Home / Financial Firm (Unknown - Insurer) / Determination 377528

Determination 377528

Denial of home claim - earth movement exclusion

FirmFinancial Firm (Unknown - Insurer)
Decided2015-03-20
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss$500
Amount claimed—
SourceAFCA PDF

Summary

The Applicants claimed for cracking and door-jamming damage to their home. The FSP denied the claim under the earth movement exclusion, and AFCA upheld the denial but ordered $500 for non-financial loss caused by the FSP's inadequate investigation of their leak complaint.

The evidence established the damage resulted from earth movement, which is excluded, but the FSP's reliance on an unverified plumber's report without proper investigation caused an unusual degree of stress.

Issues

Subjects and remedies

elderly or capacitypay non financial loss

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of claim Determination Case No: 377528 Determination Page 1 of 6 Case number : 377528 4 March 2015 1 Overview 1.1 Dispute The dispute relates to a claim the Applicants lodged on their home insurance policy with the Financial Services Provider (FSP). The claim was for recent damage including cracks in the plasterboard ceilings and walls, and doors jamming in the Applicants‟ home. The FSP denied the claim on the basis the policy does not cover earth movement, howsoever caused. 1.2 Issues and key findings Is the FSP entitled to deny the Applicants’ claim? The FSP is entitled to deny the Applicants‟ claim because:  the home has been affected by earth movement  earth movement is excluded from cover  the evidence establishes the damage resulted from earth movement. Are the Applicants entitled to compensation for non-financial loss? The Applicants are entitled to compensation for non-financial loss because they suffered an unusual degree of stress from the FSP‟s failure to properly investigate their complaint regarding the FSP‟s plumber‟s report. 1.3 Determination This Determination is partly in favour of the Applicants. The FSP is entitled to deny the claim, however the FSP is required to pay the Applicants $500 for non-financial loss. Case No: 377528 Determination Page 2 of 6 2 Reasons for Determination 2.1 The FOS Approach I have decided this case on its merits, doing what is fair in all the circumstances and having regard to the relevant law, good industry practice, codes of practice and previous FOS decisions. I have taken into account all material submitted by the parties. I am satisfied that the documentation I have relied on has been provided to both parties and each party has had the opportunity to address any issues raised by the other. This dispute was expedited to a Determination. No Recommendation was issued. 2.2 Is the FSP entitled t o deny the Applicants’ claim ? The policy covers damage caused by leaks subject to exclusions The policy provides cover for loss or damage caused by defined events, including leaks. Cover is provided for loss or damage to the Applicants‟ home caused by leaks from pipes and drains fixed or connected to the home. However, such damage is excluded if the damage is caused by, or which arises in connection with, earth movement, howsoever caused. The Applicants have established the damage is caused by an insured event The Applicants must establish, on the balance of probabilities, they suffered a loss caused by an event covered under the policy. The Applicants obtained their own detailed plumber‟s (D) report demonstrating the stormwater and sewerage pipes were defective in various locations under the property resulting in leaks. While the FSP‟s plumber (L) did not find any leaks, the FSP has accepted D‟s report. The FSP‟s engineer (H) noted that the added moisture to the ground from leaks would reduce its load bearing capacity and result in the damage caused. Extracts from the reports are set out in section 3.2 below. The Applicants have therefore established the damage is caused by an insured event. As the FSP seeks to deny the claim, the onus shifts to the FSP to establish, on the balance of probabilities, the policy excludes the claimed damage. Case No: 377528 Determination Page 3 of 6 The FSP has established the damage is caused from earth movement The FSP relies on the exclusion titled “Erosion and landslide” which excludes loss or damage to the home which is caused by or arises in connection with earth movement no matter how it is caused. To support this argument, the FSP refers to H‟s report whic h included the following: “ Should they have fractured services, that this would then mean that the movement in the partitioning being load bearing partitions under transom trusses that his would then mean that the settlement and cracking of the ceiling is due to this movement. This movement would be because the bearing to the ground has been altered by the addition of moisture so reducing the capacity of this soil to support the applied load. Note also that doors do not open and shut and these are all in wet areas. Given this it would be evident that the settlement is occurring in these areas due to the wet occupation and usage of these areas giving an indication of water release. … CONCLUSION This firm is of the opinion that the settlement in this building is due to a fractured service and this should be investigated and reported by a qualified plumber… Should the pipes not be fractured and damage allowing water to penetrate in and under and be encapsulated in the footprint of this dwelling slab so reducing the foundation being pressure giving cause to differential settlement then the movement would alternately be classified as ground movement for which the policy will not respond. [sic] While the report is not as clear as it could be, it states the moisture in the soil has reduced the soil‟s load bearing capacity resulting in the building settling into the soil. The only way this can occur is for the earth itself to settle. The exclusion applies therefore applies and the FSP is entitled to deny the claim. 2.3 Are the Applicants entitled to compensation for non-financial loss? The Applicants have established an unusual degree of stress Under the FOS Terms of Reference, FOS may award up to $3,000 where there is an unusual degree of interference with the Applicant‟s expectation of enjoyment or peace of mind. The Applicants say they have suffered an unusual degree of stress as a result of L‟s report, which they say is false. Case No: 377528 Determination Page 4 of 6 To this end the Applicants noted that L:  was at their property for an hour  did not unload any equipment necessary to conduct pressure tests or camera views of the pipes  conducted a visual inspection only, and  provided a bare report merely stating that the pipes passed and there were no plumbing issues at the time. In contrast, D:  spent two days at their house  had to dig holes in their yard and remove the toilet basin to access the pipes, and  provided a detailed report including photographs of the pipes. The Applicants provided photos of D working on their site to demonstrate the degree of work required to investigate their pipes. The Applicants state the FSP did not properly investigate their complaint in respect of L‟s report, only seeking confirmation from the plumber and repeating its reliance on L‟s report. This is despite the Applicants providing a detailed basis to the FSP of why they considered L did not undertake the relevant plumbing tests. While it is unnecessary for me to make any finding as to whether L did complete the tasks he alleged, I do accept that it would have been prudent for the FSP to conduct further enquiries into L‟s investigative process given the nature of the Applicants‟ complaint. It was not until the Applicants engaged and pa id for their own plumber that the FSP accepted there was a leak. The Applicants, who are in their eighties, have suffered an unusual degree of stress as a result of the FSP‟s reliance on L‟s report without proper investigation. It is fair in all the circumstances for the FSP to pay the Applicants $500 for non- financial loss. 3 Supporting information 3.1 Relevant policy extracts “ Leaks Leaks are liquids that are leaking, bursting, discharging or overflowing from certain items or devic es. For example, the hose in your dishwasher bursts and water damages your kitchen cupboards and floors. We may also cover some other costs under the extra benefit „Investigating leaks‟ – see page 35. Yes ✔ The following items or devices malfunction at or near your home and leaks from them cause loss or damage to your home or contents: • dish and clothes washing machines • water catchment trays in refrigerators, freezers and evaporative air conditioners • waterbeds • pipes, gutters and drains which are fixed or connected to your home Case No: 377528 Determination Page 5 of 6 • fixed domestic items which include water tanks, lavatory cisterns and pans, baths, basins and sinks • water mains. No … ✘ The general exclusions shown on pages 55 - 57. ” “ General exclusions What we don’t cover This section outlines the general things we don‟t cover under your policy. They are known as general exclusions. Specific exclusions also apply to certain parts of your cover. Those specific exclusions are shown in the section „Your cover‟ under any relevant event or benefit that is outlined on pages 17 -54. Also, we don‟t cover certain items as part of your home or contents which are listed on pages 11 and 14. General exclusions These general exclusions apply to all of the cover we provide under your policy. We don’t cover you under your policy for loss or damage to your home or contents or legal liability which is caused by or ari se s in connection with any of the following items or events: Erosi on and landslide ✘ Erosion, landslide, subsidence, vibration, earth shrink age or expansion or any other earth movement no matter how it is caused (but we do cover earth quake and we cover some landslide or subsidence that happens within 72 hours of the first loss or damage to your home or contents caused by the flood or water runoff – see page 20). 3.2 Damage reported Record Key points FSP’s engineer ( H ) Engineering Report 27 March 2014  Did visual inspection and notice cracking of gyprock walling, cornices and doorways out of alignment.  Minor settlement of approximately five to six millimetres at the south - east end in line with the refrigerator and the arch opening f rom the formal dining room to the passageway.  Slight dip of approximately five to six millimetres in the area of the bathroom window brickwork.  There is minor movement in the trusses of the roof.  There is movement surrounding the sewerage of the building t owards the west/south and east elevations.  There is a high probability water is released from plumbing, affecting the building support under the building.  Recommended a qualified plumber undertake a drain cam and pressure test of the sanitary and stormwate r pipes.  If there are fractured drainpipes, then movement would be due to additional moisture in the soil, and settlement and cracking would be due to this movement.  Movement has occurred in the last six months to a year. Case No: 377528 Determination Page 6 of 6 Record Key points  If there are no fractured pipes th en the damage would alternatively be due to ground movement. FSP’s plumber (L) Leak Detection Report 6 June 2014  Attended property on 11 April 2014.  Results for a pressure test, CCTV inspection tests for sewer drainage and stormwater drain all passed.  Moisture test result was low.  No plumbing issues at the time of testing.  The cracking of plaster walls and ceilings throughout the home is most likely due to poor falls around the footprint of the building with stormwater building up around the edge of th e structure. Applicants’ plumber (D ) Plumbing and Drainage Report Undated  Inspected property on 10 and 18 September 2014.  Mains pressure test showed no underground leak.  CCTV drain camera inspection showed defects in the stormwater.  Recommended replaceme nt of all defective stormwater pipes.  Photographs provided showing breaks in the bends of the stormwater pipes, some bad joins and a squashed pipe.  Hydrostatic and CCTV drain camera inspection showed failed sewer pipes.  Photographs provided showing breaks in drains.  Recommended excavating and repairing the breaks by installing approved expansion joints.  Recommended a further retesting and inspection of the plumbing and drainage after recommended repairs. Applicants’ plumber (D ) Tax Invoice 25 September 2014  $2,255 for plumbing and drainage inspection and report.  The FSP reimbursed the Applicants for this cost.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.