Determination 384210

Denial of balcony storm damage claim

FirmFinancial Firm (Unknown - Insurer)
Decided2015-05-28
ProductGeneral Insurance · Home building and contents
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant's balcony was damaged after a storm and the FSP denied the home insurance claim under exclusions for gradual deterioration, inherent defects, faulty workmanship and faulty design. AFCA found the FSP had proven the exclusions applied and ordered nothing.

Once accidental damage was established, the insurer proved on balance that excluded causes produced the loss, and section 46 of the Insurance Contracts Act did not apply because the exclusions did not depend on pre-contract condition.

Issues

Subjects and remedies

home or building damagenatural disasterno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim Determination Case No: 384210 Determination Page 1 of 7 Case number : 384210 28 May 2015 1 Overview 1.1 Dispute The Applicant lodged a claim on his home and contents policy held with the Financial Services Provider (FSP), after he discovered damage to his balcony following a storm. The FSP denied the Applicant’s claim on the grounds the cause of the damage was specifically excluded from cover. 1.2 Issue and key findings Can the FSP deny the Applicant’s claim ? The FSP can deny the Applicant’s claim because the FSP has established that the damage was caused by gradual deterioration, inherent defects, faulty workmanship and faulty design which are excluded by the policy. 1.3 Determination This Determination is in favour of the FSP. The FSP is entitled to deny the claim. Case No: 384210 Determination Page 2 of 7 2 Reasons for Determination 2.1 The FOS Approach I have determined this dispute based on what is fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous Financial Ombudsman Service (FOS) decisions. I have taken into account all the material submitted by the parties. There has been a full exchange of all documents relied on to make this Determination and each party has had the opportunity to address any issues raised by the other. This dispute has proceeded straight to a Determination. No Recommendation was issued. 2.2 Can the FSP deny the Applicant’s claim ? The policy covers accidental damage The Applicant’s claim, lodged in November 2013, followed a storm on 26 January 2013 and continual bad weather. The Applicant said the weather caused damage to the balcony which has continued to worsen. The policy provides cover for accidental damage. As there is no dispute the damage was unintended and unexpected, the damage has been caused by an insured event. The onus therefore shifts to the FSP to prove, on balance, the loss is not covered or is otherwise excluded. The FSP has established the damage was excluded under the policy The FSP denied the Applicant’s claim based on the exclusions relating to gradual deterioration, inherent defects, structural defects, faulty workmanship and / or faulty design. The relevant extracts from the policy are set out in section 3.1 below. The FSP relies on evidence provided by its own experts and the Applicant’s expert. The expert reports are summarised in section 3.2 below. All of the experts agree the damage had been occurring over a period of time and was caused by a breakdown of the waterproofing membrane. This membrane failed because it was penetrated when a hand rail was installed. Additionally, there are other issues with the construction of the balcony, in particular the way in which the edge of the balcony was sealed. No drip edge protection was installed to the outer tile and the aluminium strip on the face of the balcony was not sealed, allowing water to seep in between the tiles and the strip. The Applicant submits that the roof over the balcony means a severe storm would be required in order to penetrate the balcony. I do not accept this, given the roof is Case No: 384210 Determination Page 3 of 7 high and rain often falls on an angle. The design of the balcony should be able to withstand this. The Applicant also asserted he could not reasonably have known of the flaw with the balcony design. However, the exclusions are not reliant on the Applicant’s knowledge of the fault. Further, the FSP does not need to establish that the timber beam didn’t break until after the storm. Rather, the FSP must establish that an exclusion applies to deny the claim. The FSP has proven, on balance, the damage has been caused by gradual deterioration, inherent defects, faulty workmanship and faulty design. As such, the FSP can deny the Applicant’s claim. 2.3 Section 46 does not assist the Applicant The Applicant’s broker has presented an argument that section 46 of the Insurance Contracts Act 1984 (Cth) (the Act) may apply to assist the Applicant in this matter. Section 46 of the Act provides that an insurer may not rely on an exclusion which relates to the condition of something (such as the balcony) before the contract was entered into, if it was reasonable for the insured not to have been aware of that condition. For example, an exclusion regarding a pre-existing illness may not apply if the insured was not reasonably aware of the illness prior to entering into the contract of insurance. In the present dispute, the FSP is not relying on an exclusion specifically relating to the condition of the balcony prior to when the contract was entered into. Rather the exclusion relates to structural and inherent defects, faulty workmanship and gradual deterioration, that can have occurred at any time. As such, section 46 does not apply to assist the Applicant. Case No: 384210 Determination Page 4 of 7 3 Supporting information 3.1 Policy wording The following sections of the Product Disclosure Statement (PDS) apply in this instance: “ What we will not pay for We will not cover your home or your contents for any loss or damage caused by: … Rust, corrosion, gradual deterioration, depreciation, wear or tear. … Inherent defects, structural defects, faulty workmanship or faulty design …” 3.2 Expert Evidence Record Key points Applicant’s builder (WB ) Report and Quotation 14 November 2013 “[WB] inspected the damage deck and found the deck to be unsafe for use and needing to be replaced ASAP. We believe that this damage is due to un seasonal weather conditions in which the area has endured over the previous seasons.” (sic) FSP’s builder (RP ) Report 22 November 2013  The method of tiling to the edge of the balcony an d the cladding to the balcony does not allow moisture to run off the balcony (waterproofing method failure).  The cause of the damage is due to continual exposure to moisture entering the face of the balcony over a period of time.  One single event would not be the contributing factor, but rather continual exposure to moisture.  There is a failure of the waterproofing method used.  Water could be entering through the fixings of the stainless steel posts for the hand rail if they were not sealed cor rectly when they were installed, however this could not be confirmed without destructive investigation.  The front beam supporting the balcony has rotted and sagged and is not safe to walk on.  The heads over bi - fold doors and windows have sagged.  There are signs o f movement to the rendered blue board sheeting above these doors and windows.  Damage has occurred to the balcony from a water proofing failure. FSP’s engineer (JH) Report 20 December 2013  The damaged area is a tiled balcony on the upper level of the Appli cant’s home.  There was a distinct curvature of the outer edge of the balcony, water damage to the underside soffit, water staining to cement sheeting and down the masonry columns which support the balcony. Case No: 384210 Determination Page 5 of 7  The face of the balcony is rendered cement sheetin g with an aluminium edge – the size of this indicates a structural support beam lies inside the façade.  The stainless steel handrails are screw fixed directly onto the tiled floor with hexagonal drive screens. These are corroded.  There is no drip edge or b low back protection of the outer facades.  The screws holding the handrails directly to the tiles are corroded.  The bi - fold doors on the lower level under the balcony no longer open.  Temporary protection was in place to prop up the balcony and prevent it fr om collapse.  A Hydraulic Level Survey indicated a significant defle ction in the outer balcony beam of 51mm.  It appears the outer balcony beam has failed.  The cause of the failure is two - fold :  The handrail screws have penetrating the waterproofing membrane, allowing water to enter into the floor framing and beam causing rotting of the timber.  There is no drip edge protection to the outer tile edge. This means that the water proof membran e does n o t continue over the floor edge and down onto th e ou t side face of the cement sheeted façade . Water has therefore decay ed the floor framing.  The balcony was not constructed in accordance with relevant building codes.  Water has been slowly leaking into the floor framing of the balcony for a longer period of time. FSP’s engineer (JH) Second Report 14 January 2014  The water staining would have been evident prior to the storm event of January 2013 – this is based on the “white” water stain marks which cannot be gene rated directly after a single rain event.  Additionally, the timber beam has rotted and rot cannot occur within 72 hours of a single event, rather it occurs after continual saturation and long term moisture exposure.  The balcony features a high architectura l roof indicating the edges of the balcony would become wet during a normal rain shower.  The roof would probably not provide enough protection to the balcony to keep in completely dry during normal rain.  Additionally, most rain falls are associated with so me winds or breezes causing rainfall to be angled. Applicant’s builder (TB) Report 5 February 2014  T he Applicant’s wife first noticed the sagging of the balcony around July 2013.  She had also noticed minor water marks on the rendered blue board on the front of the balcony however believed it Case No: 384210 Determination Page 6 of 7 to be normal water run off from the balcony.  Confirmed the front bearer to the balcony has failed which has caused the balcony to sag.  The sta inless hand rail post has been installed directly over the failed section of the bearer – it appears at installation, the hand rail posts have compromised the waterproof membrane to the balcony.  It is unreasonable to assume that the water staining would in dicate there was damage occurring to the beam. The owners would not have reasonably known that the bearer was water damaged. FSP’s engineer (JH) Third Report 11 March 2014  The opinion of JH has not changed based on the additional information provided by the Applicant and his experts.  Given the extent of the deflection of the outer beam, it is likely that the beam has been gradually deflecting over at least the last 3 to 5 years.  It is not possible that a single event would case the balcony to deflect as t he strength of the timber would have slowly decreased as the decay developed after each period of rain, slowly breaking down the timber fibres resulting in gradual beam deflection.  Had the deck been constructed in accordance with relevant building codes, standards and manufacturer guidelines, the failure would not have occurred.  There were indicators that the deck was slowly failing, such as corroding light fittings, cracks and doors sticking. Applicant’s builder (TB) Report 15 October 2014  A section of the fibro cement ceiling sheet directly under the damaged area was cut out and found that the front laminated beam was totally rotten and starting to crumble .  There is an aluminium strip to the face of the tiled balcony and this aluminium strip has now pul led away from the tiled areas at the top exposing the fact that the aluminium strip was only grouted and not sealed  TB is of the opinion that water has also been seeping in between the tiles and aluminum strip .  O ver time this has caused the front laminated timber beam to slowly rot.  The insured would not have known this damage was happening until the beam collapsed. 3.3 Section 46 of the Act Section 46 of the Insurance Contracts Act 1984 (Cth) provides: 1. This section applies where a claim under a contract of insurance (other than a contract of insurance that is included in a class of contracts declared by the regulations to be a class of contracts in relation to which this section does not apply) is made in respect of a loss that occurred as a result, in whole or in part, of a defect or im perfection in a thing. Case No: 384210 Determination Page 7 of 7 2. Where, at the time when the contract was entered into, the insured was not aware of, and a reasonable person in the circumstances could not be expected to have been aware of, the defect or imperfection, the insurer may not rely on a provision included in the contract that has the effect of limiting or excluding the insurer's liability under the contract by reference to the condition, at a time before the contract was entered into, of the thing.