Home / Financial Firm (Unknown - Insurer) / Determination 376254

Determination 376254

Denial of claim for floor and sub-floor damage to a unit from long-term seepage and rot

FirmFinancial Firm (Unknown - Insurer)
Decided2015-06-05
ProductGeneral Insurance · Strata
OutcomeFor the firm
Amount awarded—
Non-financial loss—
Amount claimed—
SourceAFCA PDF

Summary

An individual claimed under her unit policy for floor damage caused by water seeping from a courtyard concourse over time. AFCA found the damage resulted from gradual deterioration and latent defect, both excluded, so the FSP was entitled to deny the claim.

Long-term seepage, rot and latent defect in the building structure are excluded under the policy, and the damage was not accidental.

Issues

Subjects and remedies

home or building damageno remedy

Related

All Financial Firm (Unknown - Insurer) determinations · Find similar determinations

Text of the determination

Determination General Insurance - Domestic Insurance - Residential Strata Title - FSP Decision - Denial of claim Determination Case No: 376254 Determination Page 1 of 7 Case number : 376254 4 June 2015 1 Overview 1.1 Dispute The Applicant lodged a claim for damage to her unit with the Financial Services Provider (FSP). The FSP denied the claim on the basis the damage was due to a number of causes excluded from cover including seepage, gradual deterioration and latent defect. The Applicant disagrees with the FSP‟s decision. She says the damage to the property was due to accidental breakdown of the waterproof membrane in the courtyard area adjacent to her unit and therefore her claim should be accepted. 1.2 Issues and key findings Has the Applicant established an insured event? The Applicant has established a claim for accidental damage under the policy because the damage to her unit was unintended and unexpected. Is the FSP entitled to deny the Applicant’ s claim? The FSP is enti tled to deny the Applicant‟s claim because:  Expert evidence indicates the damage occurred as a result of rotting of the sub-floor timbers due to: o a poorly designed concourse that allowed water to seep into the timber floor over an extended period of time, and o a lack of sub-floor ventilation.  The policy specifically excludes loss or damage caused by inherent vice or latent defect. 1.3 Determination This Determination is in favour of the FSP. The FSP is entitled to deny the Applicant‟s claim . Case No: 376254 Determination Page 2 of 7 2 Reasons for Determination 2.1 The FOS Approach I have determined this dispute based on what is fair in all the circumstances, having regard to the relevant law, good industry practice, codes of practice and previous Financial Ombudsman Service (FOS) decisions. I have taken into account all the material submitted by the parties. There has been a full exchange of all documents relied on to make this Determination and each party has had the opportunity to address any issues raised by the other. This dispute has proceeded straight to a Determination. No Recommendation was issued. 2.2 Is the FSP entitled to deny the claim? The damage to unit was accidental The Applicant bears the onus of establishing, on the balance of probabilities, that she has a valid claim under the policy. The policy provides cover for accidental damage to the insured property subject to a number of exclusions. The policy does not defin e the term „accidental‟ however the cour ts have interpreted it to mean „unintended and unexpected‟ . The Applicant says her tenants initially noticed cracks appearing within the unit around the front door and laundry area. Subsequent investigations revealed this was because the floor had dropped as a result of water seeping into the subfloor area causing the timbers to deteriorate and rot. There is no evidence to suggest the damage to the unit was intended or expected. Accordingly, the Applicant has established the claim falls within the broad cover for accidental damage provided under the policy. The onus therefore shifts to the FSP to establish the exclusions relied upon to deny the Applicant‟ s claim. Available information establishes damage was caused by excluded factors The Applicant‟s policy excludes damage caused by :  gradual deterioration  inherent vice and latent latent defect  normal seepage in buildings, foundations/footings, paths, garden borders and other structural improvements. Relevant extracts from the policy are set out in section 3.1 below. Case No: 376254 Determination Page 3 of 7 The Applicant says the damage to her unit arose due to the accidental failure of the waterproof membrane in the adjacent courtyard, which allowed water to seep into the sub-floor of her property. The FSP says the damage to the Applicant‟s unit occurred over an extended period of time as a result of defects in the construction of the property. It says serious drainage problems at the complex caused substantial long term ingress of moisture into the Applicant‟s unit. The FSP relies upon the findings of the builder (JM) appointed to inspect and report on the cause and extent of the damage. In his report dated 5 August 2014, JM noted:  white marks on the concrete floor slab confirmed substantial long term ingress of moisture from the concrete concourse outside  the concourse surface is poorly graded and incapable of rapidly collecting and shedding rainwater to drainage points  long term pooling of water outside the front of the unit on the concourse has occurred and caused seepage into the timber floor structure causing it to rot  the timber floor structure is sub-standard as it has no sub-floor ventilation – the lack of cross flow of air has allowed moisture to build up which is conducive to gradual deterioration. On balance, having considered all the evidence, I conclude that the proximate cause of the damage is the poorly designed concourse and the failure of any sub - floor ventilation. Even if there was accidental damage to the waterproof membrane (of which there is no evidence), such failure was not the dominant cause of the damage to the Applicant‟s unit. The damage to the Applic ant‟s unit arose as a result of inherent vice or latent defect, which is excluded by the policy. The FSP is therefore entitled to deny the Applicant‟s claim . In reaching this conclusion, I have considered the Applicant‟s acknowledgement that while the buil ding wasn‟t the best of design, it was passed by local council inspectors at the time. However, this does not change my view regarding the cause of the damage, even if this was not detected by council inspectors. Other matters not necessary to consider The FSP also made submissions regarding the Applicant‟s knowledge of the defects and failure to notify the FSP of such matters which were relevant to the provision of insurance. However, as I have found the exclusion regarding latent defect to apply, it is not necessary for me to consider this aspect of the FSP‟s submission. Case No: 376254 Determination Page 4 of 7 3 Supporting information 3.1 Terms of policy Subject Terms General Definitions Event, Events means a happening or an incident not intended to happen which occurs during a particular interval of time and causes or results in loss or damage, or series of loss or damage happening from that one Event, that is claimable under this Policy Policy 1 – Insured Property Policy 1 is a „broad form‟ accidental loss and damage contract in terms of the Insurance Contracts Act 1984 What we insure We insure you up to the Sum Insured for Policy 1 on the Schedule, against ACCIDENTAL LOSS or DAMAGE to Your Insured Property which occurred during the Period of Insurance Exclusions – What we do not insure 1. We will not pay for loss or damage : … c. caused by lack of maintenance, rust, oxidation, corrosion, Wear, Tear, fading, gradual corrosion or gradual deterioration, concrete or brick cancer, developing flaws, wet or dry rot, or failure to maintain Your Insured Property in a r easonably good state of repair d. c aused by non - rectification of an Insured Property defect, error or omission that You were aware of, or should reasonably have been aware of. … j. caused by inherent vice, l atent defect, vermin, mice, rat s, termites, insects, mildew, or by pecking, biting, ch ewing or scratching by birds or animals However W e will pay if any of these causes [ including inherent vice, latent defect] directly result in loss or damage from any other Event claimable under Policy 1 such as fire or glass breakage. … m. due to normal set tling, creeping, heaving, seepage, shrinkage, or expansion in buildings, foundations/footings, walls, bridges, roadways, kerbing, driveways, paths, garden borders and other structural improvements. Case No: 376254 Determination Page 5 of 7 Subject Terms 2. We will not pay for : … b. The cost of rectifying faulty or defective materials or faulty or defective workmanship … 3.2 Chronology, including key reports Date Event / report Approx July 2013  Tenants beca me aware of large cracks on the foyer and laundry areas.  Tenant notifies the Applicant‟s brother, who was also living in the flat, who agreed to tell the Applicant (who was then overseas).  The issue was to be raise d wi th the body corporate at the next meeting. 25 July 2013 AGM  AGM notes the water issues in unit 3, the common area and the car park were discus sed.  In unit 3, t he dropping of the floor in different areas, moist smell in winter in the loun ge room and the rotting carpet we re all attributable to the water. 6 December 2013  Invoice for rectification works of previously laid membrane that failed. It notes: o The cracking of two rear courtyard s , the front courtyard and trafficable areas was extensive. o The previous membrane that was applied had failed. o A n ew waterproof membrane is to be applied. January 2014  Rectification work commenced 3 May 2014  Building quote stating: O n inspection of the property includ ing the sub - floor support system, it is clear that water has entered the sub - floor area and caused the bearers t o rot and deteriorate to the point of needing replacement. 27 May 2014  Assessor‟s report notes the recent installation of a trafficable membrane to the common area walkway and drip trays in the basement car park (to mitigate seepage adversely affecting resident‟s vehicles).  Causation/ Sour ce was: “ Seepage and run off of water from the surrounding floor surface of the common courtyard area has seeped b en eath Units 3‟s floor causing gra dual deterioration and rot of the sub - floor structure over an extended period.” Case No: 376254 Determination Page 6 of 7 Date Event / report 5 May 2014  Claim submitted 3 June 2014  Applicant‟ s claim declined. FSP’s expert (JM ) Report 5 Aug 2014  Property inspected 3 July 2014.  Unit approximately 10 years old.  White marks on concrete floor slab confirms substantial long - term ingress of moisture from the concrete concourse outside.  Some adjustment to the previous membrane coating has been carried out; however, the concourse surface is still poorly graded and incapable of rapidly collecting and shedding rainwater to strategically located drainage points.  Before level adjustment, pools of w ater are believed to have continually accumulated and fed seepage under the floor on a long - term basis causing rot of the floor structure at the South East corner.  Any reputable concourse membrane firm would have first ensured the levels and falls on the c oncourse were correct to enable rapid shedding of water to drainage points.  The timber floor structure is non - compliant and requires sub - floor ventilation. Inevitable that condensation occurs – proper cross flow ventilation is required to ensure moisture i s progressively removed to avoid rot.  Entire timber floor structure requires replacement.  Clear evidence that long - term pooling of water outside the front of the unit on the concourse has occurred and caused seepage into the timber floor structure and asso ciated timber deterioration by rot.  No attempt should have been made to lay the waterproof membrane onto an incorrectly graded concourse profile with insufficient falls.  Building code of Australia stipulates continuous cross flow of air is required to prog ressively remove normal moisture build - up. The subject apartment has never had any sub - floor ventilation therefore trapping moisture which is conducive to gradual deterioration.  The building should never have obtained a permit for such substandard/non - com pliant construction. Assessor’s report 7 August 2014  The damage is excluded.  The long term seepage damage is not the result of, or associated with, an accident or claimable event. Case No: 376254 Determination Page 7 of 7 29 August 2014  IDR letter confirmed denial of claim.

Coded fields were extracted from the text by a language model and may contain errors. The published PDF is the authoritative record.