Home / Financial Firm (Unknown - Insurer) / Determination 377306

Determination 377306

Claim denial - escape of liquid claim and exclusions

FirmFinancial Firm (Unknown - Insurer)
Decided2015-03-03
ProductGeneral Insurance · Home building and contents
OutcomeFor the complainant in part
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

The applicants claimed for bathroom and sub-floor damage from a leaking sewer pipe, which the FSP denied under earth movement and construction exclusions. AFCA found the leak was the proximate cause, so the FSP must indemnify the loss less a 20% pre-existing damage share, but the pipe replacement cost is excluded.

Escape of liquid is the proximate cause where the FSP cannot establish that an excluded factor such as earth movement or faulty construction was the dominant cause of the damage.

Issues

Subjects and remedies

home or building damagepay claimpay interestrepair or rectify

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Home Building - FSP Decision - Denial of Claim Determination Case No: 377306 Determination Page 1 of 8 Case number : 377306 2 7 February 2015 1 Overview 1.1 Dispute In May 2014, the Applicants lodged a claim under their home insurance policy with the Financial Services Provider (FSP) for damage caused to their main bathroom and the sub-floor underneath. The Applicants say the damage was caused by a leaking sewer pipe. The FSP denied the claim on the basis that the damage was not caused by the leaking sewer pipe but by a combination of earth movement and the faulty design and construction of the bathroom floor, each of which is excluded from cover under the policy. 1.2 Issues and key findings Is the FSP liable for the claimed damage? The Applicants have established a prima facie claim under the policy for damage caused by the escape of liquid from the leaking sewer pipe. The available information does not establish that the damage to the bathroom was caused by factors which are excluded under the policy. Accordingly, the FSP is liable for the damage caused by the leaking pipe. How should the claim be settled? The FSP is required to indemnify the Applicants for the damage caused by the leaking pipe (including the resulting damage caused by the sinking of the floor, which compromised the waterproofing membrane). However, the FSP is not liable for the pre-existing damage to the property and therefore the Applicants are to bear 20% of the costs of repairing the damage to the bathroom and the sub-floor. 1.3 Determination This Determination is substantially in favour of the Applicants. The FSP is required to indemnify the Applicants for the claimed damage in accordance with the terms of the policy and the process set out in section 2.2 below, provided that the Applicants are to bear 20% of the total costs of repairing the damage. To the extent that the claim is cash settled, the FSP is to pay interest on the settlement amount in accordance with section 2.2 below. Case No: 377306 Determination Page 2 of 8 2 Reasons for Determination 2.1 Is the FSP liable for the damage to the Applicants’ bathroom? Applicants have established a prima facie claim for escape of liquid The Applicants are required to show that, on the balance of probabilities, they have suffered a loss caused by a risk insured against under the policy. This is known as a prima facie claim. If the Applicants are able to establish a prima facie claim, then the onus shifts to the FSP to show that, on the balance of probabilities, it is entitled to rely on an exclusion under the policy to deny the claim. The Applicants’ policy provides cover for damage to their property caused by the insured events listed in the policy (including the escape of liquid from a pipe), subject to the conditions and exclusions set out in the policy. The cover provided for damage caused by the escape of liquid extends to circumstances where the liquid escapes slowly over a period of time (as in the case of a leaking pipe), provided that the insured could not reasonably have known that the liquid was escaping. The Applicants say that the damage to their bathroom was caused by a leak in the sewer pipe connected to the toilet, which led to extensive moisture enteri ng the sub-floor soils. They say that this caused the timber stumps to move, resulting in the subsidence of the tiled floor and the cracking and other damage observed at the property. When the Applicants lodged their claim in May 2014, they advised the FSP that several weeks earlier they had noticed that the bathroom floor was sinking and there was a strong smell of sewerage. The plumber (LP) appointed by the FSP to attend the property in May 2014 confirmed that the sewer pipe from the toilet was leaking. LP concluded that the liquid from the leaking pipe had saturated the soil under the house, which had caused the footings and piers to sink, resulting in the bathroom floor sinking. LP noted that the sinking of the floor had in turn damaged the waterproof membrane in the bathroom, which allowed water to enter the sub-floor when the shower was used, causing further subsidence. In these circumstances, I am satisfied that the Applicants have established a prima facie claim under the policy for damage caused by the insured event of escape of liquid. While the damage may have occurred gradually over a period of time, the Applicants could not reasonably be expected to have been aware of the leak, given the location of the pipe. Case No: 377306 Determination Page 3 of 8 FSP is liable unless it can show an exclusion applies Given the Applicants have established a prima facie claim, the FSP is required to show that, on the balance of probabilities, it is entitled to rely on a policy exclusion to deny their claim. In order to establish an exclusion applies, the FSP must show that the proximate cause of the damage to the Applicants’ bathroom (that is, the real, effective or dominant cause) was one or more factors which are excluded under the policy. The FSP says that it is not liable for the Applicants’ claim because the damage to the bathroom was not caused by the leaking pipe, but by a combination of the inadequate design and construction of the bathroom floor and the effects of naturally occurring earth movement, each of which is excluded under the policy. FSP’s contractors have provided inconsistent views In support of its position, the FSP relies on a report prepared by its engineer (C) who inspected the Applicant’s property in July 2014. In his report, C concluded that:  the bathroom floor had been built using a concrete slab supported by timber stumps, which were structurally inadequate to support the slab and relied on the weight of the slab to hold them in place;  as a result, and due to the reactive nature of the foundation soils, the stumps were prone to movement which had caused the slab to deflect; and  the deflection of the slab had damaged the water proofing system, allowing water to escape from the shower recess and enter the sub - floor area. This had caused the timber bearers and joists to decay. C considered that the damage had been occurring over an extended period of time (more than five years), due to the extent of the decay to the timber bearers and the severe corrosion of the corrugated iron under the concrete slab. He also noted evidence of past repairs to previous cracking and movement damage, including packing of the timber stumps under the bathroom and sealing of internal and external cracks. In its submissions to FOS, the FSP says that the “general expert consensus” is that the damage was caused by a combination of earth movement and faulty construction. However, while the views expressed by the FSP’s other contractors are consistent with C’s observations about the nature of the damage, their conclusions in relation to the proximate cause of the damage differ in several significant respects. In particular, I note that:  as outlined above, the plumber (LP) appointed by the FSP in May 2014 concluded that the proximate cause of the damage was the leaking sewer pipe (which he considered was the underlying cause of the movement of the stumps and the resulting damage to the waterproofing membrane);  while the engineer (WB) appointed by the FSP in June 2014 expressed concerns about the manner in which the bathroom floor had bee n constructed, he also noted evidence of moisture leakage around the sewer pipe. WB did Case No: 377306 Determination Page 4 of 8 not express a clear opinion as to which factor was the underlying cause of the damage; and  after reviewing the reports provided by LP and WB, the FSP’s building consult ant (AB) concluded that the damage had been caused by “a combination of” the subsiding slab and the leaking sewer pipe, which had allowed water to pond under the bathroom . He also stated that the dama ge had been present for only two to three months, which is inconsistent with it having occurred over an extended period of time as identified by C. Available information suggests damage occurred relatively recently In my view, the available information does not support the conclusions of the FSP’s engineer (C) that the damage to the bathroom occurred over an extended period of time due to the effects of naturally occurring earth movement on the poorly constructed bathroom floor. The pre-purchase inspection report obtained by the Applicants in January 2013 did not note any significant damage to the bathroom. With the exception of some minor cracking to the cornice line, the bathroom was described as being in an “ acceptable ” condition (meaning that it was of a sufficient standard to not require any remedial or repair work). The pre-purchase inspection report also described the sub-floor as being in an acceptable condition. This report includes a photograph of the sub-floor area under the bathroom, which confirms that the inspector gained access to the sub - floor for the purposes of the inspection. While the pre-purchase report notes evidence of water staining and damage to the subfloor area under the bathroom, this is referred to as “old” damage. The report does not identify extensive decay of the timber bearers, as observed by the FSP’s engineer (C) in August 2014. The pre-purchase report also confirms that the sub-floor was dry at the time of the inspection and no leaks were identified, which suggests that there were no current and ongoing issues with the bathroom at that time (particularly if, as the Applicants suggest, the previous owners were still occupying the property). The reports prepared by the FSP’s contractors indicate that, by May 2014, the damage to the bathroom was significant, with the floor having s ubsided by up to 13 millimetres and major cracking apparent to the bathroom and shower area. Given the extent of the damage to the bathroom and the relatively short time within which it appears to have developed, it is more likely that the damage was caused by a specific event (such as the leaking sewer pipe), rather than by construction and movement issues (which presumably would have been present throughout the life of the property and would have become apparent over a period of years rather than months). The Applicants say that they moved into the house in August 2013 and did not experience any issues until April 2014, when they noticed the bathroom floor sinking and a smell of sewerage, following which they lodged their claim. This is Case No: 377306 Determination Page 5 of 8 also consistent with the damage having occurred within a relatively short space of time (as is AB’s estimate that the damage did not commence until early 2014). Available information does not establish exclusion applies Based on the available information, I am not satisfied that the FSP has established that, on the balance of probabilities, the proximate cause of the bulk of the claimed damage to the bathroom was earth movement and/or construction defects (and not the leaking sewer pipe). The nature and timing of the damage is more consistent with it having occurred as the result of a specific event (being the leaking sewer pipe identified in May 2014), rather than as a result of ongoing factors affecting the property over an extended period of time. While the FSP’s engineers (C and WB) concluded that the concrete slab bathroom floor was not properly supported or reinforced, neither engineer has provided any specific information which establishes that the construction methods adopted did not comply with applicable building requirements at the time of construction. While C considered the potential impact of the leaking sewer pipe and dismissed it as minor, C’s report does not pr ovide any further explanation as to the basis on which he reached this view - for example, whether it was based on the volume of liquid which would have escaped from the pipe or the manner in which the escaping liquid wold have affected the surrounding soils. As noted above, the other contractors engaged by the FSP (including the engineer, WB) gave significantly more weight to the likely effects of the leaking sewer pipe. 2.2 How should the claim be settled? FSP is required to indemnify Applicants for damage caused by leaking pipe For the reasons outlined above, the FSP is not entitled to rely on either of the policy exclusions referred to, in order to deny the Applicants’ claim. Accordingly, the FSP is liable to indemnify the Applicants for the damage to their property caused by the leaking pipe. The reports prepared by the various contractors confirm that the further damage to the sub-floor caused by water leaking through the shower arose as a consequence of the damage to the waterproofing membrane caused by the initial subsidence of the floor. Accordingly, this damage is also attributable to the leaking pipe. However, it is apparent that the Applicants’ property was also subject to pre- existing and ongoing earth movement, which resulted in the minor cracking and movement damage identified in the pre-purchase inspection report and the reports prepared by the FSP’s contractors. The pre -purchase inspection report also identified pre-existing damage to the corrugated iron slab support and the timber joists and bearers of the sub-floor in the bathroom area. Case No: 377306 Determination Page 6 of 8 The Applicants’ policy provides that the FSP will settle a building claim by, at its election, repairing the damaged property to the same standard, specification or quality as when new or paying the Applicants the cost (to the FSP) of doing so. Accordingly, the FSP is to arrange for a scope of works and quotation for the repair of the claimed damage to be provided by a suitably qualified and experienced contractor, following which the FSP is to arrange for the repair of the damage or cash settle the Applicants for the amount of the quotation. Having regard to the extent of the pre-existing damage, I consider that it is fair in all the circumstances that the Applicants bear 20% of the total cost of the repairs. To the extent that the claim is cash settled, the FSP is to pay interes t on the settlement amount at the rate calculated in accordance with section 57 of the Insurance Contracts Act 1984 (Cth), from 26 September 2014 until the payment date. The FSP is not liable for the costs of $5,388.30 incurred by the Applicants in replacing the broken sewer pipe. The insured event of escape of liquid specifically excludes cover for the cost of repairing or replacing the pipe from which the liquid escaped. Case No: 377306 Determination Page 7 of 8 3 Supporting information 3.1 FOS approach to this dispute As advised to the parties, FOS has considered it appropriate to expedite this dispute in accordance with the Operational Guidelines to the FOS Terms of Reference, due to the nature of the dispute. Accordingly, this dispute has not been the subject of a FOS Recommendation and has proceeded directly to Determination. There has been a full exchange of all material information relied on for the purposes of this Determination and each party has had the opportunity to add ress any issues raised by the other. All of the material provided by the parties has been reviewed and considered for the purposes of this Determination. This dispute has been decided on its merits, having regard to the relevant law, good industry practice, codes of practice and previous Financial Ombudsman Service (FOS) decisions. While the parties have raised numerous issues in their submissions, for the purposes of this Determination, commentary has been restricted to those issues considered directly relevant to the outcome only. 3.2 Terms of policy Subject Terms Insured event – escape of liquid Insured event Sudden and unexpected escape of liquid at the insured address from:  baths, sinks, toilets, basins or any fixed plumbing apparatus …  pipes and taps … We will not cover:  the cost of repair or replacement of the pipe … that the liquid escaped from, including the cost of repairs to a leaking shower floor, base, or walls  loss or damage caused by leaking shower floors or bases, tiled roman baths or shower recess walls …  loss or damage caused by liquid that has escaped slowly over a period of time, unless it is reasonable that you could not have known about the liquid escaping. General exclusion – earth movement We will not cover: … Earth movement  loss or damage caused by erosion, vibration, subsidence, landslip, landslide, mudslide, collapse, shrinkage or any other earth movement. Case No: 377306 Determination Page 8 of 8 Subject Terms General exclusion – faulty workmanship and lack of maintenance We will not cover: … Defects, faulty workmanship, lack of maintenance  loss or damage or the incurring of legal liability caused by a design fault, structural defect, or faulty workmanship that you knew about and did not fix before the loss or damage occurred  loss or damage caused by your failure to maintain the home and/or contents in good condition .

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.