Faulty paint rectification after burst pipe water damage repairs by insurer's authorised repairer
Summary
After a burst flexible pipe damaged the home, the insurer's authorised painter applied paint incorrectly and the insurer agreed to rectify it. AFCA required the insurer to strip and repaint the incorrectly painted surfaces and ceilings, supervise the works, and pay $1,000 for non-financial loss.
The insurer remains responsible for its authorised repairer's faulty workmanship and cannot rely on the policy's cash settlement option where the applicant does not agree to it.
Issues
- Repairs or contractors primary · upheld
“The FSP is required to rectify the paint work by removing all aqua trim gloss paint incorrectly applied and repainting in accordance with the Applicants' paint expert DP's advice.”
- Delay secondary · upheld
“The Applicant is entitled to compensation for the inconvenience suffered; the time taken to resolve this dispute is unacceptable.”
Subjects and remedies
home or building damagepay non financial lossrepair or rectify
Text of the determination
Determination
Case No: 378743 Determination Page 1 of 9
Case number : 378743 25 August 2015
1 Overview
1.1 Dispute
The Applicants lodged a claim on 19 March 2014 under their Home and Contents
policy following damage sustained to the property after a flexible pipe burst in an
upstairs bathroom.
The FSP accepted liability for the damage and arranged for the repairs to be
conducted.
The Applicants were dissatisfied with the quality of the repairs during the repair
process. The FSP accepted liability with respect to rectification of the repairs.
The Applicants dispute the rectification program offered by the FSP. The Applicants
seek that the FSP rectify the issues with the paint work by applying the paint in
accordance with the manufactur er’s instructions and supervise the rectification
program.
1.2 Issues and key findings
Is the FSP required to rectify the paint work?
The FSP is required to rectify the paint work by removing all aqua trim g loss paint
incorrectly applied and repainting in accordance with the Applicants’ paint expert
DP’s advice.
Is the FSP required to rectify the paint work to the ceilings?
The FSP is required to rectify the paint work to the ceilings by re-sanding the patched
surfaces and using a full coat of undercoat sealer to seal the reinstated ceiling plaster
board. The FSP is to then repaint the ceilings in accordance with the scope of works.
Is the FSP required to supervise the rectification work?
The FSP is required to supervise the rectification work by having its quality and
technical loss adjustor SB perform quality inspections at different stages of the
rectification process including the inspection of completed repairs to ensure the
Applicant’s satisfaction.
Case No: 378743 Determination Page 2 of 9
Is the Applicant entitled to compensation under paragraph 9.3 of the Terms of
Reference?
The Applicant is entitled to compensation under paragraphs 9.3 of the Terms of
Reference for the inconvenience suffered.
1.3 Determination
This Determination is in favour of the Applicant. The FSP is required to rectify the
incorrect paint work by:
removing all acrylic aqua trim gloss paint applied back to the enamel surface as
per the advice of the Applicant’s expert DP;
the FSP is entitled where appropriate to remove the skirtings and architraves
and repaint all new skirtings and architraves;
the FSP is entitled to remove and replace the robe doors as per the scope of
works provided by LB;
in the event the FSP is unable to remove the acrylic aqua trim gloss paint from
the other internal doors, then the FSP is to replace, prepare and repaint those
doors;
the FSP is to re-sand and apply a full coat of undercoat sealer to the ceilings to
ensure the proper sealing of the reinstated ceiling plasterboard and then to
repaint the ceilings;
the FSP is to supervise the rectification works by the appointment of SB to
inspect the start of the rectification process and the completed repairs at the
finish of each stage;
the FSP is to pay the Applicant the sum of $1,000 pursuant to paragraph 9.3 of
the Terms of Reference by way of compensation for non-financial loss.
Case No: 378743 Determination Page 3 of 9
2 Reasons for Determination
There has been a full exchange of material between the parties and each party has
had the opportunity to address the issues that arise from the material exchanged.
In addition, I have had the opportunity of discussing the issues with both parties.
I am satisfied following those discussions that the principle issues in dispute relate to
the rectification of the paint work and in particular:
the removal of the acrylic aqua trim gloss paint incorrectly applied by the
previous repairer SBG;
the repair and resealing of the reinstated ceiling plasterboard;
the supervision of the rectification repair process;
compensation for the inconvenience suffered as the result of the delays in the
repair process.
I am also satisfied following discussions with the parties, that the following issues are
not in dispute and do not need to be addressed in this Determination:
repairs to the timber floor. The FSP has agreed to replace the entire floor and
this is no longer in dispute;
possible sagging and bowing plaster in the rumpus and hallway. The FSP has
agreed that SG will inspect the area at the start of the rectification process. The
FSP has accepted that any issues with the plaster in the hallway and rumpus
room will be included in the rectification work if required.
This Determination follows consideration of all of the information exchanged and is
based on what is fair in all the circumstances having regard to the relevant legal
principles, good industry practice, industry codes, the terms of the policy and prior
Determinations where applicable.
2.1 Is the FSP required to remove the acrylic aqua trim gloss paint
incorrectly applied?
The FSP is required to remove the acrylic aqua trim gloss paint back to the enamel
surface.
There is no dispute between the parties that the acrylic aqua trim gloss paint was
incorrectly applied.
As a result of the application of the paint directly over satin enamel, issues arose with
the paint peeling from the skirtings, architraves, doors, door jams and other areas.
Those issues have continued.
The FSP has relied upon a Substrate Preparation G uide from the paint’s
manufacturer S that recommends any loose and flaking paint be removed from the
substrate, and that all gloss surfaces are completely dulled and wiped clean. The
FSP maintains that recoating in these circumstances is an entirely acceptable
method of repair.
Case No: 378743 Determination Page 4 of 9
The Applicant on the other hand has provided an email from a paint expert DP who
has advised that the application of the aqua trim gloss directly over satin enamel is
not recommended as typically it will not adhere properly. The non adherence was
demonstrated in photographs provided depicting the paint peeling from the skirtings
and architraves. There is no dispute that this has occurred.
I note the Substrate Preparation Guide makes reference to loose and flaking paint,
but does not deal with paint which is failing to adhere because it was incorrectly
applied in the first place.
It is not disputed that acrylic paint which was applied in error by SBG has already
come away from the enamel paint underneath, because it did not properly bond with
the underlying surface.
Based on the information exchanged, I accept that the only way to achieve a suitable
resolution of this dispute is to ensure that all of the acrylic aqua trim gloss paint
applied to the surfaces to be painted must be removed before any other paint is
applied. In my view, if this is not done, it is likely that any repainting will fail if and
when the incorrectly applied acrylic paint peels from the underlying surface.
For this reason, I believe it is appropriate that the FSP remove all acrylic aqua trim
gloss paint that has been applied as recommended by DP.
I note the FSP agreed to replace the skirtings and architraves to which the acrylic
paint was incorrectly applied by SBG. It says it chose this course of action for these
items because they have moulded features and are difficult to sand. I accept this is
reasonable.
The FSP says it does not need to replace the door jambs, window jambs and some
internal doors, because they are flat. They can easily sand the surfaces back. If
during the paint removal process any doors are damaged, it will replace those doors.
In my view, the FSP’s proposal is reasonable, providing the sanding of the flat
surface items achieves the goal of removing all the incorrectly applied acrylic paint at
least back to the pre-existing enamel surface.
Surface can then be prepared as specified in the Aqua Trim Gloss product
information sheet
The material provided by the Applicant indicates that once the incorrectly applied
acrylic paint is removed back to the pre-existing enamel surface, the surface needs
to be prepared according to the product information sheet for the Aqua Trim Gloss
paint.
That is, the FSP is to arrange for one coat of S Line 4311 Maxi Primer-Sealer-
Undercoat to be applied and left to dry for at least two hours, prior to the application
of two coats of the Aqua Trim Gloss.
This same treatment is required for any items which the FSP replaces, including the
skirtings and architraves.
Case No: 378743 Determination Page 5 of 9
2.2 Is the FSP required to undertake further works to the ceilings of the
Applicants’ home ?
The Applicant maintains that rather than apply the maxi sealing white paint directly to
the patched areas, the painting surface should have been properly prepared and an
appropriate undercoat sealer applied.
There is no dispute between the parties that SBG patched areas of the Applicants’
ceiling which were damaged, or that it applied Maxi Ceiling White paint
(manufactured by S) directly to the patched areas.
Sanding and undercoat sealer needed for patched surfaces
The product information sheet for S Line 4635 Maxi Ceiling White indicates that when
painting surfaces which have been previously painted with a flat or low sheen finish,
no further preparatory coats are required. However, if the surface has been
previously painted with a gloss or semi-gloss enamel, or if the surface has been
patched etc. the surface should be sanded smooth and a full coat of S Line 4592
Maxi Prep Acrylic Undercoat Sealer applied.
Again, the FSP maintains that the relevant Product Information Sheets states that for
plasterboard, satisfactory results can be obtained by applying two coats of the maxi
sealing white directly to the surface providing joints and patching are to be lightly
sanded and dusted completely.
Although acknowledging the product information sheet suggests that for best results
on plasterboard, one coat of undercoat sealer should be applied as a first coat, the
FSP maintains it does not specify that this is a requirement. It says that it performed
the work to industry standard and does not propose to perform any further work.
Original Scope of Works specified sealing of reinstated ceiling plasterboard
I note that the Scope of Works originally produced by “St” specified that the
reinstated plasterboard of the ceiling were to be sealed, prepared and repainted in
several affected rooms.
Further, I note that the quotation by LB for the rectification includes an entry for the
repainting of the downstairs ceiling.
It is therefore difficult for the FSP to argue that by applying the Maxi Ceiling White to
the downstairs ceiling, without first applying an undercoat-sealer, it correctly
performed the painting of the ceiling.
The FSP is therefore required to arrange for:
Apply one coat of the S line 4311 Primer-Sealer-Undercoat to the downstairs
ceiling, after preparing this previously painted surface in accordance with this
product’s data sheet (see section 3.1 )
Apply one coat of S Line 4636 Maxi Ceiling White to the downstairs ceiling.
Case No: 378743 Determination Page 6 of 9
2.3 Is the FSP required to supervise the rectification work?
The FSP’s offer with respect to the supervision of the rectification work is reasonable.
The Applicant believes the FSP should provide supervision and joint inspections of
the works at the start and finish at every stage.
In my view, the FSP’s offer to have its quality and technical loss adjustor SB inspect
all the work at the start of the rectification process and to inspect the completed
repairs to ensure the Applicant ’s satisfaction is reasonable.
I accept that this would be consistent with relevant industry standards.
I further note that the FSP retains responsibility for the workmanship performed by
both the original repairer SBG and the workmanship of LB in completing the
rectification works.
Is the Applicant entitled to compensation pursuant to paragraph 9.3 of the
Terms of Reference?
The Applicant is entitled to compensation pursuant to paragraph 9.3 of the Terms of
Reference as the Applicant has suffered an unusual degree of inconvenience and
time taken to resolve the issue.
The Terms of Reference provide the Service may award up to $3,000 by way of
compensation for non-financial loss where an Applicant has suffered an unusual
degree of time taken or loss of enjoyment of life during the resolution for claim.
The Applicant’s claim was lodged in March 2014. As a result of the faulty repairs, the
original repairer ceased work in or around September 2014.
I accept the FSP has acted appropriately and demonstrated its willingness to rectify
the problems caused by the previous repairer SBG. The FSP readily accepted that
the work performed by SBG was not at an acceptable standard.
The FSP has also responded to the Applicant’s claims with respect to the floor and
other aspects of the claim rectifying those issues.
Nevertheless, it is clear from the Applicant’s correspondence that the issues have
caused a degree of personal impact more than what you would expect in a normal
repair process. Whilst the Service expects an Applicant to be robust and that there
will be a level of inconvenience in any claim, in my view the time taken to resolve this
dispute is unacceptable.
In view of the issues that arise, I believe it is fair in the circumstances that the FSP
pay the Applicant the sum of $1,000 by way of compensation for non-financial loss
pursuant to paragraph 9.3 of the Terms of Reference.
Case No: 378743 Determination Page 7 of 9
2.4 Other Matters
FSP cannot opt for cash settlement
This dispute arises out of poor/faulty workmanship of its authorised repairer.
Accordingly, the FSP has a responsibility to rectify this damage and it is not able to
rely of the provisions of its policy to opt for a cash settlement in circumstances where
the Applicants do not agree to this.
Scope of work, storage and accommodation
The Applicants have indicated that they want a full scope of work from LB prior to the
commencement of repair work, so they can be assured that the work being
authorised deals with the rectification of the paintwork to their satisfaction. They also
wanted the quotation by LB to include reference to accommodation and storage of
contents. In response, the FSP in an email dated 27 April 2015 confirmed that once
the repairs have been authorised:
LB would send the Applicants a full scope of works with the contract to be
signed
The FSP requested for LB to arrange for the furniture removal and storage
The FSP will discuss the accommodation requirements with the Applicants
directly.
In my view, the FSP’s response in this regard is fair in all the circumstances.
Case No: 378743 Determination Page 8 of 9
3 Supporting information
3.1 Material referenced
Record Key points
Paint manufacturer
(S)
Maxi Ceiling White
Product Information Sheet
Revised Jan 2011
“Previously painted surface s
…
When painting surfaces which have been previously painted with a flat
or low sheen finish, no further preparatory coats are required.
However, if the surface has been previously painted with a gloss or
semi - gloss enamel, or if the surfac e has been patched etc. the surface
should be sanded smooth and a full coat of [S] Line 4592 Maxi Prep
Acrylic Undercoat Sealer applied.
…”
Paint manufacturer
(S)
Aqua Trim Gloss Product
Information Sheet
Revised Jan 2011
“ SURFACE PREPARATION:
…
Timber and Paper - Faced Plasterboard (Interior) - New or Previously
Painted:
Apply 1 coat of [S] Line 4311 Maxi PSU Primer - Sealer - Undercoat and allow at
least 2 hours to dry before applying 2 coats of [S] Line 4585 Aquatrim Gloss. ”
Paint manufacturer
(S)
Primer - Sealer - Undercoat
Line 4311 – Dat a Sheet
Oct 2013
“RECOMMENDED SUBSTRATE CONDITIONS & PREPARATION :
…
Previously Painted Surfaces :
Ensure that surfaces are clean and free from dirt, grease, dust, or loose or
friable matter. Remove loose and flaking paint and sand smooth. San d
previously painted enamel surfaces to remove gloss. Remove sanding dust.
Spot prime bare areas as recommended for new areas above. Chalky
surfaces such as kalsomine must be washed and rubbed down to a sound
surface. On areas where it is not possible to c ompletely remove chalky
materials, apply [S] Surface Conditioner (Line 4104) and allow to dry for 48
hours before applying [S] Maxi P.S.U Primer Sealer Undercoat (Line 4311) . ”
Applicants’ paint
expert
(DP)
Email
Undated
“...
As discussed yesterday, our specification for painting Aqua Trim over
previous enamel requires the use of an underc oat. Applying the Aqua
Trim directly over Satin Enamel is not rec ommended as typically it will
not adhere properly as per that shown in your phot ographs.
I have attached a copy of our specification sheet covering this
circumstance. The surface must be prepared in accordance with the
directions for the specified Primer - Sealer - Undercoat (refer attached
Technical Data).
The adhesion of Aqua Trim to a clean and sanded enamel surface may
improve over time if the surface was properly sanded and cleaned prior
to application, however, unless the work has been done in accordance
with the above specification we would not be able to provide any
guarantee or warranty of system performance. Given this, to ensure a
warrantable system, the existing acrylic coating must be removed back
to the previous enamel surface, then prepared correctly before the
specified system applied.”
Paint Manufacturer
(S)
Substra te Preparation
Guide
Undated
“SUBSTRATE: Timber – Internal
…
Substrate Preparation: All surfaces must be clean, sound, dust free
and dry or lightly damp….
On previously paint ed surfaces, remove loss and flaking paint and
wash down chalking surfaces. On su rfaces where it is not possible to
completely remove these materials apply [S] Line 4104 Surface
Conditioner and leave to dry for 48 hours. All Gloss Surfaces should be
Case No: 378743 Determination Page 9 of 9
dulled completely by sanding, then wiped clean with a damp cloth.
Spot prime bare areas with the finis hing coat
FSP’s Building
coordinator (St)
Scope of Works
11 April 2014
Bedroom 1 and 2, Hallway, Laundry, Rumpus/Pool Room
Painting
o (a) Reinstated plasterboard/FC
Ceiling – Seal, prepare and repaint to match existing
FSP’s builder (L)
Quote to repair damage
30 March 2015
Remove the skirtings and architraves from downstairs area
Remove robe doors and dispose of, keeping locks, hinges, etc
Remove the ent ranc e doors to bedroom and hallways and save for
reuse
Allow to supply and install new skirtings and architraves to the
downstairs area to match existing
Supply and install new robe doors
Reinstate the existing bedroom doors including all locks, hinges,
stops, etc.
…
Allow to prepare and paint new doors
Allow to prepare and repaint the existing bedroom doors
Allow to prepare and paint new skirtings and archit raves
Allow to remove and replace two air conditioning ducts that were
painted by the original contractor.
Repaint the ceiling in the downstairs area
…
Fin al Total $27,485
Please note : We have no allowance for the removal or storage or any
furniture. This is to be undertaken by [FSP].
Please note : The paint that is to be applied to this job is quality paint. It
will be applied in a tradesman like fashion and no responsibility will be
taken for the workmanship of the previous painter.
Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.