Home / Financial Firm (Unknown - Insurer) / Determination 378736

Determination 378736

Denial of home building damage claim relying on earth movement exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2015-06-11
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicant claimed under her home policy for damage from leaking sewerage pipes and settling patio slabs. AFCA found the FSP liable to rectify cracking and gaps on the right side of the home, but not the pipe repairs or the patio slab.

The leaking pipes were the proximate cause of the right-side damage and the write-back to the earth movement exclusion applied, while settlement of fill beneath the patio slab is not an insured event.

Issues

Subjects and remedies

home or building damagerepair or rectify

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of Claim Determination Case No: 378736 Determination Page 1 of 11 Case number : 378736 19 May 2015 1 Overview 1.1 Dispute The Applicant lodged an insurance claim for damage to her home caused by leaking pipes. The Financial Services Provider (FSP) denied the claim on the basis that:  the cracking damage to walls of the home near the toilet, bathroom and ensuite has been caused by heaving of the soil, which is excluded from cover under the policy  the movement of the patio slab is not due to an insured event under the policy. The Applicant wants her entitlements under her policy and says her engineer has recommended underpinning of the home. 1.2 Issues and key findings Is the FSP liable for the damage to the right hand side of the home? The FSP is liable for the damage to the right hand side of the home because:  the proximate cause of the damage is the leaking of sewerage drainage lines in that area of the building and leaking pipes is an insured event under the policy  the FSP is not able to rely of the policy exclusion for earth movement  the FSP is not liable, however, for rectification of the leaking pipes. Is the FSP liable for the movement to the rear patio slab? The FSP is not liable for the movement of the rear patio slab because:  the movement of the slab is caused by settlement of fill material upon which the slab is situated  settlement of soil is not an insured event under the policy. 1.3 Determination This Determination is partly in favour of the Applicant. After the Applicant has arranged for the repair of the leaking sewerage pipes identified in the report by her plumber (T) and the soil in the area is allowed to dry out for an appropriate amount of time, the FSP is required to rectify, under the terms and conditions of the policy:  any cracking damage that remains to the walls on the right side of the home Case No: 378736 Determination Page 2 of 11  any gaps beside the windows and doors that remain on the right hand side of the home. With respect to the amount of drying out time (as mentioned above) which would be considered appropriate, the FSP is required to seek guidance from an engineer. The FSP is not required to pay for the rectification of the movement to the rear patio slab. Case No: 378736 Determination Page 3 of 11 2 Reasons for Determination 2.1 Is the FSP liable for the damage to the right hand side of the home? Proximate cause of damage is the leaking of sewerage drainage lines The damage to the right hand side of the Applicant’s home is in the form of cracking damage to external brickwork and gaps adjoining window frames in the vicinity of the ensuite, the main bathroom and the toilet. The report from plumber T, confirms the presence of two leaks from sewerage pipes on the right hand side of the building, at the base of IOS under slab and foundations on:  main bathroom branch  ensuite bathroom branch. The engineer engaged by the FSP (J), notes that the damage to the right hand side of the home is a direct result of “the upward movement in the soil” and that this movement “has been caused by the leaking sewerage pipes”. It is therefore accepted that the proximate cause (that is, the effective, dominant or operative cause) of the damage to the right hand side of the building, is the leaking sewerage pipes. Accordingly, the policy provides coverage for this damage. Although J has indicated that the cracking damage and gaps beside the window opening is within acceptable tolerances, as prescribed in the relevant standard, it is damage nonetheless. However, the FSP is only required to attend to rectification of this damage after the pipework has been repaired (noting that the FSP is not responsible for this rectification - see heading below). This is because the report by J notes that the foundation levels should return to original levels to some extent as the soil dries out, after the pipework repairs are complete. FSP not liable for rectification of the leaking pipes The insured event of bursting or leaking pipes contains a specific exclusion for the repair or replacement of the pipe from which the liquid escaped. This means that while the FSP is liable for the damage which ultimately resulted from the leakage of liquid from the sewerage pipework, it is not liable for the repair of the breaks to this pipework, identified in the report by T. FSP not able to rely upon policy exclusion for earth movement The FSP has sought to rely on a general exclusion of the policy with respect to earth movement, to deny liability for the damage to the right hand side of the building. Case No: 378736 Determination Page 4 of 11 However, while there is no dispute that earth movement was the immediate cause of the damage, this earth movement was itself caused by the leaking sewerage pipes. The engineers J and R have provided conflicting information as to the type of effect the leaking pipework had on the soil, with J saying the soil “heaved” (upward movement) and R indicati ng it settled or subsided (downward movement). I note that J undertook a comprehensive laser level survey of the building foundations, whereas R appears to have relied upon level readings provided by underpinning contractor M (and there is no information as to how M obtained these level readings). Accordingly, I favour the findings of J in this regard and accept that the type of earth movement caused by the leaking pipework was “heave”. I also acknowledge that the policy exclusion for “ loss or damage …cause d by or as a result of… subsidence … or any other earth movement ” includes a write -back for damage resulting from subsidence, where this subsidence is caused by insured event 2 (bursting or leaking of pipes). However, t he absence of specific reference to “earth movement” within the write - back does not alter the finding that the proximate cause of the damage (and the immediate cause of the earth movement), was the insured event of the leaking pipes. Accordingly, I do not accept that the FSP can rely on the earth movement exclusion to deny its liability for the damage to the right side of the building. 2.2 Is the FSP liable for the movement to the rear patio slab? Movement of slab damage is caused by settlement The reports by J indicate that the concrete patio slab at the south end of the building has moved and that this is due to settlement of uncontrolled and unrestrained fill in the area. The report by R also concedes that this is possibly the cause of the movement of the south end portion of the buildings apron s lab around the building. R has also raised concern that the ground services in the area had not been fully investigated by way of pressure testing and that any discharge of effluent into and around the foundation system could cause loss of bearing of the foundations and settlements in the area. However:  according to the report by J, T verbally confirmed that apart from the main bathroom and ensuite bathroom drains (on the right side of the home) and pipe bend under the laundry tub (behind the garage), all other lines passed the pressure test  the points where leakage was detected by T are somewhat remote from the area of the movement of the patio slab Case No: 378736 Determination Page 5 of 11  the evidence presented by J confirms that the foundations at the rear of the building (adjacent to the slab which has moved) have remained relatively stable. I am therefore not persuaded that leakage from ground services affected the foundations of the building near to where the slab has moved away from the rear brick wall of the home. Accordingly, I accept that the cause of the movement of the patio slab is the gradual settlement of the uncontrolled and unrestrained fill material where the slab is situated, noting that the movement is likely to have accelerated in recent times, due to rainy periods following years of drought. Settlement is not an insured event under the policy It is an accepted principle of general insurance law that an insured bear the onus to establish, on the face of the facts, that they have suffered a loss caused by an event to which the policy responds. This is known as a prima facie claim. Once so established, the onus shifts to the insurer to prove the application of an exclusion if it wishes to deny its liability for the loss. In the case of the movement of the slab, the cause of the movement (damage) is accepted to be settlement of the fill material underneath. This movement is not covered under any of the policy’s insured events and therefore the Applicant has not established a prima facie claim. Accordingly, the FSP has no liability for the movement of the Applicant’s rear patio slab. Case No: 378736 Determination Page 6 of 11 3 Supporting information 3.1 Other matters The Applicant has submitted that her engineer (R) and underpinning contractor M, have both recommended the underpinning of her home, whereas the FSP’s engineer (J) says that underpinning is not required. The Applicant says she is confused about the correct solution for fixing her home, given the conflicting opinions of the various professionals who have inspected and reported on the issues. The Determination is limited to the issue of whether the FSP is liable, under the terms and conditions of its policy, for the damage claimed. In this dispute, the FSP has been found liable for some of the claimed damage and not liable for other aspects of claimed damage. However, it is beyond the scope of this Determination to recommend any particular repair method for the rectification of damage which has been found to be not covered under the policy (that is, the movement of the slab). Further, based on the evidence presented, there does not appear to be damage to the foundations at the rear of the building, so no claim under the policy arises in this regard. Any remaining concerns the Applicant may have as to whether underpinning of the home is needed, cannot be addressed by this Determination. 3.2 Policy provisions What you are covered for … Insured events 1 to 12 When covered under this policy, your home and contents are insured for loss or damage at the insured address by any of the 12 insured events, if they happen in the period of insurance. … 2. Burst pipes, leaks and overflows … Complete details for thi s cover We cover Damage from leaking, overflowing or bursting pipes and water containers at the home including: – dishwashers and washing machines – roof gutters and rainwater downpipes, drainage and sewerage systems … Exploratory costs We will cover the reasonable cost of searching for the unknown cause of leaking pipes and restoring the damage we do to your home, but only if the leaking liquid is causing permanent damage to your home or contents. … We do not cover … Case No: 378736 Determination Page 7 of 11 – fixing or finding leaks that have not caused permanent damage to your home or contents (eg. a pipe leaking water over a outdoor pathway) – repair or replacement of the tank, pipe or container that wat er or liquid escaped from (eg. we will not pay for replacing a hot water system that leaks) … What you are not covered for This section details what is not covered under any part of your policy. … We do not cover loss or damage: … Erosi on or subsidence Caus ed by or as a result of erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage or any other earth movement but we will cover subsidence damage to your home if it is caused by: – insured event 2 (burst pipes, leaks and overflows) … 3.3 Expert evidence referenced Record Key points FSP’s expert (J) Report 21 August 2013  Problem - movement in external paths/slabs at rear .  Larger patio floor slab has migrated away from face of brick wa ll at rear of house – up to 20mm at rear left and right corners of building (13 mm in the middle of building) .  Laser level survey (partial – only to rear of house) clearly indicated no significant movement in foundations system of house. Only a variation of +/ - 10mm over entire back half of building.  Survey measurements confirm foundation system founded into solid bearing ground and is not relying on fill material to support weight of building .  Back edge of rear patio concrete slab is almost at rear boundary. Timber fence along this back boundary has failed in one large section towards L/H corner of property – this has highlighted height of fill material along back section of property (as well as at back of adjoining properties).  Movement of large patio slabs away from house’s brick wall appears to have been long term problem – with gaps slowly increasing for many years .  Movement may have been slower during 10y drought up un til a couple of years ago . When drought broke, constant flooding rain each year would have accelerated compaction/settlement of fill soil at rear of property. In absence of retaining restraint the fill has migrated slowly down face of terraced bank behind property.  Concrete path on L/H side is in basically same position as when poured in. However c oncrete path on R/H side has cracked and mov ed for level place with rear patio floor slab, and dramatically separate from rear R/H corner of building. Crack/separation and stepping out - of - level of path is in same location as connection to underground stormwater drain (at base of downpipe) . Case No: 378736 Determination Page 8 of 11  Applicant advised drainage system has been inspected by plumber with drain camera and found to be in good serviceable condition in rear R/H corner of house. Stormwater line toward front R/H corner of house found to have blocking tree root matter – but rear R/H corn er connection remained intact and unblocked.  Evidence suggests movement of path has also been a long term issue . Applicant’s engineer (R) Report 5 Feb 2014 (A report dated 14 Mar 2014 was also produced which largely repeated the same information)  Dwelling has not experienced problems for 15 - 18 years but is now showing settlement strain of south and west end. This is evidence in sheer crack in centre of west all at or about toilet/bathroom window (sheer of bed and perpend of the bricks from “DCP” to windowsill).  In same area as crack are “DPDs” and “ORGs” and stacks indicating external plumbing, returning to the rear of building which has similar plumbing fittings. This indicates the south & west side is traversed by ground services.  Rainwater downpi pes located in N/W corner and S/W corners .  Major defect is settlement of brick veneer wall, particularly in the south end – brick courses are approx 50mm out of level from front N/W bedroom wall to rear master bedroom and lounge/dining room.  Other defects include opening of jambs at brick reveals of windows and sliding doors on south and west sides.  Archway separation in lounge/dining room – cornice on kitchen dining side has recess in top surface, indicating trusses are seating down onto the ceiling and t he gap required by slider clips on load bearing walls is now void.  Indication that transom truss has also settled and leaning on area of dining room west wall.  Dwelling has apron slab all around and has a (coloured, sic) portico open area on south end (4.5 m - 5m wide). This apron has moved – suggesting possible normal settlement of uncontrolled fill in this area.  However, in - ground service in this area have not been properly investigated/pressure tested to indicate if there is leakage/discharge of effluent in to and around foundation system (giving rise to reduction in bearing of foundation material & settlements). Recommend full drain cam and pressure test be done.  Also recommend geotechnical test of a “DPC” to indicate strength of material at depth of future underpinning. Applicant’s plumber ( T ) Undated report (inspection 13 Feb 2014)  All underslab drains pressure tested and some sections of drain inspected by drain camera. Drains accessed via IOS on R/H side of property. The [following] drain[s] failed test: o Base of IOS under slab and foundation on main bathroom branch (R/H side of house) o Base of IOS under slab and foundation on ensuite bathroom branch (mid - R/H side of house) Case No: 378736 Determination Page 9 of 11 o 90 degree bend under slab under laundry tub (L/H side of house behind garage)  All other underslab and main drain held test . (Trenchless repair can be used to reline breaks found - $3,300 . )  Stormwater drains pressure tested and some sections inspected by drain camera – accessed through downpipe branch drains.  Stormwater drain at fro nt R/H corner of house is broken and failed the test – will be significant source of underground moisture.  Water supply passed testing. Applicant’s engineer (R) Report 14 Mar 2014  Report by T clearly indicates the 90 degree bend from laundry on west side of dwelling failed test and stormwater from front N/W corner also failed.  As sewerage lines are imbedded in sand, any water discharging from fractures would be directed adjacent to foundations to the building, not only at area of bathroom laundry but righ t across south side of dwelling (as line also traverses across full south boundary). This is evident by levels taken by underpinning contractor (M) which show settlement in “this corner” of 50mm. FSP’s expert ( J ) Reinspection Report 16 Apr 2014  Report by T noted pressure testing of sewer drainage lines and breaks areas tested into 3 locations . Discussions with T confirmed all thr ee locations listed failed test .  Remainder of lines passed pressure test – apparently including branch line from kitchen sink at back wall of house in same area as severe movement of rear patio slab.  Sewer drainage system has fractures and breaks down R/H side as well as in rear L/H corner of house (laundry) .  All 3 area s of failed drainage are remote from back wall of house where patio slab has moved away from brick wall, whereas the 1 drainage line from kitchen was serviceable .  Report by T also notes the only stormwater drain which failed test was the broken front R/H corner downpipe (stormwater drains at rear of house in good co ndition) .  Mains supply tested but no faults found.  Report by R state 50mm fall or settlement starting at N/W front bedroom and falling to rear main bedroom/dining room. However Applicant said when asked that she did not see R measuring or using level equip ment. (Other report by R notes that 50mm measurement source from underpinning contractor but no indication R confirmed these measurements . )  R notes separation in an a r ch in lounge/dining room but Applicant confirmed she did not have any arches in internal plaster walls (just 1 opening from front dining/lounge to rear family/breakfast room ). Inspection of plasterwork in area of this opening by J showed no separation or movement in plasterboard as suggested by R.  2 nd report by R suggests everything should be underpinned Case No: 378736 Determination Page 10 of 11 due to movement in 2 different parts of building (rear patio slab, and brickwork on R/H side). However prelim investigation (by J) in to patio slab movement involved accurate readings of foundation levels across rear of house – these readings d id not show any gross foundation movement in this part of house.  Extensive level readings undertaken around perimeter of entire house and internally, during r einspection .  Results of external laser level survey and internal hydraulic level survey confirmed initial findings – house foundation remain relatively level from front to back and side to side (within 10mm - 12mm).  The only discrepancies were at front R/H corner of garage (higher by another 10mm) and R/H side wall incorporating toilet, bathroom and ensuite (foundation slightly higher by 20 - 30mm) .  Higher foundation (heaving) along R/H side wall attributed to 2 leaks in sewer drains. Level of foundations on R/H side show s low influx of water from ensuite drain leak has caused reactive soil to heave, not settle as suggested by R.  Also believed that cracks along R/H side wall and gaps against adjoining window frame are direct result of upward movement of soil , caused by leaking sewer pipes, as this area is constructed on natural ground not filled ground.  Foundation level under laundry and back of garage remain consistent with foundation levels across back and front of house (no abnormal heave in founding soil near broken laundry pipe bend) .  Foundation levels are within Australian Standards (AS2870) guidelines. Also cracked brickwork and gaps besi de window openings are within acceptable tolerances .  Rectification of leaking sewer pipes is recommended and the upward movement of foundations in that area should be monitored over time, as some return to original level may occur as soil dries out.  Internal floor slab levels confirm foundations along rear section of house are approx. 23mm - 29mm lower than rest of house floor. A small localised hump (16mm at max) observed in floor was main t oilet, bathroom and ensuite towards side wall .  20mm+ drop in level of concrete floor slab at rear of house has probably caused “bumps” in plaster cornice in dividing partition between family/breakfast and lounge/dining rooms.  Roof trusses have also settled with this movement, causing distinctive “bumps” along top edge of cornices – but not of structural significance and can be addressed by redecorating/painting of walls and ceilings in this area.  Remainder of plasterboard linings are in good condition – no stress cracking or movement associated with gross foundation movement . ( Similarly, there is evidence of cracking, sheering or separation in ceramic floor tiles ) . Case No: 378736 Determination Page 11 of 11  Internal floor levels are within acceptable guidelines in Australian Standard for foundations and floor slabs.  Underpinning of rear half of building is not recommended (by J) at this time as this may caused structural damage in the process .  Cosmetic repairs to cracked brickwork and to gaps beside window and door frames are all that is recommended a t this point (and as it can be attributed to ground movement caused by escape of water from broken pipe ) .

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.