintenance issues associated with the glazing servicing the upper levels of the building were exacerbated by high winds resulting in several large elevated glass pane to dislodge and fall onto the streetscape.”  Complex has sustained previous similar incidents of glass breakage with pre - existing hoarding evident. Crude, reactive attempts at remedying the deteriorated nature of the glazing fixings within the frames were noted and observed to have limited/negligible effect at securing glazing  During inspection, adjustor personally identified that light pressure of a hand upon the glass was sufficient to rattle panes in the frame – at present, panes are unstable and could Case No: 384841 Determination Page 7 of 8 fall  General maintenance of complex appears po or, particularly the vacant upper level offices spaces. Roof drainage appears unmonitored with large volume of stagnant water, general debris, aged graffiti and avian occupation observed  Proximate cause – gradual deterioration, structural defects, movement etcetera  It would appear the damage is not the direct result of an accident or claimable event and does not appear to comprise an admissible claim.  Damage as claimed appears to be within the ambit of, but not limited to, excluded perils 1c, 1d, 1g, 1m, 2b . Applicant’s building consultant ( F ) Report 11 April 2014  Inspection to assist owner highlight probable cause of building defect which appeared as result of fixed window pane blowing in and smashing in Aug ust 2013 during high wind s  Visual inspection only (no tests) on windows after repair/replacement  All damaged windows had been replaced and all glass strengthening fins replaced and/or repaired under design/direction of structural engineer  Difficult to ascertain exactly what took place at the time (that d amage occurred)  Discussion was held with structural engineer to establish his observations at the time and his reason for the increased fixing method used in the repair  Likely to have been no signs of any deterioration of concrete dado style walls supporti ng windows at the time, and no repairs since. Windows are in original condition.  Meth od of installing glass fins as a strengthening method is not un usual – design methods can vary but single method used for all windows in this building – no reason to expec t any alternative method  Ground floor (internal) fins examined to assess original installation – inserted into a 20mmx13mm rebate in concrete, backfilled with cement mortar and some recently topped with silicon  All fins are located at the flexible silicon butt joins between panes  Likely no indication of possible failure of window installation prior to it occurring. No deterioration of concrete wall existed/exists where glass inserted. No fins are fractured or defective at or around concrete/glass junction  F ins appear to have been poorly founded and connected to the concrete support wall. T here is no evidence of silicon being used to install fin s . It is likely the fins were installed with grout filler  Grout filler is brittle and would not provide required resistance under adverse conditions  Broken glass panels have occurred to one side of a glass pane butt joint filled with flexible silicon Case No: 384841 Determination Page 8 of 8  Probable that first weakness occurred at the glass fin fixing and cracking the minimal grout filler  Flex of window at the butt end joint combined with additional wind loads have then caused windows to blow into building, the first window providing even greater loads to allow subsequent windows to break and fall  Additional stainless steel angle fixtures together with silic on filling now applied to new and existing fins is a vastly better fixing to withstand wind loads  Summary – window breakage believed to be as a result of poor standard of fixing which may have been acceptable at the time but would not be approved today. Brittle grouting used is not sufficient to provide support required. Doubtable any fault occurring could have been foreseen until fins broke away FSP’s assessor (P) Report 3 9 May 2014  Retrospective report by B does not unequivocally verify circumstance surrounding claim  Principal factor is the inadequate/defective fixing of the windows/window fins. This was readily observable.  Redesign by structural engineer testifies to the defective nature of windows.  Storm/tempest and high wind not a factor in failur e of windows.  Comprehensive evidence of previous problems with glazing and pre - existing knowledge of same is unequivocal.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.