Home / Financial Firm (Unknown - Insurer) / Determination 384164

Determination 384164

claim_denial

FirmFinancial Firm (Unknown - Insurer)
Decided2015-05-21
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded$2,650
Non-financial loss—
Amount claimed$66,835
SourceAFCA PDF

Summary

The Applicant's kitchen floor subsided, and the FSP denied the claim as damage from poor ventilation and wear. AFCA found the leaking pipe caused part of the damage, so the parties share the repair costs equally, the FSP must cash settle 50% of the repair cost once a scope of works is obtained, and it must reimburse $2,650 in leak-location and engineer costs.

The damage was caused by both uncovered sub-floor moisture from poor ventilation and a covered leaking pipe, and the proportions could not be determined, so costs are shared equally.

Issues

Subjects and remedies

pay claimpay compensation

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of Claim - Exclusion/Condition Determination Case No: 384164 Determination Page 1 of 8 Case number : 384164 20 April 2015 1 Overview 1.1 Dispute The Applicant lodged a claim under her home insurance policy with the Financial Services Provider (FSP) after she noticed her kitchen bench sinking in mid-2011. The Applicant believed the damage was due to a leaking waste pipe under the kitchen floor. The FSP denied the claim on the basis that the damage was not caused by the leaking pipe but by factors such as inadequate ventilation and poor construction (which are not covered under the policy) and/or wear and tear, deterioration and corrosion (which are expressly excluded under the policy). 1.2 Issues and key findings Is the FSP liable for the damage? The available information establishes that, on the balance of probabilities, at least part of the claimed damage was caused by the build -up of moisture in the sub- floor area over an extended period of time due to inadequate ventilation, as a result of the manner in which the extension was constructed. This led to the gradual deterioration of the timber joists and bearers. Damage caused in this manner is not covered under the policy However, the leaking pipe identified in November 2011 allowed further moisture to escape into the sub-floor area, resulting in additional damage to the timber framework (which ultimately led to the subsidence of the floor). Damage caused in this manner is subject to cover under the policy. How should the claim be settled? Given the claimed damage is attributable to both the poor construction of the extension and the leaking pipe, it is fair in all the circumstances that the Applicant and the FSP bear the costs of repairing the damage equally. 1.3 Determination This Determination is partly in favour of the Applicant. The FSP is to pay the Applicant an amount equal to 50% of the costs of repairing the claimed damage (including temporary accommodation if required), based on a Case No: 384164 Determination Page 2 of 8 scope of works and quotation to be obtained in accordance with section 2.2 below. The FSP is to pay the Applicant an additional amount of $2,650 as reimbursement of costs incurred in locating the source of the water leak and obtaining her engineer’s report. Case No: 384164 Determination Page 3 of 8 2 Reasons for Determination 2.1 Is the FSP liable for the damage? Application of policy depends on cause of damage The Applicant is required to show that, on the balance of probabilities, she has suffered a loss caused by a risk insured against under the policy. This is known as a prima facie claim. If the Applicant is able to establish a prima facie claim, then the onus shifts to the FSP to show that, on the balance of probabilities, it is entitled to rely on an exclusion under the policy or is otherwise entitled to deny the claim. The policy provides cover for damage to the Applicant’s property caused by the events listed in the policy (including the sudden and unexpected escape of liquid from a fixed pipe), subject to the conditions and exclusions set out in the policy. While the event of “escape of liquid” refers to the relevant liquid escaping “suddenly and unexpectedly”, the policy separately makes clear that it also covers the slow escape of liquid over an extended period of time in circumstances where the Applicant could not reasonably be expected to have been aware of the leak. The Applicant has provided a report from her plumber (AB) which confirms that in November 2011 he repaired a broken waste pipe which had been leaking under the house. The Applicant has also provided a report from her engineer (VC) which confirms that the timber floor frame and floorboards in the kitchen have been damaged by exposure to moisture over an extended period of time. Based on his inspection of the sub-floor, VC considered that the damage had been caused by the leaking waste pipe. The FSP acknowledges that there was a broken pipe which had been leaking under the kitchen floor. The FSP also accepts that the damage to the kitchen floor has been caused by deterioration of the timber bearers and joists due to excessive moisture over an extended period of time. However, based on the report of its engineer (DW), the FSP says that the nature and extent of the damage is not consistent with it having been caused by a leaking pipe. The FSP says that the damage was caused by the build-up of moisture in the sub-floor over an extended period of time as a result of inadequate ventilation and poor construction techniques. Damage caused in this manner is not covered under the policy. The FSP says that such damage also falls within the general exclusions under the policy for damage caused by wear and tear, deterioration, mould and rising damp. Accordingly, it is necessary to determine the cause of the damage to the Applicant’s kitchen floor. Sub-floor area had inadequate ventilation Case No: 384164 Determination Page 4 of 8 The kitchen area where the damage occurred was built as part of an extension to the home constructed a number of years earlier. The extension was built on a concrete slab, which was installed over an existing timber floor. The claimed damage consists of moisture damage to the original timber joists, bearers and floorboards located under the newer concrete slab and tiles. This damage has resulted in gradual deterioration of the timber framework which has ultimately caused the slab to sink, most notably at the expansion joint between the concrete slab for the extension and the original timber flooring for the main part of the house. The reports prepared by the various contractors confirm that the manner in which the extension was constructed did not leave any openings in the foundation brickwork, resulting in poor ventilation of the sub-floor area. The lack of adequate ventilation was noted by the FSP’s assessor (J), builder (AG) and engineer (DW), as well as by the Applicant’s pest expert (A) and engineer (VC). The FSP’s engineer (DW) concluded that the moisture damage to the original timber flooring was due to the ongoing effects of naturally occurring ground moisture in the poorly ventilated sub -floor area. DW noted that the stains to the various joints and bearers appeared to be random and there was no evidence of localised damage concentrated in the area of the leaking pipe. While the Applicant says that DW conducted a cursory inspection only of the sub - floor area, the Panel notes that his report includes several clear and detailed photographs of the relevant area taken by DW during his attendance at the property. Having carefully reviewed these photographs (together with the additional photographs provided by the Applicant ’ s engineer (VC)), the Panel considers that they indicate that significant moisture damage was observed in sections of the floor beyond the area of the leaking pipe. The Panel notes that the Applicant’s builder (CC) had previously confirmed that the moisture damage to the timber frame and particle board flooring was most pronounced in the corner of the kitchen where there was less than 300 millimetres between the timber joists and the natural ground level, allowing extremely limited ventilation. The Applicant’s pest expert (A) also reported decay in the timber bearers and joists located under the main bedroom toilet. For the reasons outlined above, the Panel is not satisfied that the bulk of the claimed damage was caused by the leaking pipe. The Panel considers that, on the balance of probabilities, a significant portion of the damage was caused by the build-up of moisture in the sub-floor area over an extended period of time, due to the inadequate ventilation in the sub-floor area, as a result of the manner in which the extension was constructed. This has resulted in the gradual deterioration of the timber framework and contributed to the subsidence of the kitchen floor. Leaking pipe contributed to damage Case No: 384164 Determination Page 5 of 8 While the Panel considers that part of the claimed damage occurred over time as a result of inadequate ventilation, the Panel is also satisfied that the leaking pipe identified in November 2011 contributed to the claimed damage. The Applicant’s builder (CC) stated that when he inspected the sub -floor area in May 2012, he found the area to be damp, indicating that water had accumulated in the area for a prolonged period of time. CC considered this to be due to the effects of the leaking pipe. When CC re-inspected the sub-floor area in June 2012, he noted that the soil appeared to be drying out, relative to his early inspection. This suggests that the leaking pipe contributed to the moisture content of the sub-floor soil (although it is noted that both inspections occurred after the leaking pipe had already been fixed). The Applicant’s engineer (VC) carried out a thorough inspection of the sub -floor area in November 2012, during which he observed residual material on the barrier and joint of the waste pipe (indicating a prior leak) and contaminated soil (which he considered to be due to the effects of leaking waste). The FSP’s engineer (DW) disputes that the volume of waste leaking from the pipe would have been significant enough to cause the extent of deterioration to the timber framework observed. However, based on the available information, the Panel is satisfied that the leaking waste pipe identified in November 2011 did contribute to the claimed damage by allowing further moisture to escape into the sub-floor area, causing additional damage to the timber framework which ultimately resulted in the subsidence of the kitchen floor. Damage is attributable to both leaking pipe and inadequate ventilation As outlined above, the Panel is satisfied that the inadequate sub-floor ventilation provided when the extension was constructed contributed to the build-up of moisture in the sub-floor area and the gradual deterioration of the timber framework over a prolonged period of time. The Panel notes that damage of this nature typically occurs gradually over an extended period of time and would not have been immediately apparent to the Applicant. To the extent that the damage was caused by naturally occurring ground moisture and inadequate ventilation, it is not covered under the policy (which provides cover for damage caused by the listed events only). However, the Panel is also satisfied that the leaking pipe identified in November 2011 allowed further moisture to escape into the sub-floor area, resulting in additional damage to the timber framework. To the extent that the claimed damage was caused by the leaking pipe, it is subject to cover under the policy. Case No: 384164 Determination Page 6 of 8 For the reasons outlined above, the Panel is satisfied that both the inadequate ventilation and the leaking pipe have materially contributed to the claimed damage. In the absence of sufficient information to determine the proportionate contribution of each of these factors, the Panel considers that it is fair in all the circumstances that the FSP and the Applicant bear the cost of repairing the claimed damage equally. 2.2 How should the claim be settled? Extent of damage and costs of repairs is unclear Under the terms of the Applicant’s policy, the FSP is required to settle a claim for building damage by repairing the damage or paying the Applicant the cost of repairing the damage (based on the most competitive quote received). The Applicant has provided a quote for $64,185 from her builder (H) for the necessary repairs to the kitchen, including the replacement of the concrete slab and floor tiles, repairs to the plasterboard and the replacement of damaged appliances. The FSP disputes the extent of the damage to t he Applicant’s kitchen caused by the moisture-affected timber flooring. Among other matters, the FSP disputes that 40% of the kitchen flooring requires replacement. The Panel notes that the quote provided by the Applicant appears to include repairs to the joinery in the laundry, in circumstances where it is not clear that this damage is related to the current claim. There is also insufficient information available to determine the extent to which appliances in the kitchen and/or laundry need to be replaced. In the circumstances, the Panel considers that the FSP should be required to engage an appropriately qualified expert (who has not been involved in the claim to date) to prepare a scope of works for the repair of the damage to the Applicant’s property ca used by the deterioration of the moisture-affected timber framework under the kitchen. Following receipt of the scope of works, the FSP is to obtain quotations from two suitably qualified builders (who are willing to conduct the repairs directly on behalf of the Applicant) for the cost of carrying out the repairs set out in the scope of works, together with an estimate of the likely timeframe for completion of the works and confirmation as to whether temporary accommodation will be required (and, if so, for how long). The Applicant may nominate one of the builders to provide a quotation. The FSP is to cash settle the Applicant for 50% of the sum of the more competitive quotation and the reasonable costs of temporary accommodation, to the extent required whi le the repairs are carried out. Reimbursement of professional costs Case No: 384164 Determination Page 7 of 8 The Applicant seeks reimbursement of costs incurred by her in engaging contractors to identify the cause of the damage. The policy provides that the FSP will pay for the reasonable costs of locating the source of a water leak. The FSP has previously agreed to reimburse the Applicant for $1,000 of costs incurred by the Applicant in locating the leaking pipe, subject to providing copies of relevant receipts. The Applicant engaged the services of various contractors (including a pest expert, a plumber and a builder) in order to identify the leaking pipe. Based on the information provided by the Applicant (including relevant receipts), the Panel is satisfied that she incurred costs of at least $1,000 in doing so. The Applicant also seeks reimbursement for fees of $1,650 paid to her engineer (VC) for the preparation of this report. Under paragraph 9.4 of the FOS Terms of Reference, FOS may require a financial services provider to contribute to legal or other professional costs incurred by an applicant in the course of their dispute. The Panel accepts that it was necessary for the Applicant to engage an engineer, in order to be able to effectively dispute the FSP’s denial of her claim, which wa s based primarily on the findings of its own engineer (DW). The Panel is satisfied that VC’s report has been of assistance in establishing that part of the claimed damage was caused by the leaking pipe. In these circumstances, the Panel considers that the FSP should be required to reimburse the Applicant for the costs of $1,650 incurred in obtaining VC’s report. Case No: 384164 Determination Page 8 of 8 3 Supporting information 3.1 FOS approach to this dispute This dispute has not been the subject of a FOS Recommendation. Due to the nature of the dispute, it has been referred directly to a Panel for Determination, in line with the Operational Guidelines to the FOS Terms of Reference. The Panel consists of an Ombudsman and two representatives with consumer and insurance experience. The Panel has decided this case on its merits, having regard to the relevant law, good industry practice, codes of practice and previous Financial Ombudsman Service (FOS) decisions. There has been a full exchange of all material information relied on for the purposes of this Determination and each party has had the opportunity to address any issues raised by the other. The Panel has reviewed and considered all of the material provided by the parties. While the parties have raised numerous issues in their submissions, for the purposes of this Determination, the Panel has restricted its commentary to those issues that it considers directly relevant to the outcome only. 3.2 Terms of policy Su bject Terms Insured event – escape of liquid Liquid escaping suddenly and unexpectedly from a :  water main, drain, fixed pipe … Escape of liquid – specific exclusions No Damage or loss resulting from:  liquid escaping slowly over a period of time where you could reasonably be expected to be aware of this condition … Ge neral exclusions You are not cover ed under any section of the policy for damage … caused by or arising from or involving:  wear and tear, rust, deterioration or corrosion,  structural … or other failure or breakdown,  mould, wet or dry rot, rising damp or dampness …

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.