Storm damage claim largely denied under policy exclusions
Summary
The FSP accepted part of the storm claim (water ingress to the ceiling, offered $5,442.91 less GST and excess) and declined the rest as caused by excluded wear, workmanship and design. AFCA upheld the limited scope and ordered the FSP to settle the water damage at a current quotation, with no interest.
Once the insured establishes a prima facie claim the insurer must prove an exclusion applies, and expert evidence showed the remaining damage arose from excluded causes.
Subjects and remedies
pay claim
Text of the determination
Determination
General Insurance - Small Business/Farm Insurance - Commercial Property - FSP
Decision - Denial of Claim
Determination
Case No: 375956 Determination Page 1 of 10
Case number : 375956 4 March 2015
1 Overview
1.1 Dispute
The Applicant holds a childcare centre insurance policy with the Financial
Services Provider (FSP), for which a claim for storm damage was submitted on
3 July 2014.
The FSP accepted the claim for some of the damage to the ceiling. However, the
FSP declined the remainder of items claimed as it considered these were not
damaged as a result of the storm event.
1.2 Issues and key findings
Has the FSP fulfilled its obligations under the terms of the policy?
The FSP has fulfilled its obligations under the terms of the policy because:
it has accepted and quantified the damage arising from the claimed event
it has established that the remainder of the damage claimed has arisen as a
result of causes specifically excluded from the terms of cover.
1.3 Determination
This Determination is in favour of the FSP.
The FSP was entitled to limit its liability in respect of the claim to encompass that
damage only which arose from the claimed event. The FSP should settle those
costs, after obtaining a current quotation from its contractor.
The remainder of the damage arose from causes specifically excluded from cover
and therefore the FSP is not liable for those losses.
Case No: 375956 Determination Page 2 of 10
2 Reasons for Determination
2.1 Has the FSP fulfilled its obligations under the terms of the policy?
I have decided this case on its merits, having regard to the relevant law, good
industry practice, codes of practice and previous FOS decisions. I have taken into
account all the material submitted by the parties.
There has been a full exchange of all documents relied on to make this
Determination and each party has had the opportunity to address any issues
raised by the other. Expert opinion has been provided by the parties.
The Applicant has established a prima facie claim
The FSP‟s policy is an accidental damage policy which is subject to specific
exclusions from coverage.
It is accepted Insurance law that the Applicant carries the onus of proving that an
insurable event has occurred. This is known as a prima facie claim.
Once the Applicant has established a prima facie claim, the onus shifts to the FSP
if it wishes to deny the claim on the basis of an exclusion under the policy.
There is no dispute the property was damaged during the storm event by water
ingress. There is further no dispute between the parties that the FSP has
accepted the Applicant‟s claim for water ingress and offered settlement in the
amount of $5442.91, less GST and the policy excess.
Accordingly, the Applicant has established a prima facie claim under the terms of
the policy and the FSP must now establish it is entitled to limit its liability for the
claim, by establishing that the specific exclusions listed, operate to defeat the
remainder of the claim.
The FSP’s policy contains specific exclusions from cover
Whilst the policy will respond to claims for loss or damage arising from storm or
water ingress, it specifically excludes loss or damage caused by or arising from or
in connection with wear and tear or gradual deterioration, error in or failure of
design or faulty materials or workmanship.
The expert reports provided confirm some of the damage arose from causes
specifically excluded from cover
The FSP engaged three building firms to inspect and report on the damage
evident at the premises.
Whilst building firm “AB” attributed all of the damages evident to the ceilings to the
claimed event, firms “CC” and “MS” considered that only the water staining was
consistent with the storm event. Both concluded that the delaminating of the
plaster linings and cornices had arisen as a result of pre-existing issues with the
building.
Case No: 375956 Determination Page 3 of 10
Engineering firm “MC” was subsequently engaged to provide an engineer‟s
opinion as to the cause of the damage evident.
MC considered that there was damage consistent with a water entry event, with
water stains to the ceiling linings. However, it was MC‟s opinion that the dropping
of the ceiling linings and the delamination of the cornices were not as a result of
the claimed event.
MC considered these had arisen as a result of a combination of factors, including
poor installation techniques, thermal and building movement and the lack of
installation of expansion joints at the time of construction.
MC concluded that the cause of the cracking and tenting tiles under the stairwell
area was as a result of the combination of factors being the lack of expansion
joints installed at the time of construction and issues with either the adequacy of
the adhesive or the manner of its application. The experts‟ conclusions are
supported by the photographs provided.
All of these causes are specifically excluded from the terms of cover.
It is accepted that MC is appropriately experienced and qualified to comment in
this matter and in the absence of conflicting information, the FSP is entitled to rely
on his findings.
It is also noted that the findings of CC and MS were consistent with the findings of
MC.
The Applicant has not sourced his own reports
The Applicant was given the opportunity by this Service to source his own expert
reports as to the cause of the damage. However, the Applicant has not provided
any additional information in support of his case.
Accordingly, after considering all of the available information, the FSP has
established the application of its exclusions to cover under the terms of the policy.
Therefore, in the absence of conflicting information, the FSP is entitled to rely on
the findings of its expert MC, that the damage not excluded under the policy is
limited to the water stained ceilings.
On this basis, the FSP is entitled to limit its settlement to reflect only the costs to
repair the damage arising as a result of water ingress to the ceiling.
The Applicant has not challenged the amount offered by the FSP in settlement of
this aspect of his claim, or the FSP‟s entitlement to settle his claim by way of cash
payment. However, the quote submitted by M was valid for six months only. The
FSP is therefore to request M to adjust their quotation to reflect an accurate cost
at today‟s prices to remedy the claim related damage. On this basis, an award of
interest is not appropriate.
Case No: 375956 Determination Page 4 of 10
Other matters
Whilst not relevant to the outcome of this dispute, the Applicant has raised other
issues he has concerns with, namely the FSP‟s decision only to assess his
property for defects at the time of the claim rather than at inception or renewal. He
also question s the qualifications of the FSP‟s experts and why multiple firms were
engaged.
The Applicant‟s concerns are understandable, however , it is common industry
practice to incept a policy without sighting the risk. Instead, most insurers will rely
on a set of specific questions regarding the risk to be insured in order to gauge
whether they are prepared to offer cover. It is the responsibility of the insured to
answer these questions accurately. Where issues become evident at the time of
the claim, the FSP is entitled to asses those.
It is also not uncommon for an FSP to engage multiple experts or obtain more
than one quotation for claimed works. This is part of providing proper and sound
assessment of a claim.
Case No: 375956 Determination Page 5 of 10
3 Supporting information
3.1 FOS ’s approach to this dispute
This dispute has not been the subject of a FOS Recommendation. Due to its
nature, it was appropriate to proceed directly to a Determination in line with the
Operational Guidelines to the FOS Terms of Reference.
3.2 Expert Reports
Record Key points
FSP’s expert ( AB )
B uilder ‟ s Report
12 Aug 2014
the roof area was inspected and there was no visible
storm damage evident
there was one broken tile which was likely caused by foot
traffic
the roof was a concrete tiled roof with a metal skillion roof
area constru cted in the middle of the property
the roof design is awkward with the pitch tiled roof areas
surrounding the skillion roof which comes off a section of
tiled roof
where the ends meet the metal sheets to the apex of the
tiled roof, this has been capped wit h concrete ridge tiles
there is a number of cement tiles placed on the area
where the tiled roof meets the skillion roof, these should
be removed
both metal and tiled roof areas seem in fair condition
maintenance was required to the box guttering as there
was build up of debris evident
where the metal skillion roof is overlapped by the two
tiled areas, this is an awkward angle
if debris builds up around the tiled edges there is a
possibility of water overflowing to the ceiling cavity
if water ingress was to occur at this junction it would be
due to the design flaw
there was staining to the ceiling evident in the open plan
area at the centre which was possibly caused by water
ingress due to wind driven rain
the movement, delaminating of cornices and large cra cks
to ceiling linings are as a result of storm damage
however a building consultant should be engaged to
confirm the cause
as the ceiling linings are delaminating from the roof
structure, feelings may collapse at any time
steps should be taken to secure feelings to prevent any
type of collapse
FSP’s expert ( MS )
Builder‟s Report
not all of the damage seen is consistent with the water
ingress event
Case No: 375956 Determination Page 6 of 10
31 July 2014 some of the works will not be able to be warranted
there are a number of roof tiles being stored on top of the
existing roof, these tiles need to be stored elsewhere
there were large cracks to one part of the living room
ceiling, and parts of the ceiling that had dropped in other
areas
there was water staining to some parts of the ceiling
some areas had delaminated cornices and there were
cracked and lifted floor tiles in one area
the large cracks looked to be more as a result of
structural movement
the cornices were wavy which looked to be as a result of
poor installation
the dropped and stained cei ling looked to be as a result
of water ingress
the cornices in the bathroom had delaminated from the
wall tiles, this was as a result of the cornice being glued
to the tiles with cornice cement rather than a flexible
adhesive
the floor tiles had lifted and cracked as a result of
insufficient expansion joints
the water ingress has occurred under the metal skillion
roof which was added to the property
the water ingress happened in unusually heavy rain but
the box gutter which is installed is quite small for t he area
another contributing factor to the water ingress is the fact
that where the metal roof joins the tiled area there is no
proper flashing installed, just the tiles sitting over the
metal roof
FSP’s expert ( CC )
Builder‟s Report
12 Aug 2014
the site was inspected in the company of the insured
the insured advised that a severe storm consisting of
strong winds and heavy rain struck the property
sometime in March 2014
he is unsure of the exact date
water was witnessed running through the light fittings i n
the ceiling in the toddler room
insured punched holes in the ceiling lining to relieve the
water build up and to prevent the ceiling from collapsing
insured advised the property was built around 1989 and
he had purchased it in 2004
this is an owner occup ied, split level house of double
brick construction and roof clad with concrete tiles
the building has been maintained in average condition
there was water staining to the plasterboard ceiling lining
in the centre of the lounge room
several penetrations to the plasterboard were evident,
where the insured had punctured it to relieve the buildup
of water
there was noticeable separation of the plasterboard
cornice throughout the residence
Case No: 375956 Determination Page 7 of 10
there was also minor and major cracking to the
plasterboard ceilings thr oughout
the ceramic floor tiles near the under stair storage area
were cracked
where there is evidence of water related damage, the
nature of these damages is relatively minor
this leads to a conclusion that the separation of the
cornices in various areas, ceiling linings and of the floor
tiles underneath the stairwell are due to unrelated
maintenance issues relating to natural movement for
settlement having occurred in the foundations of the
property
the resultant damage has been caused as a result of the
box gutter being too small and inadequate to service the
large surface area surrounding roof, which led to an
overflowing during heavy rain
there are no storm created openings or related damages
to the roof
unrelated to the claimed events, the pointing to the ridge
capping is in poor condition and proposes a potential leak
risk
there are numerous ch ipped/ broken tiles and
approximately 30 concrete tiles are loose and not
securely fastened to the roof , which pose a risk of being
dislodged during strong wind gusts
the insured is responsible for undertaking the
maintenance works at the property
we recommend an engineer be engaged to confirm the
cause of the cracking
FSP’s expert ( MC )
Engineer‟s Report
3 Sep 2014
the property in question is a single story cavity full brick
constructed dwelling with a cement tiled roof and a near
flat pitched roof made of steel sheeted metal
internal walls are hard set plaster finish ed with gypsum
plasterboard ceiling linings
the bui lding is currently used in the capacity of a
childcare centre, and appeared to have had a number of
conversions and additions post original construction
this includes infilling of the once existing external the
pergola to create an internal large playroom
in addition , extensions at the rear of the building , which
now accommodates the toddler toilet
the original building construction is estimated to be in the
mid 1980‟s
insured advised that there was storm activity in April
2014 whereby water penetrated into areas within the
building namely the toddler‟s room, large playroom,
change room and kitchen area
after the ceiling was saturated stains have been evident
and the ceiling linings have displaced from the ceiling
leading to sagging and cracking
Case No: 375956 Determination Page 8 of 10
the insured has temporarily re - fixed the ceiling place to
mitigate further loss and potential for collapse
at the time of inspection there was no danger of the
ceiling collapsing and no danger to the occupants of the
dwelling
inspection revealed minor water stains evi dent about the
light fittings
sections of the cornices have displaced
sections of the ceiling lining had displaced and been
temporarily secured back the ceiling joists
extensive cracking within the ceiling lining has
propagated about the abutting sheet joi nts
under the stairwell floor tiles have cracked and lifted and
are drummy
the floor tiles appeared to be directly fixed to the concrete
slab
the roof cavity and framing was inspected through the
manhole access within the toddler room
there was no access into the roof above the large
playroom ceiling as the ceiling lining is fixed directly to
the roof rafters of near flat pitch
roof framing consists of conventional timber rafters,
battens and collar ties supported by load - bearing walls
including sarking in stalled beneath the roof tiles
ceiling framing includes timber rafters and hanging
beams with installation batts on top of the plasterboard
ceiling linings
the plasterboard ceiling lining is fixed directly to the
ceiling rafters
there were significant debr is about the sheeting which
could cause long - term loading and fixing integrity
the roof and ceiling framing appeared to be structurally
sound without any significant movement or displacement
evident
sarking about the valley gutter was torn and would allow
possible penetration of both water and wind into roof
cavity area
notwithstanding the above, no water damage or
penetration into the ceiling space was evident
there was no water or mould to the installation batts ,
which would be expected if there were sign ificant water
entry
there were no significant breaks or voids about the tiling
or bedding
the roof and box guttering inspected were found to be
well - maintained and free - flowing , without any buildup of
debris evident
the location of water entry into the tod dler room aligned
with the location of the valley gutter
the intersecting junction of the cement roof tiles and the
flat metal sheeting does not comply as an acceptable
Case No: 375956 Determination Page 9 of 10
flashing method and is considered to be incorrectly
constructed
there was incorrect col lar flashing method used around
the service ducting and risers
in general plasterboard is not designed to withstand
stress due to structural movement or excessive changes
in temperature and humidity
the large playroom, having the ceiling fixed directly to the
rafters near the flat steel sheeted roof and minimal ceiling
cavity, will produce thermal expansion and movement
within roof framing and material s, causing cracking of the
plasterboard lining
no provision for any expansion joints within the ceiling
lining have been installed in the dwelling
plasterboard sheet butt joints should be supported by
„back blocking‟ which is the reinforcing system designed
to minimise cracking and deformation along the joints,
which was not or could not be completed in the dwelling
the omission of such back blocking has exacerbated the
severity of crack propagation within the plasterboard
ceiling lining within the toddler room and large playroom
in the absence of expansion joints and back blocking
provisions, any structural and thermal movement within
the ceiling will cause crack propagation in the ceiling
lining about the weakest planes
the observed cracking and elimination of the cornices is
attributable to pre - existing installation factors
these include the omission of bac k blocking about the
plaster sheet, a large amount of debris, wires, service
ducting and installation batts creating a dead load over
time onto the sheet and fixings and structural movement
and excessive changes in temperature
the cracking and detachment w ithin the plasterboard is
clearly related to long - term general building defect and
thermal movement and is unrelated to the storm event or
rainfall entry
the various water stains evident throughout the ceiling is
consistent with water entry into the roof c avity during a
storm event
water has entered into the roof space at the valley gutters
and junction that the cement tiled roof and steel sheeted
roof as a result of pre - existing poor flashing techniques
combined with high intensity of rainfall
the damage t o the floor tile beneath the stairwell relates
to thermal movement and uplift as a result of inadequate
provisions of expansion joints at the time of construction
the damage to the tiles has not been as a result of water
ingress or saturation
tiles around the uplifted segment were identified as
having a drummy or hollow sound
given the large playroom floor area dimension, concrete
Case No: 375956 Determination Page 10 of 10
substrate and the direct fixing of tiles it is critical to
provide such articulation \ movement joints within the tiles
to accommodate expansion or creep
the floor tiles appeared to be laid directly over the
concrete slab by using a fixative, therefore any cracking
or movement within the concrete slab will directly
propagate through the tile adhesive and tile itself
had the fl oor been installed in accordance with the
applicable standard, the cracking and tenting of the tiles
would likely not have occurred
the cause of the dislodged tiles is attributable to poor
workmanship due to the lack of provision for expansion
joints
this omission is clearly a pre - existing building defect
the drummy or loo se tiles have likely occurred as the
result of one of the following reasons: not enough
adhesive under the tiles or dabbing of adhesive which
leaves hollow voids, the wrong adhesive has be en used
and has not bonded to the tiles or substrate or in wet
areas the adhesive was not suitable and has broken
down, or the adhesive has skinned before the tile were
laid. This means the adhesive was put down and left too
long and the surface has dried, preventing a sound bond
to the tile
the tile damage is not related to the claimed water entry
from the storm and is due to pre - existing poor installation
processes in not allowing adequate provision for
expansion joint and inadequate adhesive bonding .