Text of the determination
Determination
General Insurance - Small Business Insurance - Commercial Property - FSP Decision -
Denial of Claim - No Insured Event
Determination
Case No: 384290 Determination Page 1 of 10
Case number: 384290 8 July 2015
1 Overview
1.1 Dispute
The Applicant held a business insurance policy with the Financial Services
Provider (FSP) which provided cover for his restaurant business. He lodged a
claim under the policy for property damage and business interruption following a
fire at a neighbouring property in January 2013.
The FSP cash settled the Applicant’s claim for approximately $450,000 and the
Applicant signed a release form. However, the Applicant says the settlement
amount does not fully indemnify him for damage to various items of equipment
used in the business. He also seeks reimbursement of professional costs incurred
during the claim process.
1.2 Issues and key findings
Is the FSP liable for the disputed damage?
The FSP did not fully test all of the Applicant’s electrical items following the fire
and related events in January 2013. Accordingly, it is possible that some of these
items sustained damage which has not previously been assessed. The difficulty of
accurately determining the extent of such damage has been exacerbated by the
Applicant’s treatment of these items since they were returned to him.
In these circumstances, it is appropriate that liability for damage to the untested
items be shared between the FSP and the Applicant. The release signed by the
Applicant does not prevent him from pursuing his claim, as the FSP had expressly
agreed to reconsider this aspect of the claim.
Is the Applicant entitled to payment of professional costs?
The services for which the Applicant seeks payment were not reasonably required
for the purposes of the claim which is the subject of the current dispute .
1.3 Determination
This Determination is partly in favour of the Applicant.
The FSP is to pay the Applicant an additional amount of $20,000 in full and final
settlement of his claim. The Applicant is not entitled to reimbursement of his
professional costs.
2 Reasons for Determination
Case No: 384290 Determination Page 2 of 10
2.1 Is the FSP liable for the disputed damage?
Signed release does not prevent Applicant from pursuing dispute
The FSP accepted liability for the Applicant’s claim in early February 2013,
several weeks after the fire. However, the FSP then entered into protracted
negotiations with the Applicant’s broker and claims preparer regarding an
appropriate settlement amount.
On 9 September 2013, the Applicant signed a release form agreeing to accept the
amount of $446,358.42 paid by the FSP in full and final settlement of all claims
arising out of the fire in January 2013.
The total paid by the FSP included amounts in respect of the Applicant’s claim for
business interruption, as well as for damage to various items used in the
business, includ ing tenant’s fixtures and fittings, stock in trade and business
equipment and machinery.
The FSP says that, by signing the release form, the Applicant accepted the
settlement amount and agreed to discharge the FSP from all further liability. On
this basis, the FSP says the Applicant should be prevented from disputing the
adequacy of the settlement amount.
The Panel accepts that, in some circumstances, it will be appropriate to treat an
unconditional release as binding on the insured. In particular, the Panel would be
reluctant to allow an insured to depart from the terms of a release where, as in the
Applicant’s case, they have had the benefit of extensive professional advice
throughout the claim process.
However, in the present case, correspondence between the parties indicates that
the release was signed on a conditional basis, subject to confirming any additional
damage to certain items of electrical equipment used in the restaurant business.
The Applicant says that this matter was left open due to concerns that some of
the equipment had not been comprehensively tested and may fail to operate
when installed at the Applicant’s new premises.
In an email to the Applicant’s broker dated 28 August 2013, the FSP confirmed
that, should any of the items of electrical equipment fail to operate, it would
reconsider its liability for such items on a case by case basis, subject to proof that
the items had been damaged by the fire.
On 9 September 2013 (the day the re lease was signed), the Applicant’s broker
emailed the FSP confirming that the Applicant was not cash settling on the
electrical equipment. In response, the FSP confirmed its agreement to further
review these items.
In these circumstances, the Panel considers that the signed release form does
not prevent the Applicant from pursuing his dispute, so far as it concerns claimed
damage to the items which the FSP had agreed to reconsider.
While the FSP agreed to reconsider its liability for damage to these items, it did so
only on the basis that some of the items may not have been fully tested, and
Case No: 384290 Determination Page 3 of 10
subject to further testing revealing previously unidentified damage attributable to
the fire.
In these circumstances, and having regard to the terms of the release signed by
the Applicant, the Panel considers that the scope of the current dispute should be
limited to those items of electrical equipment which had not been fully tested at
the time the release was signed.
Dispute concerns extent of damage to electrical equipment
The Applicant seeks cover for damage to a number of items of electrical and
electronic equipment used in his restaurant business, including various kitchen
appliances, Point of Sale (POS) equipment and miscellaneous communications
equipment.
The Applicant says the equipment sustained damage due to the combined effects
of:
smoke which affected the premises during the fire;
water and chemicals used to extinguish the fire;
rainwater which entered the premises after the roof collapsed due to a severe
storm which occurred two weeks after the fire; and
the equipment being left in a damp and humid environment for a further six
weeks, while investigations into the cause of the fire were completed.
In his earlier submissions to FOS, the Applicant sug gested that the FSP’s failure
to appropriately clean and store the items may have contributed to the current
damage. However, in his most recent submissions, he confirmed that all of the
damage for which he is claiming occurred prior to the removal of the items from
his premises in April 2013.
The Applicant says that, as a result of this damage, the equipment is no longer
operational and requires complete replacement, at an estimated cost of over
$90,000.
The Applicant’s policy provides cover for damage t o the equipment caused by the
events listed in the policy (including fire and storm). The policy also provides
cover for accidental damage not caused by one of the listed events.
The FSP accepts that the Applicant’s property was affected by the fire and
subsequent storm in January 2013. However, the FSP considers that the
Applicant’s electrical equipment suffered superficial soot contamination only as a
result of the fire and related events.
The FSP offered the Applicant an amount of $20,000 for the costs of cleaning the
electrical equipment and other items at the property, based on a quote for
$12,100 provided by its cleaning contractor (plus a contingency amount).
The Applicant had expressed a preference for the cleaning costs to be cash
settled, after the FSP initially offered to arrange for its contractor to undertake the
cleaning. It appears this amount was included in the cash settlement instalment
paid to the Applicant in May 2013.
Case No: 384290 Determination Page 4 of 10
The FSP says that, to the extent the electrical equipment showed sig ns of
damage when re-tested in September/October 2014, this damage is due to the
Applicant’s failure to take steps to prevent any further damage to the equipment
after the fire.
In particular, the FSP says the Applicant failed to arrange for the cleaning of the
equipment and appears to have stored the equipment in inadequate conditions
after it was returned to him in September 2013.
FSP was required to assess damage to electrical equipment
As outlined above, the FSP disputes that the Applicant’s electrical equipment
suffered any significant damage due to the fire and related events, other than
relatively minor soot contamination.
The FSP refers to a report prepared by its assessor (CL) in May 2013 following an
inspection of the property, in which CL described the damage from the fire as
limited to “a light coating of combustion by - products”.
In his report, CL refers to a report from the FSP’s building consultant (MB), in
which MB apparently concluded that there was no significant water entry to the
premises, either during the fire or the subsequent storm. The Panel has not been
provided with a copy of MB’s report.
The Applicant has provided photographs of the restaurant kitchen after the fire
and the subsequent storm, which show debris from the collapsed ceiling and
water marks to the tops of the walls.
Based on the information provided, the Panel accepts that the fire and
subsequent storm certainly had the potential to cause damage to the Applicant’s
electrical equipment. In these circumstances, the FSP was obliged to assess the
equipment in order to determine the extent of the damage caused.
FSP did not fully test all electrical equipment
Once the police investigation was finalised and access to the premises became
available, the FSP arranged for the Appl icant’s equipment to be moved and
stored at a warehouse.
The FSP arranged for an electrical contractor (AC) to inspect and test 34 items of
electrical equipment in order to identify any smoke or water damage.
AC inspected the items in April 2013 and reported that none of the items showed
signs of smoke damage or water entry. He prepared a schedule detailing the test
results for each item, which indicated that many of the items were found to be
operating normally.
The Applicant has provided a copy of an email from his claims preparer (M) which
disputes AC’s findings and says his conclusions lack supporting reasons. He has
also provided copies of reports from his POS equipment supplier (C) and his
electrician (J) which state that all the electrical eq uipment in the kitchen have
been damaged as a result of the fire and related events, and need to be replaced.
Case No: 384290 Determination Page 5 of 10
The Panel notes that the reports provided by the Applicant’s contractors are
expressed in very general terms and do not specify the nature and extent of the
tests conducted on the relevant equipment or, in the case of J’s report, provide
details of the specific items tested.
In these circumstances, the Panel is inclined to give more weight to the results of
the inspection and testing carried out by the FSP’s electrical contractor (AC).
However, the Panel notes that AC’s report reflects that some of the items
inspected were unable to be fully tested. In particular, AC’s reported that:
the POS equipment (including waiter pads) could not be connected to a
network and therefore their operation could not be tested;
several items with 15 amps plug tops and three phase items were tested for
earth continuity and insulation but were not tested under operational
conditions; and
other items (such as the pizza oven and glass washer) were not powered up
and therefore their operation could not be confirmed.
In these circumstances, the Panel considers that AC’s report leaves open the
possibility that there may have been further damage to the above items, which
was not identified by the testing carried out by AC. Accordingly, it is necessary to
consider the further information obtained when these items were retested in
September/October 2014.
FSP is not liable for damage to POS equipment
As outlined above, AC’s init ial inspection of the POS equipment in April 2013 did
not identify any smoke or water damage.
After the Applicant raised concerns about damage to the POS equipment, the
FSP arranged for the equipment to be re-tested by an electronic engineer (AE) in
October 2014.
AE reviewed each of the items used in the POS system and confirmed AC’s
opinion (based on his inspection in April 2013) that none of the equipment
showed any signs of smoke damage or water entry. He also confirmed that the
circuit boards were clean with no evidence of corrosion or chemical
contamination.
AE noted that some of the equipment did not work on initial testing because the
internal connectors had been disconnected. Once this issue was resolved, the
POS equipment exhibited various problems, including:
errors and intermittent rebooting of the touch screen terminals;
a catastrophic failure of the battery in the UPS;
poor connections in the waiter pad terminals; and
missing fuses in the waiter pad network control.
AE concluded that the issues with the POS equipment were not caused by the fire
and related events, but were due to wear and tear and poor maintenance.
AC (who had arranged for the inspection by AE) confirmed that by October 2014
the equipment was in very poor, dirty and weathered condition, compared to its
condition when inspected in April 2013 (as shown in photographs taken at the
Case No: 384290 Determination Page 6 of 10
time). It appears that, to some extent, this may have been due to the manner in
which the equipment was stored after it was returned to the Applicant.
The report prepared by the Applicant’s POS supplier (CC) states that the POS
system has suffered water, chemical and smoke damage from the fire, with some
items of equipment not working at all and other items operating only intermittently.
CC states that all of the equipment will need to be totally stripped and all parts
cleaned, which would exceed the replacement cost.
However, it is not clear from CC’s report to what extent he carried out an internal
inspection of the equipment, including the circuit boards. Further, it is possible
that at least some of the issues observed by CC were caused by the internal
connectors having been disconnected.
Based on the available information, the Panel is not satisfied that the POS
equipment suffered any material damage as a result of the fire and related events.
The Panel considers that, on the balance of probabilities, the issues with the POS
equipment were caused by wear and tear and lack of maintenance.
Extent of electrical damage to other items cannot be conclusively
determined
As outlined above, not all of the remaining items of equipment were fully tested by
AC at the time of his original inspection in April 2013. These items include the
pizza oven, the washing machine, the coffee machine, the hot shelf, the glass
washer and two speakers.
Accordingly, it is possible that some of these items sustained damage due to the
fire and related events (despite no specific smoke or water damage having been
identified during the initial inspection).
The schedule attached to the quote prepared by the FSP’s cleaning contractor
(W) in February 2013 indicates that the pizza oven had suffered electrical water
damage, although it is unclear on what basis W reached that conclusion.
The Applicant has provided reports from contractors engaged to repair the pizza
oven after it was installed at his new premises which indicate that the oven
suffered ongoing malfunctions, which were attributed to water damage.
The report provided by the Applicant’s electrician (J) states that his visual
inspection and insulation tests identified water in the pizza oven, “all of the kitchen
appliances” and “all of the electrical equipment in the kitchen area”. However, it is
not clear whether J tested all of the items which are the subject of the current
dispute.
After the Applicant raised concerns about further, unassessed damage to his
electrical equipment, the FSP arranged for these items to be reinspected by AC in
September 2014. However, because of the poor condition of the equipment at
that time, AC was unable to test the equipment due to safety concerns.
In these circumstances, there is insufficient information to determine with any
certainty the extent to which these items of equipment were damaged by the fire
and related events.
Case No: 384290 Determination Page 7 of 10
In part, this is due to the FSP’s failure to fully test the equipment in the period
after the fire. However, the subsequent deterioration of the condition of the
equipment (due to the manner in which it has been stored by the Applicant) has
also contributed.
The situation has been exacerbated by both parties having agreed to settle the
claim in September 2013 without all outstanding issues having been resolved. It
would have been in the best interests of all concerned for the extent of the
damage to the electrical equipment to have been quantified before the release
was signed.
FSP should contribute to replacement cost of certain electrical items
In light of the issues identified above, the Panel considers that it is appropriate
that liability for the cost of replacing the outstanding items of electrical equipment
be borne by the FSP and the Applicant in equal proportions. The relevant items of
equipment are those which were not fully tested by AC in April 2013 (other than
the POS equipment).
Based on quotations provided by the FSP’s equipment supplier (SW), the
estimated cost of replacing these items of equipment is approximately $50,000
(including repair costs incurred by the Applicant in relation to the pizza oven).
The Panel notes that the FSP has already cash settled the Applicant for $20,000
in relation to cleaning costs, of which the Panel considers approximately $5,000 is
reasonably attributable to the costs of cleaning the relevant items.
On this basis, the Panel considers that it is fair in all the circumstances that the
FSP pay the Applicant an additional amount of $20,000 in full and final settlement
of his claim.
The Panel notes t hat the Applicant’s professional advisers apparently advised him
to settle the claim and sign the release form in September 2013, without the
outstanding issue relating to the electrical equipment having been resolved.
Further, it appears that the Applican t’s representatives did not make any further
claim for payment until July 2014, over nine months later.
In these circumstances, the Panel considers that the FSP is not responsible for
the bulk of the delays in finalising the claim. Accordingly, the FSP is not required
to pay interest on the additional settlement amount.
FSP is not liable for impact damage
The Panel notes that, in addition to damage caused by the fire and related events,
the Applicant says the pizza oven and a refrigerator were damaged by the FSP’s
contractors while being returned to the Applicant from the FSP’s contractor’s
warehouse in September 2013.
The Applicant has provided photographs showing impact damage to these items.
However, based on the available information, the Panel is not satisfied that the
claimed damage was caused by the actions of the FSP’s contractors in
September 2013.
Case No: 384290 Determination Page 8 of 10
The Panel notes that the Applicant appears not to have raised concerns about
this damage until December 2014, more than a year after the items were returned
by the FSP’s contractors.
As outlined above, the policy provides cover for accidental damage to the
Applicant’s business property. Accordingly, it is possible that he may be able to
lodge a separate claim for this damage.
2.2 Is the Applicant entitled to payment of his professional costs?
Applicant is not entitled to indemnity under the policy
The policy provides that the FSP will reimburse the Applicant for costs of up to
$25,000 which are necessarily and reasonably incurred for the purposes of
preparing a claim for which the FSP has accepted liability under the policy.
However, the policy states that such costs will only be paid where the Applicant
has obtained the FSP’s prior written consent.
As outlined above, the Applicant engaged a claims preparer (M) to assist with the
preparation of his claim. Copies of correspondence between the parties during the
claim suggest that M’s involvement related primarily to the Applicant’s claim for
business interruption (which is outside the scope of the current dispute).
The FSP paid the Applicant more than $25,000 for his claims preparer’s fees in
relation to the business interruption claim, under an additional benefit provided for
under the business interruption cover.
In his initial submissions to FOS, the Applicant sought reimbursement of
additional fees paid to his claims preparer (M) for assistance in relation to the
property damage aspects of his claim. The FSP had previously refused to provide
its consent for these fees when approached by the Applicant in early 2013.
However, in his recent email of 21 April 2015, the Applicant indicated that the only
claim preparation costs he is now seeking to recover are fees of $3,663 invoiced
by his accountant in March 2013.
The Applicant seeks indemnity for these fees under the general claims
preparation benefit referred to above, rather than under the additional benefit
provided for under the business interruption cover.
However, the invoice provided by the Applicant’s accountant indicates that the
services provided relate to the preparation of financial statements, discussions
with the Applicant and his broker in relation to the financial accounts, updating of
payroll records and preparation of reports.
On this basis, the fees for which the Applicant seeks reimbursement do not
appear to relate to the property damage claim which is the subject of this dispute.
Accordingly, the Panel is not satisfied that the Applicant is entitled to indemnity for
these fees under the general claims preparation benefit.
Case No: 384290 Determination Page 9 of 10
Applican t is not entitled to reimbursement of broker’s fees
The Applicant incurred costs of $3,300 in fees paid to his broker for assistance
during the claims process.
Under paragraph 9.4 of the FOS Terms of Reference, FOS may require a
financial services provider to contribute to legal or other professional costs
incurred by an applicant in the course of their dispute.
The FOS process is designed to be accessible to applicants without the need for
professional advice. Accordingly, FOS considers that the reimbursement of
professional fees is only appropriate in limited circumstances (for example, where
a dispute raises complex legal or technical issues).
The Applicant says that his claim was complicated due to a number of factors,
including the delay due to the p olice investigation, his landlord’s decision to
demolish (rather than repair) the building, the extent of information requested by
the FSP and the need for the Applicant to travel overseas due to a family illness.
The Panel accepts that there were aspects of the claim which reasonably required
the Applicant to obtain professional assistance. However, the Panel is satisfied
that these primarily concerned the Applicant’s claim for business interruption,
rather than his property damage claim.
The Panel considers that the matter which is the subject of the current dispute
(being the extent of damage to the electrical equipment) was conceptually
straightforward.
In these circumstances, the Panel is not satisfied that it was necessary for the
Applicant to seek the paid assistance of his broker. While the Applicant was
entitled to engage his broker to manage the dispute on this behalf, he did so at his
own risk.
Accordingly, the FSP is not required to reimburse the Applicant for the fees paid
to his broker.
Case No: 384290 Determination Page 10 of 10
3 Supporting information
3.1 FOS approach to this dispute
This dispute has not been the subject of a FOS Recommendation. Due to the
nature of the dispute, it has been referred directly to a Panel for Determination, in
line with the Operational Guidelines to the FOS Terms of Reference. The Panel
consists of an Ombudsman and two representatives with consumer and insurance
experience.
The Panel has decided this case on its merits, having regard to the relevant law,
good industry practice, codes of practice and previous FOS decisions.
There has been a full exchange of all material information relied on for the
purposes of this Determination and each party has had the opportunity to address
any issues raised by the other.
The Panel has reviewed and considered all of the material provided by the
parties. While the parties have raised a number of issues in their submissions, for
the purposes of this Determination the Panel has restricted its commentary to
those issues which it considers directly relevant to the outcome only.
The Applicant has been assisted by his broker during the course of this dispute.
For the purposes of this Determination, submissions made by the Applicant’s
broker have been treated as if they have been made by the Applicant himself.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.